Street Smart CE2P Program

Holds up to 7 keyfobs
Quick Installation
Step 1) Unplug the receiver from the wire harness
Step 2) Wire the Red, Black, Yellow and Green to the keypad
Step 3) Plug in the CE II Control Module

RED Connect to Keypad Red or Aux (+)
BLACK Connect to Keypad Black or Aux (-)
GREEN Connect to Keypad Green
YELLOW   Connect to Keypad Yellow
Step 5) HOLD program button on receiver. LED turns ON and stays ON for three seconds
then turn OFF. Once LED turns off, RELEASE program button, LED will flash rapidly
Step 6) Using keypad, slowly enter four-digit user code. (Do not use the Master Code)
After the fourth entry LED will stop flashing, Code is now learned into Encryptor
Button 1 Alarm AWAY/OFF/HOME Press and hold 3 seconds for “HOME” mode
Button 2 Garage Door OPEN/CLOSE
Button 3 PANIC OUTPUT – Hold for 3 seconds
Relay Output – Press and Release
Detailed Installation
Yellow Connect to yellow of keypad
Green Connect to green of keypad
Gray (-) Channel 2 Timed Output
Red/White Channel 2 N/O relay (Garage Door Pushbutton)
White Channel 2 Common (Garage Door Pushbutton)
Brown Channel 3 Common (5 amp)
Brown/White Channel 3 N/O (5 amp)
Blue/Green Channel 3 N/C (5 amp)
Red +12VDC
Black (-) Ground
Purple LED (-) Output

To add a NEW remote
METHOD #1
1. Disarm panel and Enter 78738 from keypad. System will arm in “HOME” mode
2. Press button #1 (largest button) until arm system disarms. It should take four presses

METHOD #2
1. PRESS and RELEASE Program button, LED will turn ON
2. Immediately press button 1 on new remote control 3 times
3. LED on receiver should go OFF, indicating remote learned
Note: If LED stays ON, remote not learned, remove & replace harness, wait 15 sec and try again

Default Code Encryptor
METHOD #1
Disarm panel, enter 76278 from keypad, Keypad will “beep” or lights turn off to confirm delete

METHOD #2
PRESS and HOLD program button, LED will turn ON for four seconds then OFF then ON again

LED Wiring – DO NOT CONNECT LED DIRECTLY TO GROUND!
LED is low voltage type and must run through Code Encryptor II
If you attempt to connect purple wire directly to ground (-) the LED will burn out

Channel 2 Outputs – (Every time button #2 is pressed, two outputs happen simultaneously.)

Output #1 Momentary Contact Closure for Opening and Closing garage door
Output #2     500ma (-) output for 3 minutes, (See Channel 2 Timed Output)

Garage Door Interface
All garage doors have wall mounted push button that activates the door via a two-wire connection
Make connection at push button switch or garage door motor where these two wires terminate
Attach Code Encryptor Red/White & White wires from to these two wires
Most garage doors use terminals 1 & 2. For MOM Crusader models, use terminals 2 and 3

  Red/White   (Channel 2 Output)
White (Channel 2 Common)

Channel 2 Timed Output
Every time button 2 is pressed the Gray wire sends a 500ma (-) output for 3 minutes.

Application #1 – If you hardwire garage door use this output to trigger a 12VDC relay that energizes
when you open or close garage door extending entry/exit delay by 3 minutes, for security make
entry delay minimal so if thief enters through garage, entry delay will be short

Application #2 – You can use this output to drive entry/exit illumination
Every time customer enters or exits house this output can trigger a relay or X-10 Powerflash module
to interface with driveway, porch or Malibu lighting illuminating way as they leave and return home
The output activates automatically when you press button 2 on remote and will shut off after 3 minutes

Channel 3 Applications
Relay Output
Occasionally, you may want to use Channel 3 for control of optional accessories
Code Encryptor II provides the ability to reconfigure Channel 3 to a variety of outputs using
on-board jumpers. The output provided from Code Encryptor II is 5amp from C relay (Common, N/O, N/C)

  Jumper Configuration Channel 3 Output Type
Both jumpers in (default) Momentary output
Jumper closest to the harness removed Latching (on/off) output
Jumper farthest from the harness removed 75sec timed output
Both jumpers out 150sec timed output

This output is a 5 amp Form C relay (Common, N/O/, N/C) to energize relay, press & release button 3

Deactivating the Panic Feature
In the event user does not want panic button, it can be de-activated from Codee Encryptor II
Step 1) Unplug the wire harness from the Code Encryptor II
Step 2) Press and HOLD the program button
Step 3) While HOLDING program button, plug harness in. LED will turn ON
Step 4) Wait until LED turns “OFF”
Step 5) Once LED has turned “OFF” release button

Installation for Keyswitch Arming
Red Aux +
Black Aux –
Brown/White   Zone programmed for keyswitch arming
Brown Common adjacent to zone

Specifications
RECEIVER
12VDC Power Input
Channels 1 Data outputs
Channel 2 Relay N/O, Comm (10amp)
Channel 3 selectable: Form C Relay (N/O, N/C, Comm) 5amp
This output can be reconfigured from pulsed output to latching, 75 or 150 second timed output
Channel 3 – Keypad panic data output (Programmable On or OFF)
Frequency 303Mhz
Stand by Power Consumption 15ma
Temperature Range -5°F to 160°F (Indoor use only)

REMOTE CONTROL
Battery 12VDC Mini (Part #GP23A) Range 150+ feet

Optional Reversible Outputs
Channel 2 has two independent outputs that occur when button 2 is pressed
The first output is a momentary relay contact closure which is intended for the use of opening
and closing garage door. This is primary output and can not be changed or reconfigured.
The second output is a (-) 500ma transistor output to provide a zone bypass or illuminated entry/exit

If not using relay for Channel 3 you may choose to swap (-) transistor output for relay
In this instance you will then have two contact closures every time Button # 2 is pressed
The standard momentary contact closure and ALSO a Form C relay that energize for 3 minutes
every time garage door is opened or closed

To Swap transistor and relay outputs
Step 1) While watching the LED on the CE II receiver press and HOLD button 1 and 3 simultaneously
on the remote control until LED on CE II receiver illuminates. (approx. 5 seconds)
Step 2) To make channel 2 a relay press program button on CE II Receiver TWICE
to make it a transistor output press ONCE (Default setting)
Step 3) Wait 10 seconds and CE II will automatically reconfigure the outputs
NOTE – Even if you swap outputs, Panic button will operate if you press and HOLD for three seconds