Napco MA 800 / 800s Basics
Chip Programmable only, cannot be downloaded or programmed from keypad | |
Zones | 4 Hardwire zones, 1 24 hr Panic Zone |
Battery | 12 volt rechargeable inside main control panel |
AC Transformer | 16.5 volts, screwed into outlet somewhere in house |
Wireless | No |
Downloadable | No |
Panic Button | Police Panic only, press * & # |
Zone Status | STATUS light blinks if zone open, 1 blink = Zone 1, 2 blinks = Zone 2 etc |
Arm |
4-digit User Code (If arming with open zone keypad beeps & flashes, enter code again to clear) |
Instant Doors | There is no instant door function |
Disarm | 4-digit User Code |
Silence Alarm | 4-digit User Code (ARMED/MEMORY flashes Zone in alarm (4 flashes = Zone 4) |
Clear Alarm | Arm then disarm |
Bypass Zone | Press S key + Zone (1, 2, 3 etc) (SHUNT light turns ON) |
Alarm History | There is no alarm history |
Smoke Reset | Press button on outside of Main Control Panel |
Door Chimes | There is no door chime |