MA 2600 Program

Enter Program 1. Raise the keypad cover
2. Enter the dealer security code (Found on sticker in panel) and press ON/OFF
3. Display should read PROGRAM 2 and ADDR = 000 DATA =
(All programming must be done from Keypad addressed as #1)

OR

1. Press FUNCTION until display reads ACTIVATE PROGRAM
2. Press YES (INTERIOR), enter Installer Program Code (default 456789)
3. Display should read PROGRAM 2 and ADDR = 000 DATA =
(All programming must be done from Keypad addressed as #1)

Move to Location 1. Press 4 until you get to the address field
2. Enter 3-digit Location and hit 0
3. Display will show data in Location

1 moves left 2 scrolls right in a location
4 scrolls up 7 scrolls down through digits
0 reads data in a location
5 blanks out a location
ON/OFF stores data in location
INTERIOR moves to previous location (Hold to scroll fast)
INSTANT moves to next program location (Hold to scroll fast)
Exit Program Press RESET, may need to enter Installer Code
Do NOT power panel down before exiting programming, failure to do so will erase all your changes

User Codes

User Code 1 User Code 2 User Code 3
I _7_
003
I _8_
004
I _9_
005
I _ _
006
I _ _
007
I _ _
008
I     I _ _
009
I _ _
010
I _ _
011
I _ _
012
I _ _
013
I _ _
014
I     I _ _
015
I _ _
016
I _ _
017
I _ _
018
I _ _
019
I _ _
020

I
User Code 4 User Code 5 User Code 6
I _7_
021
I _8_
022
I _9_
023
I _ _
024
I _ _
025
I _ _
026
I     I _ _
027
I _ _
028
I _ _
029
I _ _
030
I _ _
031
I _ _
032
I     I _ _
033
I _ _
034
I _ _
035
I _ _
036
I _ _
037
I _ _
038

I
User Code 7 User Code 8 User Code 9
I _7_
039
I _8_
040
I _9_
041
I _ _
042
I _ _
043
I _ _
044
I     I _ _
045
I _ _
046
I _ _
047
I _ _
048
I _ _
049
I _ _
050
I     I _ _
051
I _ _
052
I _ _
053
I _ _
054
I _ _
055
I _ _
056

I
User Code 10 User Code 11 User Code 12
I _7_
057
I _8_
058
I _9_
059
I _ _
060
I _ _
061
I _ _
062
I     I _ _
>
063
I _ _
064
I _ _
065
I _ _
066
I _ _
067
I _ _
068
I     I _ _
069
I _ _
070
I _ _
071
I _ _
072
I _ _
073
I _ _
074

I
User Code 13 User Code 14 User Code 15
I _7_
075
I _8_
076
I _9_
077
I _ _
078
I _ _
079
I _ _
080
I     I _ _
081
I _ _
082
I _ _
083
I _ _
084
I _ _
085
I _ _
086
I     I _ _
087
I _ _
088
I _ _
089
I _ _
090
I _ _
091
I _ _
092

I
User Code 16 Service Code Access Code
I _7_
093
I _8_
094
I _9_
095
I _ _
096
I _ _
097
I _ _
098
I     I _ _
099
I _ _
100
I _ _
101
I _ _
102
I _ _
103
I _ _
104
I     I _ _
111
I _ _
112
I _ _
113
I _ _
114
I _ _
115
I _ _
116

I
Installer/Dealer Code I _ _
119
I _ _
120
I _ _
121
I _ _
122
I _ _
123
I _ _
124
I (Installer Code on sticker in panel)
Hostage/Duress Code I _9_
117
I _9_
118
I
User Program Code I _1_
105
I _2_
106
I _3_
107
I _4_
108
I _3_
109
I _4_
110
I (This is used to change User codes)

Communicator Options

Report Format Phone 1 I_1_I
208
I_ _I_5_I
209
Location 208 Location 209 1st Digit Location 209 2nd Digit
Blank = Ademco/Silent Knight Slow 1 = Sumcheck 1 = 2300Hz Handshake
1 = Sescoa, Vertex, DCI, Franklin 2 = Not Used 2 = 2300Hz Kissoff
2 = Radionics Fast 3 = Not Used 4 = 4/2
3 = Silent Knight Fast 4 = Not Used 8 = Single Digit Only
4 = Radionics, DCI, Franklin Slow
5 = Universal Hi Speed
8 = Radionics BFSK
Receiver 1 Phone Number
I _E_
128
I _1_
129
I _8_
130
I _?_
131
I _?_
132
I _?_
133
I _?_
134
I _?_
135
I _?_
136
I _?_
137
I _?_
138
I _?_
139
I _ _
140
I _ _
141
I _ _
142
I _ _
143
I _ _
>
144
I _ _
145
I _ _
146
I _ _
147

I
Report Format Phone 2 I_1_I
210
I_ _I_5_I
211
Receiver 2 Phone Number
I _E_
148
I _1_
149
I _8_
150
I _?_
151
I _?_
152
I _?_
153
I _?_
154
I _?_
155
I _?_
156
I _?_
157
I _?_
158
I _?_
159
I _ _
160
I _ _
161
I _ _
162
I _ _
163
I _ _
164
I _ _
165
I _ _
166
I _ _
167

I
Report Format Phone 3 I_ _I
212
I_ _I_ _I
213
Receiver 3 Phone Number
I _E_
168
I _ _
169
I _ _
170
I _ _
171
I _ _
172
I _ _
173
I _ _
174
I _ _
175
I _ _
176
I _ _
177
I _ _
178
I _ _
179
I _ _
180
I _ _
181
I _ _
182
I _ _
183
I _ _
184
I _ _
185
I _ _
186
I _ _
187

I
Receiver 1 Account Number   (Program last 4 digits of Account Number in all Banks)
Open/Close Area Bank 0 Bank 1 Bank 2 Bank 3
I _ _
248
I _ _
249
I _ _
250
I _ _
251
I     I _ _
252
I _ _
253
I _ _
254
I _ _
255
I     I _ _
256
I _ _
257
I _ _
258
I _ _
259
I     I _ _
260
I _ _
261
I _ _
262
I _ _
263
I     I _ _
264
I _ _
265
I _ _
266
I _ _
267
I
Bank 4 Bank 5 Bank 6 Bank 7 Bank 8
I _ _
268
I _ _
269
I _ _
270
I _ _
271
I     I _ _
272
I _ _
273
I _ _
274
I _ _
275
I     I _ _
276
I _ _
277
I _ _
278
I _ _
279
I     I _ _
280
I _ _
281
I _ _
282
I _ _
283
I     I _ _
284
I _ _
285
I _ _
286
I _ _
287

I
Receiver 2 Account Number (Usually leave this blank)
Open/Close Area Bank 0 Bank 1 Bank 2 Bank 3
I _ _
288
I _ _
289
I _ _
290
I _ _
291
I     I _ _
292
I _ _
293
I _ _
294
I _ _
295
I     I _ _
296
I _ _
297
I _ _
298
I _ _
299
I     I _ _
300
I _ _
301
I _ _
302
I _ _
303
I     I _ _
304
I _ _
305
I _ _
306
I _ _
307
I
Bank 4 Bank 5 Bank 6 Bank 7 Bank 8
I _ _
308
I _ _
309
I _ _
310
I _ _
311
I     I _ _
312
I _ _
313
I _ _
314
I _ _
315
I     I _ _
316
I _ _
317
I _ _
318
I _ _
319
I     I _ _
320
I _ _
321
I _ _
322
I _ _
323
I     I _ _
324
I _ _
325
I _ _
326
I _ _
327

I
Receiver 3 Account Number (Usually leave this blank)
Open/Close Area Bank 0 Bank 1 Bank 2 Bank 3
I _ _
328
I _ _
329
I _ _
330
I _ _
331
I     I _ _
332
I _ _
333
I _ _
334
I _ _
335
I     I _ _
336
I _ _
337
I _ _
338
I _ _
339
I     I _ _
340
I _ _
341
I _ _
342
I _ _
343
I     I _ _
344
I _ _
345
I _ _
346
I _ _
347
I
Bank 4 Bank 5 Bank 6 Bank 7 Bank 8
I _ _
348
I _ _
349
I _ _
350
I _ _
351
I     I _ _
352
I _ _
353
I _ _
354
I _ _
355
I     I _ _
356
I _ _
357
I _ _
358
I _ _
359
I     I _ _
360
I _ _
361
I _ _
362
I _ _
363
I     I _ _
364
I _ _
365
I _ _
366
I _ _
367
I


Download Options

Callback (Download) Telephone Number
I _ _
188
I _ _
189
I _ _
190
I _ _
191
I _ _
192
I _ _
193
I _ _
194
I _ _
195
I _ _
196
I _ _
197
I _ _
198
I _ _
199
I _ _
200
I _ _
201
I _ _
202
I _ _
203
I _ _
204
I _ _
205
I _ _
206
I _ _
207

I
Number of Rings before Answer I_9_I
993

Report Codes

( ) = Default
Fire Zone 1 I _1_
368
(1)
I _6_
369
(1)
I     Fire Zone 2 I _1_
370
(1)
I _2_
371
(2)
I     Fire Trouble I _1_
372
(1)
I _F_
373
(F)

I
Ambush I _2_
374
(2)
I _2_
375
(1)
I Police Panic I _2_
376
(2)
I _1_
377
(2)
I Low Battery I _1_
378
(1)
I _8_
379
(8)

I
AC Failure I _1_
466
(1)
I _9_
467
(9)

Zone 1 I _3_
385
(3)
I _1_
386
(1)
I Zone 2 I _3_
387
(3)
I _2_
388
(2)
I Zone 3 I _3_
389
(3)
I _3_
390
(3)

I
Zone 4 I _3_
391
(3)
I _4_
392
(4)
I Zone 5 I _3_
393
(3)
I _5_
394
(5)
I Zone 6 I _3_
395
(3)
I _6_
396
(6)

I
Zone 7 I _3_
397
(3)
I _7_
398
(7)
I Zone 8 I _3_
399
(3)
I _8_
400
(8)
I Zone 9 I _4_
401
(4)
I _1_
402
(1)

I
Zone 10 I _4_
403
(4)
I _2_
404
(2)
I Zone 11 I _4_
405
(4)
I _3_
406
(3)
I Zone 12 I _4_
407
(4)
I _4_
408
(4)

I
Zone 13 I _4_
409
(4)
I _5_
410
(5)
I Zone 14 I _4_
411
(4)
I _6_
412
(6)
I Zone 15 I _4_
413
(4)
I _7_
414
(7)

I
Zone 16 I _4_
415
(4)
I _8_
416
(8)
I Zones 17 – 24 I _5_
426
(5)
I Zones 25 – 32 I _6_
429
(6)

I
Zones 33 – 40 I _7_
432
(7)
I Zones 41 – 48 I _8_
435
(8)
I Zones 49 – 56 I _9_
438
(9)

I
Zones 57 – 64 I _0_
441
(0)

I
Restorals     ( ) = Default

Bank 0 I _ _
418
(E)
I Zones 1 – 8 I _ _
421
(E)
I Zones 9 – 16 I _ _
424
(E)

I
Zones 17 – 24 I _ _
427
(E)
I Zones 25 – 32 I _ _
430
(E)
I Zones 33 – 40 I _ _
433
(E)

I
Zones 41 – 48 I _ _
436
(E)
I Zones 49 – 56 I _ _
439
(E)
I Zones 57 – 64 I _ _
442
(E)

I
Troubles     ( ) = Default

Zones 1 – 8 I _ _
422
(F)
I Zones 9 – 16 I _ _
425
(F)
I Zones 17 – 24 I _ _
428
(F)

I
Zones 25 – 32 I _ _
431
(F)
I Zones 33 – 40 I _ _
434
(F)
I Zones 41 – 48 I _ _
437
(F)

I
Zones 49 – 56 I _ _
440
(F)
I Zones 57 – 64 I _ _
443
(F)
I

Zone Options Add section, place total in box (Example: 1 + 4 + 8 = 13 or “D”)   I_ _I = Blank with 5 key

Loop Response 50ms I_ _I_ _I
576
I_ _I_ _I
624
Loop Response 50ms I_ _I_ _I
625
I_ _I_ _I
577
Priority Zone I_F_I_F_I
578
I_F_I_F_I
626
I_ _I_ _I
530
Priority with Bypass I_ _I_ _I
>
579
I_ _I_ _I
627
I_ _I_ _I
531
Auto Bypass I_ _I_ _I
580
I_ _I_ _I
628
Selective Bypass I_F_I_F_I
581
I_F_I_F_I
629
Group (Interior) Bypass I_ _I_ _I
582
I_ _I_ _I
>
630
24 Hour Protection I_ _I_ _I
583
I_ _I_ _I
631
Sweep Siren I_F_I_F_I
584
I_F_I_F_I
632
I_ _I_ _I
536
Pulse-Sweep Siren I_ _I_ _I
585
I_ _I_ _I
633
I_1_I_ _I
537
Steady Siren I_ _I_ _I
586
I_ _I_ _I
634
I_ _I_3_I
538
Relay Output 1 I_ _I_ _I
587
I_ _I_ _I
635
I_ _I_ _I
539
Relay Output 2 I_ _I_ _I
588
I_ _I_ _I
636
I_ _I_ _I
540
Exit/Entry 1 I_?_I_?_I
589
I_?_I_?_I

Entry/Exit 2 I_ _I_ _I
590
I_ _I_ _I

E/E Follower (Motions) I_?_I_?_I
591
I_?_I_?_I
639
Auto Reset I_F_I_F_I
592
I_F_I_F_I
640
Swinger Shutdown I_F_I_F_I
>
593
I_F_I_F_I
641
Chime I_?_I_?_I
594
I_?_I_?_I
642
Abort Delay I_ _I_ _I
595
I_ _I_ _I
643
I_ _I_ _I
547
Power-Up Delay I_ _I_ _I
596
I_ _I_ _I
644
Day Zone Open I_ _I_ _I
597
I_ _I_ _I
645
Day Zone Short I_ _I_ _I
598
I_ _I_ _I
646
Alarm on Day Zone I_ _I_ _I
599
I_ _I_ _I
647
Report Alarm Telco 1 I_F_I_F_I
600
I_F_I_F_I
648
I_ _I_ _I
552
Report Restore Telco 1 I_ _I_ _I
601
I_ _I_ _I
649
I_7_I_F_I
553
Report Trouble Telco 1 I_ _I_ _I
602
I_ _I_ _I
650
Report Trbl Rest Telco 1 I_ _I_ _I
603
I_ _I_ _I
651
Report Alarm Telco 3 I_ _I_ _I
608
I_ _I_ _I
656
I_ _I_ _I
560
Report Restore Telco 3 I_ _I_ _I
609
I_ _I_ _I
657
I_ _I_ _I
561
Report Trouble Telco 3 I_ _I_ _I
610
I_ _I_ _I
658
Report Trbl Rest Telco 3 I_ _I_ _I
611
I_ _I_ _I
659
No EOL Resistor I_ _I_ _I
612
I_ _I_ _I
660
PIR Supervision I_ _I_ _I
613
I_ _I_ _I
661
Trouble on Open I_ _I_ _I
614
I_ _I_ _I
662
Trouble on Short I_ _I_ _I
615
I_ _I_ _I
663
Trouble on Night Open I_ _I_ _I
616
I_ _I_ _I
664

Open/Closing

Opening Telco 1 I_ _I_ _I
564
I_ _I_ _I
565
Closing Telco 1 I_ _I_ _I
566
I_ _I_ _I
567
Opening Telco 3 I_ _I_ _I
572
I_ _I_ _I
573
Closing Telco 3 I_ _I_ _I
574
I_ _I_ _I
575
Opening Code   I_ _I  
382
(B)
Closing Code   I_ _I  
383
(C)
Force Arm Code   I_ _I  
384
(F)

CS Area & System Reporting Options

1 = Reset Test Time on Report
2 = Activate Zone 14 on EZM Tamper
4 = Reserved
8 = Reserved
I_ _I_4_I
455
( ) (4)
1 = Backup Reporting Telco 1, 2
2 = Touchtone Dialing only
4 = Touchtone with Rotary Backup
8 = Report Test Timer on Zone 16

1 = Disable Funct 8 Download
2 = Disable Callback Download
4 = Disable Carrier Download
8 = Disable Auto-Reset on Day Zone
I_ _I_ _I
969
( ) (4)
1 = Interior Normally Bypassed
2 = Reserved
4 = Reset Day Zone w/Arm/Disarm Only
8 = Watch On with Function 2

1 = Access Control on Relay 2
2 = Easy Arm with ON/OFF Button
4 = Report Service Code as User 15
8 = Start Exit Delay after Ringback
I_ _I_2_I
970
( ) (2)
1 = Auto Bell Test on Arming
2 = Auto Reset after Sweep Siren Timeout
4 = Power Up in Last State
8 = Disable Smoke Reset on Relay 1

1 = Enable Red Buttons as Fire
2 = Enable Green Buttons as Zone 15
4 = Enable Bule Buttons as Panics
8 = Enable Telco Test on KP Test
I_D_I_ _I
971
(D) ( )
1 = Opening Report only after Alarm Rep.
2 = Closing only on Force Arm
4 = Incl Sel/Grp Bypass in Force Arm
8 = Status Report
(Program 26 in locations 413 – 414 to enable medical, do not use if zn15 is used)

System Times

Exit Delay
(Seconds)
I_3_I_C_I
000

Entry Delay 1
(Seconds)
I_1_I_E_I
001

Entry Delay 2
(Seconds)
I_1_I_E_I
002

Relay Output 1 Time
(Minutes)
I_ _I_ _I
960

Relay Output 2 Time
(Minutes)
I_ _I_ _I
961

Relay Output 2 Access Control Time
(Seconds)
I_ _I_ _I
962

Sweep Siren Time
(Minutes)
I_ _I_6_I
963

Pulse Sweep Siren Time
(Minutes)
I_ _I_6_I
964

Steady Siren Time
(Minutes)
I_ _I_6_I
965

Abort Delay Time
(Seconds)
I_ _I_ _I
966

Chime Time
(Seconds)
I_ _I_1_I
967

AC Fail Report Delay
(Minutes)
I_4_I_ _I
968

PIR Supervision
(24 Disarmed Hours)
I_ _I_ _I
992

Test Timer Power-Up Offset (Hours) I_ _I_ _I
456

Test Timer Report Interval (Days) I_ _I_ _I
457


System Options

Number of Keypads on System I_?_I
995

Number of EZM Groups I_?_I
996

(4 EZM Zones = 1 Group)
To use below options go to Location then press ON/OFF
Clear Dealer Program 997
Load Default Program 998
Load Prom 999