Napco MA1000E Program

Click HERE for Programming Keys
How to Identify Check the inside wiring diagram for exact model
Enter Program 1. Hold 8 key for 3 seconds, keypad will beep
2. Enter 4 5 6 7 8 9, display should show dash on display
Program Location 1. Press [B/A] key display will show 3 dashs
2. Enter 3-digit location (use B/A for any 0)
3. Value currently programmed in location will display
4. Scroll Value UP with 4 key, scroll Value DOWN with 7, blank location with 5
5. When display shows desired Value press 2 to move to next location
(Or B/A + 3-digit location to move to elsewhere)
Programming with
LCD Keypads
LCD layout is slightly different
1 scrolls left 2 scrolls right 5 scrolls data up 9 scrolls data down
Exit Program 1. Hold 8 key 3 seconds, keypad will flash and beep
2. Enter 4 5 6 7 8 9, display should return to normal
Enable Panics Open Keypad cover, cut Jumper “E” (bottom left jumper, clearly marked)
Lockout Bypass 1. Run jumper to pins on large chip marked X (see wiring diagram)
2. Press 9 for 3 seconds, then 8 for 3 seconds and enter 456789
3. LED display should show — , remove jumper and program normallly
(wire MUST be removed to view or change locations)
Zone Page TECH1 Click HERE for List of what below programming will report
IF you have trouble getting in, power down then up, you have 30 seconds to get into programming

< Report Options >


To program REPORT OPTIONS in locations 166 to 185 see below Diagram

Add location together a nd enter sum in location
Example: Enable Reporting for Zones 1 to 6, Keypad Panic, Fire, Duress, Fire Trouble, AC Fail and Low Bat
1. Press B/A then 1 6 6 to move to Location 166
2. Add ZONE 1 (1) + ZONE 2 (2) + ZONE 3 (4) + ZONE 4 (8) = 15 or F, enter the F in location 166
3. Press 2 key to move to 167
4. Add Zone 5 (1) + Zone 6 (2) + Keypad Panic (8) = 11 (B), enter the B in location 167
5. Press 2 key to move to 168
6. Add FIRE ZONE (1) + AMBUSH (2) + FIRE TROUBLE (4) = 7, enter the 7 in location 168
7. Press 2 key to move to 169
8. Add AC FAIL (2) + LOW BAT (4) = 6, enter the 6 in location 169
Report Enable Zone 1 to 4 I _F_
166
I Fire/Duress, Fire Trouble I _7_
168
I
Rprt Enable Zns 5, 6 & Panic I _B_
167
I AC Fail/Low Bat Trouble I _6_
169
I
Restores Enabled
(Blank out this section)
I _ _
170
I _ _
171
I Misc Restores
(Blank out this section)
I _ _
172
I _ _
173
I
Zone Restores
(Blank out this section)
I _ _
184
I _ _
185
I


< Report Codes >


Zone 1 Report Code I _3_
000
I _1_
001
I       Keypad Police Panic I _2_
014
I _1_
015
I
Zone 2 Report Code I _3_
002
I _2_
003
I Fire Panic/Smoke Detector* I _2_
016
I _3_
017
I                                                      
Zone 3 Report Code I _3_
004
I _3_
005
I Hostage/Duress I _2_
018
I _2_
019
I
Zone 4 Report Code I _3_
006
I _4_
007
I Fire Trouble I _7_
020
I _6_
021
I
Zone 5 Report Code I _3_
008
I _5_
009
I Day Zone Trouble I _ _
022
I _ _
023
I
Zone 6 Report Code I _3_
010
I _6_
011
I Test Timer I _ _
024
I _ _
025
I
Not Used I _ _
012
I _ _
013
I AC Failure I _7_
026
I _9_
027
I
Low Battery I _7_
028
I _8_
029
I
(I_ _I_ _I = Blank out Locations with 5 key) *Fire Panic and Smoke Detector share signal if
Smoke Detector uses dedicated Fire Zone


< Restore Codes >


Zone 1 Restore I _ _
040
I _ _
041
I Fire Panic/Smoke I _ _
056
I _ _
057
I
Zone 2 Restore I _ _
042
I _ _
043
I Not Used I _ _
058
I _ _
059
I
Zone 3 Restore I _ _
044
I _ _
045
I Fire Trouble I _ _
060
I _ _
061
I
Zone 4 Restore I _ _
046
I _ _
047
I Medical Panic I _2_
062
I _6_
063
I
Zone 5 Restore I _ _
048
I _ _
049
I Not Used I _ _
064
I _ _
065
I
Zone 6 Restore I _ _
050
I _ _
051
I AC Trouble Restore I _ _
066
I _ _
067
I
Low Battery Restore I _ _
068
I _ _
069
I
(I_ _I_ _I = Blank out Locations with 5 key)


< Opening/Closings/Cancel >


Closing User 1 I _ _
030
I _ _
031
I Opening User 1 I _D_
070
I _1_
071
I
Closing User 2 I _ _
032
I _ _
033
I Opening User 2 I _D_
072
I _1_
073
I
Closing User 3 I _ _
034
I _ _
035
I Opening User 3 I _D_
074
I _1_
075
I
Closing User 4 I _ _
036
I _ _
037
I Opening User 4 I _D_
076
I _1_
077
I
Force Arm I _ _
038
I _ _
039
I (These are Cancels, see also section 179)
Select User Closings I _ _
174
I Select User Openings I _ _
176
I
(I_ _I_ _I = Blank out Locations with 5 key)


< Account Numbers >


Telephone Number 1 (Last 4 of Account must be entered in each section)

Group 1 Account Group 2 Account Open/Close Account
I _?_
100
I _?_
101
I _?_
102
I _?_
103
I   I _?_
104
I _?_
105
I _?_
106
I _?_
107
I   I _?_
108
I _?_
109
I _?_
110
I _?_
111
I
Telephone Number 2 (Leave Blank)

Group 1 Account Group 2 Account Open/Close Account
I _ _
132
I _ _
133
I _ _
134
I _ _
135
I   I _ _
136
I _ _
137
I _ _
138
I _ _
139
I   I _ _
140
I _ _
141
I _ _
142
I _ _
143
I

< Phone Numbers >


Report Format Phone 1 I _9_
112
I _2_
113
I
First Digit Second Digit
Blank = Ademco/Silent Knight Slow Blank = Extended or Single Digit
1 = Sescoa, Vertex, DCI, Franklin 1 = Single Digit
2 = Radionics Fast 2 = 2-Digit (4/2)
3 = Silent Knight Fast 4 = Sumcheck
4 = Radionics, DCI, Franklin Slow
5 = Universal Hi Speed
8 = 2300 Handshake (Add this to above numbers)
Receiver 1 Options I _ _
114
I _ _
115
I (Add D in 114 if delay needed to dial out)
(Add 9 in 115 if 9 is needed to dial out)
Receiver 1 Phone
I _E_
116
I _ _
117
I _ _
118
I _ _
119
I _ _
120
I _ _
121
I _ _
122
I _ _
123
I _ _
124
I _ _
125
I _ _
126
I _ _
127
I _ _
128
I _ _
129
I _ _
130
I _ _
131
I
Report Format Phone 2 I _ _
144
I _ _
145
I (Leave blank)
Receiver 2 Options I _ _
146
I _ _
147
I (Leave blank)
Receiver 2 Phone
I _E_
148
I _ _
149
I _ _
150
I _ _
151
I _ _
152
I _ _
153
I _ _
154
I _ _
155
I _ _
156
I _ _
157
I _ _
158
I _ _
159
I _ _
160
I _ _
161
I _ _
162
I _ _
163
I
Rings before Download I _9_
269
I (9 rings until Answer)
Download Phone 1
I _ _
270
I _ _
271
I _ _
272
I _ _
273
I _ _
274
I _ _
275
I _ _
276
I _ _
277
I _ _
278
I _ _
279
I _ _
280
I _ _
281
I _ _
282
I _ _
283
I _ _
284
I _ _
285
I
Download Phone 2
I _ _
286
I _ _
297
I _ _
288
I _ _
289
I _ _
290
I _ _
291
I _ _
292
I _ _
293
I _ _
294
I _ _
295
I _ _
296
I _ _
297
I _ _
298
I _ _
299
I _ _
300
I _ _
301
I

< Misc Functions >


To program sections 084 to 216 see below Diagram

Add location together and enter sum in location
Example: Program Zones 1, 3 4, 5 and 6 for Door Chime
1. Press B/A then B/A again then 8 8 to enter Location 088
2. Add Zone 1 (1) + Zone 2 (2) + Zone 4 (8) = 11 or B, enter B in location 088
3. Press 2 key to move to 089
4. Add Zone 5 (1) + Zone 6 (2) = 3, enter 3 in location 089
Swinger Shutdown I _F_
084
I _3_
085
I (Swinger enabled on all Zones)
No EOL Zone Resistors I _ _
086
I _ _
087
I (F 3 = No EOL all Zones, Blank = EOL all zones)
Chime Zones 1 to 6 I _ _
088
I _ _
089
I (Turns on/off chimes per zone)
Never Arm I _ _
090
I _ _
091
I (Leave blank)
PIR Zone I _ _
092
I _ _
093
I (Program PIR zones here. also see 206 – 207)
Untimed Output to Lug E15
I _F_
096
I _B_
097
I _ _
098
I _ _
099
I (Normally not programmed)
Keypad Sounder on Alarm I _ _
164
I _ _
165
I (Leave blank)
Day Zone I _ _
186
I _ _
187
I (Leave blank)
Priority Zone W/Bypass I _ _
188
I _ _
189
I (Leave blank)
Priority Zone I _F_
190
I _3_
191
I (Default = F 3, leave alone)
Remove Auto-Bypass I _ _
192
I _ _
193
I (Leave blank)
Selective Bypass I _F_
194
I _3_
195
I (Default = F 3, leave alone)
Group Bypass I _?_
196
I _?_
197
I (Any zone here will bypass by B/A key twice)
24 Hr Protection I _ _
198
I _8_
199
I (Use if Hold-Up buttons on a zone)
Auto Reset I _F_
200
I _D_
201
I (Default = F D, leave alone)
Entry/Exit Delay 1 Zones I _?_
202
I _?_
203
I (Program which zones are Delay 1)
Entry/Exit Delay 2 Zones I _?_
204
I _?_
205
I (Program which zones are Delay 2)
Interior Follower Zones I _?_
206
I _?_
207
I (Program PIR zones here. also see 092 – 093)
Abort Delay per Zone I _ _
208
I _ _
209
I (Leave blank)
Burglary Output per Zone I _F_
210
I _B_
211
I (FB = Audible Keypad Panic, F3 = Silent)
Timed Negative Output I _ _
212
I _ _
213
I (Leave blank)
7ms Loop Response I _ _
214
I _ _
215
I (Leave blank)
50ms Loop Response I _ _
216
I _ _
217
I (Leave blank)


< User Codes >


Hostage/Duress Code I _9_
304
I _9_
305
I
User Program Code
I _1_
306
I _2_
307
I _3_
308
I _4_
309
I _5_
310
I _6_
311
I Allows customer to change User codes, leave default
Installer/Dealer Code
I _4_
312
I _5_
313
I _6_
314
I _7_
315
I _8_
316
I _9_
317
I
User Code 1 I _1_
318
I _2_
319
I _3_
320
I _4_
321
I   User Code 2 I _ _
322
I _ _
323
I _ _
324
I _ _
325
I   User Code 3 I _ _
326
I _ _
327
I _ _
328
I _ _
329
I
User Code 4 I _ _
330
I _ _
331
I _ _
332
I _ _
333
I   User Code 5 I _ _
334
I _ _
335
I _ _
336
I _7_
337
I   User Code 6 I _ _
338
I _ _
339
I _ _
340
I _ _
341
I
User Code 7 I _ _
342
I _ _
343
I _ _
344
I _ _
345
I   User Code 8 I _ _
346
I _ _
347
I _ _
348
I _ _
349
I

User Codes can be 1, 2, 3 or 4 digits, If User Code 5 is Quick Arm program as 7, customer can
Arm system by pressing 7, do NOT make it anything else or it will screw up other functions!


< Misc Options >


Add each section, place total in box (Example: 1 + 4 + 8 = 13 or “D”) I_ _I = Blank Out with 5 key

I _4_
078
I 1 = Display Day Zone/Reset
2 = Reserved
4 = User 5 Quick Arm
8 = User 5 Report as User 1
I _2_
180
I 1 = Audible Test on Arming
2 = Auto-Reset after Timeout
4 = Reserved
8 = Reserved
I _ _
079
I 1 = User 5 Service Code
2 = Disable Day Zone Report
4 = Users 6,7,8 Report as 2,3,4
8 = Reserved
I _7_
181
I 1 = Pulsing Fire
2 = Reset Fire Zone
4 = Enable Keypad Tactical Beeps
8 = Reset Test Timer on any Alarm Report
I _1_
080
I 1 = Disable Low Battery Display*
2 = Reserved
4 = Disable Callback Download
8 = Disable Function 6 Download
I _6_
182
I 1 = Disable Fault Find
2 = Enable Keypad Panic
4 = Enable Communicator Test
8 = Disable Bell Test
I _1_
081
I 1 = Watch on With Group Bypass
2 = Chime On with Group Bypass
4 = Display Open Zones
8 = Disable Display Bypass
I _1_
183
I 1 = Display any Bypass
2 = Reserved
4 = Include Manual Bypass in Force Arm/Status
8 = Keyswitch Input on Zone 5
I _1_
082
I 1 = Enable Download w/Ans Machine
2 = Reserved
4 = Enable Keypad Fire Panic*
8 = Enable Keypad Aux/Medical Panic*
I _6_
236
I 1 = Enable User 8 to PGM Lug
2 = Enable PGM on E/E Delay
4 = Fail to Communicate on PGM Lug
8 = Keypad Sounder on PGM Lug
I _2_
178
I 1 = Touchtone Dialing
2 = Touchtone with Rotary Backup
4 = Backup Reporting
8 = Double Reporting
I _ _
237
I 1 = Ground Start on PGM Lug
2 = Armed LED on PGM Lug
4 = Keypad Aux on PGM Lug
8 = Audio Verification on PGM Lug
I _1_
179
I 1 = Opening after Alarm (see 070 to 077)
2 = Force Arm
4 = Status Report
8 = Split Report
*Panics only work if Jumper E on Keypad is cut
(Jumper E found at bottom left in back of Keypad)
** Panel tends to display low battery if siren sounds
for any length of time

< System Times >


Entry/Exit Times found by dividing desired time by 16 (Or convert it to hex using calculator and put it in backwards)
Enter 1st digit of resut in second box and remainder in 1st box (Anything less than 16 goes in 1st box only)
Sensor Watch I _ _
094
I _ _
095
I (Leave both blank, not used)
Exit Delay I _C_
218
I _3_
219
I (60 seconds)
Entry Delay 1 I _E_
220
I _1_
221
I (30 seconds)
Entry Delay 2 I _E_
222
I _1_
223
I (30 seconds)
Burg Timeout I _6_
224
I _ _
225
I (6 minutes, leave 2nd entry blank)
Fire Timout I _F_
228
I _ _
229
I (Unlimited, leave 2nd entry blank)
Chime Duration I _4_
230
I _ _
231
I (1/2 second Chime, leave 2nd entry blank)
Abort Delay I _ _
232
I _ _
233
I (Leave both blank, not used)
Test Timer I _ _
250
I _ _
251
I (Leave both blank, not used)
Auto Download ID I _ _
252
I _ _
253
I (Leave both blank, not used)
Callback Select I _ _
254
I (Leave blank, not used)