Napco 825 Basics

Chip Programmable only, cannot be downloaded or programmed from keypad
Zones 725 has 4 zones, 825 has 6
Battery 12 volt rechargeable inside main control panel
Wireless No
Downloadable No
Panic Button Police Panic, press * & #
Arm Enter 4-digit code (MUST have steady STATUS light)
Disarm Enter 4-digit code
Silence Alarm 4-digit code, hold 9 for 3 seconds to clear display
Zone Status STATUS light blinks if zone open, 1 time for zone 1, 2 for zone 2 etc
Bypass Zone [S] + Zone (1, 2, 3 etc), press again to remove
Group Bypass (if enabled) Many interior zones bypass by pressing [S] twice
Alarm History Hold 2 for 3 seconds to view last alarm
Reset Hold 9 for 3 seconds
Smoke Reset Press button on outside of Main Panel
Door Chimes Hold 5 for 3 seconds
Instant Doors Hold 4 for 3 seconds before or after arming, STATUS light flashs rapidly
Phone Test Hold 6 for 3 seconds, failed test causes keypad to sound steady tone