Napco Gem P800 Basics

Zones GEM-P400 – 4 hardwired or wireless (usually hardwired)
GEM-P800 – 8 hardwired or wireless
Battery
Main Panel 12 volt rechargeable Gel-Cell
Door/Window 1 3-Volt Lithium Model DL123A
Glassbreaks 2 3-Volt Lithium Model DL123A
Motions 2 3-Volt Lithium Model DL123A
Keyfob 2 3-Volt Lithium Flat type (not sure of model #)
Remote Panic 2 Energizer 386 1.5-Volt Silver Oxide
Smoke Detector 2 9-volt Alkaline
AC Transformer 16-volts plugged in somewhere in house
Wireless Yes
Downloadable Yes
Panic Buttons
Fire Panic Press 7/F + *
Medical Panic Press 8/A + *
Police Panic Press 9/P + *
Arm User Code + ON/OFF (Armed light will turn on)
Stay Arm User Code + ON/OFF + BYPASS
Instant Arm User Code + ON/OFF + INSTANT (Armed light will flash rapidly)
Disarm User Code + ON/OFF (Press RESET to clear mistakes)
Silence Alarm User Code + ON/OFF (Press RESET to clear Alarm Display)
Quick Arm FUNCTION + 0
Easy Exit FUNCTION + 0 (Allows leaving without disarming)
Bypass BYPASS + Zone (1 to 8) (bypassed zone will slowly flash)
Door Chime FUNCTION + 5 to turn ON or OFF
Enable/Disable
Keypad Sounds
Function + 9
Reset Smoke Press RESET (If this does not work powere down, set for service)
System Test Function + 1 (Tests Siren and Battery only)
Sensor Test None, Arm system then trip sensors
(Wireless motions require no movement for 4 minutes prior to testing)