Enter Program 1. Open and remove panel door, set PROGRAM/RUN switch down
2. Enter Installer Code (by default there is no Installer Code)
Exit Program Set PROGRAM/RUN switch to UP
Default Panel 1. Turn Power Switch OFF then ON
2. Hold MEMORY CLEAR button on upper left, system says “Memory Goodbye”

Add Sensor 1. Press BYPASS or STATUS until LEARN SENSOR is displayed
2. Press COMMAND, keypad will display GROUP __ __
3. Enter GROUP <00 to 29, 32> + COMMAND button

Click HERE for complete list of Sensor Types

4. Keypad will show SENSOR ##, enter sensor <01 to 76>
5. Press COMMAND, keypad will read TRIP – ##, trip sensor
6. Once sensor is learned system will move to next sensor or activate Tamper
7. Press FIRE to exit
(Do not use SAW sensors on this system, use only older Learn Mode Sensors!)

Delete Sensor 1. Press BYPASS or STATUS until DELETE SENSOR is displayed
2. Press COMMAND button, Enter sensor to delete (01 to 76)
3. Press COMMAND button, keypad will show DEL ## OK
4. Press FIRE to exit
Add Touchpad 1. Press BYPASS or STATUS until LEARN TOUCHPADS is displayed
2. Press COMMAND button to display PRESS BYP TP-1
3. Press BYPASS on wireless touchpads and display will read One OK
4. Press FIRE to exit
Locations
BYPASS scrolls forward
STATUS scrolls back
COMMAND enters Location and saves settings
FIRE exits Location
01 – Delete Text
02 – Program Sensor Text
03 – Learn Sensors
04 – Delete sensors
05 – Upper Sensors (Zones 77 and above)
06 – F Options (Functions, see bottom of page)
07 – Learn Touchpads (Learns wireless keypads)
08 – Phone Number (18 digits, press Police Panic for 1 second pause)
09 – Phone Format (ITI Format, 4/2 1400hz, 4/2 2300hz supported)
10 – Siren Time-out (01 to 30 minutes)
11 – Install Code (Default is blank)
12 – Account Number (5 digits, A to F only programmed by CS-4000)
13 – Entry Delay (008 to 120 seconds)
14 – Extended Delay (Exit) (affects Group 11 sensors, 01 to 8 minutes)
15 – Exit Delay (008 to 184 seconds)
16 – Activity Time-out (01 to 24 hours)
17 – House Code (001 (A) to 255 (P) Default = 001)
18 – Freeze Temperature (40 to 90 degrees)
19 – Set Temperature (32 to 99 degrees)
20 – Touchpad Options
21 – AVM Mode (Interrogator 2000)
01 – 1 ring callback mode
02 – 1 ring silent callback mode
03 – Instant Activation mode
09 – 1 Ring, Fire siren Shutdown
10 – One Ring Silent Fire Shutdown
11 – Instant Activation, Fire Siren Shutdown
22 – AVM Time-out (activation time) (030 to 300 seconds in 2 second increments)
23 – AVM Code (Blank/0001 to 9998, do not program this)
24 – HOM Setup
25 – Time Zone
05 – Eastern Time
06 – Central Time
07 – Mountain Time
08 – Pacific Time
10 – Hawaii Time
Functions (can be enabled at keypad or by CS-4000, normally not needed)

F00 ON = Remote Phone Access Enabled after 12 rings OFF = Remote Access Disabled
F01 ON = Ring/Hang/Ring enabled (download or phone) OFF = Answers only after 12 rings
F02 ON = Exterior Siren sounds 15 seconds after alarm OFF = Sounds immedately
F03 ON = Phone/Download access after 8 rings OFF = Access after 12 rings
F04 ON = RF Low Battery reports once a week OFF = Low Bat once per day
F05 ON = Sensor Supervisory reports once a week OFF = Once per day
F06 ON = Dialer Aborts during alarm if disarmed OFF = Reports even if disarmed
F07 ON = # is Phone Access key OFF = * is Phone Access key
F11 ON = Hardwire interior siren sounds alarm OFF = Sounds Alarm & Status
F12 ON = Alarm Restoral Reports enabled OFF = Disabled
F13 ON = Low RF Battery Restoral Reports enabled OFF = Disabled
F14 ON = Hourly Phone Test enabled (TLM) OFF = Disabled
F15 ON = Alarm Verification (2 zones must trip for report) OFF = Disabled
F16 ON = RF Trouble Beeps but allows Arming OFF = Will not allow arming
F17 ON = Sensor Tamper causes Alarm OFF = Disabled
F20 ON = AVM Interrogator Active OFF = AVM is Disabled
F21 ON = Immediate Trouble Beeps OFF = Trouble Beeps in 10 Hours
F22 ON = DTM Disaling enabled OFF = Pulse Dialing Enabled
F23* ON = Arm/Disarm & Time Change to Event Buffer OFF = All Events saved to Event Buffer
F25 ON = Keyfob arms to level 3 OFF = Keyfob arms level 1, 2 then 3
F32 ON = Keyfob * arms no delay OFF = Turns ESM On or Off
F33 ON = Downloader Access enabled OFF = Disabled
F35 ON = Phone Panics enabled (*7777, *8888, *9999) OFF = Disabled
F36 ON = Local Phone Access enabled OFF = Access disabled
F37 ON = Quick-Arm enabled OFF = Quick-Arm disabled
F40* ON = Fire Zone must trip twice for Alarm OFF = Only trips once for Alarm
F41 ON = Interior Siren Trouble shows on Keypad OFF = Interior Siren not Supervised
F42 ON = Sensor 70 to 80 Alarm tracking enabled OFF = Disabled
F43* ON = Demo Kit Enabled OFF = Disabled
F44* ON = Exterior Siren Latched when in Alarm OFF = Disabled
F45* ON = Zone 1 Keyswitch Arm/Disarm OFF = Zone 1 Normal
F46* ON = Daylight Savings Enabled OFF = Disabled
F47 ON = 4-Hour Silence on Fire Troubles OFF = Disabled
* = UltraGard v2 Only
Upper Sensor Numbers
77 = Touchpad Tamper
78 = Freeze Sensor
79 = No Activity
80 = Keypad Fire
81 = Keypad Police
82 = Keypad Medical/Aux
83 = Phone Test
84 = Opening Report
85 = Closing Report
86 = Duress Alarm
87 = Force Arm
88 = Energy Saver Enable
89 = RF Touchpad Supervisory or Low Battery
90 = AC Power Failure
91 = Low Panel Battery
92 = Panel Tamper
93 = Auto Phone Test
94 = Wireless Receiver Failure
95 = CPU Back in Service (AC Restoral)
96 = Phone Failure
98 = Events Report
CS-4000 Commands
ACCT or ACCOUNT <XX-XX> Account Number (0 as 1st digit if 4-digit account)
ACCESS <4-digits> Programs Master Code
ALARMQ Views last 6 events of Alarm history
ANS 1 Connects CS-4000 to Panel
BATTLIFE <1 to 30> Battery Life? in Hours
BYPASS or BYP (00 to 16) Bypasses Sensors
CPUTIME (SET/STATUS) SET Sets panel time, STATUS reads panel time
DELETE or DEL (00 to 16) Deletes Sensors
DURESS <00 to 99> Hostage/Duress Code (usually 99)
ENTRY <8 to 88> Entry Delay (seconds)
EXIT <8 to 88> Exit Delay (seconds)
GROUP <zone> <zone type> Changes Zone type

Freeze GROUP <zone> 01 L
Fire GROUP <zone> 02 D
Delay GROUP <zone> 04 L
Instant GROUP <zone> 05 L
Interior Inst Follower GROUP <zone> 06 L
Interior Follower GROUP <zone> 06 I
Silent Police Panic GROUP <zone> 12 A
Audible Medical Panic GROUP <zone> 01 B
HOUSE <1 to 255> Views House Code
INIT <00 to 16> Initializes Sensors
MACCESS <2 to 6> <4 digits> Programs Secondary Codes
(Commander 8 only has 1 secondary Code)
PLOCK ???? %XXXXXXXX Changes Installer Code
???? = Old Installer Code
XXXX = New Installer Code Twice
PFORMAT <0 to 2> Report Format (0=ITI, 1=4×2, 1400hz, 2=4/2, 2300hz)
PHONE <7 to 4 digits> Primary Receiver (D = Pause)
PHONE2 <7 to 4 digits> Secondary Receiver (Commander 17 only)
PLEVEL <1 to 3> Changes Arming Level
PLEVEL 1 = Disarm
PLEVEL 2 = Arm Home
PLEVEL 3 = Arm Away
RECALL Has panel disconnect then call back
REL Releases Panel from CS-4000
SIREN <1 to 9> Siren Timeout in Minutes
STIME <hh:mm> Supervisory Report Time
UPD Sends updated programming to panel
ZONES Lists all Zones including Panics & Supervisory