Napco Gem P400 Program

Enter Program Press FUNCTION + 8 + 4567 + ON/OFF Key
(Keypad should sound 3 quick beeps, ARMED light will turn On, Trouble will Flash)
Exit Program RESET + FUNCTION + 8 + <Installer Code> + ON/OFF
Move TO Location RESET + 2-digit location
Move IN Location Press INTERIOR
Delete Location Press INSTANT
Default Panel 1. Power down and jumper terminal 15 to terminal 3
2. Power up, after 10 seconds ARMED, READY SYSTEM will flash + 3 beeps
3. Power back down, return wiring back to normal then power up again
(If this does not work system is locked out)
Hex Digits A=* 1, B=* 2, C=* 3, D=* 4, E=* 5, F=* 6

00 Entry/Exit Zones (Toggle Options ON/OFF)
Default
ON
OFF
OFF
OFF
I_ON_I
I_OFF_I
I_OFF_I
I_OFF_I  
Zone 1
Zone 2
Zone 3
Zone 4
ON = Zone is a Delay Entry/Exit Zone
OFF= Zone is not Delay Entry/Exit Zone
01 Home/Away with Delay Zones (Auto-Bypasses Motion Zones)
Default
OFF
OFF
OFF
OFF
I_OFF_I
I_OFF_I
I_OFF_I
I_OFF_I
Zone 1
Zone 2
Zone 3
Zone 4
ON = Zone is Home/Away with Delay
OFF= Zone is not Home/Away with Delay
02 Entry/Exit Follower Zones (Enable for any Motion Zones)
Default
OFF
OFF
OFF
OFF
I_OFF_I
I_OFF_I
I_OFF_I
I_OFF_I
Zone 1
Zone 2
Zone 3
Zone 4
ON = Zone is Entry/Exit Follower Zone
OFF= Zone is not Entry/Exit Follower Zone
03 Auto Bypass Re-Entry Zones (Normally turn all lights OFF)
Default
OFF
OFF
OFF
OFF
I_OFF_I
I_OFF_I
I_OFF_I
I_OFF_I
Zone 1
Zone 2
Zone 3
Zone 4
ON = Zone is Entry/Exit Follower Zone
OFF= Zone is not Entry/Exit Follower Zone
04 24 Hour Zones (Toggle 1 to 4 ON for Panic Zones)
Default
OFF
OFF
OFF
OFF
I_OFF_I
I_OFF_I
I_OFF_I
I_OFF_I
Zone 1
Zone 2
Zone 3
Zone 4
ON = Zone is 24 Hour Zones
OFF= Zone is not 24 Hour Zones

(This system does NOT support Smoke Detectors)

05 40 ms Loop Response (Normally turn all lights OFF)
Default
OFF
OFF
OFF
OFF
I_OFF_I
I_OFF_I
I_OFF_I
I_OFF_I
Zone 1
Zone 2
Zone 3
Zone 4
ON = Zone has 40 ms Loop Response
OFF= Zone has Normal Loop Response
06 Open Circuit Zones (Normally turn all lights OFF)
Default
OFF
OFF
OFF
OFF
I_OFF_I
I_OFF_I
I_OFF_I
I_OFF_I
Zone 1
Zone 2
Zone 3
Zone 4
ON = Zone is a Normally Open Zone
OFF= Zone is a Normally Closed Zone
07 Burglary Steady Output (Normally turn all lights ON)
Default
ON
ON
ON
ON
I_ON_I
I_ON_I
I_ON_I
I_ON_I
Zone 1
Zone 2
Zone 3
Zone 4
ON = Zone Alarm is Steady SirenOutput
OFF= Alarm is Silent

(If Silent Panic or Holdup toggle zone light OFF)

08 PGM Output (Normally turn all lights ON)
Default
ON
ON
ON
ON
I_ON_I
I_ON_I
I_ON_I
I_ON_I
Zone 1
Zone 2
Zone 3
Zone 4
ON = PGM Enabled on Zone Trip until Reset
OFF= PGM not Enabled on Zone Trip
10 Exit Delay I_0_I_6_I_0_I (001 to 255 Seconds)
11 Entry Delay I_0_I_3_I_0_I (001 to 255 Seconds)
12 Bell/Siren Timeout I_0_I_0_I_6_I (001 to 255 Minutes)
13 Reserved Do Not Program
14 Test Timer Interval I_0_I_0_I_1_I (001 to 255 Days)
15 Line Cut Time (Phone Monitor) I_0_I_0_I_0_I (010 to 255 Seconds 000=Disable)
16 Wireless Supervisory Timer I_1_I_2_I (01 to 26 in Hours)
20 Keypad Features 1 (Toggle Options ON/OFF)
Default
OFF
OFF
ON
OFF
I_ON_I
I_ON_I
I_ON_I
I_ON_I
Keypad Panic 2 Enabled (Can be Fire Panic I guess)
Keypad Medical Enabled
Keypad Police Panic Enabled
Ambush is 4th User Code
21 Keypad Features 2 (Toggle Options ON/OFF)
Default
ON
OFF
ON
OFF
I_ON_I
I_ON_I
I_ON_I
I_OFF_I
Keypad Panic Audible
Entry Delay with Urgency Beeps
Display Bypass while Armed
Disable Keypad Keypress Beeps
22 Miscellaneous Features 1 (Toggle Options ON/OFF)
Default
OFF
ON
ON
OFF
I_OFF_I
I_ON_I
I_ON_I
I_ON_I
Abort Delay
Easy Arm/Easy Exit (Quick Arm/Quick Exit)
Swinger Shutdown Enabled
Bell on Phone Line Cut if Armed
23 PGM Features 1 (Toggle Options ON/OFF)
Default
OFF
ON
ON
OFF
I_OFF_I
I_ON_I
I_ON_I
I_OFF_I
Audio Verification (If using Variphone 2-way Board)
Access Output to PGM for 5 seconds with FUNCTION + 3
PGM Follows Keypad Sounder
Keyfob/Keyswitch Chirp (1 Chirp if Armed, 2 Chirps if Disarmed)
24 PGM Features 2 (Toggle Options ON/OFF)
Default
OFF
OFF
OFF
OFF
I_OFF_I
I_OFF_I
I_OFF_I
I_OFF_I
Reserved (Leave OFF)
PGM Activates on AUX Alarm
PGM Activates on Panic Alarm
PGM Activates during Test Timer Report
25 PGM Features 3 (Toggle Options ON/OFF)
Default
OFF
OFF
OFF
OFF
I_OFF_I
I_OFF_I
I_OFF_I
I_OFF_I
PGM Activates 15 Minutes after AC Fail
PGM Activates on Low Battery
PGM Activates on a Trouble Condition
PGM Activates if System Armed
26 Miscellaneous Features 2 (Toggle Options ON/OFF)
Default
OFF
OFF
OFF
OFF
I_OFF_I
I_OFF_I
I_OFF_I
I_OFF_I
Momentary Keyswitch Arming
Reserved (Leave OFF)
Inhibit Fail to Communicate Display
Inhibit Low Battery Display
30 Account 1 (Last 4 of Account) I_ _I_ _I_ _I_ _I
31 Receiver Phone 1 (12 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
(Press INSTANT to erase Digits) 4 Second Pause = D (* 4)
32 Receiver Format Phone 1

Default
4

I_6_I  
0 = Disabled 4 = Universal High Speed
1 = Ademco Slow 5 = Reserved
2 = Radionics Slow 6 = Contact ID
3 = Silent Knight Fast 7 = Pager
33 Receiver 1 Options (Toggle Options ON/OFF)
Default
ON
OFF
OFF
OFF
I_ON_I
I_OFF_I
I_OFF_I
I_OFF_I
2300 Handshake/Kissoff
Sumcheck
Single Digit
No Handshake/Pager Enabled
34 Zone Report Enable Phone 1 (Toggle Options ON/OFF)
Default
ON
ON
ON
ON
I_ON_I
I_ON_I
I_ON_I
I_ON_I
Zone 1
Zone 2
Zone 3
Zone 4
ON = Zone Alarms sent to Phone 1
OFF= Zone Alarms not sent to Phone 1
35 Zone Restore Phone 1 (Toggle Options ON/OFF)
Default
OFF
OFF
OFF
OFF
I_OFF_I
I_OFF_I
I_OFF_I
I_OFF_I
Zone 1
Zone 2
Zone 3
Zone 4
ON = Zone Restorals sent to Phone 1
OFF= Zone Restorals not sent to Phone 1
36 System Reporting Phone 1 (Toggle Options ON/OFF)
Default
OFF
OFF
ON
OFF
I_ON_I
I_ON_I
I_ON_I
I_OFF_I
Keypad Fire Panic Report Enable
Keypad Medical Panic Report Enable
Keypad Police Panic Report Enable
Test Timer Report Enable
37 System Reporting Phone 1 (Toggle Options ON/OFF)
Default
OFF
ON
OFF
OFF
I_ON_I
I_ON_I
I_ON_I
I_OFF_I
AC Fail Report Enable (15 Min Delay)
Low Battery Report Enable
Trouble Report Enable
Reserved
38 System Restore Report Phone 1 (Toggle Options ON/OFF)
Default
OFF
OFF
OFF
OFF
I_OFF_I
I_OFF_I
I_OFF_I
I_OFF_I
AC Fail Restore Enable (15 Min Delay)
Low Battery Restore Enable
Trouble Restore Enable
Reserved
39 Open/Close Report Phone 1 (Toggle Options ON/OFF)
Default
OFF
OFF
OFF
OFF
I_OFF_I
I_OFF_I
I_OFF_I
I_OFF_I
User 1 Reporting
User 2 Reporting
User 3 Reporting
User 4 Reporting
ON= Opening/Closings for this User Enabled
OFF= Opening/Closings for this User Disabled
40 Account 2 (Do not Program) I_ _I_ _I_ _I_ _I
41 Receiver Phone 2 (12 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
Do not program Pager here, use Phone 3 instead
42 Receiver Format Phone 2

Default
4

I_7_I
0 = Disabled 4 = Universal High Speed
1 = Ademco Slow 5 = Reserved
2 = Radionics Slow 6 = Contact ID
3 = Silent Knight Fast 7 = Pager
43 Receiver 2 Options (Toggle Options ON/OFF)
Default
ON
OFF
OFF
OFF
I_ON_I
I_OFF_I
I_OFF_I
I_OFF_I
2300 Handshake/Kissoff
Sumcheck
Single Digit
No Handshake/Pager Enabled
44 Dialing Prefix Phone 1, 2 & 3 I_ _I_ _I_ _I_ _I
(enter 9 here if needed to dial out)
cellspacing=”5″

45 Communicator Features 1 (Toggle Options ON/OFF)
Default
ON
ON
OFF
OFF
I_ON_I
I_ON_I
I_OFF_I
>
I_OFF_I
Communicator Enabled
DTMF with Rotary Backup
DTMF Only
Backup to Telco 2
46 Communicator Features 2 (Toggle Options ON/OFF)
Default
OFF
OFF
OFF
OFF
I_OFF_I
I_OFF_I
I_OFF_I
I_OFF_I
No Dial Tone Detection
2:1 Rotary Dialing
Backup if Less than 4 Attempts
Reserved
50 Account 3 (Do not Program) I_ _I_ _I_ _I_ _I
51 Receiver Phone 3 (12 digits) I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
(If using Pager add pauses (* 4) after number, 3 should work)
52 Receiver Format Phone 3

Default
4

I_7_I
0 = Disabled 4 = Universal High Speed
1 = Ademco Slow 5 = Reserved
2 = Radionics Slow 6 = Contact ID
3 = Silent Knight Fast 7 = Pager
53 Receiver 3 Options (Toggle Options ON/OFF)
Default
ON
OFF
OFF
OFF
I_OFF_I
I_OFF_I
I_OFF_I
I_OFF_I
2300 Handshake/Kissoff
Sumcheck
Single Digit
No Handshake/Pager Enabled
54 Zone Report Phone 3 (Toggle Options ON/OFF)
Default
OFF
OFF
OFF
OFF
I_OFF_I
I_OFF_I
I_OFF_I
I_OFF_I
Zone 1
Zone 2
Zone 3
Zone 4
ON = Zone Alarms sent to Phone 3
OFF= Zone Alarms not sent to Phone 3
55 Zone Restore Phone 3 (Toggle Options ON/OFF)
Default
OFF
OFF
OFF
OFF
I_OFF_I
I_OFF_I
I_OFF_I
I_OFF_I
Zone 1
Zone 2
Zone 3
Zone 4
ON = Zone Restorals sent to Phone 3
OFF = Zone Restorals not sent to Phone 3
56 System Report Phone 3 (Toggle Options ON/OFF)
Default
OFF
OFF
OFF
OFF
I_OFF_I
I_OFF_I
I_OFF_I
I_OFF_I
Keypad Fire Panic Report Enable
Keypad Medical Panic Report Enable
Keypad Police Panic Report Enable
Test Timer Report Enable
57 System Report Phone 3 (Toggle Options ON/OFF)
Default
OFF
OFF
OFF
OFF
I_OFF_I
I_OFF_I
I_OFF_I
I_OFF_I
AC Fail Report Enable (15 Min Delay)
Low Battery Report Enable
Trouble Report Enable
Reserved
58 System Restore Phone 3 (Toggle Options ON/OFF)
Default
OFF
OFF
OFF
OFF
I_OFF_I
I_OFF_I
I_OFF_I
I_OFF_I
AC Fail Report Enable (15 Min Delay)
Low Battery Report Enable
Trouble Report Enable
Reserved
59 Open/Close Reports Phone 3 (Toggle Options ON/OFF)
Default
OFF
OFF
OFF
OFF
I_OFF_I
I_OFF_I
I_OFF_I
I_OFF_I
User 1 Reporting
User 2 Reporting (Turn this section ON for if using Pager)
User 3 Reporting
User 4 Reporting
60 Zone Report Codes (Only used if 4/2 format is selected in section 32)
Default
3
3
3
3
I_3_I
I_3_I
I_3_I
I_3_I
Zone 1 Alarm Report Code (This is 1st digit, 2nd digit sent automatically)
Zone 2 Alarm Report Code
Zone 3 Alarm Report Code
Zone 4 Alarm Report Code
61 Contact ID Report Codes (Only used if Contact ID is selected in section 32)
Default
3
3
3
3
3
3
I_3_I
I_3_I
I_3_I
I_3_I
I_3_I
I_3_I
Zone 1 Alarm Report Code
Zone 2 Alarm Report Code
Zone 3 Alarm Report Code
Zone 4 Alarm Report Code
Zone 5 Alarm Report Code
Zone 6 Alarm Report Code
Contact ID Report Codes (1st digit, 2nd is Zone)

1 = Reserved
2 = Panic
3 = Burglary
4 = Holdup
5 = General Alarm
6 = Reserved
7 = Gas Alarm
8 = Heat Alarm
9 = Reserved
A = Auxiliary
B = 24 Hr Alarm
62 Zone Restore/Trouble Codes
Default
E
F
I_0_I
I_0_I
Zone 1, 2, 3, 4 Restore Code
Zone 1, 2, 3, 4 Trouble Code
63 System Report Codes (Auto-reports regardless of report code if Contact ID is used)
Default
11
23
21
FF
F9
F8
F1
I_1_I_1_I
I_2_I_3_I
I_2_I_1_I
I_F_I_F_I
I_F_I_9_I
I_F_I_8_I
I_F_I_1_I
Keypad Fire Panic (7/F & *)
Keypad Aux Panic (8/A & *)
Keypad Police Panic (97P & *)
Test Timer
AC Failure
Low Battery
Trouble (Receiver Fail/Tamper/Wireless Low Bat)
64 System Restore Code
Default
E I_0_I (Receiver Fail/Tamper/Wireless Low Bat)
65 Open/Close Code
Default
C
B
I_0_I
I_0_I
Closing Report Code
Opening Report Code
66 Ambush/Duress Code
Default
22 I_2_I_2_I
67 Enhanced Communication Phone 1 (Toggle Options ON/OFF)
Default
OFF
OFF
OFF
OFF
I_OFF_I
I_OFF_I
I_OFF_I
I_OFF_I
Opening After Alarm (Enable Cancel)
Conditional Closing
Reserved
Reserved
68 Enhanced Communication Phone 3 (Toggle Options ON/OFF)
Default
OFF
OFF
OFF
OFF
I_OFF_I
I_OFF_I
I_OFF_I
I_OFF_I
Opening After Alarm
Conditional Closing
Reserved
Reserved
Wireless Programming   (Wireless AND Hardwired devices can occupy the same zone)
Sample Sensor
71 Zone 1 Wireless Serial Number Serial Number
I_ _I_ _I_ _I_ _I_ _I_ _I : I_ _I
Point
I_ _I
Internal Reed
External Sensors
Smoke Detector
Motion Detector
Glassbreaks
= Point 1
= Point 2
= Point 1
= Point 1
= Point 1
Program sensor by entering 7-Digit Serial Number + Point
Strap off External Sensor Terminals if using Internal Point
72 Zone 2 Wireless Serial Number I_ _I_ _I_ _I_ _I_ _I_ _I : I_ _I I_ _I
73 Zone 3 Wireless Serial Number I_ _I_ _I_ _I_ _I_ _I_ _I : I_ _I I_ _I
74 Zone 4 Wireless Serial Number I_ _I_ _I_ _I_ _I_ _I_ _I : I_ _I I_ _I
Aux
Serial Number 1 2
81 Keyfob 1 Serial Number I_ _I_ _I_ _I_ _I_ _I_ _I_ _I I_ _I_ _I
82 Keyfob 2 Serial Number I_ _I_ _I_ _I_ _I_ _I_ _I_ _I I_ _I_ _I
83 Keyfob 3 Serial Number I_ _I_ _I_ _I_ _I_ _I_ _I_ _I I_ _I_ _I
84 Keyfob 4 Serial Number I_ _I_ _I_ _I_ _I_ _I_ _I_ _I I_ _I_ _I
Top 2 buttons = ARM & DISARM, bottom, 2 = AUX 1 & 2 can be programmed for several functions

1 = Police Panic
2 = Aux/Medical
3 = Bell ON
4 = PGM Output
5 = Access on PGM
7 = FULLY ARM (Use ON key + Selected AUX key programmed as 7
8 = STAY ARM (Use ON key + Selected AUX key programmed as 8
90 Download Phone Number I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
91 Ring Count
Default
09 I_0_I_9_I (00 to 15)
92 Downloading Features (Toggle Options ON/OFF)
Default
ON
OFF
OFF
OFF
I_ON_I
I_ON_I
I_ON_I
I_OFF_I
Ring Method (# of Rings)
Answering Machine Over-Ride
FUNCTION + 6 Download Enable
Reserved
93 Auto Download ID # (Do not Program)
Default
?? I_ _I_ _I
94 Installer Code (Leave this Default Please)
Default
4567 I_4_I_5_I_6_I_7_I
95 User 1 Master Code
Default
1234 I_ _I_ _I_ _I_ _I
96 Dealer Options 1 (Toggle Options ON/OFF)
Default
OFF
ON
OFF
OFF
I_OFF_I
I_OFF_I
I_OFF_I
I_OFF_I
Dealer Code (Panel) Lockout Enable
User Code 1 Lockout
Reserved
Reserved
97 Dealer Options 2 (Toggle Options ON/OFF)
Default
OFF
OFF
OFF
OFF
I_OFF_I
I_OFF_I
I_OFF_I
I_OFF_I
International Dialing Protocol
Invert Bell Output
System Trouble Auto Reset
User 1 Code Program Only
98 Dial Attempts
Default
9 I_9_I (1 to F)