Napco Gem P816 Program

System can be programmed by “Easy Menu” (Click below) or “Advanced” (use below program sheet)
GEM-RP3DGTL Standard Keypad Addressing/Quick Programming
GEM-RP2ASe2 Fixed English Keypad Addressing/Quick Programming
GEM-RP1CAe2 Alpha Keypad Addressing/Quick Programming
Programming of system can only be done by Keypad Address 1
Enter Program 1. 456789 + FUNCTION
2. Press INSTANT until “Activate Program Y/N” or “TURNON PROG Y/N”
3. Press INTERIOR to enter “Easy Menu” Programming
4. or press RESET to enter “Advanced” Programming (see below)
Go to Location 1. Enter 4-digit location (Current value displays)
2. FUNCTION toggles 4-digit location and 2-digit data
3. Enter new data (New value displays)
0 Blanks out a location
4. Press ON/OFF to save (Cursor moves back to 4-digit Location)
5. Press * + INTERIOR for next location or enter new 4-digit location
Exit Program Press RESET twice
Hex Program * + 0 = 0
* + 1 = B
* + 2 = C
* + 3 = D
* + 4 = E
* + 5 = F
Default Dealer
Programming
Address 1197 + ON/OFF (Defaults data and system status only)
(Saves Zone Descriptions & Schedules)
Default Panel Address 1198 + ON/OFF (Defaults everything)

System Times (0 = BLANK)

Exit Delay     I_3_I_C_I    
0000
BLANK BLANK = 0 seconds
BLANK F = 15 seconds
1 E = 30 seconds
2 D = 45 seconds
3 C = 60 seconds
5 *0 = 90 seconds
7 8 = 120 seconds
Entry Delay 1 I_1_I_E_I
0001
Entry Delay 2 I_1_I_E_I
0002
PGM2 Output
Timeout (sec)
I_1_I_E_I
0711
Abort Delay
(sec)
I_0_I_0_I
0715
Sensor Watch
Time (Hrs)
I_0_I_0_I
1059
Report Cancel
Window (sec)
I_0_I_0_I
1179
Chime Time
Time (1/4 sec)
I_0_I_2_I
0716
(02 = 1/2 second Chime Tone)
AC Fail Report
Delay (min)
I_3_I_7_I
0717
(3 7 = 60 minutes)

Zone Expansion

EZM Group 1
(Zones 9 to 12)
I_0_I_?_I
0737
(Enable if using EZM Module or Keypad Zones)
BLANK = No EZM present
1 = 4-Zone EZM
EZM Group 2
(Zones 13 to 16)
I_0_I_?_I
0738

Central Station Information

CS Receiver Phone 1     (20 digits)     (0 = BLANK and must be 1st digit)
I_0_I_?_I
0172
I_0_I_?_I
0173
I_0_I_?_I
0174
I_0_I_?_I
0175
I_0_I_?_I
0176
I_0_I_?_I
0177
I_0_I_?_I
0178
I_0_I_?_I
0179
I_0_I_?_I
0180
I_0_I_?_I
0181
I_0_I_?_I
0182
I_0_I_?_I
0183
I_0_I_?_I
0184
I_0_I_?_I
0185
I_0_I_?_I
0186
I_0_I_?_I
0187
I_0_I_?_I
0188
I_0_I_?_I
0189
I_0_I_?_I
0190
I_0_I_?_I
0191

CS Receiver Phone 2     (20 digits)     (0 = BLANK)
I_0_I_?_I
0194
I_0_I_?_I
0195
I_0_I_?_I
0196
I_0_I_?_I
0197
I_0_I_?_I
0198
I_0_I_?_I
0199
I_0_I_?_I
0200
I_0_I_?_I
0201
I_0_I_?_I
0202
I_0_I_?_I
0203
I_0_I_?_I
0204
I_0_I_?_I
0205
I_0_I_?_I
0206
I_0_I_?_I
0207
I_0_I_?_I
0208
I_0_I_?_I
0209
I_0_I_?_I
0210
I_0_I_?_I
0211
I_0_I_?_I
0212
I_0_I_?_I
0213

CS Receiver Phone 3     (20 digits)     (0 = BLANK)
I_0_I_?_I
0216
I_0_I_?_I
0217
I_0_I_?_I
>
0218
I_0_I_?_I
0219
I_0_I_?_I
0220
I_0_I_?_I
0221
I_0_I_?_I
0222
I_0_I_?_I
0223
I_0_I_?_I
0224
I_0_I_?_I
0225
I_0_I_?_I
0226
I_0_I_?_I
0227
I_0_I_?_I
0228
I_0_I_?_I
0229
I_0_I_?_I
0230
I_0_I_?_I
0231
I_0_I_?_I
0232
I_0_I_?_I
0233
I_0_I_?_I
0234
I_0_I_?_I
0235

CS Telco 1 Opening/Closing Account Number (Use only if sending Opening/Closings, 0 = BLANK)
I_0_I_?_I
0259
I_0_I_?_I
0260
I_0_I_?_I
0261
I_0_I_?_I
0262
CS Telco 1 Event Account Number (Use this for Account Number, 0 = BLANK)
I_0_I_?_I
0267
I_0_I_?_I
0268
I_0_I_?_I
0269
I_0_I_?_I
0270
CS Telco 1 System Event Account Number (Use this for Account Number, 0 = BLANK)
I_0_I_?_I
0275
I_0_I_?_I
0276
I_0_I_?_I
0277
I_0_I_?_I
0278
CS Telco 2 Opening/Closing Account Number (0 = BLANK)
I_0_I_?_I
0279
I_0_I_?_I
0280
I_0_I_?_I
0281
I_0_I_?_I
0282
CS Telco 2 Event Account Number (0 = BLANK)
I_0_I_?_I
0287
I_0_I_?_I
0288
I_0_I_?_I
0289
I_0_I_?_I
0290
CS Telco 2 System Event Account Number (0 = BLANK)
I_0_I_?_I
0295
I_0_I_?_I
0296
I_0_I_?_I
0297
I_0_I_?_I
0298
CS Telco 3 Opening/Closing Account Number (0 = BLANK)
I_0_I_?_I
0299
I_0_I_?_I
0300
I_0_I_?_I
0301
I_0_I_?_I
0302
CS Telco 3 Event Account Number (0 = BLANK)
I_0_I_?_I
0307
I_0_I_?_I
0308
I_0_I_?_I
0309
I_0_I_?_I
0310
CS Telco 3 System Event Account Number (0 = BLANK)
I_0_I_?_I
0315
I_0_I_?_I
0316
I_0_I_?_I
0317
I_0_I_?_I
0318
CS Receiver 1 Format I_0_I_C_I
0170
BLANK (0) = Ademco/Silent Knight Slow (Default)
2 = Radionics Fast
3 = Silent Knight Fast
4 = Radionics, DCI, Franklin Slow
5 = Universal High Speed 4/2
B = SIA
C = Ademco Point ID (Contact ID)
E = Pager
(Use SIA or Contact ID, do NOT use 4/2)
CS Receiver 2 Format I_0_I_C_I
0192
CS Receiver 3 Format I_0_I_C_I
0214
Global Ambush Code I_9_I_9_I
1054
Communicator Options
1 = Cancel Test if Report
2 = Disable Wait for Silence
4 = Disable Wait for Handshake
8 = Disable Dial Tone Detect
I_0_I_4_I
0394
1 = Backup Report to Telco 2
2 = TouchTone Dialing Only
4 = TouchTone w/Rotary Backup
8 = Reserved
Leave below options alone if using SIA or Contact ID
CS Receiver 1 Options
1 = Sumcheck
2 = 3/1 with Extended Restores
4 = Reserved
8 = Reserved
I_0_I_0_I
0171
1 = 1400Hz Handshake
2 = 2300Hz Handshake
4 = Enable Zone Number w/Pulse Alarms
8 = Single Digit Only

CS Receiver 2 Options
1 = Sumcheck
2 = 3/1 with Extended Restores
4 = Reserved
8 = Reserved
I_0_I_0_I
0193
1 = 1400Hz Handshake
2 = 2300Hz Handshake
4 = Enable Zone Number w/Pulse Alarms
8 = Single Digit Only

CS Receiver 3 Options
1 = Sumcheck
2 = 3/1 with Extended Restores
4 = Reserved
8 = Reserved
I_0_I_0_I
0215
1 = 1400Hz Handshake
2 = 2300Hz Handshake
4 = Enable Zone Number w/Pulse Alarms
8 = Single Digit Only

Downloading Options

Rings Before Answer I_0_I_9_I
1183
Digit 1 must be Blank
Digit 2 = 1 to 15 (F) Rings
Callback Phone Number     (20 digits)     (0 = BLANK)
I_ _I_ _I
0236
I_ _I_ _I
0237
I_ _I_ _I
0238
I_ _I_ _I
0239
I_ _I_ _I
0240
I_ _I_ _I
0241
I_ _I_ _I
0242
I_ _I_ _I
0243
I_ _I_ _I
0244
I_ _I_ _I
0245
I_ _I_ _I
0246
I_ _I_ _I
0247
I_ _I_ _I
0248
I_ _I_ _I
0249
I_ _I_ _I
0250
I_ _I_ _I
0251
I_ _I_ _I
0252
I_ _I_ _I
0253
I_ _I_ _I
0254
I_ _I_ _I
0255

Report Codes

Alarm, Restore, Trouble I_1_I_1_I
0319
RF Receiver Trouble I_0_I_0_I
0334
Trouble I_1_I_1_I
0320
Memory Failure I_1_I_1_I
0335
Trouble Restore I_1_I_1_I
0321
Panel Low Battery I_1_I_1_I
0336
Xmitter Low Battery I_0_I_0_I
0322
Panel AC Failure I_1_I_1_I
0337
Xmitter Supervision I_0_I_0_I
0323
EZM Expander Tamper I_1_I_1_I
0338
Xmitter Tamper I_1_I_1_I
0324
Alarm Output Supervision I_1_I_1_I
0339
For Future Use I_0_I_0_I
0325
Ambush/Duress I_1_I_1_I
0340
Opening I_0_I_0_I
0326
Police Panic I_1_I_1_I
0341
Closing I_0_I_0_I
0327
Fire Panic I_1_I_1_I
0342
Opening After Alarm I_1_I_1_I
0328
Auxiliary (General) Panic I_1_I_1_I
0343
Conditional Close I_1_I_1_I
>
0329
Tamper I_1_I_1_I
0344
Cancel I_1_I_1_I
0330
Fail to Open I_0_I_0_I
0345
Test Timer I_1_I_1_I
0332
Fail to Close I_0_I_0_I
0346
Telco Failure I_0_I_1_I
0333
Low Keyfob Battery I_0_I_0_I
0347
Zone 1
I_3_I_0_I
0358
Zone 2
I_3_I_0_I
0359
Zone 3
I_3_I_0_I
0360
Zone 4
I_3_I_0_I
0361
Zone 5
I_3_I_0_I
0362
Zone 6
I_3_I_0_I
0363
Zone 7
I_3_I_0_I
0364
Zone 8
I_3_I_0_I
0365
Zone 9
I_3_I_0_I
0366
Zone 10
I_3_I_0_I
0367
Zone 11
I_3_I_0_I
0368
Zone 12
I_3_I_0_I
0369
Zone 13
I_3_I_0_I
0370
Zone 14
I_3_I_0_I
0371
Zone 15
I_3_I_0_I
0372
Zone 16
I_3_I_0_I
0373
Contact ID or SIA Codes (enter below for 1st digit, 2nd digit doesn’t matter, blank with 0)

1 = Fire 7 = Gas Alarm
2 = Panic (Audible) 8 = Heat Alarm
3 = Burglary 0 = Auxiliary Alarm
4 = Hold Up (Silent) B = 24 Hour Auxiliary Alarm

Zone Options

(Add together for total, Example: to make Zones 1 to 4 Priority Zones enter 0 F in 0490)
50ms Loop Response I_0_I_0_I
0490
Priority Zone I_0_I_0_I
0491
I_0_I_0_I
0546
Priority with Bypass I_0_I_0_I
0492
I_0_I_0_I
0547
Auto-Bypass I_?_I_?_I
0493
I_?_I_?_I
0548
Selective Bypass I_F_I_F_I
0494
I_F_I_F_I
0549
Keyswitch Arming I_0_I_0_I
0495
I_0_I_0_I
0550
Auto-Bypass Re-Entry I_0_I_0_I
0496
I_0_I_0_I
0551
Pre-Alarm Warning I_0_I_0_I
0497
I_0_I_0_I
0552
Never Arm I_0_I_0_I
0498
I_0_I_0_I
0553
24-Hour Zone (Fire/Panics) I_?_I_?_I
0499
I_?_I_?_I
0554
Alarm Output I_F_I_F_I
0500
I_F_I_F_I
0555
Pulsed Alarm Output I_F_I_F_I
0501
I_F_I_F_I
0556
PGM1 Output I_0_I_0_I
0502
I_0_I_0_I
0557
PGM2 Output I_0_I_0_I
0503
I_0_I_0_I
0558
Entry/Exit 1 I_?_I_?_I
0504
I_?_I_?_I
0559
Entry/Exit 2 I_?_I_?_I
0505
I_?_I_?_I
0560
Entry/Exit Follower I_?_I_?_I
0506
I_?_I_?_I
0561
Auto Reset I_0_I_0_I
0507
I_0_I_0_I
0562
Swinger Shutdown I_F_I_F_I
0508
I_F_I_F_I
0563
Chime Zone I_?_I_?_I
0509
I_?_I_?_I
0564
Abort Delay I_0_I_0_I
0510
I_0_I_0_I
0565
Power-Up Delay I_0_I_0_I
0511
I_0_I_0_I
0566
Day Zone Open I_0_I_0_I
0512
I_0_I_0_I
0567
Day Zone Short I_0_I_0_I
0513
I_0_I_0_I
0568
Alarm on Day Zone I_0_I_0_I
0514
I_0_I_0_I
0569
Alarm Telco 1 I_F_I_F_I
0515
I_F_I_F_I
0570
Alarm Restore Telco 1 I_0_I_0_I
0516
I_0_I_0_I
0571
Trouble Telco 1 I_F_I_F_I
0517
I_F_I_F_I
0572
Trouble Restore 1 I_0_I_0_I
0518
I_0_I_0_I
0573
Alarm Telco 3 I_0_I_0_I
0519
I_0_I_0_I
0574
Alarm Restore Telco 3 I_0_I_0_I
0520
I_0_I_0_I
0575
Trouble Telco 3 I_0_I_0_I
0521
I_0_I_0_I
0576
Trouble Rest Telco 3 I_0_I_0_I
0522
I_0_I_0_I
0577
No EOL Resistor I_?_I_?_I
0523
I_?_I_?_I
0578
Trouble on Open I_0_I_0_I
0524
I_0_I_0_I
0579
Trouble on Short I_0_I_0_I
0525
I_0_I_0_I
0580
Zone Area 1
(OFF = Zone Disabled)
I_?_I_?_I
0526
I_?_I_?_I
0581
Reserved Future Use I_0_I_0_I
0528
I_0_I_0_I
0583
Keypad Sounder on Alarm I_F_I_F_I
0529
I_F_I_F_I
0584
2-Wire Smoke (Zone 7 & 8 Only) I_?_I_0_I
0530
I_0_I_0_I
0585
Fire Zone I_?_I_?_I
0531
I_?_I_?_I
0586
Fire Alarm Verification I_0_I_0_I
0532
I_0_I_0_I
0587
Reserved Future Use I_0_I_0_I
0533
I_0_I_0_I
0588
Sensor Watch I_0_I_0_I
0538
I_0_I_0_I
0593
Reserved Future Use I_0_I_0_I
0539
I_0_I_0_I
0594
Chime 2 I_0_I_0_I
0540
I_0_I_0_I
0595

CS Area & System Reporting Options

1 = Reserved
2 = Autoarm if not closed at window
4 = Disable Time/Date at Keypad
8 = Disable Zone Fault Scrolling
I_0_I_0_I
0718
1 = Opening only after Alarm
2 = Closing only w/Conditional Close
4 = Incl Sel/Grp Bypass
8 = Status Report

1 = Access Control on PGM2
2 = Maintained Keyswitch Arming
4 = Reserved
8 = Disable Keypad Instant Mode
I_0_I_0_I
0719
1 = Auto Bell Test at Arming
2 = Reset after Burg Output Timeout
4 = Supress Byp Reminder w/Armed
8 = Reserved

1 = Disable Keypad Download
2 = Disable Callback Download
4 = PGM2 Output Chirp on Keyfob Arming
8 = Change Pulse Output to Cadence
I_0_I_C_I
0720
1 = Reserved
2 = Enable Global Ambush Code
4 = Reset Day Zone with Arm/Disarm
8 = Enable Residential Fire

1 = Line Fault Test w/Armed
2 = Enable Line Fault Test
4 = Inhibit Trouble Audible at Keypad
8 = Reserved
I_0_I_0_I
0721
1 = Reserved
2 = Wireless Trble Activates Telco 1
4 = Wireless Trble Activates Telco 3
8 = Enable Alarm Output on Telco
Fail only when Armed

1 = Don’t Clear PGM2 on
     Arm/Disarm
2 = 2nd Ring Download
4 = Reserved
8 = Reserved Smoke Low Battery

I_0_I_0_I
0722
1 = Reserved
2 = Veriphone Zones Trip PGM2
4 = Veriphone Zns over Priority Alarm
8 = Resound on Wireless Smoke

Reserved, leave Blank I_0_I_1_I
1060
1 = Enable Set Time/Date Message
2 = Enable Cancel Report to Telco 3
4 = Reserved
8 = Enable GEM-PRINT Module

Keypad Options (0 = BLANK)

Keypad 1 Type I_0_I_1_I
0723
Left digit
BLANK = Burg Keypad
2 = Wizard (Remote access module)

Right digit
BLANK = Keypad Disabled
1 = Active Keypad

Keypad 2 Type I_0_I_?_I
0724
Keypad 3 Type I_0_I_?_I
0725
Keypad 4 Type I_0_I_?_I
0726
Keypad 5 Type I_0_I_?_I
0727
Keypad 6 Type I_0_I_?_I
0728
Keypad 7 Type I_0_I_?_I
0729
Keypad 1 1 = Enable Ambush
2 = Easy Arming (Quick Arm)
4 = Panel Access (User Program)
8 = Reserved
I_7_I_7_I
0730
1 = Keypad Fire Enable
2 = Keypad Medical Enable
4 = Keypad Panic Enable
8 = Reserved

Keypad 2 1 = Enable Ambush
2 = Easy Arming (Quick Arm)
4 = Panel Access (User Program)
8 = Reserved
I_7_I_7_I
0731
1 = Keypad Fire Enable
2 = Keypad Medical Enable
4 = Keypad Panic Enable
8 = Reserved

Keypad 3 1 = Enable Ambush
2 = Easy Arming (Quick Arm)
4 = Panel Access (User Program)
8 = Reserved
I_7_I_7_I
0732
1 = Keypad Fire Enable
2 = Keypad Medical Enable
4 = Keypad Panic Enable
8 = Reserved

Keypad 4 1 = Enable Ambush
2 = Easy Arming (Quick Arm)
4 = Panel Access (User Program)
8 = Reserved
I_7_I_7_I
0733
1 = Keypad Fire Enable
2 = Keypad Medical Enable
4 = Keypad Panic Enable
8 = Reserved

Keypad 5 1 = Enable Ambush
2 = Easy Arming (Quick Arm)
4 = Panel Access (User Program)
8 = Reserved
I_7_I_7_I
0734
1 = Keypad Fire Enable
2 = Keypad Medical Enable
4 = Keypad Panic Enable
8 = Reserved

Keypad 6 1 = Enable Ambush
2 = Easy Arming (Quick Arm)
4 = Panel Access (User Program)
8 = Reserved
I_7_I_7_I
0735
1 = Keypad Fire Enable
2 = Keypad Medical Enable
4 = Keypad Panic Enable
8 = Reserved

Keypad 7 1 = Enable Ambush
2 = Easy Arming (Quick Arm)
4 = Panel Access (User Program)
8 = Reserved
I_7_I_7_I
0736
1 = Keypad Fire Enable
2 = Keypad Medical Enable
4 = Keypad Panic Enable
8 = Reserved

User Reporting Options (Add together for total, Example: to make Users 1 to 4 Priority Zones enter 0 F in 0440)

         
Opening Telco 1 I_0_I_0_I
0440
I_0_I_0_I
0441
I_0_I_0_I
0444
Closing Telco 1 I_0_I_0_I
0445
I_0_I_0_I
0446
I_0_I_0_I
0449
Opening Telco 3 I_0_I_0_I
0450
I_0_I_0_I
0451
I_0_I_0_I
0454
Closing Telco 3 I_0_I_0_I
0455
I_0_I_0_I
0456
I_0_I_0_I
0459
Disable Opening
Reports
I_1_I_0_I
0391
Left Digit 1 = Area 1
Right Digit 0 = Disabled (Not Used)
Disable Closing
Reports
I_1_I_0_I
0392
Left Digit 1 = Area 1
Right Digit 0 = Disabled (Not Used)

RF Receiver & Supervisory Timer Options

Number of RF
Receivers
I_0_I_0_I
1180
Digit 1   must be Blank
Digit 2 1 for 1 RF Receiver
2 for 2 RF Receivers