Optex Morse Spectra Program

Answer Download ENTER + Installer Code + FORCE
Call Downloader ENTER + Installer Code + BYP
Enter Program ENTER + Installer Code (Enter will Blink)
(Default = 000000, if 4 digit codes are used then Default = 0000)
Exit Program Press CLEAR
Move to Location Enter 3-digit Location
Erase Location FORCE three times then ENTER
Exit without Save CLEAR
Save Data ENTER (also advances to next location)
Hex Program 0 = A STAY = B BYP = C MEM = D TRBL = E PG or FNC1 = F

Zone Programming   Enter 3 digits, ENTER saves and move to next
001 Zone 1 Definitions I_?_I_?_I_?_I
Digit 1 = Zone Type
EMPTY = Zone Disabled
1 = Entry Delay 1
2 = Entry Delay 2
3 = Interior Follower
4 = Instant
5 = 24 Hr Burg
24 Hr Fire if Zn 3
6 = 24 Hr Buzzer
Delayed Fire if Zn 3

Digit 2 = Partition
EMPTY = Zone Disabled
1 = Partition 1
2 = Partition 2
3 = Both Partitions

Digit 3 = Options (Toggle Option)
1 ON = Auto Zone Shutdown
2 ON = Bypassable Zone
3 ON = Stay Zone
4 OFF 5 OFF = Audible (Steady)
4 OFF 5 ON = Audible (Pulsed)
4 ON 5 OFF = Silent Alarm
4 ON 5 ON = Report Only
6 ON = Intellizone
7 ON = Delay Alarm Transmission
8 ON = Force Zone
002 Zone 2 Definitions I_?_I_?_I_?_I
003 Zone 3 Definitions I_?_I_?_I_?_I
004 Zone 4 Definitions I_?_I_?_I_?_I
005 Zone 5 Definitions I_?_I_?_I_?_I
006 Zone 6 Definitions I_?_I_?_I_?_I
007 Zone 7 Definitions I_?_I_?_I_?_I
008 Zone 8 Definitions I_?_I_?_I_?_I
009 Zone 9 Definitions I_?_I_?_I_?_I
010 Zone 10 Definitions I_?_I_?_I_?_I
011 Zone 11 Definitions I_?_I_?_I_?_I
012 Zone 12 Definitions I_?_I_?_I_?_I
013 Zone 13 Definitions I_?_I_?_I_?_I
014 Zone 14 Definitions I_?_I_?_I_?_I
015 Zone 15 Definitions I_?_I_?_I_?_I
016 Zone 16 Definitions I_?_I_?_I_?_I
050 Zone 1 Loop Speed I_0_I_6_I_0_I (001 to 255 x10ms, normally leave alone)
051 Zone 2 Loop Speed I_0_I_6_I_0_I (001 to 255 x10ms, normally leave alone)
052 Zone 3 Loop Speed I_0_I_6_I_0_I (001 to 255 x10ms, normally leave alone)
053 Zone 4 Loop Speed I_0_I_6_I_0_I (001 to 255 x10ms, normally leave alone)
054 Zone 5 Loop Speed I_0_I_6_I_0_I (001 to 255 x10ms, normally leave alone)
055 Zone 6 Loop Speed I_0_I_6_I_0_I (001 to 255 x10ms, normally leave alone)
056 Zone 7 Loop Speed I_0_I_6_I_0_I (001 to 255 x10ms, normally leave alone)
057 Zone 8 Loop Speed I_0_I_6_I_0_I (001 to 255 x10ms, normally leave alone)
058 Zone 9 Loop Speed I_0_I_6_I_0_I (001 to 255 x10ms, normally leave alone)
059 Zone 10 Loop Speed I_0_I_6_I_0_I (001 to 255 x10ms, normally leave alone)
060 Zone 11 Loop Speed I_0_I_6_I_0_I (001 to 255 x10ms, normally leave alone)
061 Zone 12 Loop Speed I_0_I_6_I_0_I (001 to 255 x10ms, normally leave alone)
062 Zone 13 Loop Speed I_0_I_6_I_0_I (001 to 255 x10ms, normally leave alone)
063 Zone 14 Loop Speed I_0_I_6_I_0_I (001 to 255 x10ms, normally leave alone)
064 Zone 15 Loop Speed I_0_I_6_I_0_I (001 to 255 x10ms, normally leave alone)
065 Zone 16 Loop Speed I_0_I_6_I_0_I (001 to 255 x10ms, normally leave alone)
066 PGM1 Timer I_0_I_0_I_5_I (0000 = Follow Stop Event – 005 = 5 sec)
067 PGM3 Timer I_0_I_0_I_5_I (0000 = Follow Stop Event – 005 = 5 sec)
068 Global PGM Timer I_0_I_0_I_5_I (0000 = Follow Stop Event – 005 = 5 sec)
069 Entry Delay 1 I_0_I_4_I_5_I (000 to 255 seconds)
070 Entry Delay 2 I_0_I_4_I_5_I (000 to 255 seconds)
071 Exit Delay 1 I_0_I_6_I_0_I (000 to 255 seconds)
072 Exit Delay 2 I_0_I_6_I_0_I (000 to 255 seconds)
073 Bell Cut-Off Time Partition 1 I_0_I_0_I_4_I (001 to 255 minutes)
074 Bell Cut-Off Time Partition 2 I_0_I_0_I_4_I (001 to 255 minutes)
075 No Movement Time Partition 1 I_0_I_0_I_0_I (000 = Disabled)
076 No Movement Time Partition 2 I_0_I_0_I_0_I (000 = Disabled)
077 Answer Machine Over-ride I_0_I_6_I_0_I (000 = disabled, 010 to 255 seconds)
078 Download Number of Rings I_0_I_0_I_8_I (000 = disabled, 001 to 15 rings)
079 TLM Fail Timer I_0_I_6_I_0_I (x2 seconds)
080 Delay Alarm Transmission I_0_I_0_I_8_I (Disabled)
081 Max Dialing Attempts I_0_I_0_I_8_I (8 Attempts, 000 = 16 Attempts)
082 Delay Between Dial Attempts I_0_I_2_I_0_I (20 seconds)
083 Pager Delay I_0_I_0_I_5_I (5 seconds)
084 Intellizone Delay I_0_I_4_I_8_I (48 seconds)
085 Recent Closing Delay I_0_I_0_I_0_I (Disabled)
086 AC Fail Report Delay I_0_I_6_I_0_I (60 minutes, default = 15)
087 Auto Test Report (Days) I_0_I_3_I_0_I (30 days, default = Disabled)
088 Clock Adjust I_0_I_0_I_8_I (Disabled)
089 Auto Zone Shutdown I_0_I_0_I_5_I (5 Alarms until shutdown)
090 Recycle Alarm Delay I_0_I_0_I_8_I (001 to 255 minutes)
091 Recycle Alarm Counter I_0_I_0_I_0_I (001 to 255)
110 Auto Test Report Time I_0_I_2_I_0_I_0_I (0000 Disables, 0001 to 2359)
111 Auto Arm Time Partition 1 I_0_I_0_I_0_I_0_I (0000 Disables, 0001 to 2359)
112 Auto Arm Time Partition 2 I_0_I_0_I_0_I_0_I (0000 Disables, 0001 to 2359)

Event Group Sub-Group Partition (01, 02 99 = Any)
120 PGM 1 Activation Event I_ _I_ _I I_ _I_ _I I_ _I_ _I
121 PGM 1 Deactivation Event I_ _I_ _I I_ _I_ _I I_ _I_ _I
122 PGM 2 Activation Event I_ _I_ _I I_ _I_ _I I_ _I_ _I
123 PGM 2 Deactivation Event I_ _I_ _I I_ _I_ _I I_ _I_ _I
124 Global PGM Activation Event I_ _I_ _I I_ _I_ _I I_ _I_ _I
125 Global PGM Deactivation Event
(Keypad and Expansion PGMs)
I_ _I_ _I I_ _I_ _I I_ _I_ _I
Example: Enable PGM on Partition 1 with any open opening would be 01 99 01

127 General Options (Toggle Options ON/OFF, ENTER saves and move to next Location)
Default Option ON Option OFF
OFF I_OFF_I 1 Partitioning Enabled Partitioning Disabled
ON I_ON_I 2 4-Digit Access Codes 6-digit Access Codes
ON I_ON_I 3 Keypad Troubles Audible Keypad Troubles Silent
OFF I_OFF_I 4 System Master Code Locked System Master Code Unlocked
OFF I_OFF_I 5 Battery Charge Current 700mA Battery Charge Current 350mA
OFF I_OFF_I 6 User Code 048 is Duress Code User Code 048 is Normal Code
OFF I_OFF_I 7 Alarm Relay Follows Global PGM Alarm Relay Follows Bell Output
OFF I_OFF_I 8 PGM1 is Normally Open PGM1 is Normally Closed

128 General Options (Toggle Options ON/OFF, ENTER saves and move to next Location)
Default Option ON Option OFF
OFF I_ON_I 1 Panic 1 (Police) Keys 1 & 3 Enabled Disabled
OFF I_ON_I 2 Panic 2 (Medical) Keys 4 & 6 Enabled Disabled
OFF I_ON_I 3 Panic 3 (Fire) Keys 7 & 9 Enabled Disabled
OFF I_ON_I 4 Panic 1 Audible Silent
OFF I_OFF_I 5 Panic 2 Audible Silent
OFF I_ON_I 6 Panic 3 Fire Enabled Silent or Disabled
OFF I_OFF_I 7 Keypad 1 Tamper Enabled Disabled
OFF I_OFF_I 8 Keypad 2 Tamper Enabled Disabled

129 General Options (Toggle Options ON/OFF, ENTER saves and move to next Location)
Default Option ON Option OFF
OFF I_OFF_I 1 PGM2 Output Activation Pulsed Steady
OFF I_OFF_I 2 PGM2 Pulse Once every 30 sec if Armed Disabled
OFF I_OFF_I 3 PGM2 Pulse on Arm, Twice on Disarm Disabled
OFF I_OFF_I 4 SPC-ZX4/8 Zone Expander Supervision Disabled
OFF I_OFF_I 5 SPC-319 Wireless Mod. Supervision Disabled
OFF I_OFF_I 6 SPC-319 Wireless Mod. Low Bat Superv Disabled
OFF I_OFF_I 7 Siren Driver on Bell Output External Siren Driver
OFF I_OFF_I 8 PGM2 Normally Open*
*1755, 1755EX, 1758, 1758EX only

PGM2 Normally Closed*

130 Arm/Disarm Options (Toggle Options ON/OFF, ENTER saves and move to next Location)
Default Option ON Option OFF
OFF I_ON_I 1 One-Touch Regular Arming Enabled Disabled
OFF I_ON_I 2 One-Touch Stay Arming Enabled Disabled
OFF I_OFF_I 3 One-Touch Force Arming Enabled Disabled
OFF I_OFF_I 4 One-Touch Bypass Program Enabled Disabled
OFF I_OFF_I 5 Restrict Arming on Battery Failure Disabled
OFF I_OFF_I 6 Restrict Arming on Tamper Trouble Disabled
OFF I_OFF_I 7 Bell Squawk on Arm/Disarm Disabled
ON I_ON_I 8 Beep on Exit Delay Enabled Disabled

131 Arm/Disarm Options (Toggle Options ON/OFF, ENTER saves and move to next Location)
Default Option ON Option OFF
ON I_ON_I 1 Report Disarm after Alarm (Cancel) Always
OFF I_OFF_I 2 Regular Arm switches to Force Arm Disabled
OFF I_OFF_I 3 Bell Squawk on Arm/Disarm w/Remote Disabled
OFF I_OFF_I 4 No Exit Delay if Armed with Remote Disabled
OFF I_OFF_I 5 No Exit Beeps/No Squawk if Stay Armed Disabled
OFF I_OFF_I 6 Restrict Arming on Wireless Superv Disabled
OFF I_OFF_I 7 Generate Supervision Loss if
Detected on Bypassed Wireless Zone
Disabled
OFF I_OFF_I 8 Global PGM Normally Open Normally Closed

132 Arm/Disarm Options (Toggle Options ON/OFF, ENTER saves and move to next Location)
Default Option ON Option OFF
OFF I_OFF_I 1 Tamper Recognition Options
OFF I_OFF_I 2 Click HERE for Options
OFF I_OFF_I 3 No Tamper if detected on Bypassed Zn Tamper Detected
OFF I_OFF_I 4 EOL Resistors Enabled No EOL Resistors
OFF I_OFF_I 5 ATZ Zone Doubling Enabled Disabled
OFF I_OFF_I 6 Report Zone Restore on Zone Closure Report on Bell Cut-off
OFF I_OFF_I 7 Wireless Transmitter Supervision Options
OFF I_OFF_I

8 Click HERE for Options
133 Partition 1 Options (Toggle Options ON/OFF, ENTER saves and move to next Location)
Default Option ON Option OFF
OFF I_OFF_I 1 Auto-Arm on Time Enabled Disabled
OFF I_OFF_I 2 Auto-Arm on No Movement Enabled Disabled
OFF I_OFF_I 3 Auto Arming = Stay Arming Regular Arming
OFF I_OFF_I 4 Switch to Stay Arming (Home/Away) Disabled (Spectra v2.0 only)
OFF I_OFF_I 5 Future Use
OFF I_OFF_I 6 Future Use
OFF I_ON_I 7 Switch to Stay if No Entry Dr Opened Disabled
OFF I_OFF_I 8 Future Use

134 Partition 2 Options (Toggle Options ON/OFF, ENTER saves and move to next Location)
Default Option ON Option OFF
OFF I_OFF_I 1 Auto-Arm on Time Enabled Disabled
OFF I_OFF_I 2 Auto-Arm on No Movement Enabled Disabled
OFF I_OFF_I 3 Auto Arming = Stay Arming Regular Arming
OFF I_OFF_I 4 Future Use
OFF I_OFF_I 5 Future Use
OFF I_OFF_I 6 Future Use
OFF I_OFF_I 7 Switch to Stay if No Entry Dr Opened Disabled
OFF I_OFF_I 8 Future Use

135 Dialer Options (Toggle Options ON/OFF, ENTER saves and move to next Location)
Default Option ON Option OFF
OFF I_OFF_I 1 TLM Options
OFF I_OFF_I 2 Click HERE for Options
OFF I_ON_I 3 Reporting Enabled Disabled (Local Alarm)
ON I_ON_I 4 Tone Dialing Pulse Dialing
ON I_ON_I 5 Pulse Ratio 1:1.5 (N. America) Pulse Ratio 1:2 (Europe)
OFF I_OFF_I 6 Bell on Com Failure if Armed Disabled
OFF I_OFF_I 7 Future Use
OFF I_OFF_I 8 Future Use

136 Dialer Options (Toggle Options ON/OFF, ENTER saves and move to next Location)
Default Option ON Option OFF
OFF I_OFF_I 1 Download Callback Enabled Disabled
OFF I_OFF_I 2 Auto Event Buffer Transmission Disabled
ON I_OFF_I 3 Contact ID Auto Report Codes* Contact ID Code Programmable*
OFF I_OFF_I 4 Alternate Dial Enabled Alternate Dial Disabled
OFF I_OFF_I 5 Hang-up if no dial tone after 16 sec Continue after 4 seconds
OFF I_OFF_I 6 Future Use
OFF I_OFF_I 7 Future Use
OFF I_OFF_I 8 Future Use
*Do not use Auto Reporting, it enables every Report Code

137 Event Call Direction (Toggle Options ON/OFF, ENTER saves and move to next Location)
Default Option ON Option OFF
ON I_ON_I 1 Call Phone 1 for Armings/Disarmings Disabled
OFF I_OFF_I 2 Call Phone 2 for Armings/Disarmings Disabled
ON I_ON_I 3 Call Phone 1 for Alarms/Restores Disabled
OFF I_OFF_I 4 Call Phone 2 for Alarms/Restores Disabled
ON I_ON_I 5 Call Phone 1 for Tampers/Restores Disabled
OFF I_OFF_I 6 Call Phone 2 for Tampers/Restores Disabled
OFF I_OFF_I 7 Future Use
OFF I_OFF_I 8 Future Use

138 Event Call Direction (Toggle Options ON/OFF, ENTER saves and move to next Location)
Default Option ON Option OFF
ON I_OFF_I 1 Call Phone 1 for Troubles/Restorals Disabled
OFF I_OFF_I 2 Call Phone 2 for Troubles/Restorals Disabled
ON I_ON_I 3 Call Phone 1 for Special Report Codes Disabled
OFF I_OFF_I 4 Call Phone 2 for Special Report Codes Disabled
OFF I_OFF_I 5 Future Use
OFF I_OFF_I 6 Furute Use
OFF I_OFF_I 7 Future Use
OFF I_OFF_I 8 Future Use

140 Reporting Formats I_5_I Phone 1
I_5_I Phone 2
1 = Ademco Slow (1400/1900Hz 10BPS)

2 = Silent Knight Fast (1400/1900Hz 20BPS)
3 = Sescoa (2300/1800 20BPS)
4 = Ademco Express (DTMF 4 + 2)
5 = Ademco Contact ID (Default)
6 = Pager
STAY = *
BYP = #
MEM = Toggle Pulse / Touch-Tone
TRBL = 4-second pause
FORCE = Delete current digit
PG or FNC1 = Insert blank space

141 Panel Identifier I_ _I_ _I_ _I_ _I (0000 to FFFF, Leave Blank)
142 PC Password (CSID) I_ _I_ _I_ _I_ _I (0000 to FFFF, Leave Blank)
143 Partition 1 Account Number I_ _I_ _I_ _I_ _I
144 Partition 2 Account Number I_ _I_ _I_ _I_ _I
150 Download Phone (32 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
151 Phone Number 1 (32 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
152 Phone Number 2 (32 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
153 Backup Phone Number I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I

STAY = *     MEM = Switch to Pulse or Tone Dialing     FORCE = Delete Digit
BYP = # TBL = 4-second Pause PG or FNC1 = Inserts Blank Space

160 Closing (Arming) Report Codes 1 to 4
I_0_I_0_I Access Code 1 I_0_I_0_I Access Code 3
I_0_I_0_I Access Code 2 I_0_I_0_I Access Code 4

161 Closing (Arming) Report Codes 5 to 8
I_0_I_0_I Access Code 5 I_0_I_0_I Access Code 7
I_0_I_0_I Access Code 6 I_0_I_0_I Access Code 8

162 Closing (Arming) Report Codes 9 to 12
I_0_I_0_I Access Code 9 I_0_I_0_I Access Code 11
I_0_I_0_I Access Code 10 I_0_I_0_I Access Code 12

163 Closing (Arming) Report Codes 13 to 16
I_0_I_0_I Access Code 13 I_0_I_0_I Access Code 15
I_0_I_0_I Access Code 14 I_0_I_0_I Access Code 16

164 Closing (Arming) Report Codes 17 to 20
I_0_I_0_I Access Code 17 I_0_I_0_I Access Code 19
I_0_I_0_I Access Code 18 I_0_I_0_I Access Code 20

165 Closing (Arming) Report Codes 21 to 24
I_0_I_0_I Access Code 21 I_0_I_0_I Access Code 23
I_0_I_0_I Access Code 22 I_0_I_0_I Access Code 24

166 Closing (Arming) Report Codes 25 to 28
I_0_I_0_I Access Code 25 I_0_I_0_I Access Code 27
I_0_I_0_I Access Code 26 I_0_I_0_I Access Code 28

167 Closing (Arming) Report Codes 29 to 32
I_0_I_0_I Access Code 29 I_0_I_0_I Access Code 31
I_0_I_0_I Access Code 30 I_0_I_0_I Access Code 32

168 Closing (Arming) Report Codes 33 to 36
I_0_I_0_I Access Code 33 I_0_I_0_I Access Code 35
I_0_I_0_I Access Code 34 I_0_I_0_I Access Code 36

169 Closing (Arming) Report Codes 37 to 40
I_0_I_0_I Access Code 37 I_0_I_0_I Access Code 39
I_0_I_0_I Access Code 38 I_0_I_0_I Access Code 40

170 Closing (Arming) Report Codes 41 to 44
I_0_I_0_I Access Code 41 I_0_I_0_I Access Code 43
I_0_I_0_I Access Code 42 I_0_I_0_I Access Code 44

171 Closing (Arming) Report Codes 45 to 48
I_0_I_0_I Access Code 45 I_0_I_0_I Access Code 47
I_0_I_0_I Access Code 46 I_0_I_0_I Access Code 48

172 Special Arming Codes
I_0_I_0_I Auto-Arming I_0_I_0_I No Movement
I_0_I_0_I Late to Close I_0_I_0_I Partial Arming

173 Special Arming Codes
I_0_I_0_I Quick Arming I_0_I_0_I Keyswitch Arming
I_0_I_0_I Arming via PC I_0_I_0_I N/A

174 Opening (Disarming) Report Codes 1 to 4
I_0_I_0_I Access Code 1 I_0_I_0_I Access Code 3
I_0_I_0_I Access Code 2 I_0_I_0_I Access Code 4

175 Opening (Disarming) Report Codes 5 to 8
I_0_I_0_I Access Code 5 I_0_I_0_I Access Code 7
I_0_I_0_I Access Code 6 I_0_I_0_I Access Code 8

176 Opening (Disarming) Report Codes 9 to 12
I_0_I_0_I Access Code 9 I_0_I_0_I Access Code 11
I_0_I_0_I Access Code 10 I_0_I_0_I Access Code 12

177 Opening (Disarming) Report Codes 13 to 16
I_0_I_0_I Access Code 13 I_0_I_0_I Access Code 15
I_0_I_0_I Access Code 14 I_0_I_0_I Access Code 16

178 Opening (Disarming) Report Codes 17 to 20
I_0_I_0_I Access Code 17 I_0_I_0_I Access Code 19
I_0_I_0_I Access Code 18 I_0_I_0_I Access Code 20

179 Opening (Disarming) Report Codes 21 to 24
I_0_I_0_I Access Code 21 I_0_I_0_I Access Code 23
I_0_I_0_I Access Code 22 I_0_I_0_I Access Code 24

180 Opening (Disarming) Report Codes 25 to 28
I_0_I_0_I Access Code 25 I_0_I_0_I Access Code 27
I_0_I_0_I Access Code 26 I_0_I_0_I Access Code 28

181 Opening (Disarming) Report Codes 29 to 32
I_0_I_0_I Access Code 29 I_0_I_0_I Access Code 31
I_0_I_0_I Access Code 30 I_0_I_0_I Access Code 32

182 Opening (Disarming) Report Codes 33 to 36
I_0_I_0_I Access Code 33 I_0_I_0_I Access Code 35
I_0_I_0_I Access Code 34 I_0_I_0_I Access Code 36

183 Opening (Disarming) Report Codes 37 to 40
I_0_I_0_I Access Code 37 I_0_I_0_I Access Code 39
I_0_I_0_I Access Code 38 I_0_I_0_I Access Code 40

184 Opening (Disarming) Report Codes 41 to 44
I_0_I_0_I Access Code 41 I_0_I_0_I Access Code 43
I_0_I_0_I Access Code 42 I_0_I_0_I Access Code 44

185 Opening (Disarming) Report Codes 45 to 48
I_0_I_0_I Access Code 45 I_0_I_0_I Access Code 47
I_0_I_0_I Access Code 46 I_0_I_0_I Access Code 48

186 Special Disarming Codes
I_0_I_0_I Cancel Auto-Arming I_0_I_0_I Keyswitch Disarm
I_0_I_0_I Disarming via PC I_0_I_0_I NA

187 Alarm Report Codes Zone 1 to 4
I_?_I_?_I Zone 1 I_?_I_?_I Zone 3
I_?_I_?_I Zone 2 I_?_I_?_I Zone 4

188 Alarm Report Codes Zone 5 to 8
I_?_I_?_I Zone 5 I_?_I_?_I Zone 7
I_?_I_?_I Zone 6 I_?_I_?_I Zone 8

189 Alarm Report Codes Zone 9 to 12
I_?_I_?_I Zone 9 I_?_I_?_I Zone 11
I_?_I_?_I Zone 10 I_?_I_?_I Zone 12

190 Alarm Report Codes Zone 13 to 16
I_?_I_?_I Zone 13 I_?_I_?_I Zone 15
I_?_I_?_I Zone 14 I_?_I_?_I Zone 16

191 Alarm Restore Report Codes Zone 1 to 4
I_0_I_0_I Zone 1 I_0_I_0_I Zone 3
I_0_I_0_I Zone 2 I_0_I_0_I Zone 4

192 Alarm Restore Report Codes Zone 5 to 8
I_0_I_0_I Zone 5 I_0_I_0_I Zone 7
I_0_I_0_I Zone 6 I_0_I_0_I Zone 8

193 Alarm Restore Report Codes Zone 9 to 12
I_0_I_0_I Zone 9 I_0_I_0_I Zone 11
I_0_I_0_I Zone 10 I_0_I_0_I Zone 12

194 Alarm Restore Report Codes Zone 13 to 16
I_0_I_0_I Zone 13 I_0_I_0_I Zone 15
I_0_I_0_I Zone 14 I_0_I_0_I Zone 16

195 Special Report Codes
I_1_I_0_I Emergency (Police) Panic* I_0_I_4_I Fire Panic
I_0_I_1_I Medical Panic
* if Police Panic Silent use 0F

I_0_I_0_I Recent Closing (Exit Alarm)
196 Special Report Codes
I_0_I_0_I Zone Shutdown I_0_I_0_I Future Use
I_0_I_E_I Duress I_0_I_0_I Future Use

197 Zone Trouble Report Codes Zone 1 to 4
I_0_I_0_I Zone 1 I_0_I_0_I Zone 3
I_0_I_0_I Zone 2 I_0_I_0_I Zone 4

198 Zone TroubleReport Codes Zone 5 to 8
I_0_I_0_I Zone 5 I_0_I_0_I Zone 7
I_0_I_0_I Zone 6 I_0_I_0_I Zone 8

199 Zone Trouble Report Codes Zone 9 to 12
I_0_I_0_I Zone 9 I_0_I_0_I Zone 11
I_0_I_0_I Zone 10 I_0_I_0_I Zone 12

200 Zone Trouble Report Codes Zone 13 to 16
I_0_I_0_I Zone 13 I_0_I_0_I Zone 15
I_0_I_0_I Zone 14 I_0_I_0_I Zone 16

201 Zone Trouble Restore Report Codes Zone 1 to 4
I_0_I_0_I Zone 1 I_0_I_0_I Zone 3
I_0_I_0_I Zone 2 I_0_I_0_I Zone 4

202 Zone Trouble Restore Report Codes Zone 5 to 8
I_0_I_0_I Zone 5 I_0_I_0_I Zone 7
I_0_I_0_I Zone 6 I_0_I_0_I Zone 8

203 Zone Trouble Restore Report Codes Zone 9 to 12
I_0_I_0_I Zone 9 I_0_I_0_I Zone 11
I_0_I_0_I Zone 10 I_0_I_0_I Zone 12

204 Zone Trouble Restore Report Codes Zone 13 to 16
I_0_I_0_I Zone 13 I_0_I_0_I Zone 15
I_0_I_0_I Zone 14 I_0_I_0_I Zone 16

205 System Trouble Report Codes
I_0_I_0_I Future Use I_3_I_4_I Battery Failure
I_3_I_3_I AC Failure I_0_I_0_I Auxiliary Supply

206 System Trouble Report Codes
I_0_I_0_I Bell Output Overload I_0_I_0_I Timer Loss
I_0_I_0_I Bell Output Disconnect I_5_I_4_I Fire Loop Trouble

207 System Trouble Report Codes
I_5_I_9_I Wireless Low Battery I_0_I_0_I Printer Fault
I_0_I_0_I Module Fault I_0_I_0_I Fail to Communicate

208 System Trouble Restore Report Codes
I_0_I_0_I TLM Restore I_0_I_0_I Battery Failure Restore
I_0_I_0_I AC Fail Restore I_0_I_0_I Auxiliary Supply Restore

209 System Trouble Restore Report Codes
I_3_I_E_I Bell Output Overload I_0_I_0_I Timer Programmed
I_3_I_E_I Bell Output Disconnect I_0_I_0_I Fire Loop Trouble Restore

210 System Trouble Report Codes
I_0_I_0_I Wireless Low Battery I_0_I_0_I Printer Fault Restore
I_0_I_0_I Module Fault Restore I_0_I_0_I Future Use

211 Special Report Codes
I_0_I_0_I Cold Start (Shutdown) I_0_I_0_I PC Call Back
I_7_I_9_I Test Report I_6_I_5_I PC Access

212 Special Report Codes
I_0_I_0_I Installer In I_0_I_0_I Future Use
I_0_I_0_I Installer Out I_0_I_0_I Future Use

213 System Trouble Report Codes
I_5_I_6_I Wireless Supervision Loss I_0_I_0_I Future Use
I_0_I_0_I Wireless Supervision Restore I_0_I_0_I Future Use

280 System Clock HH:MM I_?_I_?_I_?_I_?_I

Installer Code
281 Installer Code I_0_I_0_I_0_I_0_I_0_I_0_I
If Access Code length is set to 4 digits panel will add 1st 2 digits to last 2 digits
282 Installer Code Lock I_0_I_0_I_0_I   (147 = Locked, 000 = Unlocked)
301 System Master Code I_1_I_2_I_3_I_4_I_5_I_6_I
If Access Code length is set to 4 digits panel will add 1st 2 digits to last 2 digits

User Code Options   (Toggle Options ON/OFF, ENTER saves and move to next Location)
302 Master Code 1 Options
303 Master Code 2 Options Light 1 ON = Partition 1 Access
304 User Codes 004 Options Light 2 ON = Partition 2 Access
305 User Codes 005 Options Light 3 ON = Bypass Enable
306 User Codes 006 Options Light 4 ON = Stay Arming Enabled
307 User Codes 007 Options Light 5 ON = Force Arming Enabled
308 User Codes 008 Options Light 6 ON = Arm Only Code
309 User Codes 009 Options Light 7 ON = PGM Activation Code Only
310 User Codes 010 Options Light 8 ON = Not Used
311 User Codes 011 Options
312 User Codes 012 Options (Default is Lights 1, 3 and 4 ON)
313 User Codes 013 Options
314 User Codes 014 Options
315 User Codes 015 Options
316 User Codes 016 Options
317 User Codes 017 Options
318 User Codes 018 Options
319 User Codes 019 Options
320 User Codes 020 Options
321 User Codes 021 Options
322 User Codes 022 Options
323 User Codes 023 Options
324 User Codes 024 Options
325 User Codes 025 Options
326 User Codes 026 Options
327 User Codes 027 Options
328 User Codes 028 Options
329 User Codes 029 Options
330 User Codes 030 Options
331 User Codes 031 Options
332 User Codes 032 Options
333 User Codes 033 Options
334 User Codes 034 Options
335 User Codes 035 Options
336 User Codes 036 Options
337 User Codes 037 Options
338 User Codes 038 Options
339 User Codes 039 Options
340 User Codes 040 Options
341 User Codes 041 Options
342 User Codes 042 Options
343 User Codes 043 Options
344 User Codes 044 Options
345 User Codes 045 Options
346 User Codes 046 Options
347 User Codes 047 Options
348 User Codes 048 Options

640 Press ENTER to default Liberator Wireless Receiver Module

900 Copy from Paradox Memory Key to Control Panel

902 Copy from Control Panel to Paradox Memory Key