Napco MA 850 / 854 Basics
System is Chip Programmable only, it cannot be downloaded or programmed from keypad | |
Zones |
850 – 8 zones 900 – 9 zones |
Battery | 12 volt rechargeable Gel-Cell inside main panel |
AC Transformer | 16.5 volts, screwed into outlet somewhere in house |
Wireless | No |
Downloadable | No |
Panic Button | Police Panic only, * & # |
Zone Status | STATUS light blinks if zone open, press 3 key for 3 seconds to display |
Arm | 4-digit User Code (MUST have steady STATUS light) |
Disarm | 4-digit User Code (If wrong code entered wait 5 seconds, try again) |
Silence Alarm | 4-digit User Code |
Clear Alarm | Press 9 for 3 seconds |
Flashing P | Customer tried arming without steady STATUS light, disarm and try again |
Bypass Zone | Press [S] + zone (1, 2, 3 etc), BYPASS light turns on |
Group Bypass | (if enabled) Many interior zones can be bypassed by pressing [S] twice |
Alarm History | Hold [S] key for 3 seconds to view last alarm |
Smoke Reset | Press 9 for 3 seconds |
Door Chimes | Press 5 for 3 seconds |
Instant Doors | Press 4 for 3 seconds before or after arming, STATUS light flashes rapidly |
Phone Test |
1. Press 6 for 3 seconds to start, keypad will begin beeping 2. If test is okay beeping will stop, failed test sounds a steady tone 3. Press 9 for 3 seconds to stop steady tone in case of failure |