Napco Gem P9600 Basics

Zones 96 hardwired or wireless
Battery
Main Panel 12 volt rechargeable Gel-Cell
Door/Window 1 3-Volt Lithium Model DL123A
Glassbreaks 2 3-Volt Lithium Model DL123A
Motions 2 3-Volt Lithium Model DL123A
Keyfob 2 3-Volt Lithium Flat type (not sure of model)
Remote Panic 2 Energizer 386 1.5-Volt Silver Oxide
Smoke Detector 2 9-volt Alkaline
AC Transformer 16-volts plugged in somewhere in house
Wireless Yes
Downloadable Yes
Panic Buttons
Fire Panic Press 7/F + *
Medical Panic Press 8/A + *
Police Panic Press 9/P + *
Arm Away User Code + ON/OFF (Armed light will turn ON)
(Flashing P means Zone(s) are open)
Arm Stay INTERIOR + User Code + ON/OFF (Interior light will turn ON)
(Flashing P means Zone(s) are open)
Arm Partitions
(If Partitioned)
1. Press 1 to 2 for Partition 1 to 8 (Selects Partition to Arm)
2. Press * + ON/OFF (This move you to that partition)
3. Press User Code + ON/OFF to arm (User Code must have authority in partition)
Arm All
(If Partitioned)
Press 9 + * + User Code + ON/OFF (Arms all Partitions)
Instant Arm User Code + ON/OFF + INSTANT (Armed light will flash rapidly)
Quick Arm Press ON/OFF (If Enabled)
Disarm User Code + ON/OFF (Press RESET to clear mistakes)
(If Partitioned use 0 + * + User Code + ON/OFF)
Silence Alarm User Code + ON/OFF + RESET
Reset Smoke User Code + ON/OFF + RESET twice
Bypass BYPASS + Zone (01 to 96) (Bypassed zone will slowly flash)
or
User Code + BYPASS + Zone (01 to 96)
Siren Test User Code + Function
Press INSTANT until 3 or “Bell Test” appears
Press INTERIOR to sound siren for 2 seconds
Set Time System clock can only be set by installer or by downloading
Door Chime 1. Enter User Code then press FUNCTION to enter Program Menu
2. If LED Keypad press INSTANT until 07 appears in display
IF LCD Keypad press INSTANT until “Activate Chime ?”
3. Press INTERIOR to Enable or Disable
4. Press RESET to exit
Siren Test 1. Enter User Code then press FUNCTION to enter Program Menu
2. If LED Keypad press INSTANT until 03 appears in display
If LCD Keypad press INSTANT until “Activate Bell Test?” appears
3. Press INTERIOR to enable and sound siren for 3 seconds
4. Press RESET to exit
Phone Test 1. Enter User Code then press FUNCTION to enter Program Menu
2. If LED Keypad press INSTANT until 15 appears in display
If LCD Keypad press INSTANT until “Activate Telephone Test?” appears
3. Press INTERIOR to enable Phone Test, if Fail a trouble “3” will appear
4. Press RESET to exit
Sensor Test Arm system and activate sensors
(Wireless motions require no movement for 4 minutes prior to testing)
Keypad Function Menu (User Mode)
To skip a function press INSTANT (No)
To enter a function press INTERIOR (Yes) or ON/OFF
To scroll forward through press FUNCTION, to scroll backwards press BYPASS
To exit press RESETor wait 1 minute

LED Keypads LCD Keypads
01 Display Zone Status? (Displays open zones, press NEXT or PRIOR to scroll)
02 Display Zones Bypassed? (Displays bypassed zones, press NEXT orPRIOR to scroll)
03 Activate Bell Test? (Tests siren, press INTERIOR for 2 second test)
04 Display System Troubles? (Displays 1 or 2 digit trouble code, see TROUBLE section)
05 Display Fire Alarms? (Displays Fire Alarms, press NEXT orPRIOR to scroll)
06 Display Fire Troubles? (Displays Fire Troubles, press NEXT orPRIOR to scroll)
07 Activate Chime? (Turns Door Chime ON and OFF)
08 Activate Watch Mode? (Enables Day Zones, arm then disarm to deactivate)
09 Reset System Trouble? (Manually resets some troubles)
10 (Installers only, normally do not use)
11 Start Exit Time? (Normally do not use)
12 Activate Fault Fine? (Installers only, normally do not use)
13 Activate Locate? (Installers only, normally do not use)
14 Activate EZM Zone Find? (Installers only, normally do not use)
15 Activate Telephone Test? (Sends test signal to central station)
16 Delay Arming 1 – 4 Hours? (Normally do not use)
17 Activate Program? (Enters User Programming from Keypad #1 only)
18 Activate Download? (Begins download, normally do not use)
19 Relay Control? (Turns ON or OFF Relays(light control etc))
To exit press RESET or wait 1 minute