Default Panel |
POLICE + POLICE + MEDICAL + MEDICAL |
(“Memory Goodbye”) |
House Code |
FIRE + FIRE + [001 to 254] |
(Use only with X-10 devices) |
Duress Code |
POLICE + POLICE + [00 to 99] |
(use 99) (“xx OK!”) |
Siren Timeout |
MEDICAL + MEDICAL + [2 to 9] minutes |
(“xx OK!”) |
Entry Delay |
POLICE + POLICE + STATUS + [8 to 88 sec] |
(“xx OK!”) |
Exit Delay |
POLICE + POLICE + BYPASS + [8 to 88 sec] |
(“xx OK!”) |
Account Number |
FIRE + FIRE + STATUS + Last 5 of Account
(A to F can only be added by CS-4000 Receiver)
|
(0 as 1st digit if 4-digit account) |
Receiver Number |
FIRE + FIRE + BYPASS + [up to 18 digits]
(If you cannot change this Phone Lock is enabled)
|
(for pause press FIRE FIRE) |
Read Phone |
FIRE + FIRE + BYPASS |
(“Phone 1 8 x x etc”) |
Delete Phone |
FIRE + FIRE + BYPASS + 1 |
(“Phone OFF”) |
Report Format |
COMMAND + AUX + AUX + [00 to 03] |
00 = ITI (Default)
01 = 4/2 2300 HZ
03 = 4/2 1400 Hz
|
Installer Code |
AUX + AUX + BYPASS + New Code twice |
(Also enables Phone Lock) |
Hear All Sensors |
Press STATUS |
Do not use Simon sensors with AA batteries, use only older “Crystal” 3.5 Lithium Sensors! |
Learn Sensor |
1. Press STATUS + Group [00 to 29] |
(Keypad says “Sensory Level xx”) |
|
Common Groups |
01 = Audible Panic |
17 = Motions |
03 = Silent Panic |
20 = Delayed Motion |
10 = Entry Exit |
26 = Fire |
13 = Instant |
|
|
CLICK HERE FOR COMPLETE LIST OF SENSOR TYPES |
|
2. Enter Zone Number [01 to 17] |
(Keypad says “Sensor xx”) |
|
3. Learn sensor by doing the following
Door Sensor |
Remove cover (hardwired contacts learn while open) |
Glassbreaks |
Make a lot of noise (keys, clap etc) |
Motions |
Remove cover, may require pressing button |
Heat Sensor |
Rub hands until warm, place on sensor 30 seconds |
Smoke |
Hold Test button 30 seconds until Panel beeps |
Keyfobs |
Hold LOCK and UNLOCK buttons 3 seconds |
Touchpads |
Press BYPASS button for 3 seconds |
Hardwired Zn 18 |
If normally closed sensor learn with door open (close then open) |
If normally open sensor learn with door closed (open then close) |
|
|
4. If learned correctly keypad will say “Sensor OK” and go to next sensor
(Panel continues to learn in same group, to change group go back to step 1)
|
Erase Sensor |
Press BYPASS + Sensor [01 to 18] |
(Keypad says “Sensor xx Goodbye!”) |
Learn Keyfob |
1. Learn like standard Sensor using Group 01 (Audible Panic) or 03 (Silent Panic)
or
2. STATUS + STATUS + [1 to 4] + press LOCK & UNLOCK on keyfob
|
Delete Keyfob |
1. BYPASS + Sensor [01 to 17]
or 2. BYPASS + BYPASS [1 to 4]
|
(if learned by Step 1 above)
(if learned by Step 2 above)
|
Featured
Numbers
|
(Normally not needed, For Interrogator 2-way support turn ON F20 & F27)
(Press AUX + AUX + STATUS + [20 to 27] to Enable or Disable)
F20 |
ON = Interrogator support |
OFF = Disabled |
(Default=OFF) |
F21 |
ON = Battery power only |
OFF = AC Power |
(Default=OFF) |
F22 |
ON = Tone Dialing |
OFF = Pulse Dialing |
(Default=ON) |
F23 |
ON = Open/Close Reports |
OFF = Only in Event Buffer |
(Default=OFF) |
F24 |
ON = Hardwire Zone N/O |
OFF = N/C |
(Default=OFF) |
F26 |
ON = COMMAND 1 disarms |
OFF = Code Required |
(Default=OFF) |
F27 |
ON = Panel Sounds disabled |
OFF = Sounds enabled |
(Default=OFF) |
|
Signals ITI |
01 to 18 |
Zone alarms |
80 |
Touchpad Fire Panic |
81 |
Touchpad Police Panic |
82 |
Touchpad Auxiliary Panic |
83 |
Phone Test (Level 8) |
84 |
Opening Report (Optional) |
85 |
Closing Report (Optional) |
86 |
Duress Alarm Report |
87 |
Force Armed/ Auto Force Arm |
90 |
AC Failure |
91 |
Low Battery |
92 |
CPU Tamper |
93 |
Auto Phone Test |
94 |
Receiver Failure |
95 |
CPU Back in Service (AC Restored) |
96 |
Fail To Communicate |
97 |
Wiring problem with Exterior Siren (v5.3 only) |
98 |
Auto Event Buffer |
|
Signals 4/2 |
Description |
Zone |
Alarm |
Trouble |
Cancel |
Restore |
Wireless |
01 |
01 |
B1 |
39 |
Wireless |
02 |
02 |
B2 |
40 |
Wireless |
03 |
03 |
B3 |
41 |
Wireless |
04 |
04 |
B4 |
42 |
Wireless |
05 |
05 |
B5 |
43 |
Wireless |
06 |
06 |
B6 |
44 |
Wireless |
07 |
07 |
B7 |
45 |
Wireless |
08 |
08 |
B8 |
46 |
Wireless |
09 |
09 |
B9 |
47 |
Wireless |
10 |
10 |
C0 |
48 |
Wireless |
11 |
11 |
C1 |
49 |
Wireless |
12 |
12 |
C2 |
50 |
Wireless |
13 |
13 |
C3 |
51 |
Wireless |
14 |
14 |
C4 |
52 |
Wireless |
15 |
15 |
C5 |
53 |
Wireless |
16 |
16 |
C6 |
54 |
Wireless |
17 |
17 |
C7 |
55 |
Hardwire |
18 |
18 |
C8 |
56 |
Keypad Fire |
80 |
|
|
F2 |
Keypad Police |
81 |
81 |
F3 |
Keypad Medical |
82 |
82 |
F4 |
Phone Test |
83 |
83 |
Opening |
84 |
84 |
Closing |
85 |
95 |
Duress |
86 |
86 |
Force Arm |
87 |
87 |
RF low Battery |
89 |
|
F9 |
AC Failure |
90 |
90 |
|
|
FC |
Panel Low Batt |
91 |
91 |
|
|
FD |
Panel Tamper |
92 |
92 |
|
F3? |
Auto Phone Test |
93 |
93 |
Receiver Failure |
94 |
94 |
Back in Service |
95 |
95 |
Phone Failure |
96 |
97 |
Auto Event Dump |
98 |
98 |
|