Enter Program 1. Installer Code + FUNCTION (Installer Code is printed on sticker in panel)
2. Press INSTANT until “Activate Program Y/N” or “TURNON PROG Y/N”
3. Press INTERIOR (This enters Easy Menu programming)
4. or press RESET (This enters Advanced programming below)
Exit Program Press RESET twice
Panel can be programmed by Easy Menu for general areas or “Direct Program” for individual areas
INTERIOR moves forwards
INSTANT moves backwards
ON/OFF saves
RESET twice exits
0 = Blanks a location (unless otherwise noted)
* + 0 = 0
* + 1 = B
* + 2 = C
* + 3 = D
* + 4 = E
* + 5 = F
Default Dealer Address 4091 + ON/OFF (Defaults data and system status only)
Default Panel Address 4093 + ON/OFF (Defaults everything)

System Times     (0 = BLANK)

Exit Delay I_3_I_C_I
0000
Common Times
BLANK BLANK = 0 seconds
BLANK F = 15 seconds
1 E = 30 seconds
2 D = 45 seconds
3 C = 60 seconds
5 *0 = 90 seconds
7 8 = 120 seconds
Entry Delay 1 I_1_I_E_I
0001
Entry Delay 2 I_1_I_E_I
0002
Aux Output
Access Timeout
I_0_I_0_I
2402
Abort Delay I_0_I_0_I
2406
Telephone
Line Test Delay
I_0_I_0_I
2414
Sensor Watch
Time (Hrs)
I_0_I_0_I
4088
Report Cancel
Window (sec)
I_0_I_0_I
1179
Chime Time
Time (x1/4 sec)
I_0_I_2_I
2407
AC Fail Report
Delay (min)
I_0_I_6_I
2408
(0 6 = 60 minutes)
Burg Alarm
Timeout (sec)
I_0_I_6_I
2400
Aux Output
Timeout
I_0_I_0_I
2401
Pulse Alarm
Timeout (sec)
I_0_I_6_I
2404
Fire Output
Timeout
I_0_I_6_I
0715
Auto Disarm
Rearm Delay
I_0_I_0_I
4083

Zone Expansion

EZM Group 1
  (Zones 9 to 12)  
I_0_I_?_I
2600
EZM Group 2
  (Zones 13 to 16)  
I_0_I_?_I
2601
EZM Group 3
  (Zones 17 to 20)  
I_0_I_?_I
2602
Left Digit = 0 (Blank)
Right Digit
0 = No EZM
1 = 4-Zone EZM
EZM Group 4
(Zones 21 to 24)
I_0_I_?_I
2603
EZM Group 5
(Zones 25 to 28)
I_0_I_?_I
2604
EZM Group 6
(Zones 29 to 32)
I_0_I_?_I
2605

Central Station Information

CS Receiver Phone 1     (20 digits)     (0 = BLANK and must be 1st digit)

 I_0_I_?_I 
0527
 I_0_I_?_I 
0528
 I_0_I_?_I 
0529
 I_0_I_?_I 
0530
 I_0_I_?_I 
0531
 I_0_I_?_I 
0532
 I_0_I_?_I 
0533
 I_0_I_?_I 
0534
 I_0_I_?_I 
0535
 I_0_I_?_I 
0536
 I_0_I_?_I 
0537
 I_0_I_?_I 
0538
 I_0_I_?_I 
0539
 I_0_I_?_I 
0540
 I_0_I_?_I 
0541
 I_0_I_?_I 
0542
 I_0_I_?_I 
0543
 I_0_I_?_I 
0544
 I_0_I_?_I 
0545
 I_0_I_?_I 
0546
CS Receiver Phone 2     (20 digits)     (0 = BLANK)

 I_0_I_?_I 
0552
 I_0_I_?_I 
0553
 I_0_I_?_I 
0554
 I_0_I_?_I 
0555
 I_0_I_?_I 
0556
 I_0_I_?_I 
0557
 I_0_I_?_I 
0558
 I_0_I_?_I 
0559
 I_0_I_?_I 
0560
 I_0_I_?_I 
0561
 I_0_I_?_I 
0562
 I_0_I_?_I 
0563
 I_0_I_?_I 
0564
 I_0_I_?_I 
0565
 I_0_I_?_I 
0566
 I_0_I_?_I 
0567
 I_0_I_?_I 
0568
 I_0_I_?_I 
0569
 I_0_I_?_I 
0570
 I_0_I_?_I 
0571
CS Receiver Phone 3     (20 digits)     (0 = BLANK)

 I_0_I_?_I 
0577
 I_0_I_?_I 
0578
 I_0_I_?_I 
0579
 I_0_I_?_I 
0580
 I_0_I_?_I 
0581
 I_0_I_?_I 
0582
 I_0_I_?_I 
0583
 I_0_I_?_I 
0584
 I_0_I_?_I 
0585
 I_0_I_?_I 
0586
 I_0_I_?_I 
0587
 I_0_I_?_I 
0588
 I_0_I_?_I 
0589
 I_0_I_?_I 
0590
 I_0_I_?_I 
0591
 I_0_I_?_I 
0592
 I_0_I_?_I 
0593
 I_0_I_?_I 
0594
 I_0_I_?_I 
0595
 I_0_I_?_I 
0596

Area (Partition) 1 Area (Partition) 2
CS Telco 1 Opening/Closing Account Area 1  

 I_0_I_ _I 
0650
 I_0_I_ _I 
0651
 I_0_I_ _I 
0652
 I_0_I_ _I 
0653
CS Telco 1 Opening/Closing Account Area 2

 I_0_I_ _I 
0654
 I_0_I_ _I 
0655
 I_0_I_ _I 
0656
 I_0_I_ _I 
0657
CS Telco 1 Event Account Area 1

 I_0_I_ _I 
0682
 I_0_I_ _I 
0683
 I_0_I_ _I 
0684
 I_0_I_ _I 
0685
CS Telco 1 Event Account Area 2

 I_0_I_ _I 
0686
 I_0_I_ _I 
0687
 I_0_I_ _I 
0688
 I_0_I_ _I 
0689
CS Telco 1 System Event Account Number

 I_0_I_ _I 
0714
 I_0_I_ _I 
0715
 I_0_I_ _I 
0716
 I_0_I_ _I 
0717

Area (Partition) 1 Area (Partition) 2
CS Telco 2 Opening/Closing Account Area 1

 I_0_I_ _I 
0720
 I_0_I_ _I 
0721
 I_0_I_ _I 
0722
 I_0_I_ _I 
0723
CS Telco 2 Opening/Closing Account Area 2

 I_0_I_ _I 
0724
 I_0_I_ _I 
0725
 I_0_I_ _I 
0726
 I_0_I_ _I 
0727
CS Telco 2 Event Account Area 1

 I_0_I_ _I 
0752
 I_0_I_ _I 
0753
 I_0_I_ _I 
0754
 I_0_I_ _I 
0755
CS Telco 2 Event Account Area 2

 I_0_I_ _I 
0756
 I_0_I_ _I 
0757
 I_0_I_ _I 
0758
 I_0_I_ _I 
0759
CS Telco 1 System Event Account Number

 I_0_I_ _I 
0784
 I_0_I_ _I 
0785
 I_0_I_ _I 
0786
 I_0_I_ _I 
0787

Area (Partition) 1 Area (Partition) 2
CS Telco 3 Opening/Closing Account Area 1

I_0_I_ _I
0790
 I_0_I_ _I 
0791
 I_0_I_ _I 
0792
 I_0_I_ _I 
0793
CS Telco 3 Opening/Closing Account Area 2

 I_0_I_ _I 
0794
 I_0_I_ _I 
0795
 I_0_I_ _I 
0796
 I_0_I_ _I 
0797
CS Telco 3 Event Account Area 1

I_0_I_ _I
0822
 I_0_I_ _I 
0823
 I_0_I_ _I 
0824
 I_0_I_ _I 
0825
CS Telco 3 Event Account Area 2

 I_0_I_ _I 
0826
 I_0_I_ _I 
0827
 I_0_I_ _I 
0828
 I_0_I_ _I 
0829
CS Telco 3 System Event Account Number

 I_0_I_ _I 
0854
 I_0_I_ _I 
0855
 I_0_I_ _I 
0856
 I_0_I_ _I 
0857

CS Receiver 1 Format I_0_I_B_I
0525
0 0 = Ademco/Silent Knight Slow (Default)
0 2 = Radionics Fast
0 3 = Silent Knight Fast
0 4 = Radionics, DCI, Franklin Slow
0 5 = Universal High Speed 4/2
0 8 = Radionics BFSK
0 *0 = Radionics Modem 2
0 B = SIA
0 C = Ademco Contact ID
0 D = Ademco Express
0 E = Pager
1 0 = Radionics Modem IIe
CS Receiver 2 Format I_0_I_B_I
0550
CS Receiver 3 Format I_ _I_ _I
0575
0 9 = FBII 4/3/1
Panel Access Code
(Door Strike)
I_ _I_ _I
0490
I_ _I_ _I
0491
I_ _I_ _I
0492
Dealer Security Code
(6-digits)
I_ _I_ _I
0500
I_ _I_ _I
0501
I_ _I_ _I
0502
Global Ambush Code I_9_I_B_I
0495
Communicator Options
    1 = Cancel Test if Report
2 = Disable Wait for Silence
4 = Disable Wait for Handshake
8 = Disable Dial Tone Detect
I_0_I_4_I
1027
1 = Backup Report to Telco 2
2 = TouchTone Dialing Only
4 = TouchTone w/Rotary Backup
8 = Transmit “402” Opening/Closing Code

CS Receiver 1 Options
1 = Sumcheck
2 = 3/1 with Extended Restores
4 = Reserved
8 = Reserved
I_0_I_0_I
0526
1 = 1400Hz Handshake
2 = 2300Hz Handshake
4 = Enable Zone Number w/Pulse Alarms
8 = Single Digit Only

CS Receiver 2 Options
1 = Sumcheck
2 = 3/1 with Extended Restores
4 = Reserved
8 = Reserved
I_0_I_0_I
0527
1 = 1400Hz Handshake
2 = 2300Hz Handshake
4 = Enable Zone Number w/Pulse Alarms
8 = Single Digit Only

CS Receiver 3 Options
1 = Sumcheck
2 = 3/1 with Extended Restores
4 = Reserved
8 = Reserved
I_0_I_0_I
0528
1 = 1400Hz Handshake
2 = 2300Hz Handshake
4 = Enable Zone Number w/Pulse Alarms
8 = Single Digit Only


Downloading Options

Rings Before Answer I_0_I_B_I
4089
Left Digit must be Blank
Right Digit = 1 to 15 (F)
Rings before answer
Callback Telephone Number Select I_0_I_0_I
1022
Auto Download ID Number I_0_I_0_I
1023
Download Security Code (6-digits) I_ _I_ _I
0645
I_ _I_ _I
0646
I_ _I_ _I
0647
Callback Phone Number 1   (20 digits)   (0 = BLANK)
I_ _I_ _I
0600
I_ _I_ _I
0601
I_ _I_ _I
0602
I_ _I_ _I
0603
I_ _I_ _I
0604
I_ _I_ _I
0605
I_ _I_ _I
0606
I_ _I_ _I
0607
I_ _I_ _I
0608
I_ _I_ _I
0609
I_ _I_ _I
0610
I_ _I_ _I
0611
I_ _I_ _I
0612
I_ _I_ _I
0613
I_ _I_ _I
0614
I_ _I_ _I
0615
I_ _I_ _I
0616
I_ _I_ _I
0617
I_ _I_ _I
0618
I_ _I_ _I
0619

Callback Phone Number 2   (20 digits)   (0 = BLANK)
I_ _I_ _I
0625
I_ _I_ _I
0626
I_ _I_ _I
0627
I_ _I_ _I
0628
I_ _I_ _I
0629
I_ _I_ _I
0630
I_ _I_ _I
0631
I_ _I_ _I
0632
I_ _I_ _I
0633
I_ _I_ _I
0634
I_ _I_ _I
0635
I_ _I_ _I
0636
I_ _I_ _I
0637
I_ _I_ _I
0638
I_ _I_ _I
0639
I_ _I_ _I
0640
I_ _I_ _I
0641
I_ _I_ _I
0642
I_ _I_ _I
0643
I_ _I_ _I
0644

Report Codes

Alarm, Restore, Trouble
I_1_I_1_I
0860
Trouble
I_1_I_1_I
0861
Trouble Restore
I_1_I_1_I
0862
Closing
I_0_I_0_I
0864
Conditional Closing
I_0_I_0_I
0865
Opening
>
I_0_I_0_I
0866
Opening After Alarm
I_0_I_0_I
0867
Fail to Close
I_0_I_0_I
0868
Fail to Open
I_0_I_0_I
0869
Test Timer
I_0_I_0_I
0870
Alarm Supervisory
I_0_I_0_I
0871
Bus Failure
I_0_I_0_I
0872
Memory Failure
I_0_I_0_I
0869
Panel Low Battery
I_1_I_1_I
0874
Panel AC Failure
I_1_I_1_I
0875
EZM Tamper
I_0_I_0_I
0876
Sensor Watch
I_0_I_0_I
0877
Reserved
I_0_I_0_I
0878
Reserved
I_0_I_0_I
0879
Telco Line Failure
I_0_I_0_I
0880
Digital Dialer Test
I_1_I_1_I
0890
Reserved
I_0_I_0_I
0891
Reserved
I_0_I_0_I
0892
Service Message
I_0_I_0_I
0893
Program Change
I_0_I_0_I
0894
RF Receiver Trouble
I_0_I_0_I
>
0895
RF Receiver Tamper
I_0_I_0_I
0896
RF Trouble
I_1_I_1_I
0897
Ambush
I_1_I_1_I
0900
Keypad Panic
I_1_I_1_I
0901
Keypad Fire
I_1_I_1_I
0902
Keypad Auxiliary
I_1_I_1_I
0903
Keypad Tamper
I_0_I_0_I
0879
Zone 1
I_3_I_0_I
0910
Zone 2
I_3_I_0_I
0911
Zone 3
I_3_I_0_I
0912
Zone 4
I_3_I_0_I
0913
Zone 5
I_3_I_0_I
0914
Zone 6
I_3_I_0_I
0915
Zone 7
I_3_I_0_I
0916
Zone 8
I_3_I_0_I
0917
Zone 9
I_3_I_0_I
0918
Zone 10
I_3_I_0_I
0919
Zone 11
I_3_I_0_I
0920
Zone 12
I_3_I_0_I
0921
Zone 13
I_3_I_0_I
0922
Zone 14
I_3_I_0_I
0923
Zone 15
I_3_I_0_I
0924
Zone 16
I_3_I_0_I
0925
Contact ID or SIA Codes (enter below for 1st digit, 2nd digit doesn’t matter, blank with 0)
1 = Fire 7 = Gas Alarm
2 = Panic (Audible) 8 = Heat Alarm
3 = Burglary 0 = Auxiliary Alarm
4 = Hold Up (Silent) B = 24 Hour Auxiliary Alarm
Zone 17
I_3_I_0_I
0926
Zone 18
I_3_I_0_I
0927
Zone 19
I_3_I_0_I
0928
Zone 20
I_3_I_0_I
0929
Zone 21
I_3_I_0_I
0930
Zone 22
I_3_I_0_I
0931
Zone 23
I_3_I_0_I
0932
Zone 24
I_3_I_0_I
0933
Zone 25
I_3_I_0_I
0934
Zone 26
I_3_I_0_I
0935
Zone 27
I_3_I_0_I
0936
Zone 28
I_3_I_0_I
0937
Zone 29
I_3_I_0_I
0938
Zone 30
I_3_I_0_I
0939
Zone 31
I_3_I_0_I
0940
Zone 32
I_3_I_0_I
0941

Zone Options

50ms Loop Response I_0_I_0_I
1200
(Zone 1 to 8 Only)
10ms Loop Response I_0_I_0_I
1201
(Zone 1 to 8 Only)
Priority Zone I_0_I_0_I
1202
I_0_I_0_I
1302
I_0_I_0_I
1402
I_0_I_0_I
1502
Priority with Bypass I_0_I_0_I
1203
I_0_I_0_I
1303
I_0_I_0_I
1403
I_0_I_0_I
1503
Auto-Bypass I_0_I_0_I
1204
I_0_I_0_I
1304
I_0_I_0_I
1404
I_0_I_0_I
1504
Selective Bypass I_0_I_0_I
1205
I_0_I_0_I
1305
I_0_I_0_I
1405
I_0_I_0_I
1505
Keyswitch Arming I_0_I_0_I
1206
I_0_I_0_I
1306
I_0_I_0_I
1406
I_0_I_0_I
1506
Auto-Bypass Re-Entry I_0_I_0_I
1207
I_0_I_0_I
1307
I_0_I_0_I
1407
I_0_I_0_I
1507
Pre-Alarm Warning I_0_I_0_I
1208
I_0_I_0_I
1308
I_0_I_0_I
1408
I_0_I_0_I
1508
Never Arm I_0_I_0_I
1209
I_0_I_0_I
1309
I_0_I_0_I
1409
I_0_I_0_I
1509
24-Hour Zone I_0_I_0_I
1210
I_0_I_0_I
1310
I_0_I_0_I
1410
I_0_I_0_I
1510
Burg Alarm Output I_0_I_0_I
1211
I_0_I_0_I
1311
I_0_I_0_I
1411
I_0_I_0_I
1511
Pulsed Alarm Output I_0_I_0_I
1212
I_0_I_0_I
1312
I_0_I_0_I
1412
I_0_I_0_I
1512
Fire Output Lug E9 I_0_I_0_I
1213
I_0_I_0_I
1313
I_0_I_0_I
1413
I_0_I_0_I
1513
Reset Relay I_0_I_0_I
1214
I_0_I_0_I
1314
I_0_I_0_I
1414
I_0_I_0_I
1514
Auxiliary Relay I_0_I_0_I
1215
I_0_I_0_I
1315
I_0_I_0_I
1415
I_0_I_0_I
1515
Entry/Exit 1 I_0_I_0_I
1216
I_0_I_0_I
1316
I_0_I_0_I
1416
I_0_I_0_I
1516
Entry/Exit 2 I_0_I_0_I
1217
I_0_I_0_I
1317
I_0_I_0_I
1417
I_0_I_0_I
1517
Entry/Exit Follower I_0_I_0_I
1218
I_0_I_0_I
1318
I_0_I_0_I
1418
I_0_I_0_I
1518
Auto Reset I_0_I_0_I
1219
I_0_I_0_I
1319
I_0_I_0_I
1419
I_0_I_0_I
1519
Swinger Shutdown I_0_I_0_I
1220
I_0_I_0_I
1320
I_0_I_0_I
1420
I_0_I_0_I
1520
Chime I_0_I_0_I
1221
I_0_I_0_I
1321
I_0_I_0_I
1421
I_0_I_0_I
1521
Abort Delay I_0_I_0_I
1222
I_0_I_0_I
1322
I_0_I_0_I
1422
I_0_I_0_I
1522
Power-Up Delay I_0_I_0_I
1223
I_0_I_0_I
1323
I_0_I_0_I
1423
I_0_I_0_I
1523
Day Zone Open I_0_I_0_I
1224
I_0_I_0_I
1324
I_0_I_0_I
1424
I_0_I_0_I
1524
Day Zone Short I_0_I_0_I
1225
I_0_I_0_I
1325
I_0_I_0_I
1425
I_0_I_0_I
1525
Alarm on Day Zone I_0_I_0_I
1226
I_0_I_0_I
1326
I_0_I_0_I
1426
I_0_I_0_I
1526
Alarm Telco 1 I_0_I_0_I
1227
I_0_I_0_I
1327
I_0_I_0_I
1427
I_0_I_0_I
1527
Alarm Restore Telco 1 I_0_I_0_I
1228
I_0_I_0_I
1328
I_0_I_0_I
1428
I_0_I_0_I
1528
Trouble Telco 1 I_0_I_0_I
1229
I_0_I_0_I
1329
I_0_I_0_I
1429
I_0_I_0_I
1529
Trouble Restore 1 I_0_I_0_I
1230
I_0_I_0_I
1330
I_0_I_0_I
1430
I_0_I_0_I
1530
Alarm Telco 3 I_0_I_0_I
1235
I_0_I_0_I
1335
I_0_I_0_I
1435
I_0_I_0_I
1535
Alarm Restore Telco 3 I_0_I_0_I
1236
I_0_I_0_I
1336
I_0_I_0_I
1436
I_0_I_0_I
1536
Trouble Telco 3 I_0_I_0_I
1237
I_0_I_0_I
1337
I_0_I_0_I
1437
I_0_I_0_I
1537
Trouble Rest Telco 3 I_0_I_0_I
1238
I_0_I_0_I
1338
I_0_I_0_I
1438
I_0_I_0_I
1538
No EOL Resistor I_0_I_0_I
1239
I_0_I_0_I
1339
I_0_I_0_I
1439
I_0_I_0_I
1539
Sensor Watch I_0_I_0_I
1240
I_0_I_0_I
1340
I_0_I_0_I
1440
I_0_I_0_I
1540
Trouble on Open I_0_I_0_I
1241
I_0_I_0_I
1341
I_0_I_0_I
1441
I_0_I_0_I
1541
Trouble on Short I_0_I_0_I
1242
I_0_I_0_I
1342
I_0_I_0_I
1442
I_0_I_0_I
1542
Trouble on Night Open I_0_I_0_I
1243
I_0_I_0_I
1343
I_0_I_0_I
1443
I_0_I_0_I
1543
Zone Area (Partition) 1 I_0_I_0_I
1244
I_0_I_0_I
1344
I_0_I_0_I
1444
I_0_I_0_I
1544
Zone Area (Partition) 2 I_0_I_0_I
1245
I_0_I_0_I
1345
I_0_I_0_I
1445
I_0_I_0_I
1545
2-Wire Smoke Detector I_0_I_0_I
1252
Zone ANDing Group 1 I_0_I_0_I
1254
I_0_I_0_I
1354
I_0_I_0_I
1454
I_0_I_0_I
1554
Zone ANDing Group 2 I_0_I_0_I
1255
I_0_I_0_I
1355
I_0_I_0_I
1455
I_0_I_0_I
1555
Interior Bypass I_0_I_0_I
1262
I_0_I_0_I
1362
I_0_I_0_I
1462
I_0_I_0_I
1562
Keypad Sound on Alarm I_0_I_0_I
1264
I_0_I_0_I
1364
I_0_I_0_I
1464
I_0_I_0_I
1564
Fire Zone I_0_I_0_I
1275
I_0_I_0_I
1375
I_0_I_0_I
1475
I_0_I_0_I
1575
Fire Alarm Verification I_0_I_0_I
1276
I_0_I_0_I
1376
I_0_I_0_I
1476
I_0_I_0_I
1576

Keypad Options     (0 = BLANK)

Keypad 1 Type I_0_I_1_I
0723
Left Digit Right Digit
BLANK (0) = Burg Keypad BLANK (0) = Keypad Disabled
2 = Wizard (Remote module) 1 = Area 1 (Partition 1)
2 = Area 2 (Partition 2)
Keypad 2 Type I_0_I_?_I
0724
Keypad 3 Type I_0_I_?_I
0725
Keypad 4 Type I_0_I_?_I
0726
Keypad 5 Type I_0_I_?_I
0727
Keypad 6 Type I_0_I_?_I
0728
Keypad 7 Type I_0_I_?_I
0729
Keypad 1 1 = Enable Ambush
2 = Easy Arming (Quick Arm)
4 = Panel Access (User Program)
8 = Tour Station
I_7_I_7_I
0730
1 = Keypad Fire Enable
2 = Keypad Medical Enable
4 = Keypad Panic Enable
8 = Remote Access Only

Keypad 2 1 = Enable Ambush
2 = Easy Arming (Quick Arm)
4 = Panel Access (User Program)
8 = Tour Station
I_7_I_7_I
0731
1 = Keypad Fire Enable
2 = Keypad Medical Enable
4 = Keypad Panic Enable
8 = Remote Access Only

Keypad 3 1 = Enable Ambush
2 = Easy Arming (Quick Arm)
4 = Panel Access (User Program)
8 = Tour Station
I_7_I_7_I
0732
1 = Keypad Fire Enable
2 = Keypad Medical Enable
4 = Keypad Panic Enable
8 = Remote Access Only

Keypad 4 1 = Enable Ambush
2 = Easy Arming (Quick Arm)
4 = Panel Access (User Program)
8 = Tour Station
I_7_I_7_I
0733
1 = Keypad Fire Enable
2 = Keypad Medical Enable
4 = Keypad Panic Enable
8 = Remote Access Only

Keypad 5 1 = Enable Ambush
2 = Easy Arming (Quick Arm)
4 = Panel Access (User Program)
8 = Tour Station
I_7_I_7_I
0734
1 = Keypad Fire Enable
2 = Keypad Medical Enable
4 = Keypad Panic Enable
8 = Remote Access Only

Keypad 6 1 = Enable Ambush
2 = Easy Arming (Quick Arm)
4 = Panel Access (User Program)
8 = Tour Station
I_7_I_7_I
0735
1 = Keypad Fire Enable
2 = Keypad Medical Enable
4 = Keypad Panic Enable
8 = Remote Access Only

Keypad 7 1 = Enable Ambush
2 = Easy Arming (Quick Arm)
4 = Panel Access (User Program)
8 = Tour Station
I_7_I_7_I
0736
1 = Keypad Fire Enable
2 = Keypad Medical Enable
4 = Keypad Panic Enable
8 = Remote Access Only


Enable User Code by Area (Partition)

User 01   I_0_I_ _I  
2500
User 17   I_0_I_ _I  
2516
Left Digit must be BLANK (0)
User 02 I_0_I_ _I
2501
User 18 I_0_I_ _I
2517
Right Digit 0 = Not Used
1 = Area 1
2 = Area 2
3 = Area 1 & Area 2
User 03 I_0_I_ _I
2502
User 19 I_0_I_ _I
2518
User 04 I_0_I_ _I
2503
User 20 I_0_I_ _I
2519
User 05 I_0_I_ _I
2504
User 21 I_0_I_ _I
2520
User 06 I_0_I_ _I
2505
User 22 I_0_I_ _I
2521
User 07 I_0_I_ _I
2506
User 23 I_0_I_ _I
2522
User 08 I_0_I_ _I
2507
User 24 I_0_I_ _I
2523
User 09 I_0_I_ _I
2508
User 25 I_0_I_ _I
2524
User 10 I_0_I_ _I
2509
User 26 I_0_I_ _I
2525
User 11 I_0_I_ _I
2510
User 27 I_0_I_ _I
2526
User 12 I_0_I_ _I
2511
User 28 I_0_I_ _I
2527
User 13 I_0_I_ _I
2512
User 29 I_0_I_ _I
2528
User 14 I_0_I_ _I
2513
User 30 I_0_I_ _I
2529
User 15 I_0_I_ _I
2514
User 31 I_0_I_ _I
2530
User 16 I_0_I_ _I
2515
User 32 I_0_I_ _I
2531

Area 1 & 2 System Event/Trouble

Pulsed Alarm Output
    1 = Keypad Tamper
2 = Fail to Open
4 = Fail to Close
8 = Keyfob Low Battery

I_0_I_4_I
Area 1 1120

I_0_I_4_I
Area 2 1130

1 = Ambush
2 = Keypad Panic
4 = Keypad Fire Panic
8 = Keypad Auxiliary Panic
Burg Alarm Output
1 = Keypad Tamper
2 = Fail to Open
4 = Fail to Close
8 = Keyfob Low Battery

I_0_I_4_I
Area 1 1121

I_0_I_4_I
Area 2 1131

1 = Ambush
2 = Keypad Panic
4 = Keypad Fire Panic
8 = Keypad Auxiliary Panic
Fire Output
1 = Keypad Tamper
2 = Fail to Open
4 = Fail to Close
8 = Keyfob Low Battery

I_0_I_4_I
Area 1 1122

I_0_I_4_I
Area 2 1132

1 = Ambush
2 = Keypad Panic
4 = Keypad Fire Panic
8 = Keypad Auxiliary Panic
Reset Relay
1 = Keypad Tamper
2 = Fail to Open
4 = Fail to Close
8 = Keyfob Low Battery

I_0_I_4_I
Area 1 1123

I_0_I_4_I
Area 2 1133

1 = Ambush
2 = Keypad Panic
4 = Keypad Fire Panic
8 = Keypad Auxiliary Panic
Auxiliary Relay
1 = Keypad Tamper
2 = Fail to Open
4 = Fail to Close
8 = Keyfob Low Battery

I_0_I_4_I
Area 1 1124

I_0_I_4_I
Area 2 1134

1 = Ambush
2 = Keypad Panic
4 = Keypad Fire Panic
8 = Keypad Auxiliary Panic
Report Event Telco 1
1 = Keypad Tamper
2 = Fail to Open
4 = Fail to Close
8 = Keyfob Low Battery

I_0_I_4_I
Area 1 1125

I_0_I_4_I
Area 2 1135

1 = Ambush
2 = Keypad Panic
4 = Keypad Fire Panic
8 = Keypad Auxiliary Panic
Report Event Telco 3
1 = Keypad Tamper
2 = Fail to Open
4 = Fail to Close
8 = Keyfob Low Battery

I_0_I_4_I
Area 1 1127

I_0_I_4_I
Area 2 1137

1 = Ambush
2 = Keypad Panic
4 = Keypad Fire Panic
8 = Keypad Auxiliary Panic

CS Area & System Reporting Options

Reserved I_0_I_0_I
2415
1 = Disable Fire Reset Area 1
2 = Disable Fire Reset Area 2
4 = Reserved
8 = Reserved

Reserved I_0_I_0_I
2416
1 = Enable Day Zone Watch Area 1
2 = Enable Day Zone Watch Area 2
4 = Reserved
8 = Reserved

1 = Enable Report PC Preset
2 = Ans Mach P/U w/o Line Seizure
4 = Disable Auto Unbypass on Disarm
8 = Bypass Faulted Zones
I_0_I_0_I
2417
1 = Open Report only after Alarm Report
2 = Close Report on Cond Closing
4 = Inc Sel./Grp Byp in Cond Close Status
8 = Status Report

1 = Access Cont on Aux Out
2 = Enable Burg Out on Entry
4 = Enable Managers Mode
8 = Start Exit Delay after Ringback
I_0_I_0_I
2418
1 = Auto Bell Test on Arming
2 = Auto Reset after Burg Out Timeout
4 = Supress Bypass Reminder if Armed
8 = Reserved

1 = Disable Func. Download
2 = Disable Callback Download
4 = Disable Ans Mach Download
8 = Disable Auto Reset on Day Zn
I_0_I_0_I
2419
1 = Interior 1 Normally Bypassed
2 = Enable Exit Delay Restart
4 = Reset Day Zn with Arm/Disarm only
8 = Enable Local Alarm on 1st “AND” trip

1 = Disable Keypad Instant
2 = Enable Line Fault Test
4 = Disable AC Fail Detection
8 = Telco Fail only when Armed
I_0_I_0_I
2420
1 = Disable Sys Trouble Audible at Keypad
2 = Chime on E4 Lug
4 = Disable Code Req for Func. Mode lvl 1
8 = Disable Code req for Easy Bypass

1 = Don’t clear Aux Relay
2 = Telco Answering Serv Over-Ride
4 = Disable Auto Status
8 = Veri-Phone Zones Trip Fire Out
I_0_I_0_I
2421
1 = Auto Interior Bypass
2 = Veriphone Zones Trip Aux Relay
4 = Veriphone Zones Priority over Alarms
8 = Output Chirp on Keyfob Arm/Disarm

1 = Disable Area Entry Relays
2 = Disable E/E Tone at Keypad
4 = Enable Burg Out for Keyfob Chirp
8 = Enab Burg Out on Telco Fault if Armed
I_0_I_0_I
2422
1 = Fire Output Cadence
2 = Wireless Smoke Low Bat Resound
4 = Supervised Alarm Output
8 = Enable Smoke Detector Dirty Trouble

1 = Reserved
2 = Reserved
4 = Reserved
8 = Disable Auto Dial Tone Detection
I_0_I_0_I
4084
Reserved, must be BLANK (0)


Global System Event/Trouble

Burglary Alarm Output
    1 = Low Battery
2 = AC Failure
4 = EZM Tamper
8 = Sensor Watch
I_0_I_0_I
1082
1 = Test Timer
2 = Alarm Supervision
4 = Comm Bus 1
8 = Memory Failure

Pulsed Burg Output
1 = Low Battery
2 = AC Failure
4 = EZM Tamper
8 = Bell Supervision
I_0_I_0_I
1083
1 = Test Timer
2 = Alarm Supervision
4 = Comm Bus 1
8 = Memory Failure

Fire Output
1 = Low Battery
2 = AC Failure
4 = EZM Tamper
8 = Bell Supervision
I_0_I_0_I
1084
1 = Test Timer
2 = Alarm Supervision
4 = Comm Bus 1
8 = Memory Failure

Reset Relay
1 = Low Battery
2 = AC Failure
4 = EZM Tamper
8 = Bell Supervision
I_0_I_0_I
1085
1 = Test Timer
2 = Alarm Supervision
4 = Comm Bus 1
8 = Memory Failure

Auxiliary Relay
1 = Low Battery
2 = AC Failure
4 = EZM Tamper
8 = Bell Supervision
I_0_I_0_I
1086
1 = Test Timer
2 = Alarm Supervision
4 = Comm Bus 1
8 = Memory Failure

Report Event Telco 1
1 = Low Battery
2 = AC Failure
4 = EZM Tamper
8 = Bell Supervision
I_0_I_0_I
1087
1 = Test Timer
2 = Alarm Supervision
4 = Comm Bus 1
8 = Memory Failure

Report Restore Telco 1
1 = Low Battery
2 = AC Failure
4 = EZM Tamper
8 = Bell Supervision
I_0_I_0_I
1088
1 = Test Timer
2 = Alarm Supervision
4 = Comm Bus 1
8 = Memory Failure

Report Event Telco 3
1 = Low Battery
2 = AC Failure
4 = EZM Tamper
8 = Bell Supervision
I_0_I_0_I
1091
1 = Test Timer
2 = Alarm Supervision
4 = Comm Bus 1
8 = Memory Failure

Report Restore Telco 3
1 = Low Battery
2 = AC Failure
4 = EZM Tamper
8 = Bell Supervision
I_0_I_0_I
1092
1 = Test Timer
2 = Alarm Supervision
4 = Comm Bus 1
8 = Memory Failure


User Reporting Options

User Opening Telco 1 I_0_I_0_I
1030
I_0_I_0_I
1031
I_0_I_0_I
1032
I_0_I_0_I
1033
User Closing Telco 1 I_0_I_0_I
1043
I_0_I_0_I
1044
I_0_I_0_I
1045
I_0_I_0_I
1046
User Opening Telco 3 I_0_I_0_I
1056
I_0_I_0_I
1057
I_0_I_0_I
1058
I_0_I_0_I
1059
User Closing Telco 3 I_0_I_0_I
1069
I_0_I_0_I
1070
I_0_I_0_I
1071
I_0_I_0_I
1072
User Opening Telco 1 I_0_I_0_I
1042
User Opening Telco 3 I_0_I_0_I
1068
User Closing Telco 1 I_0_I_0_I
1055
User Closing Telco 3 I_0_I_0_I
1081

Area Arming Options

Priority Arming Area 1   I_0_I_0_I  
2650
Left Digit must be 0 (Blank)
Right Digit 0 = Disabled 2 = Enabled
Priority Arming Area 2 I_0_I_0_I
2651

RF Receiver & Supervisory Timer Options

Number RF Receivers   I_0_I_0_I  
3776
Digit 1 = must be Blank
Digit 2 = 1 for 1 RF Receiver
2 for 2 RF Receivers