Silent Knight 2721 Basics

For a blinking light:
    Alarm memory (Clear by pressing SHUNT, TEST)
Zone bypassed (clear by pressing SHUNT + Zone #)

To silence trouble beeps:
Shunt and installer code

Interior/Door Chime button:
Interior light on = Interior protection on
Press interior/door chime to turn chime on or off

To change codes:
(Note, the 1st digit of the code is the user #, do not go higher than 7 for the 1st digit of the code)
SHUNT
TEST
Master or installer code (Trouble light should blink)
Enter the new code followed by TEST (The first digit of the code will be the user #)
Press TEST, TEST, TEST, TEST

Low Battery:
The panel or keypad will make a click noise every minute.
This panel checks the battery that often…
also the lights will dim every minute & sends a low battery message