Napco 1016LKDL Basics

Zones 14 + 1 Fire Zone
Wireless No
Resistors 2.2K
Fuses 3 Amp = Siren, 1 Amp = Aux
Battery 12 volt rechargeable Gel-Cell inside main panel
Downloadable Yes but very difficult
Panic Buttons Police Panic, press * & #
Arm Enter 4-digit code (MUST have steady STATUS light)
Disarm Enter 4-digit code
Instant Doors Hold 4 key for 3 seconds before or after arming, STATUS light will flash rapidly
Zone Status STATUS light blinks if zone open, press 3 for 3 seconds to view
Flashing P Attempted arming with open zone
Disarm and try arming again
Bypass Press [S] + Zone (01, 02, 03 etc) (BYPASS light will turn on) (Use the “S” key for zero)
Reset Press 9 for 3 seconds to clear mistakes, alarm displays and reset Smoke Detectors
Door Chimes Hold 5 for 3 seconds
Phone Test Hold 6 for 3 seconds, failed test will cause keypad to sound steady tone