Napco 1010LKDL Program

Click HERE for Programming Keys
How to Identify Panel says “Magnum 1000 Series” which could be 1000e/10008e, 1008/1010LKDL or 1016
Check the inside wiring diagram for exact model
Enter Program 1. Hold 8 key for 3 seconds, keypad will beep
2. Enter 4 5 6 7 8 9, display should show dash on display
Program Location 1. Press S key display will show 3 dashs
2. Enter 3-digit location (use B/A for any 0)
3. Value currently programmed in location will display
4. Scroll Value UP with 4 key, scroll Value DOWN with 7, blank location with 5
5. When display shows desired Value press 2 to move to next location
(Or S + 3-digit location to move to elsewhere)
Programming with
LCD Keypads
LCD layout is slightly different
1 scrolls left 2 scrolls right 5 scrolls data up 9 scrolls data down
Exit Program 1. Hold 8 key 3 seconds, keypad will flash and beep
2. Enter 4 5 6 7 8 9, display should return to normal
Lockout Bypass 1. Run jumper to pins on enpty chip socket marked X (see wiring diagram)
2. Press 9 for 3 seconds, then 8 for 3 seconds and enter 456789
3. LED display should show — , remove jumper and program normallly
(wire MUST be removed to view or change locations)
Zone Page Click HERE for List of what below programming will report
IF something happens power down then up, you have 30 seconds to get into programming

< Report Options >


To program REPORT OPTIONS in locations 166 to 185 see below Diagram

Add location together and enter sum in location
Example: Enable Reporting for Zones 1 to 6, Keypad Panic, Fire, Duress, Fire Trle, AC Fail and Low Bat
1. Press B/A then 1 6 6 to move to Location 166
2. Add ZONE 1 (1) + ZONE 2 (2) + ZONE 3 (4) + ZONE 4 (8) = 15 or F, enter the F in location 166
3. Press 2 key to move to 167
4. Add Zone 5 (1) + Zone 6 (2) + Keypad Panic (8) = 11 (B), enter the B in location 167
5. Press 2 key to move to 168
6. Add FIRE ZONE (1) + AMBUSH (2) + FIRE TROUBLE (4) = 7, enter the 7 in location 168
7. Press 2 key to move to 169
8. Add AC FAIL (2) + LOW BAT (4) = 6, enter the 6 in location 169
Report Enable Zone 1 to 4 I _F_
166
I Fire/Duress, Fire Trouble I _7_
168
I
Report Enable Zones 5 to 8
& Panic
I _B_
167
I AC Fail/Low Bat Trouble I _6_
169
I
Restores Enabled
(Blank out this section)
I _ _
170
I _ _
171
I       Misc Restores
(Blank out this section)
I _ _
172
I _ _
173
I                                                                
Zone Restores
(Blank out this section)
I _ _
184
I _ _
185
I

< Report Codes >


Zone 1 Report Code I _3_
000
I _1_
001
I Keypad Police Panic/Zone 8* I _2_
014
I _1_
015
I
Zone 2 Report Code I _3_
002
I _2_
003
I Fire Panic/Smoke Detector** I _2_
016
I _3_
017
I
Zone 3 Report Code I _3_
004
I _3_
005
I Hostage/Duress I _2_
018
I _2_
019
I
Zone 4 Report Code I _3_
006
I _4_
007
I Fire Trouble I _7_
020
I _6_
021
I
Zone 5 Report Code I _3_
008
I _5_
009
I Day Zone Trouble I _ _
022
I _ _
023
I
Zone 6 Report Code I _3_
010
I _6_
011
I Test Timer I _ _
024
I _ _
025
I
Zone 7 Report Code I _ _
012
I _ _
013
I AC Failure I _7_
026
I _9_
027
I
Low Battery I _7_
028
I _8_
029
I
(I_ _I_ _I = Blank out Locations with 5 key) * Police Panic & Zone 8 Report Code share
signal unless Location 080 is set to 1
** Fire Panic & Smoke Detector share same signal

< Restore Codes >


Zone 1 Restore I _ _
040
I _ _
041
I Fire Panic/Smoke Detector I _ _
056
I _ _
057
I
Zone 2 Restore I _ _
042
I _ _
043
I Not Used I _ _
058
I _ _
059
I
Zone 3 Restore I _ _
044
I _ _
045
I Fire Trouble I _ _
060
I _ _
061
I
Zone 4 Restore I _ _
046
I _ _
047
I Medical Panic I _2_
062
I _6_
063
I
Zone 5 Restore I _ _
048
I _ _
049
I Not Used I _ _
064
I _ _
065
I
Zone 6 Restore I _ _
050
I _ _
051
I AC Trouble Restore I _ _
066
I _ _
067
I
Zone 7 Restore I _ _
052
I _ _
053
I Low Battery Restore I _ _
068
I _ _
069
I
Zone 8 Restore/Police Panic I _ _
054
I _ _
055
I
(I_ _I_ _I = Blank out Locations with 5 key)

< Opening/Closings/Cancel >


Closing User 1 I _ _
030
I _ _
031
I Opening User 1 I _D_
070
I _1_
071
I
Closing User 2 I _ _
032
I _ _
033
I Opening User 2 I _D_
072
I _1_
073
I
Closing User 3 I _ _
034
I _ _
035
I Opening User 3 I _D_
074
I _1_
075
I
Closing User 4 I _ _
036
I _ _
037
I Opening User 4 I _D_
076
I _1_
077
I
Force Arm I _ _
038
I _ _
039
I (These are Cancels, see also section 179)
Select User Closings I _ _
174
I Select User Openings I _ _
176
I
(I_ _I_ _I = Blank out Locations with 5 key)

< User Codes >


Hostage/Duress Code I _9_
236
I _9_
237
I
User Program Code
I _1_
238
I _2_
239
I _3_
240
I _4_
241
I _5_
242
I _6_
243
I

This allows customer to change User codes, leave at default

Installer/Dealer Code
I _4_
244
I _5_
245
I _6_
246
I _7_
247
I _8_
248
I _9_
249
I
User Code 1   I _1_
484
I _2_
485
I _3_
486
I _4_
487
I     User Code 2   I _ _
488
I _ _
489
I _ _
490
I _ _
491
I     User Code 3   I _ _
492
I _ _
493
I _ _
494
I _ _
495
I
User Code 4 I _ _
496
I _ _
497
I _ _
498
I _ _
499
I User Code 5 I _ _
500
I _ _
501
I _ _
502
I _7_
503
I

User Codes can be 1, 2, 3 or 4 digits, If User Code 5 is Quick Arm program as 7, customer can
Arm system by pressing 7, do NOT make it anything else or it will screw up other functions!


< Account Numbers >


Telephone Number 1 (Last 4 of Account must be entered in each section)
Group 1 Account     Group 2 Account     Open/Close Account    
I _?_
100
I _?_
101
I _?_
102
I _?_
103
I     I _?_
104
I _?_
105
I _?_
106
I _?_
107
I     I _?_
108
I _?_
109
I _?_
110
I _?_
111
I
Telephone Number 2 (Leave Blank)
Group 1 Account     Group 2 Account     Open/Close Account    
I _ _
132
I _ _
133
I _ _
134
I _ _
135
I I _ _
136
I _ _
137
I _ _
138
I _ _
139
I I _ _
140
I _ _
141
I _ _
142
I _ _
143
I

< Phone Numbers >


Report Format Phone 1 I _9_
112
I _2_
113
I
First Digit Second Digit
Blank = Ademco/Silent Knight Slow Blank = Extended or Single Digit
1 = Sescoa, Vertex, DCI, Franklin 1 = Single Digit
2 = Radionics Fast 2 = 2-Digit (4/2)
3 = Silent Knight Fast 4 = Sumcheck
4 = Radionics, DCI, Franklin Slow
5 = Universal Hi Speed
8 = 2300 Handshake (Add this to above numbers)

Receiver 1 Options I _ _
114
I _ _
115
I (Add D in 114 if delay needed to dial out)
(Add 9 in 115 if 9 is needed to dial out)
Receiver 1 Phone
I _E_
116
I _ _
117
I _ _
118
I _ _
119
I _ _
120
I _ _
121
I _ _
122
I _ _
123
I _ _
124
I _ _
125
I _ _
126
I _ _
127
I _ _
128
I _ _
129
I _ _
130
I _ _
131
I
Report Format Phone 2 I _ _
144
I _ _
145
I (Leave blank)
Receiver 2 Options I _ _
146
I _ _
147
I (Leave blank)
Receiver 2 Phone
I _E_
148
I _ _
149
I _ _
150
I _ _
151
I _ _
152
I _ _
153
I _ _
154
I _ _
155
I _ _
156
I _ _
157
I _ _
158
I _ _
159
I _ _
160
I _ _
161
I _ _
162
I _ _
163
I
Rings before Download I _9_
269
I (9 rings until Answer)
Download Phone
I _ _
270
I _ _
271
I _ _
272
I _ _
273
I _ _
274
I _ _
275
I _ _
276
I _ _
277
I _ _
278
I _ _
279
I _ _
280
I _ _
281
I _ _
282
I _ _
283
I _ _
284
I _ _
285
I

< Misc Functions >


To program sections 084 to 216 see below Diagram

Add location together and enter sum in location
Example: Program Zones 1, 3 4, 5 and 6 for Door Chime
1. Press B/A then B/A again then 8 8 to enter Location 088
2. Add Zone 1 (1) + Zone 2 (2) + Zone 4 (8) = 11 or B, enter B in location 088
3. Press 2 key to move to 089
4. Add Zone 5 (1) + Zone 6 (2) = 3, enter 3 in location 089
Swinger Shutdown I _F_
084
I _F_
085
I (Swinger enabled on all zones)
No EOL Zone Resistors I _ _
086
I _ _
087
I (F 3 = No EOL all Zones, Blank = EOL all zones)
Chime Zones 1 to 6 I _ _
088
I _ _
089
I (Turns on/off chimes per zone)
Never Arm I _ _
090
I _ _
091
I (Leave blank)
PIR Zone I _ _
092
I _ _
093
I (Program PIR zones here. also see 206 – 207)
Untimed Output to Lug E15
I _F_
096
I _F_
097
I _ _
098
I _ _
099
I   (Normally not programmed)
Keypad Sounder on Alarm I _ _
164
I _ _
165
I (Leave blank)
Day Zone I _ _
186
I _ _
187
I (Leave blank)
Priority Zone W/Bypass I _ _
188
I _ _
189
I (Leave blank)
Priority Zone I _F_
190
I _7_
191
I (Default = F 3, leave alone)
Remove Auto-Bypass I _ _
192
I _ _
193
I (Leave blank)
Selective Bypass I _F_
194
I _7_
195
I (Default = F 3, leave alone)
Group Bypass I _?_
196
I _?_
197
I (Any Zone here will bypass by [S] key twice)
24 Hr Protection I _ _
198
I _8_
199
I (Use if Hold-Up buttons on a Zone)
Auto Reset I _F_
200
I _F_
201
I (Default = F D, leave alone)
Entry/Exit Delay 1 Zones I _?_
202
I _?_
203
I (Program which zones are Delay 1)
Entry/Exit Delay 2 Zones I _?_
204
I _?_
205
I (Program which zones are Delay 2)
Interior Follower Zones I _?_
206
I _?_
207
I (Program PIR zones here. also see 092 – 093)
Abort Delay per Zone I _ _
208
I _ _
209
I (Leave blank)
Burglary Output per Zone I _F_
210
I _F_
211
I (FF = Audible Keypad Panic, F7 = Silent Panic)
Relay Output I _ _
212
I _ _
213
I (Leave blank)
7ms Loop Response I _ _
214
I _ _
215
I (Leave blank)
50ms Loop Response I _ _
216
I _ _
217
I (Leave blank)

< Misc Options >


Add each section, place total in box (Example: 1 + 4 + 8 = 13 or “D”)   I_ _I = Blank Out with 5 key
I_4_I
078
1 = Display Day Zone/Reset
2 = Fail to Communicate on NTO Lug
4 = User 5 Quick Arm
8 = User 5 Report as User 1
I_2_I
178
1 = TouchTone Dialing
2 = TouchTone with Rotary Backup
4 = Backup Reporting
8 = Double Reporting

I_ _I
079
1 = User 5 Service Code
2 = Disable Day Zone Report
4 = Reserved
8 = Reserved
I_1_I
179
1 = Opening Report after Alarm
2 = Force Arm
4 = Status Report
8 = Split Report

I_1_I
080
1 = Direct Keypad Panic to Ambush*
2 = Direct Zone 8 to Ambush
4 = Disable Callback Download
8 = Disable Function 6 Download
I_ _I
180
1 = Audible Test on Arming
2 = Auto Reset After Siren Timeout
4 = Power Up in Previous State
8 = Reserved

I_1_I
081
1 = Watch on With Group Bypass
2 = Chime On with Group Bypass
4 = Display Chime Zones
8 = Disable Display Bypass
I_7_I
181
1 = Pulsing Fire
2 = Reset Fire Zone
4 = Enable Keypad Tactical Beeps
8 = Reset Test Timer on Report

I_1_I
082
1 = Enable Download w/Ans Machine
2 = Rem Status LED on NTO Lug
4 = Reserved
8 = Reserved
I_6_I
182
1 = Disable Fault Find
2 = Enable Keypad Panic
4 = Enable Communicator Test
8 = Disable Bell Test

I_ _I
083
1 = Reserved
2 = Reserved
4 = Reserved
8 = Reserved
I_ _I
183
1 = Disable any Bypass/Shunt
2 = No Opening Report after Alarm Zone 6
4 = Include Manual Bypass in ForceArm/Status
8 = Keyswitch Input on Zone 6
*Since Zone 8 and Keypad Panic normally share signal this “splits” Zone 8
into sending standard signal (38) and Police Panic sending Ambush Signal (26)

< System Times >


E/E Times found by dividing desired time by 16
Enter 1st digit of resut in second box and 2nd digit of result in 1st box (wierd ain’t it?)
Sensor Watch I _ _
094
I _ _
095
I (Leave both blank, not used)
Exit Delay I _C_
218
I _3_
219
I (60 seconds)
Entry Delay 1 I _E_
220
I _1_
221
I (30 seconds)
Entry Delay 2 I _E_
222
I _1_
223
I (30 seconds)
Burg Timeout I _6_
224
I _ _
225
I (6 minutes, leave 2nd entry blank)
Fire Timout I _F_
228
I _ _
229
I (Unlimited, leave 2nd entry blank)
Chime Duration I _4_
230
I _ _
231
I (1/2 second Chime, leave 2nd entry blank)
Abort Delay I _ _
232
I _ _
233
I (Leave both blank, not used)
Test Timer I _ _
250
I _ _
251
I (Leave both blank, not used)
Auto Download ID I _ _
252
I _ _
253
I (Leave both blank, not used)