Paradox Digiplex Trouble

MEM Light
OFF = Normal
ON = Alarm Occured
BYP Light
OFF = No Zones are Bypassed
ON = One or more Zones are Bypassed
TRBL Light
OFF = Normal
ON = Trouble
View Trouble (Most of the below troubles will require service except Low Batteries and Clock)
1. Press TRBL button (TRBL Flashes + Zone)
2. Press key corresponding to Zone Light (if Zone 1 flashes press 1 key)
3. Zone Lights now will show exact Trouble

1 = System Trouble (Press 1 again for exact Trouble)
1 = System AC Failure
2 = System Battery Failure
3 = Aux Power Overload
4 = Bell Current Overload
5 = Siren Trouble or Absent
6 = ROM Check Error (Problem with Panel)
2 = Communicator (Press 2 again for exact Trouble)
1 = TLM Trouble/No Phones
2 = System Fail To Communicate
3 = Download Fail to Communicate
3 = Module Trouble (Press 3 again for exact Trouble)
1 = Module Tamper
2 = ROM Check error
3 = Phone Line Trouble (Set for Service for these troubles)
4 = Module Fail to Communicate
5 = Printer Trouble
6 = Module AC Failure
7 = Module Battery Failure
8 = Supply Output Overload
4 = Bus Trouble (Press 4 again for exact Trouble)
1 = Missing Keypad
2 = Missing Module
6 = General Failure (Set for Service for these troubles)
7 = Bus Overload
8 = Bus Communication Error
5 = Zone Tamper (Press 7 again to show exact Zone)
6 = Zone Low Battery (Press 7 again to show exact Zone)
7 = Wireless Zone Fault (Press 7 again to show exact Zone)
8 = Loss of Clock (See Set Time/Date below)
Set Time/Date 1. Press 8 button (TRBL Flashes, PRG turns ON)
2. Enter Hours and Minutes Military Time (Keypad beeps)
(1:30PM would be 1330)
3. Enter Year/Month/Day (July 02 2000 would be 20000702)
4. Press CLEAR button to exit