Visionic Powermax Basics

Zones Up to 30 Wireless Zones
Batteries
Main Panel 6 “AA” 1.2 Volt Lithium rechargables or 6 1.5 Volt AA Alkaline
Door/Window 3.6 Volt Lithium
Keyfob 12 Volt Alkaline
Motions 3.6 Volt Lithium
Smoke Detector 1 or 2 9 Volt Alkaline
AC Transformer 9Volt
Downloadable Yes
Panic Buttons Police Panic only (Press both Panics at same time)
Away Arm AWAY + User Code (Display shows “ARMING AWAY”)
Stay Arm HOME + User Code (Display shows “ARMING HOME”)
Instant Arm HOME or AWAY + User Code + 0 (Display shows “ARMING INSTANT”)
Quick Arm Press HOME or AWAY to Arm (May not be Enabled)
Disarm OFF + User Code
Check Status Press SHOW/OK for Troubles or Open Zones
Silence Alarm OFF + User Code
Reset Smoke OFF + User Code
Door Chime Press 8 key to turn ON or OFF
Bypass 1. Open Zone to Bypass
2. Press AWAY + AWAY or HOME + HOME + User Code
Volume Control Press 1 to raise and 4 to lower speaker volume
Silence Voice Press 7 to turn Voice OFF or ON
Messages Press 2 to record 15 second message, press 5 to listen
Light Control Press 3 to turn X-10 Lights ON, press 6 to turn OFF (If enabled)
Alarm Memory Press SHOW/OK to review all events, Arm then Disarm to clear
Remote Access 1. Call home phone, let ring twice then hang up
2. Wait 15 seconds then call again
3. PowerMax sounds tone, wait until finished then enter User Code
Remote
Commands
Disarm * + User Code + 1
Arm Home * + User Code + 2
Arm Home & Instant * + User Code + 21
Arm Away * + User Code + 3
Arm Away & Instant * + User Code + 31
Arm Away + Latchkey * + User Code + 4
Arm Away + Instant + Latchkey * + User Code + 41
Go 2-Way Voice * + User Code + 7 (1 to Talk 3 to Listen)
Playback Recorded Messages * + User Code + 8
Check System Status * + User Code + 9
End Communication * + 9 + 9
Pager Signals Pagers sends 3-digit Event + 4-digit Zone or User Number
101 + (0001 to 0009) = Closing/Arming by User 01 to 09
102 + (0001 to 0009) = Opening/Disarming By User 01 to 09
103 + (0001 to 0009) = Latchkey Arm by User 01 to 09
515 + (0001 to 0030) = Fire Alarm Zones 01 to 30
616 = Panic Alarm
717 = Emergency Alarm
818 + (0001 to 0030) = Trouble on Zone 01 to 30
919 + (0001 to 0030) = Alarm on Zone 01 to 30
Set Time 1. Press NEXT until “USER SETTINGS”
2. Press SHOW/OK then enter Master Code
3. press Next until “TIME HH:MM A”
4. Press SHOW/OK and enter 4-digit Time
5. Press * for AM or # for PM (1:30AM would be 0130*)
6. Press AWAY until “OK TO EXIT” displays
7. Press SHOW/OK to exit
Set Date 1. Press NEXT until “USER SETTINGS”
2. Press SHOW/OK and enter Master Code
3. press Next until “DATE MM/DD/YY”
4. Press SHOW/OK and enter 6-digit Date (July 2 2000 would be 07 02 00)
5. Press AWAY until “OK TO EXIT” displays
6. Press SHOW/OK to exit