Channel 2 Outputs (Every time button #2 is pressed, two outputs happen simultaneously.)
Output #1 |
Momentary Contact Closure for Opening and Closing garage door |
Output #2 |
500ma (-) output for 3 minutes, (See Channel 2 Timed Output) |
|
Channel 2 Timed Output |
Every time button 2 is pressed the Gray wire sends a 500ma (-) output for 3 minutes.
Application #1 – If you hardwire garage door use this output to trigger a 12VDC relay that energizes
when you open or close garage door extending entry/exit delay by 3 minutes, for security make
entry delay minimal so if thief enters through garage, entry delay will be short
Application #2 – You can use this output to drive entry/exit illumination
Every time customer enters or exits house this output can trigger a relay or X-10 Powerflash module
to interface with driveway, porch or Malibu lighting illuminating way as they leave and return home
The output activates automatically when you press button 2 on remote and will shut off after 3 minutes
|
Relay Output |
Occasionally, you may want to use Channel 3 for control of optional accessories
Code Encryptor II provides the ability to reconfigure Channel 3 to a variety of outputs using
on-board jumpers. The output provided from Code Encryptor II is 5amp from C relay (Common, N/O, N/C)
Jumper Configuration |
Channel 3 Output Type |
Both jumpers in (default) |
Momentary output |
Jumper closest to the harness removed |
Latching (on/off) output |
Jumper farthest from the harness removed |
75sec timed output |
Both jumpers out |
150sec timed output |
This output is a 5 amp Form C relay (Common, N/O/, N/C) to energize relay, press & release button 3
|
Deactivating Panic Feature |
In the event the user does not want panic button it can be de-activated from Code Encryptor II
Step 1) Unplug the wire harness from the Code Encryptor II
Step 2) Press and HOLD the program button
Step 3) While HOLDING program button, plug harness in, LED will turn ON
Step 4) Wait until LED turns “OFF”
Step 5) Once LED has turned “OFF” release button
|
Activating the Panic Mode (If panic was previously disabled)
Step 1) |
Unplug the wire harness from the Code Encryptor II |
Step 2) |
Press and HOLD the program button |
Step 3) |
While HOLDING the program button, plug the Code Encryptor II harness
back in. The LED light located on the front will turn ON
|
Step 4) |
Immediately release the program button |
|
To add a NEW remote |
METHOD #1
1. Disarm panel and Enter 78738 from keypad. System will arm in “STAY” mode
2. Press button #1 (largest button) until system disarms. It should take a four presses
METHOD #2
1. PRESS and RELEASE program button on receiver. LED will turn ON
2. Immediately PRESS button 1 (largest button) on new remote control THREE TIMES
LED receiver should go OFF, indicating the remote has been learned
Note: If LED stays ON, remote not learned. Remove & replace harness, wait 15 seconds and try again
|
To DELETE ALL remotes |
METHOD #1
Purge entire memory by disarming panel. Enter 76278 from keypad
Keypad on most panels will “beep” or lights will turn off momentarily to confirm delete
METHOD #2
PRESS and HOLD program button, LED will turn ON for four seconds, then go OFF then ON again
All remotes in memory have been purged, release program button
|
Specifications |
RECEIVER
12VDC Power Input
Channels 1 Data outputs
Channel 2 Relay N/O, Comm (10amp)
Channel 3 selectable: Form C Relay (N/O, N/C, Comm) 5amp
This output can be reconfigured from pulsed output to latching, 75 or 150 second timed output
Channel 3 – Keypad panic data output (Programmable On or OFF)
Frequency 303Mhz
Stand by Power Consumption 15ma
Temperature Range -5°F to 160°F (Indoor use only)
REMOTE CONTROL
Battery 12VDC Mini (Part #GP23A) Range 150+ feet
|