Optex Morse Spectra Trouble

MEM Light
OFF = Normal
ON = Alarm Occured
BYP Light
OFF = No Zones are Bypassed
ON = One or more Zones are Bypassed
TRBL Light
OFF = Normal
ON = Trouble
4 Beeps in 3 seconds = Keypad Fault
View Trouble Press TRBL button, Zone Light will turn ON showing trouble
1 = Low Battery
2 = Low Wireless Battery (Zone Light shows sensor)
3 = AC Power Failure
4 = Siren Missing
5 = Siren Failure
6 = Aux Power Trouble
7 = Communication Failure
8 = Loss of Clock
9 = Tamper/Zone Wiring Failure (Press 9 to show which Zone)
10 = TLM Telephone Line Failure
11 or STAY = Fire Zone Failure
12 or BYP = Module Lost
13 or MEM = Wireless Zone Failure (Press MEM to show sensor)
14 or FORCE = A Keypad has a Trouble

Press CLEAR to exit

Set Time/Date 1. Press ENTER button
2. Enter Master Code + 100
3. Enter 4-digit Military Time (1:30PM would be 13:30)
4. Press CLEAR to Exit
Phone Test Press ENTER button + Master Code + MEM button