GE / ITI / UC Caretaker Plus Basics
Zones | 40 total, 6 Hardwired, 34 Wireless | ||||||||
AC Transformer | 9 volts, is screwed into outlet somewhere in house | ||||||||
Batteries |
|
||||||||
Downloadable | Yes, Customer must be home to answer phone | ||||||||
Panic Buttons |
3 on Keypad for Police, Fire, and Medical or From Telephone Press ****** Police Panic OR Press * + 88888 Police Panic Press * + 77777 Fire Panic Press * + 99999 Medical Panic |
||||||||
System can be Armed/Disarmed from Keypad or Touch-Tone Telephone | |||||||||
Arm Away |
4-digit User Code + 3 (AWAY) “Alarm System is ON, Level 3..” or from Phone enter * + User Code + 3 |
||||||||
Arm Stay |
4-digit User Code + 2 (STAY) “Alarm System is ON, Level 2..” or from Phone enter * + User Code + 2 |
||||||||
Arm Instant |
1. Am system In STAY or AWAY 2. Within Exit Delay press 4 “NO DELAY” or from Phone enter * + User Code + 2 or 3 + 4 |
||||||||
Disarm |
4-digit User Code + 1 “Alarm System is OFF, Level 1..” or from Phone enter * + User Code + 1 |
||||||||
Silence Alarm |
4-digit User Code + 1 Press STATUS to clear display or from Phone enter * + User Code + 1 |
||||||||
Alarm Memory | Press COMMAND then STATUS | ||||||||
Status |
Press STATUS, panel announces status and any open zones or from Phone enter * then # |
||||||||
Detailed Status |
Press STATUS twice or from Phone enter * + User Code + # + 1 or * + # + # |
||||||||
Bypass |
1. Arm in STAY or AWAY 2. Press BYPASS 3. Enter Sensor (01 to 40) “Sensor XX Bypassed” or from Phone enter * + User Code + 6 + Sensor (01 to 40) |
||||||||
Force Bypass |
1. Open Door or Window 2. Arm in STAY or AWAY “Protest, Zone XX Open” 3. At “Protest” press BYPASS “Alarm System is OFF, Level 1..” |
||||||||
Reset Smoke |
4-digit User Code + 1 “Alarm System is OFF, Level 1..” or from Phone enter * + User Code + 1 |
||||||||
Door Chimes |
4-digit User Code + 7 “Chime ON!” or “Chime OFF!” or from Phone enter * + User Code + 7 or COMMAND + 7 |
||||||||
Phone Test | 4-digit User Code + 8 “Phone Test Failure” or “Phone Test OK” | ||||||||
Sensor Test |
1. Press Master Code + 9 “9 – Sensor Test” 1a. If using Phone * + Master Code + # + 9 and leave phone off hook 2. Open each door or window, walk past motion, trip smoke sensors 3. When all sensors tested “All Sensors Test ok” 4. Press Master Code + 1 (OFF) to end (Wireless motions require no movement for 4 minutes prior to testing) |
||||||||
Signal Strength | User Code + STATUS + 9 (Tests sensor sensitivity) | ||||||||
Disable Keypad/ Phone |
# + User Code + * + 6 (This will disable phone commands until phone is hung up) | ||||||||
Energy Saver |
(For thermostats etc) User Code + 5 (Toggles ON and OFF) User Code + STATUS + 3 (Sets Energy Saver Low Temp Set Point) User Code + STATUS + 4 (Sets Energy Saver High Temp Set Point) |
||||||||
Light Control |
User Code + 0 to turn ON and OFF or COMMAND + 0 |
||||||||
Keypad Display | Press and hold COMMAND to Brighten or Dim LCD Display | ||||||||
Volume Adjust |
Locate speaker volume adjustment on panel (round pot with slot in middle Press COMMAND + STATUS, turn pot clockwise or counter-clockwise |