GE / ITI / UC Caretaker Plus Program

Frequency 319.5 MHZ Range 1000 Feet Open Air
Downloading For Toolbox download add Download number as Receiver Number and do phone
test or call panel while tech doing phone test, or use CS-4000 with Phone Test
Format ITI Format, 4/2 2300 Hz, 4/2 1400 Hz (always use ITI)
Enter Program 1. Open Main Panel Cover by removing 2 bottom screws
2. Move Tamper switch to NORMAL setting, keypad shows “Program Mode”
(Opening cover may be enough by itself to enter programming)
Program Options
BYPASS moves down through Program Fields
STATUS moves up through Program Fields
COMMAND enters a Program Field
Enter data desired then COMMAND to save (Keypad blinks “OK”)
FIRE exits Program Field
Exit Program Set Tamper Switch back to RUN or close Panel Cover
Defaul Panel Press and hold MEMORY CLEAR in panel for 3 seconds (only as last resort!)
Signal Strength User Code + STATUS + 9 (tests signal strength)

Program
Fields
BYPASS moves forward STATUS moves back COMMAND enters and saves FIRE exits
Phone Number Up to 18 digits
Phone Format ITI Format (BYPASS or STAY to toggle)
Siren Time Out Enter 06 (01 to 15) minutes)
Duress Code Enter 99 (Duress = 1st 2-digits of code + 99)
Account Number Enter last 5 digits of Account (no letters)
Entry Delay 1 Enter 2-digits in seconds (08 to 88 seconds)
Entry Delay 2 Enter 2-digits in minutes (1 to 8 minutes)
Exit Delay 2-digit Exit Delay (08 to 88 seconds)
Activity Timeout Normally do not program (01 to 24 hours)
House Code Normally do not program (001 to 254)
Freeze Temp Normally do not program (40 to 90 degrees)
Loop IS Nc Normally do not program (Sets Keypad Zone NO or NC)
Unit Number Normally do not program
Touchpad Quiet Quiets Keypad Beeps (COMMAND toggles Yes/No)
Chime Display Normally do not program (COMMAND toggles Yes/No)
Send Test Normally do not program (Sends Zone Text to other keypads)
Load Test Normally do not program (I have no idea what this does)
Delete Text Normally do not program
Program Sensor Text Normally do not program (See bottom of this page)
Learn Sensors 1. Press COMMAND to enter (Display shows “Learn Group _ _”)
2. Enter Group number (01-29, 32) then COMMAND again

Click HERE for complete list of Sensor Types

3. Display shows LEARN Sn01, to learn different Sensor press 01 to 32
4. If this is correct sensor press COMMAND, display reads “TRIP sn”
5. Trip tamper on sensor, speaker will say “SENSOR ONE OKAY, SENSOR TWO”
6. Learn another sensor within this group or FIRE to exit to “LEARN GROUP”
7. Press FIRE again to exit back to “LEARN SENSORS” display

Delete Sensors 1. Press COMMAND to enter (Display shows “DELETE SnXX”)
2. Enter sensor to delete (01-29, 32)
3. Press COMMAND (Display shows “DEL SnXX OK”)
4. Press FIRE again to exit back to “DELETE SENSORS” display
Click HERE for complete list of Sensor Types
Upper Sensors Normally do not program
1. Press COMMAND to enter
2. Press STATUS/BYPASS to move UP/DOWN Sensor numbers
Press COMMAND to toggle ON/OFF

Upper Sensor Numbers
77 = Touchpad Tamper
78 = Freeze Sensor
79 = No Activity
80 = Keypad Fire
81 = Keypad Police
82 = Keypad Medical/Aux
83 = Phone Test
84 = Enable/Disable Openings
85 = Enable/Disable Closings
86 = Duress Alarm
87 = Force Arming
88 = Energy Saver Enable
89 = RF Touchpad Supervisory or Low Battery
90 = AC Power Failure
91 = Low Panel Battery
92 = Panel Tamper
93 = Auto Phone Test
94 = Wireless Receiver Failure
95 = CPU Back in Service (AC Restoral)
96 = Phone Failure
Learn Touchpad
1. Press COMMAND to enter (Display shows “Press TO01 BYP”)
2. Press BYPASS on touchpad (Display shows “Press TP02 BYP”)
3. Program next Touchpad or FIRE to exit to “LEARN TOUCHPAD” display
(Anytime this section is entered all existing learned touchpads are erased)
Functions (can only be enabled by CS-4000 except F22, normally not needed)
Function Description Default
F00 ON = Remote Phone Access Enabled ON
F01 ON = Ring twice/Hang/Ring enabled ON
F02 ON = Exterior Siren sounds 15 seconds after alarm OFF
F03 ON = Toll Saver ON
F04 ON = Low Battery reports ON
F05 ON = Sensor Supervisory reports ON
F06 ON = Dialer Aborts during alarm if disarmed ON
F07 ON = Access Key Type * (OFF), or # (ON) OFF
F11 ON = Hardwire interior siren sounds alarm OFF
F12 ON = Alarm Restoral Reports OFF
F13 ON = Low RF Battery Restoral Reports OFF
F14 ON = Hourly Phone Test OFF
F15 ON = Alarm Verification (2 zones must trip b4 report) OFF
F16 ON = Trouble Beeps OFF
F17 ON = 24 Hr Sensor Tamper causes Alarm OFF
F21 ON = Immediate Trouble Beeps OFF
F22 ON = DTMF Dialing OFF
(This can be done at keypad by entering *022
F25 ON = Keyfob Arming OFF
F32 ON = Energy Saver/No Delay OFF
F33 ON = Downloader Access enabled OFF
ITI Caretaker+ Alpha Zone Description Programming
(Each zone description can be up to 10 words or characters)

1. Use Stay or BYPASS to move to “PROGRAM SENSOR TEXT”
2. Press COMMAND to enter (Display shows “Sn _ _”)
3. Enter 2 digit zone (01-29, 32) (Display shows current description)
4. Press COMMAND (Display shows “A 00” (first word))
5. Enter 1st 2-digit word (see below listl)
6. Press COMMAND to save (Display shows “B 00” (second word)
7. Enter 2nd 2-digit word then COMMAND to save (Display shows “C 00” (Third word)
7. Continue until finished, press FIRE and display shows new complete Zone Description
8. Press BYPASS to move to next zone or FIRE to exit to “PROGRAM SENSOR TEXT”
(Use 00 to delete word or character, 27 inserts Space)

Word > Entry Word > Entry
Area 40 Library 70
Attic 41 Living 71
Basement 42 Main 72
Bathroom 43 Master 73
Bedroom 44 Mat 74
Bottom 45 Medical 75
Breezeway 46 Motion 76
Cabinet 47 North 77
Carpet 48 Office 78
Closet 49 Panic 79
Den 50 Patio 80
Desk 51 Police 81
Dining 52 Pool 82
Door 53 Porch 83
Drawer 54 Rear 84
East 55 Room 85
Entry 56 Safe 86
Family 57 Screen 87
Fire 58 Second 88
First 59 Sensor 89
Floor 60 Shock 90
Freeze 61 Side 91
Front 62 Sliding 92
Gallery 63 Smoke 93
Garage 64 Sound 94
Hall 65 South 95
Heat 66 Stairs 96
Kitchen 67 Top 97
Laundry 68 West 98
Level 69 Window 99

Character > Entry         Character > Entry
Null 00 U 21
A 01 V 22
B 02 W 23
C 03 X 24
D 04 Y 25
E 05 Z 26
F 06 (SPACE) 27
G 07 ‘ (Apostophe) 28
H 08 – (Dash) 29
I 09 0 30
J 10 1 31
K 11 2 32
L 12 3 33
M 13 4 34
N 14 5 35
O 15 6 36
P 16 7 37
Q 17 8 38
R 18 9 39
S 19
T 20
CS-4000 Commands

ACCT or ACCOUNT <XX-XX> Account Number (0 as 1st digit if 4-digit account)
ACCESS <4-digits> Programs Master Code
ALARMQ Views last 6 events of Alarm history
ANS 1 Connects CS-4000 to Panel
BATTLIFE <1 to 30> Battery Life? in Hours
BYPASS or BYP (00 to 16) Bypasses Sensors
DELETE or DEL (00 to 16) Deletes Sensors
DURESS <00 to 99> Hostage/Duress Code (usually 99)
ENTRY <8 to 88> Entry Delay (seconds)
EXIT <8 to 88> Exit Delay (seconds)
GROUP <zone> <zone type> Changes Zone type (Commander 17 2.6 only)

Freeze GROUP <zone> 01 L
Fire GROUP <zone> 02 D
Delay GROUP <zone> 04 L
Instant GROUP <zone> 05 L
Interior Inst Follower GROUP <zone> 06 L
Interior Follower GROUP <zone> 06 I
Silent Police Panic GROUP <zone> 12 A
Audible Medical Panic GROUP <zone> 01 B
HOUSE <1 to 255> Views House Code
INIT <00 to 16> Initializes Sensors
MACCESS <2 to 6> <4 digits> Programs Secondary Codes
(Commander 8 only has 1 secondary Code)
OPTION <20 to 27> <ON or OFF> Turns Functions ON/OFF (xx = 20 to 27)

F20 ON = Enable Interrogator OFF = Disables
F21 ON = DC Power Monitored OFF = Not Monitored
F22 ON = Dialing Format OFF = Pulse
F23 ON = Retain O/C only OFF = Retain All Events
F24 ON = Hardwire Loop NO OFF = Normally Closed OFF
F26 ON = Quick Disarm Enabled OFF = Disabled
F27 ON = Panel Alarm Mute OFF = Alarm Output Normal
Note: F20 and F27 must be ON for Interrogator
PLOCK ???? %XXXXXXXX Changes Installer Code
???? = Old Installer Code
XXXX = New Installer Code Twice
PFORMAT <0 to 2> Report Format (0=ITI, 1=4×2, 1400hz, 2=4/2, 2300hz)
PHONE <7 to 4 digits> Primary Receiver (D = Pause)
PHONE2 <7 to 4 digits> Secondary Receiver (Commander 17 only)
PLEVEL <1 to 3< Changes Arming Level
PLEVEL 1 = Disarm
PLEVEL 2 = Arm Home
PLEVEL 3 = Arm Away
RECALL Has panel disconnect then call back
REL Releases Panel from CS-4000
SIREN <1 to 9> Siren Timeout in Minutes
STIME <hh:mm> Supervisory Report Time
UPD Sends updated programming to panel
ZONES Lists all Zones including Panics & Supervisory