GE / ITI / UC Commander 2000 Trouble
POWER Light ON | Normal | ||||||||||||||||||||||||||||||||||||||
POWER OFF | AC power is off and panel is running on Backup Battery | ||||||||||||||||||||||||||||||||||||||
POWER FLASHING |
Backup Batteries Low (See Keypad Diagram (Replace with same type, Lithium with Lithium, or it WILL be messy!) |
||||||||||||||||||||||||||||||||||||||
TROUBLE ON |
(Press STATUS see list below for troubles)
|
||||||||||||||||||||||||||||||||||||||
Reset Smoke | 4-digit code + 1 (OFF) | ||||||||||||||||||||||||||||||||||||||
Phone Test |
|
||||||||||||||||||||||||||||||||||||||
Sensor Test |
1. Enter Master Code + 9 (Keypad says “Sensor Test is ON”) 2. Open Doors/Windows/walk past motion, press TEST on Smoke Det. 3. Keypad will beep and say “Sensor xx is OK” (if zone has a problem or is open it will not beep) 4. Press Master Code + 1 (OFF) to end Sensor Test |
||||||||||||||||||||||||||||||||||||||
Zone Trouble |
If zone is showing trouble customer can remove from system 1. Loosen 2 screws under keypad, lower bottom tray just a little bit 2. Press 4321 3. Press BYPASS + 2-digit zone number 4. Panel will say “Sensor xx Goodbye” 5. Raise bottom tray and tighten screws to exit |
||||||||||||||||||||||||||||||||||||||
Sensor 97 Trouble |
Hardwire Siren sensor supervision trouble, 4.7K resistor must be across siren terminals 13 & 14 |
||||||||||||||||||||||||||||||||||||||
Main Trouble and Event signals | |||||||||||||||||||||||||||||||||||||||
|