Westec 400B Basics

Do not power down this system. Use the sleep switch in the panel

Downloadable No
Arm Turn keyswitch to the right to the ARM/RESET position & release
(Arm light will flash until the delay time expires and then the light will turn solid)
Disarm Turn keyswitch to the right to the ARM/RESET position & release (Arm light will go out)
Reset Burg Turn keyswitch to the right to the ARM/RESET position & release
Reset Fire Turn keyswitch to the right to the ARM/RESET position & release
Reset Trouble Slide the TR SIL (Trouble Silence) switch to the left (button is located on the bottom of the alarm panel)
Alarm Memory There is no alarm memory ( if the system loses power will come back up disarmed)
Test Press TEST button. Alarm will sound a fire alarm for 1 second, then a low level alarm for 1 second, loud
burg alarm for 1 second, the another low level alarm until reset with keyswitch.
Light 1 (ARM) Off – System is disarmed
On – System is armed
Flashing w/ low level sound – System is armed but in entry/exit delay
Flashing w/ loud sound – Alarm has tripped
Light 2 (Pwr Tr Sil) On – System has power
Off w/ no sound – No power to panel
Off w/ pulsing sound – System in trouble
Flashing w/ no sound – System in trouble, but silenced with Tr Sil switch
Flashing w/ pulsing sound – Tr Sil button in silence position, but there is no trouble