Napco MA 850 / 854 Basics

System is Chip Programmable only, it cannot be downloaded or programmed from keypad
Zones 850 – 8 zones
900 – 9 zones
Battery 12 volt rechargeable Gel-Cell inside main panel
AC Transformer 16.5 volts, screwed into outlet somewhere in house
Wireless No
Downloadable No
Panic Button Police Panic only, * & #
Zone Status STATUS light blinks if zone open, press 3 key for 3 seconds to display
Arm 4-digit User Code (MUST have steady STATUS light)
Disarm 4-digit User Code (If wrong code entered wait 5 seconds, try again)
Silence Alarm 4-digit User Code
Clear Alarm Press 9 for 3 seconds
Flashing P Customer tried arming without steady STATUS light, disarm and try again
Bypass Zone Press [S] + zone (1, 2, 3 etc), BYPASS light turns on
Group Bypass (if enabled) Many interior zones can be bypassed by pressing [S] twice
Alarm History Hold [S] key for 3 seconds to view last alarm
Smoke Reset Press 9 for 3 seconds
Door Chimes Press 5 for 3 seconds
Instant Doors Press 4 for 3 seconds before or after arming, STATUS light flashes rapidly
Phone Test 1. Press 6 for 3 seconds to start, keypad will begin beeping
2. If test is okay beeping will stop, failed test sounds a steady tone
3. Press 9 for 3 seconds to stop steady tone in case of failure