Napco MA 1016E Program

Click HERE for Programming Keys
Format Program a 1 in location 236 and a 5 in 238, leave 239 blank
Enter Program (Default is 4 5 6 7 8 9)
1. Hold 8 key for 3 seconds, keypad will beep
2. Enter 4 5 6 7 8 9, display should show dash
Exit Program 1. Hold 8 for 3 seconds, keypad will start flashing
2. Enter 4 5 6 7 8 9, keypad should return to normal
Enable Panics Open Keypad cover, cut Jumper “E” (bottom left jumper, clearly marked)
Move to Location 1. Press [B/A] (Display shows 3 dashes)
2. Enter 3-digit Location (as each digit is entered 1 dash disappears)
3. Display will show data in Location
LED Keypads 4 Scrolls Up, 7 Scrolls Down, 2 Moves to Next, 1 Moves to Previous, 5 Clears Location
LCD Keypads 5 Scrolls Up, 9 Scrolls Down, 2 Moves to Next, 1 Moves to Previous, 6 Clears Location

User Codes                                        

User Code 1 User Code 2 User Code 3
I _1_
006
I _2_
007
I _3_
008
I _4_
009
I _ _
010
I _ _
011
I       I _ _
012
I _ _
013
I _ _
014
I _ _
015
I _ _
016
I _ _
017
I       I _ _
018
I _ _
019
I _ _
020
I _ _
021
I _ _
022
I _ _
023

I
User Code 4 User Code 5 User Code 6
I _1_
024
I _2_
025
I _3_
026
I _4_
027
I _ _
028
I _ _
029
I I _ _
030
I _ _
031
I _ _
032
I _ _
033
I _ _
034
I _ _
035
I I _ _
036
I _ _
037
I _ _
038
I _ _
039
I _ _
040
I _ _
041

I
User Code 7 User Code 8 User Code 9
I _1_
042
I _2_
043
I _3_
044
I _4_
045
I _ _
046
I _ _
047
I I _ _
048
I _ _
049
I _ _
050
I _ _
051
I _ _
052
I _ _
053
I I _ _
054
I _ _
055
I _ _
056
I _ _
057
I _ _
058
I _ _
059

I
User Code 10 User Code 11 User Code 12
I _1_
060
I _2_
061
I _3_
062
I _4_
063
I _ _
064
I _ _
065
I I _ _
066
I _ _
067
I _ _
068
I _ _
069
I _ _
070
I _ _
071
I I _ _
072
I _ _
073
I _ _
074
I _ _
075
I _ _
076
I _ _
077

I
User Code 13 User Code 14 User Code 15
I _1_
078
I _2_
079
I _3_
080
I _4_
081
I _ _
082
I _ _
083
I I _ _
084
I _ _
085
I _ _
086
I _ _
087
I _ _
088
I _ _
089
I I _ _
090
I _ _
091
I _ _
092
I _ _
093
I _ _
094
I _ _
095

I
Manager Code Access Code
I _ _
096
I _ _
097
I _ _
098
I _ _
099
I _ _
100
I _ _
101
I I _ _
108
I _ _
109
I _ _
110
I _ _
111
I _ _
112
I _ _
113

I
Hostage/Duress Code User Program Code
(This is used to change User codes)
Installer/Dealer Code
(Leave Default)
I _9_
114
I _9_
115
I I _1_
120
I _2_
121
I _3_
122
I _4_
123
I _5_
124
I _6_
125
I I _4_
126
I _5_
127
I _6_
128
I _7_
129
I _8_
130
I _9_
131
I

Arming/Opening Closing Options                            

Area 1 Arm/Disarm
(User Code Partitioning)
I_F_I
828
(F)
I_F_I
829
(F)
I_F_I
830
(F)
I_7_I
831
(7)
Area 2 Arm/Disarm
(User Code Partitioning)
I_ _I
832
( )
I_ _I
833
( )
I_ _I
834
( )
I_ _I
835
( )
Closing Reports Telco 1 I_ _I
584
( )
I_ _I
585
( )
I_ _I
586
( )
I_ _I
587
( )
Opening Reports Telco 1 I_ _I
588
( )
I_ _I
589
( )
I_ _I
590
( )
I_ _I
591
( )
Closing Reports Telco 3 I_ _I
600
( )
I_ _I
601
( )
I_ _I
602
( )
I_ _I
603
( )
Opening Reports Telco 3 I_ _I
604
( )
I_ _I
605
( )
I_ _I
606
( )
I_ _I
607
( )

Communicator Options                            

Download Phone Number 1 (Leave Blank)

I _ _
316
I _ _
317
I _ _
318
I _ _
319
I _ _
320
I _ _
321
I _ _
322
I _ _
323
I _ _
324
I _ _
325
I _ _
326
I _ _
327
I _ _
328
I _ _
329
I _ _
330
I _ _
331
I _ _
332
I _ _
333
I _ _
334
I _ _
335
I
Download Phone Number 2 (Leave Blank)

I _ _
900
I _ _
901
I _ _
902
I _ _
903
I _ _
904
I _ _
905
I _ _
906
I _ _
907
I _ _
908
I _ _
909
I _ _
910
I _ _
911
I _ _
912
I _ _
913
I _ _
914
I _ _
915
I _ _
916
I _ _
917
I _ _
918
I _ _
919
I
Callback Select I _ _
508
I
Rings Before Answer I _9_
826
I
Auto Download ID I _ _
511
I _ _
510
I
Report Format Phone 1   I _1_
336
I _5_
338
I _ _
339
I                                                                                                                                                
First Digit Second Digit Third Digit
Blank = Ademco/Silent Knight Slow 1 = 2300Hz Handshake 1 = Sumcheck
1 = Sescoa, Vertex, DCI, Franklin 2 = 2300Hz Kissoff 2 = Reserved
2 = Radionics Fast 4 = 4/2 4 = Reserved
3 = Silent Knight Fast 8 = Single Digit Only 8 = Reserved
4 = Radionics, DCI, Franklin Slow (Add together)
5 = Universal Hi Speed

Receiver 1 Phone Number

I _ _
256
I _ _
257
I _ _
258
I _ _
259
I _E_
260
I _1_
261
I _8_
262
I _?_
263
I _?_
264
I _?_
265
I _?_
266
I _?_
267
I _?_
268
I _?_
269
I _?_
270
I _?_
271
I _ _
272
I _ _
273
I _ _
274
I _ _
275
I

Report Format Phone 2 I _1_
340
I _5_
342
I _ _
343
I
Receiver 2 Phone Number

I _ _
276
I _ _
277
I _ _
278
I _ _
279
I _E_
280
I _1_
281
I _8_
282
I _?_
283
I _?_
284
I _?_
285
I _?_
286
I _?_
287
I _?_
288
I _?_
289
I _?_
290
I _?_
291
I _ _
292
I _ _
293
I _ _
294
I _ _
295
I

Report Format Phone 3 I _ _
344
I _ _
346
I _ _
347
I
Receiver 3 Phone Number

I _ _
296
I _ _
297
I _ _
298
I _ _
299
I _E_
300
I _ _
301
I _ _
302
I _ _
303
I _ _
304
I _ _
305
I _ _
306
I _ _
307
I _ _
308
I _ _
309
I _ _
310
I _ _
311
I _ _
312
I _ _
313
I _ _
314
I _ _
315
I
Receiver 1 Account Number (Program last 4 digits of Account Number in Bank 0, Bank 1 and Bank 2)

Open/Close Area 1 Open/Close Area 2 Bank 0 Bank 1 Bank 2
I _ _
354
I _ _
355
I _ _
356
I _ _
357
I     I _ _
358
I _ _
359
I _ _
360
I _ _
361
I     I _ _
362
I _ _
363
I _ _
364
I _ _
365
I     I _ _
366
I _ _
367
I _ _
368
I _ _
369
I     I _ _
370
I _ _
371
I _ _
372
I _ _
373
I

Receiver 2 Account Number (Usually leave this blank)

Open/Close Area 1 Open/Close Area 2 Bank 0 Bank 1 Bank 2
I _ _
>
374
I _ _
375
I _ _
376
I _ _
377
I     I _ _
378
I _ _
379
I _ _
380
I _ _
381
I     I _ _
382
I _ _
383
I _ _
384
I _ _
385
I     I _ _
386
I _ _
387
I _ _
388
I _ _
389
I     I _ _
390
I _ _
391
I _ _
392
I _ _
393
I

Receiver 3 Account Number (Usually leave this blank)

Open/Close Area 1 Open/Close Area 2 Bank 0 Bank 1 Bank 2
I _ _
394
I _ _
395
I _ _
396
I _ _
397
I     I _ _
398
I _ _
399
I _ _
400
I _ _
401
I     I _ _
402
I _ _
403
I _ _
404
I _ _
405
I     I _ _
406
I _ _
407
I _ _
408
I _ _
409
I     I _ _
410
I _ _
411
I _ _
412
I _ _
413
I

Report Codes                            

Default Values in ( )
Fire Zone Alarm   Fire Zone Trouble   No Close Test Timer
I _1_
426
(1)
I _6_
427
(1)
I
I _7_
428
(1)
I _6_
429
(F)
I
I _ _
430
( )
I _ _
431
( )
I
I _ _
432
( )
I _ _
433
( )
I
Low Battery AC Failure   Police Panic     Ambush/Duress  
I _7_
434
(1)
I _8_
435
(8)
I
I _7_
436
(1)
I _9_
437
(9)
I
I _2_
466
(2)
I _1_
467
(1)
I
I _2_
468
(2)
I _2_
469
(2)
I
Zone 1 Zone 2 Zone 3 Zone 4
I _3_
438
(3)
I _1_
439
(1)
I
I _3_
440
(3)
I _2_
441
(2)
I
I _3_
442
(3)
I _3_
443
(3)
I
I _3_
444
(3)
I _4_
445
(4)
I
Zone 5 Zone 6 Zone 7 Zone 8
I _3_
446
(3)
I _5_
447
(5)
I
I _3_
448
(3)
I _6_
449
(6)
I
I _3_
450
(3)
I _7_
451
(7)
I
I _3_
452
(3)
I _8_
453
(8)
I
Zone 9 Zone 10 Zone 11 Zone 12
I _3_
454
(3)
I _9_
455
(9)
I
I _4_
456
(4)
I _1_
457
(1)
I
I _4_
458
(4)
I _2_
459
(2)
I
I _4_
460
(4)
I _3_
461
(3)
I
Zone 13 Zone 14/Aux Panic
I _4_
462
(4)
I _4_
463
(4)
I
I _4_
464
(4)
I _5_
465
(5)
I
Restore Code
Bank 0
I_ _I
470
(E)
Restore Code
Bank 1
I_ _I
474
(E)
Restore Code
Bank 2
I_ _I
478
(E)
Trouble/Status
Bank 1
I_ _I
476
(F)
Trouble/Status
Bank 2
I_ _I
480
(F)
Area 1 Opening     I_ _I    
414
(B)
Area 1 Closing     I_ _I    
416
(C)
Area 1 ForceArm     I_ _I
418
(F)
Area 2 Opening I_ _I
420
(B)
Area 2 Closing I_ _I
422
(C)
Area 2 ForceArm I_ _I
424
(F)

Zone Options                            

Add each section, place total in box (Example: 1 + 4 + 8 = 13 or “D”)   I_ _I = Blank with 5 key
Loop Response 50ms I_ _I
608
I_ _I
609
I_ _I
704
I_ _I
705
Loop Response 10ms I_ _I
610
I_ _I
611
I_ _I
706
I_ _I
707
Priority Zone I_F_I
612
I_F_I
613
I_F_I
708
I_3_I
709
Priority with Bypass I_ _I
614
I_ _I
615
I_ _I
710
I_ _I
711
Auto Bypass I_ _I
616
I_ _I
617
I_ _I
712
I_ _I
713
Selective Bypass I_F_I
618
I_F_I
619
I_F_I
714
I_3_I
715
Group Bypass I_?_I
620
I_?_I
621
I_?_I
716
I_?_I
717
24 Hour Protection I_ _I
622
I_ _I
623
I_ _I
718
I_4_I
719
Sweep Siren I_F_I
624
I_F_I
625
I_F_I
720
I_3_I
721
Sweep/Pulse Siren I_ _I
626
I_ _I
627
I_ _I
722
I_4_I
723
Steady Siren I_ _I
628
I_ _I
629
I_ _I
724
I_ _I
725
Relay Output I_ _I
630
I_ _I
631
I_ _I
726
I_ _I

Timed Output I_ _I
632
I_ _I
633
I_ _I
728
I_ _I
729
Entry/Exit 1 I_?_I
634
I_?_I
635
I_?_I
730
I_?_I
731
Entry/Exit 2 I_ _I
636
I_ _I
637
I_ _I
732
I_ _I
733
Entry/Exit Follower (Motions) I_?_I
638
I_?_I
639
I_?_I
734
I_?_I
735
Auto Reset I_F_I
640
I_F_I
641
I_F_I
736
I_3_I
737
Swinger Shutdown I_F_I
642
I_F_I
643
I_F_I
738
I_3_I
739
Chime I_1_I
644
I_ _I
645
I_ _I
740
I_ _I
741
Abort Delay I_ _I
646
I_ _I
647
I_ _I
742
I_ _I
743
Power-Up Delay I_ _I
648
I_ _I
649
I_ _I
744
I_ _I
745
Day Zone Open I_ _I
650
I_ _I
651
I_ _I
746
I_ _I
747
Day Zone Short I_ _I
652
I_ _I
653
I_ _I
748
I_ _I
749
Alarm on Day Zone I_ _I
654
I_ _I
655
I_ _I
750
I_ _I
751
Alarm Telco 1 I_F_I
656
I_F_I
657
I_F_I
752
I_3_I
753
Alarm Restore Telco 1 I_ _I
658
I_ _I
659
I_ _I
754
I_ _I
755
Trouble Telco 1 I_?_I
660
I_?_I
661
I_?_I
756
I_?_I
757
Trouble Restore Telco 1 I_ _I
662
I_ _I
663
I_ _I
758
I_ _I
759
Alarm Telco 3 I_ _I
672
I_ _I
673
I_ _I
768
I_ _I
769
Alarm Restore Telco 3 I_ _I
674
I_ _I
675
I_ _I
770
I_ _I
771
Trouble Telco 3 I_ _I
676
I_ _I
677
I_ _I
772
I_ _I
773
Trouble Restore Telco 3 I_ _I
678
I_ _I
679
I_ _I
774
I_ _I
775
No EOL Resistor I_?_I
680
I_?_I
681
I_?_I
776
I_?_I
777
Sensor Watch I_ _I
682
I_ _I
683
I_ _I
778
I_ _I
779
Trouble on Open I_ _I
684
I_ _I
685
I_ _I
780
I_ _I
781
Trouble on Short I_ _I
686
I_ _I
687
I_ _I
782
I_ _I
783
Area (Partition) 1 I_F_I
688
I_F_I
689
I_F_I
784
I_3_I
785
Area (Partition) 2 I_ _I
690
I_ _I
691
I_ _I
786
I_ _I
787
Trouble on Nite Open I_ _I
692
I_ _I
693
I_ _I
788
I_ _I
789
Fire on Burg Zone I_?_I
694
I_?_I
695
I_?_I
790
I_?_I
791
Burg Lug Output I_ _I
696
I_ _I
697
I_ _I
792
I_ _I
793
Keypad Sounder on Alarm I_F_I
698
I_F_I
699
I_F_I
794
I_3_I
795

System Options                            

Add each section, place total in box (Example: 1 + 4 + 8 = 13 or “D”)   I_ _I = Blank with 5 key
Priority Zone I_ _I
516
I_ _I
517
Priority with Bypass I_ _I
518
I_ _I
519
Sweep Siren I_ _I
528
I_ _I
529
Sweep/Pulse Siren I_ _I
530
I_ _I
531
Steady Siren I_1_I
532
I_ _I
533
Relay Output I_ _I
534
I_ _I
535
Area 1 and 2 options only used
with Relay and Timed Outputs
Timed Output I_ _I
536
I_ _I
537
Abort Delay I_ _I
550
I_ _I
551
Alarm Telco 1 I_3_I
560
I_3_I
561
Alarm Restore Telco 1 I_3_I
562
I_ _I
563
Alarm Telco 3 I_ _I
576
I_ _I
577
Alarm Restore Telco 3 I_ _I
578
I_ _I
579

Misc Options                            

Default Values in ( )
Add each section, place total in box (Example: 1 + 4 + 8 = 13 or “D”)   I_ _I = Blank with 5 key
I_4_I
496
(4)
1 = Backup Report Telco 1, 2
2 = Touchtone Dialing Only
4 = Touchtone with Rotary Backup
8 = Reserved
I_ _I
497
( )
1 = Opening Report only after Alarm
2 = Closing Report only on Force Arm
4 = Includ Sel/Grp Byp in Forced-Arm Status
8 = Status Report (Auto bypass on Closing)
I_ _I
818
( )
1 = Fail to Communicate on Lug E15
2 = Disable Auto-Reset on Day Zone
4 = Include Hold-Down 9 to Reset Day Zn
8 = Watch Mode with Hold-Down [7]
I_8_I
819
( )
1 = Disable Function-6 Download
2 = Disable Callback Download
4 = Disable Answering Machine Download
8 = Enable Aux Panic on F/P/A Keypad
I_2_I
820
(2)
1 = Auto Bell Test on Arming
2 = Auto Reset after Siren Timeout
4 = Fire Alarm Verification
8 = Disable Fire Reset on Relay
I_1_I
821
( )
1 = Enable Keypad Tactical Beep
2 = Arm Only with User 13
4 = User 15 is Service Code
8 = Start Exit Delay After Ringback
I_ _I
822
( )
1 = Split System
2 = Sounder on E4 (Area 1)
4 = Silence Fire Alarm on Either Area
8 = Enable Fire Panic on F/P/A Keypads
I_C_I
823
(C)
1 = Disable Bell Test
2 = Disable Display Shunt While Armed
4 = Enable Keypad Panic
8 = Keypad Telco Test
I_1_I
852
( )
1 = Display Open Zones
2 = Reserved
4 = Display Any Bypass
8 = Chime ON with Group Bypass
I_ _I
853
( )
1 = Audio Verification on Lug E15 (NTO)
2 = Reserved
4 = No Power Failure Indication
8 = Reserved

System Times                            

Exit Delay I _C_
000
I _3_
001
I (60 sec)   Fire Siren
(minutes)
I _6_
808
I _ _
809
I
Entry Delay 1 I _E_
002
I _1_
003
I (30 sec) Lug E16 Output
(minutes)
I _6_
810
I _ _
811
I
Entry Delay 2 I _E_
004
I _1_
005
I (30 sec) Abort Delay
(seconds)
I _ _
812
I _ _
813
I
Voltage Output on Alarm
(minutes)
I _ _
800
I _ _
801
I Chime
(1/4 seconds)
I _4_
814
I _ _
815
I
Relay Output
(minutes)
I _ _
802
I _ _
803
I AC Fail Report Delay
(minutes)
I _ _
816
I _4_
817
I
Lug E15 Access Control I _ _
804
I _ _
805
I Sensor Watch
(Disarmed Hours)
I _ _
824
I _ _
825
I
Burg Siren
(minutes)
I _6_
806
I _ _
807

I
Wireless Zone Map (if using R1000 Wireless Receiver)
Transmitter 1 Zone # I _ _
836
I Transmitter 9 Zone # I _ _
844
I
Transmitter 2 Zone # I _ _
837
I Transmitter 10 Zone # I _ _
845
I
Transmitter 3 Zone # I _ _
838
I Transmitter 11 Zone # I _ _
846
I
Transmitter 4 Zone # I _ _
839
I Transmitter 12 Zone # I _ _
847
I
Transmitter 5 Zone # I _ _
840
I Transmitter 13 Zone # I _ _
848
I
Transmitter 6 Zone # I _ _
841
I Transmitter 14 Zone # I _ _
849
I
Transmitter 7 Zone # I _ _
842
I Transmitter 15 Zone # I _ _
850
I
Transmitter 8 Zone # I _ _
843
I Transmitter 16 Zone #   I _ _
851
I