System can be programmed by “Easy Menu” (Click below) or “Advanced” (use below program sheet) |
GEM-RP3DGTL Standard Keypad Addressing/Quick Programming
GEM-RP2ASe2 Fixed English Keypad Addressing/Quick Programming
GEM-RP1CAe2 Alpha Keypad Addressing/Quick Programming
|
Programming of system can only be done by Keypad Address 1 |
Enter Program |
1. Installer Code + FUNCTION (Installer Code is printed on sticker in panel)
2. Press INSTANT until “Activate Program Y/N” or “TURNON PROG Y/N”
3. Press INTERIOR (This enters Easy Menu programming)
4. or press RESET (This enters Advanced programming below)
|
Exit Program |
Press RESET twice |
Panel can be programmed by Easy Menu for general areas or “Direct Program” for individual areas |
|
INTERIOR |
moves forwards |
INSTANT |
moves backwards |
ON/OFF |
saves |
RESET |
twice exits |
0 |
= Blanks a location (unless otherwise noted) |
* + 0 |
= 0 |
* + 1 |
= B |
* + 2 |
= C |
* + 3 |
= D |
* + 4 |
= E |
* + 5 |
= F |
|
Default Dealer |
Address 4091 + ON/OFF (Defaults data and system status only) |
Default Panel |
Address 4093 + ON/OFF (Defaults everything) |
|
|
System Times (0 = BLANK) |
|
Exit Delay |
I_3_I_C_I
0000
|
Common Times |
BLANK BLANK |
= 0 seconds |
BLANK F |
= 15 seconds |
1 E |
= 30 seconds |
2 D |
= 45 seconds |
3 C |
= 60 seconds |
5 *0 |
= 90 seconds |
7 8 |
= 120 seconds |
|
Entry Delay 1 |
I_1_I_E_I
0001
|
Entry Delay 2 |
I_1_I_E_I
0002
|
Aux Output
Access Timeout
|
I_0_I_0_I
2402
|
Abort Delay |
I_0_I_0_I
2406
|
Telephone
Line Test Delay
|
I_0_I_0_I
2414
|
Sensor Watch
Time (Hrs)
|
I_0_I_0_I
4088
|
Report Cancel
Window (sec)
|
I_0_I_0_I
1179
|
Chime Time
Time (x1/4 sec)
|
I_0_I_2_I
2407
|
AC Fail Report
Delay (min)
|
I_0_I_6_I
2408
|
(0 6 = 60 minutes) |
Burg Alarm
Timeout (sec)
|
I_0_I_6_I
2400
|
Aux Output
Timeout
|
I_0_I_0_I
2401
|
Pulse Alarm
Timeout (sec)
|
I_0_I_6_I
2404
|
Fire Output
Timeout
|
I_0_I_6_I
0715
|
Auto Disarm
Rearm Delay
|
I_0_I_0_I
4083
|
|
|
Zone Expansion |
|
EZM Group 1
(Zones 9 to 12)
I_0_I_?_I
2600
|
EZM Group 2
(Zones 13 to 16)
I_0_I_?_I
2601
|
EZM Group 3
(Zones 17 to 20)
I_0_I_?_I
2602
|
Left Digit = 0 (Blank)
Right Digit
0 = No EZM
1 = 4-Zone EZM
|
EZM Group 4
(Zones 21 to 24)
I_0_I_?_I
2603
|
EZM Group 5
(Zones 25 to 28)
I_0_I_?_I
2604
|
EZM Group 6
(Zones 29 to 32)
I_0_I_?_I
2605
|
|
|
Central Station Information |
|
CS Receiver Phone 1 (20 digits) (0 = BLANK and must be 1st digit)
I_0_I_?_I
0527
|
I_0_I_?_I
0528
|
I_0_I_?_I
0529
|
I_0_I_?_I
0530
|
I_0_I_?_I
0531
|
I_0_I_?_I
0532
|
I_0_I_?_I
0533
|
I_0_I_?_I
0534
|
I_0_I_?_I
0535
|
I_0_I_?_I
0536
|
I_0_I_?_I
0537
|
I_0_I_?_I
0538
|
I_0_I_?_I
0539
|
I_0_I_?_I
0540
|
I_0_I_?_I
0541
|
I_0_I_?_I
0542
|
I_0_I_?_I
0543
|
I_0_I_?_I
0544
|
I_0_I_?_I
0545
|
I_0_I_?_I
0546
|
|
CS Receiver Phone 2 (20 digits) (0 = BLANK)
I_0_I_?_I
0552
|
I_0_I_?_I
0553
|
I_0_I_?_I
0554
|
I_0_I_?_I
0555
|
I_0_I_?_I
0556
|
I_0_I_?_I
0557
|
I_0_I_?_I
0558
|
I_0_I_?_I
0559
|
I_0_I_?_I
0560
|
I_0_I_?_I
0561
|
I_0_I_?_I
0562
|
I_0_I_?_I
0563
|
I_0_I_?_I
0564
|
I_0_I_?_I
0565
|
I_0_I_?_I
0566
|
I_0_I_?_I
0567
|
I_0_I_?_I
0568
|
I_0_I_?_I
0569
|
I_0_I_?_I
0570
|
I_0_I_?_I
0571
|
|
CS Receiver Phone 3 (20 digits) (0 = BLANK)
I_0_I_?_I
0577
|
I_0_I_?_I
0578
|
I_0_I_?_I
0579
|
I_0_I_?_I
0580
|
I_0_I_?_I
0581
|
I_0_I_?_I
0582
|
I_0_I_?_I
0583
|
I_0_I_?_I
0584
|
I_0_I_?_I
0585
|
I_0_I_?_I
0586
|
I_0_I_?_I
0587
|
I_0_I_?_I
0588
|
I_0_I_?_I
0589
|
I_0_I_?_I
0590
|
I_0_I_?_I
0591
|
I_0_I_?_I
0592
|
I_0_I_?_I
0593
|
I_0_I_?_I
0594
|
I_0_I_?_I
0595
|
I_0_I_?_I
0596
|
|
Area (Partition) 1 |
Area (Partition) 2 |
CS Telco 1 Opening/Closing Account Area 1
I_0_I_ _I
0650
|
I_0_I_ _I
0651
|
I_0_I_ _I
0652
|
I_0_I_ _I
0653
|
|
CS Telco 1 Opening/Closing Account Area 2
I_0_I_ _I
0654
|
I_0_I_ _I
0655
|
I_0_I_ _I
0656
|
I_0_I_ _I
0657
|
|
CS Telco 1 Event Account Area 1
I_0_I_ _I
0682
|
I_0_I_ _I
0683
|
I_0_I_ _I
0684
|
I_0_I_ _I
0685
|
|
CS Telco 1 Event Account Area 2
I_0_I_ _I
0686
|
I_0_I_ _I
0687
|
I_0_I_ _I
0688
|
I_0_I_ _I
0689
|
|
CS Telco 1 System Event Account Number
I_0_I_ _I
0714
|
I_0_I_ _I
0715
|
I_0_I_ _I
0716
|
I_0_I_ _I
0717
|
|
Area (Partition) 1 |
Area (Partition) 2 |
CS Telco 2 Opening/Closing Account Area 1
I_0_I_ _I
0720
|
I_0_I_ _I
0721
|
I_0_I_ _I
0722
|
I_0_I_ _I
0723
|
|
CS Telco 2 Opening/Closing Account Area 2
I_0_I_ _I
0724
|
I_0_I_ _I
0725
|
I_0_I_ _I
0726
|
I_0_I_ _I
0727
|
|
CS Telco 2 Event Account Area 1
I_0_I_ _I
0752
|
I_0_I_ _I
0753
|
I_0_I_ _I
0754
|
I_0_I_ _I
0755
|
|
CS Telco 2 Event Account Area 2
I_0_I_ _I
0756
|
I_0_I_ _I
0757
|
I_0_I_ _I
0758
|
I_0_I_ _I
0759
|
|
CS Telco 1 System Event Account Number
I_0_I_ _I
0784
|
I_0_I_ _I
0785
|
I_0_I_ _I
0786
|
I_0_I_ _I
0787
|
|
Area (Partition) |
1 Area (Partition) 2 |
CS Telco 3 Opening/Closing Account Area 1
I_0_I_ _I
0790
|
I_0_I_ _I
0791
|
I_0_I_ _I
0792
|
I_0_I_ _I
0793
|
|
CS Telco 3 Opening/Closing Account Area 2
I_0_I_ _I
0794
|
I_0_I_ _I
0795
|
I_0_I_ _I
0796
|
I_0_I_ _I
0797
|
|
CS Telco 3 Event Account Area 1
I_0_I_ _I
0822
|
I_0_I_ _I
0823
|
I_0_I_ _I
0824
|
I_0_I_ _I
0825
|
|
CS Telco 3 Event Account Area 2
I_0_I_ _I
0826
|
I_0_I_ _I
0827
|
I_0_I_ _I
0828
|
I_0_I_ _I
0829
|
|
CS Telco 3 System Event Account Number
I_0_I_ _I
0854
|
I_0_I_ _I
0855
|
I_0_I_ _I
0856
|
I_0_I_ _I
0857
|
|
CS Receiver 1 Format |
I_0_I_B_I
0525
|
0 0 |
= Ademco/Silent Knight Slow (Default) |
0 2 |
= Radionics Fast |
0 3 |
= Silent Knight Fast |
0 4 |
= Radionics, DCI, Franklin Slow |
0 5 |
= Universal High Speed 4/2 |
0 8 |
= Radionics BFSK |
0 *0 |
= Radionics Modem 2 |
0 B |
= SIA |
0 C |
= Ademco Contact ID |
0 D |
= Ademco Express |
0 E |
= Pager |
1 0 |
= Radionics Modem IIe |
|
CS Receiver 2 Format |
I_0_I_B_I
0550
|
CS Receiver 3 Format |
I_ _I_ _I
0575
|
0 9 = FBII 4/3/1 |
Panel Access Code
(Door Strike)
|
I_ _I_ _I
0490
|
I_ _I_ _I
0491
|
I_ _I_ _I
0492
|
Dealer Security Code
(6-digits)
|
I_ _I_ _I
0500
|
I_ _I_ _I
0501
|
I_ _I_ _I
0502
|
Global Ambush Code |
I_9_I_B_I
0495
|
Communicator Options |
|
1 = Cancel Test if Report
2 = Disable Wait for Silence
4 = Disable Wait for Handshake
8 = Disable Dial Tone Detect
|
→ |
I_0_I_4_I
1027
|
← |
1 = Backup Report to Telco 2
2 = TouchTone Dialing Only
4 = TouchTone w/Rotary Backup
8 = Transmit “402” Opening/Closing Code
|
CS Receiver 1 Options |
|
1 = Sumcheck
2 = 3/1 with Extended Restores
4 = Reserved
8 = Reserved
|
→ |
I_0_I_0_I
0526
|
← |
1 = 1400Hz Handshake
2 = 2300Hz Handshake
4 = Enable Zone Number w/Pulse Alarms
8 = Single Digit Only
|
CS Receiver 2 Options |
|
1 = Sumcheck
2 = 3/1 with Extended Restores
4 = Reserved
8 = Reserved
|
→ |
I_0_I_0_I
0527
|
← |
1 = 1400Hz Handshake
2 = 2300Hz Handshake
4 = Enable Zone Number w/Pulse Alarms
8 = Single Digit Only
|
CS Receiver 3 Options |
|
1 = Sumcheck
2 = 3/1 with Extended Restores
4 = Reserved
8 = Reserved
|
→ |
I_0_I_0_I
0528
|
← |
1 = 1400Hz Handshake
2 = 2300Hz Handshake
4 = Enable Zone Number w/Pulse Alarms
8 = Single Digit Only
|
|
|
Downloading Options |
|
Rings Before Answer |
I_0_I_B_I
4089
|
Left Digit must be Blank
Right Digit = 1 to 15 (F)
Rings before answer
|
Callback Telephone Number Select |
I_0_I_0_I
1022
|
Auto Download ID Number |
I_0_I_0_I
1023
|
Download Security Code (6-digits) |
I_ _I_ _I
0645
|
I_ _I_ _I
0646
|
I_ _I_ _I
0647
|
Callback Phone Number 1 (20 digits) (0 = BLANK) |
I_ _I_ _I
0600
|
I_ _I_ _I
0601
|
I_ _I_ _I
0602
|
I_ _I_ _I
0603
|
I_ _I_ _I
0604
|
I_ _I_ _I
0605
|
I_ _I_ _I
0606
|
I_ _I_ _I
0607
|
I_ _I_ _I
0608
|
I_ _I_ _I
0609
|
I_ _I_ _I
0610
|
I_ _I_ _I
0611
|
I_ _I_ _I
0612
|
I_ _I_ _I
0613
|
I_ _I_ _I
0614
|
I_ _I_ _I
0615
|
I_ _I_ _I
0616
|
I_ _I_ _I
0617
|
I_ _I_ _I
0618
|
I_ _I_ _I
0619
|
Callback Phone Number 2 (20 digits) (0 = BLANK) |
I_ _I_ _I
0625
|
I_ _I_ _I
0626
|
I_ _I_ _I
0627
|
I_ _I_ _I
0628
|
I_ _I_ _I
0629
|
I_ _I_ _I
0630
|
I_ _I_ _I
0631
|
I_ _I_ _I
0632
|
I_ _I_ _I
0633
|
I_ _I_ _I
0634
|
I_ _I_ _I
0635
|
I_ _I_ _I
0636
|
I_ _I_ _I
0637
|
I_ _I_ _I
0638
|
I_ _I_ _I
0639
|
I_ _I_ _I
0640
|
I_ _I_ _I
0641
|
I_ _I_ _I
0642
|
I_ _I_ _I
0643
|
I_ _I_ _I
0644
|
|
|
Report Codes |
|
Alarm, Restore, Trouble
I_1_I_1_I
0860
|
Trouble
I_1_I_1_I
0861
|
Trouble Restore
I_1_I_1_I
0862
|
Closing
I_0_I_0_I
0864
|
Conditional Closing
I_0_I_0_I
0865
|
Opening >
I_0_I_0_I
0866
|
Opening After Alarm
I_0_I_0_I
0867
|
Fail to Close
I_0_I_0_I
0868
|
Fail to Open
I_0_I_0_I
0869
|
Test Timer
I_0_I_0_I
0870
|
Alarm Supervisory
I_0_I_0_I
0871
|
Bus Failure
I_0_I_0_I
0872
|
Memory Failure
I_0_I_0_I
0869
|
Panel Low Battery
I_1_I_1_I
0874
|
Panel AC Failure
I_1_I_1_I
0875
|
EZM Tamper
I_0_I_0_I
0876
|
Sensor Watch
I_0_I_0_I
0877
|
Reserved
I_0_I_0_I
0878
|
Reserved
I_0_I_0_I
0879
|
Telco Line Failure
I_0_I_0_I
0880
|
Digital Dialer Test
I_1_I_1_I
0890
|
Reserved
I_0_I_0_I
0891
|
Reserved
I_0_I_0_I
0892
|
Service Message
I_0_I_0_I
0893
|
Program Change
I_0_I_0_I
0894
|
RF Receiver Trouble
I_0_I_0_I >
0895
|
RF Receiver Tamper
I_0_I_0_I
0896
|
RF Trouble
I_1_I_1_I
0897
|
Ambush
I_1_I_1_I
0900
|
Keypad Panic
I_1_I_1_I
0901
|
Keypad Fire
I_1_I_1_I
0902
|
Keypad Auxiliary
I_1_I_1_I
0903
|
Keypad Tamper
I_0_I_0_I
0879
|
Zone 1
I_3_I_0_I
0910
|
Zone 2
I_3_I_0_I
0911
|
Zone 3
I_3_I_0_I
0912
|
Zone 4
I_3_I_0_I
0913
|
Zone 5
I_3_I_0_I
0914
|
Zone 6
I_3_I_0_I
0915
|
Zone 7
I_3_I_0_I
0916
|
Zone 8
I_3_I_0_I
0917
|
Zone 9
I_3_I_0_I
0918
|
Zone 10
I_3_I_0_I
0919
|
Zone 11
I_3_I_0_I
0920
|
Zone 12
I_3_I_0_I
0921
|
Zone 13
I_3_I_0_I
0922
|
Zone 14
I_3_I_0_I
0923
|
Zone 15
I_3_I_0_I
0924
|
Zone 16
I_3_I_0_I
0925
|
Contact ID or SIA Codes (enter below for 1st digit, 2nd digit doesn’t matter, blank with 0) |
1 = Fire |
7 = Gas Alarm |
2 = Panic (Audible) |
8 = Heat Alarm |
3 = Burglary |
0 = Auxiliary Alarm |
4 = Hold Up (Silent) |
B = 24 Hour Auxiliary Alarm |
|
Zone 17
I_3_I_0_I
0926
|
Zone 18
I_3_I_0_I
0927
|
Zone 19
I_3_I_0_I
0928
|
Zone 20
I_3_I_0_I
0929
|
Zone 21
I_3_I_0_I
0930
|
Zone 22
I_3_I_0_I
0931
|
Zone 23
I_3_I_0_I
0932
|
Zone 24
I_3_I_0_I
0933
|
Zone 25
I_3_I_0_I
0934
|
Zone 26
I_3_I_0_I
0935
|
Zone 27
I_3_I_0_I
0936
|
Zone 28
I_3_I_0_I
0937
|
Zone 29
I_3_I_0_I
0938
|
Zone 30
I_3_I_0_I
0939
|
Zone 31
I_3_I_0_I
0940
|
Zone 32
I_3_I_0_I
0941
|
|
|
Zone Options |
|
|
 |
50ms Loop Response |
I_0_I_0_I
1200
|
(Zone 1 to 8 Only) |
10ms Loop Response |
I_0_I_0_I
1201
|
(Zone 1 to 8 Only) |
Priority Zone |
I_0_I_0_I
1202
|
I_0_I_0_I
1302
|
I_0_I_0_I
1402
|
I_0_I_0_I
1502
|
Priority with Bypass |
I_0_I_0_I
1203
|
I_0_I_0_I
1303
|
I_0_I_0_I
1403
|
I_0_I_0_I
1503
|
Auto-Bypass |
I_0_I_0_I
1204
|
I_0_I_0_I
1304
|
I_0_I_0_I
1404
|
I_0_I_0_I
1504
|
Selective Bypass |
I_0_I_0_I
1205
|
I_0_I_0_I
1305
|
I_0_I_0_I
1405
|
I_0_I_0_I
1505
|
Keyswitch Arming |
I_0_I_0_I
1206
|
I_0_I_0_I
1306
|
I_0_I_0_I
1406
|
I_0_I_0_I
1506
|
Auto-Bypass Re-Entry |
I_0_I_0_I
1207
|
I_0_I_0_I
1307
|
I_0_I_0_I
1407
|
I_0_I_0_I
1507
|
Pre-Alarm Warning |
I_0_I_0_I
1208
|
I_0_I_0_I
1308
|
I_0_I_0_I
1408
|
I_0_I_0_I
1508
|
Never Arm |
I_0_I_0_I
1209
|
I_0_I_0_I
1309
|
I_0_I_0_I
1409
|
I_0_I_0_I
1509
|
24-Hour Zone |
I_0_I_0_I
1210
|
I_0_I_0_I
1310
|
I_0_I_0_I
1410
|
I_0_I_0_I
1510
|
Burg Alarm Output |
I_0_I_0_I
1211
|
I_0_I_0_I
1311
|
I_0_I_0_I
1411
|
I_0_I_0_I
1511
|
Pulsed Alarm Output |
I_0_I_0_I
1212
|
I_0_I_0_I
1312
|
I_0_I_0_I
1412
|
I_0_I_0_I
1512
|
Fire Output Lug E9 |
I_0_I_0_I
1213
|
I_0_I_0_I
1313
|
I_0_I_0_I
1413
|
I_0_I_0_I
1513
|
Reset Relay |
I_0_I_0_I
1214
|
I_0_I_0_I
1314
|
I_0_I_0_I
1414
|
I_0_I_0_I
1514
|
Auxiliary Relay |
I_0_I_0_I
1215
|
I_0_I_0_I
1315
|
I_0_I_0_I
1415
|
I_0_I_0_I
1515
|
Entry/Exit 1 |
I_0_I_0_I
1216
|
I_0_I_0_I
1316
|
I_0_I_0_I
1416
|
I_0_I_0_I
1516
|
Entry/Exit 2 |
I_0_I_0_I
1217
|
I_0_I_0_I
1317
|
I_0_I_0_I
1417
|
I_0_I_0_I
1517
|
Entry/Exit Follower |
I_0_I_0_I
1218
|
I_0_I_0_I
1318
|
I_0_I_0_I
1418
|
I_0_I_0_I
1518
|
Auto Reset |
I_0_I_0_I
1219
|
I_0_I_0_I
1319
|
I_0_I_0_I
1419
|
I_0_I_0_I
1519
|
Swinger Shutdown |
I_0_I_0_I
1220
|
I_0_I_0_I
1320
|
I_0_I_0_I
1420
|
I_0_I_0_I
1520
|
Chime |
I_0_I_0_I
1221
|
I_0_I_0_I
1321
|
I_0_I_0_I
1421
|
I_0_I_0_I
1521
|
Abort Delay |
I_0_I_0_I
1222
|
I_0_I_0_I
1322
|
I_0_I_0_I
1422
|
I_0_I_0_I
1522
|
Power-Up Delay |
I_0_I_0_I
1223
|
I_0_I_0_I
1323
|
I_0_I_0_I
1423
|
I_0_I_0_I
1523
|
Day Zone Open |
I_0_I_0_I
1224
|
I_0_I_0_I
1324
|
I_0_I_0_I
1424
|
I_0_I_0_I
1524
|
Day Zone Short |
I_0_I_0_I
1225
|
I_0_I_0_I
1325
|
I_0_I_0_I
1425
|
I_0_I_0_I
1525
|
Alarm on Day Zone |
I_0_I_0_I
1226
|
I_0_I_0_I
1326
|
I_0_I_0_I
1426
|
I_0_I_0_I
1526
|
Alarm Telco 1 |
I_0_I_0_I
1227
|
I_0_I_0_I
1327
|
I_0_I_0_I
1427
|
I_0_I_0_I
1527
|
Alarm Restore Telco 1 |
I_0_I_0_I
1228
|
I_0_I_0_I
1328
|
I_0_I_0_I
1428
|
I_0_I_0_I
1528
|
Trouble Telco 1 |
I_0_I_0_I
1229
|
I_0_I_0_I
1329
|
I_0_I_0_I
1429
|
I_0_I_0_I
1529
|
Trouble Restore 1 |
I_0_I_0_I
1230
|
I_0_I_0_I
1330
|
I_0_I_0_I
1430
|
I_0_I_0_I
1530
|
Alarm Telco 3 |
I_0_I_0_I
1235
|
I_0_I_0_I
1335
|
I_0_I_0_I
1435
|
I_0_I_0_I
1535
|
Alarm Restore Telco 3 |
I_0_I_0_I
1236
|
I_0_I_0_I
1336
|
I_0_I_0_I
1436
|
I_0_I_0_I
1536
|
Trouble Telco 3 |
I_0_I_0_I
1237
|
I_0_I_0_I
1337
|
I_0_I_0_I
1437
|
I_0_I_0_I
1537
|
Trouble Rest Telco 3 |
I_0_I_0_I
1238
|
I_0_I_0_I
1338
|
I_0_I_0_I
1438
|
I_0_I_0_I
1538
|
No EOL Resistor |
I_0_I_0_I
1239
|
I_0_I_0_I
1339
|
I_0_I_0_I
1439
|
I_0_I_0_I
1539
|
Sensor Watch |
I_0_I_0_I
1240
|
I_0_I_0_I
1340
|
I_0_I_0_I
1440
|
I_0_I_0_I
1540
|
Trouble on Open |
I_0_I_0_I
1241
|
I_0_I_0_I
1341
|
I_0_I_0_I
1441
|
I_0_I_0_I
1541
|
Trouble on Short |
I_0_I_0_I
1242
|
I_0_I_0_I
1342
|
I_0_I_0_I
1442
|
I_0_I_0_I
1542
|
Trouble on Night Open |
I_0_I_0_I
1243
|
I_0_I_0_I
1343
|
I_0_I_0_I
1443
|
I_0_I_0_I
1543
|
Zone Area (Partition) 1 |
I_0_I_0_I
1244
|
I_0_I_0_I
1344
|
I_0_I_0_I
1444
|
I_0_I_0_I
1544
|
Zone Area (Partition) 2 |
I_0_I_0_I
1245
|
I_0_I_0_I
1345
|
I_0_I_0_I
1445
|
I_0_I_0_I
1545
|
2-Wire Smoke Detector |
I_0_I_0_I
1252
|
Zone ANDing Group 1 |
I_0_I_0_I
1254
|
I_0_I_0_I
1354
|
I_0_I_0_I
1454
|
I_0_I_0_I
1554
|
Zone ANDing Group 2 |
I_0_I_0_I
1255
|
I_0_I_0_I
1355
|
I_0_I_0_I
1455
|
I_0_I_0_I
1555
|
Interior Bypass |
I_0_I_0_I
1262
|
I_0_I_0_I
1362
|
I_0_I_0_I
1462
|
I_0_I_0_I
1562
|
Keypad Sound on Alarm |
I_0_I_0_I
1264
|
I_0_I_0_I
1364
|
I_0_I_0_I
1464
|
I_0_I_0_I
1564
|
Fire Zone |
I_0_I_0_I
1275
|
I_0_I_0_I
1375
|
I_0_I_0_I
1475
|
I_0_I_0_I
1575
|
Fire Alarm Verification |
I_0_I_0_I
1276
|
I_0_I_0_I
1376
|
I_0_I_0_I
1476
|
I_0_I_0_I
1576
|
|
|
Keypad Options (0 = BLANK) |
|
Keypad 1 Type |
I_0_I_1_I
0723
|
Left Digit |
Right Digit |
BLANK (0) = Burg Keypad |
BLANK (0) = Keypad Disabled |
2 = Wizard (Remote module) |
1 = Area 1 (Partition 1) |
|
2 = Area 2 (Partition 2) |
|
Keypad 2 Type |
I_0_I_?_I
0724
|
Keypad 3 Type |
I_0_I_?_I
0725
|
Keypad 4 Type |
I_0_I_?_I
0726
|
Keypad 5 Type |
I_0_I_?_I
0727
|
Keypad 6 Type |
I_0_I_?_I
0728
|
Keypad 7 Type |
I_0_I_?_I
0729
|
Keypad 1 |
1 = Enable Ambush
2 = Easy Arming (Quick Arm)
4 = Panel Access (User Program)
8 = Tour Station
|
→ |
I_7_I_7_I
0730
|
← |
1 = Keypad Fire Enable
2 = Keypad Medical Enable
4 = Keypad Panic Enable
8 = Remote Access Only
|
Keypad 2 |
1 = Enable Ambush
2 = Easy Arming (Quick Arm)
4 = Panel Access (User Program)
8 = Tour Station
|
→ |
I_7_I_7_I
0731
|
← |
1 = Keypad Fire Enable
2 = Keypad Medical Enable
4 = Keypad Panic Enable
8 = Remote Access Only
|
Keypad 3 |
1 = Enable Ambush
2 = Easy Arming (Quick Arm)
4 = Panel Access (User Program)
8 = Tour Station
|
→ |
I_7_I_7_I
0732
|
← |
1 = Keypad Fire Enable
2 = Keypad Medical Enable
4 = Keypad Panic Enable
8 = Remote Access Only
|
Keypad 4 |
1 = Enable Ambush
2 = Easy Arming (Quick Arm)
4 = Panel Access (User Program)
8 = Tour Station
|
→ |
I_7_I_7_I
0733
|
← |
1 = Keypad Fire Enable
2 = Keypad Medical Enable
4 = Keypad Panic Enable
8 = Remote Access Only
|
Keypad 5 |
1 = Enable Ambush
2 = Easy Arming (Quick Arm)
4 = Panel Access (User Program)
8 = Tour Station
|
→ |
I_7_I_7_I
0734
|
← |
1 = Keypad Fire Enable
2 = Keypad Medical Enable
4 = Keypad Panic Enable
8 = Remote Access Only
|
Keypad 6 |
1 = Enable Ambush
2 = Easy Arming (Quick Arm)
4 = Panel Access (User Program)
8 = Tour Station
|
→ |
I_7_I_7_I
0735
|
← |
1 = Keypad Fire Enable
2 = Keypad Medical Enable
4 = Keypad Panic Enable
8 = Remote Access Only
|
Keypad 7 |
1 = Enable Ambush
2 = Easy Arming (Quick Arm)
4 = Panel Access (User Program)
8 = Tour Station
|
→ |
I_7_I_7_I
0736
|
← |
1 = Keypad Fire Enable
2 = Keypad Medical Enable
4 = Keypad Panic Enable
8 = Remote Access Only
|
|
|
Enable User Code by Area (Partition) |
|
User 01 |
I_0_I_ _I
2500
|
User 17 |
I_0_I_ _I
2516
|
Left Digit must be BLANK (0) |
User 02 |
I_0_I_ _I
2501
|
User 18 |
I_0_I_ _I
2517
|
Right Digit |
0 = Not Used
1 = Area 1
2 = Area 2
3 = Area 1 & Area 2
|
|
User 03 |
I_0_I_ _I
2502
|
User 19 |
I_0_I_ _I
2518
|
User 04 |
I_0_I_ _I
2503
|
User 20 |
I_0_I_ _I
2519
|
User 05 |
I_0_I_ _I
2504
|
User 21 |
I_0_I_ _I
2520
|
User 06 |
I_0_I_ _I
2505
|
User 22 |
I_0_I_ _I
2521
|
User 07 |
I_0_I_ _I
2506
|
User 23 |
I_0_I_ _I
2522
|
User 08 |
I_0_I_ _I
2507
|
User 24 |
I_0_I_ _I
2523
|
User 09 |
I_0_I_ _I
2508
|
User 25 |
I_0_I_ _I
2524
|
User 10 |
I_0_I_ _I
2509
|
User 26 |
I_0_I_ _I
2525
|
User 11 |
I_0_I_ _I
2510
|
User 27 |
I_0_I_ _I
2526
|
User 12 |
I_0_I_ _I
2511
|
User 28 |
I_0_I_ _I
2527
|
User 13 |
I_0_I_ _I
2512
|
User 29 |
I_0_I_ _I
2528
|
User 14 |
I_0_I_ _I
2513
|
User 30 |
I_0_I_ _I
2529
|
User 15 |
I_0_I_ _I
2514
|
User 31 |
I_0_I_ _I
2530
|
User 16 |
I_0_I_ _I
2515
|
User 32 |
I_0_I_ _I
2531
|
|
|
Area 1 & 2 System Event/Trouble |
|
Pulsed Alarm Output |
|
1 = Keypad Tamper
2 = Fail to Open
4 = Fail to Close
8 = Keyfob Low Battery
|
→
→
|
I_0_I_4_I
Area 1 1120
I_0_I_4_I
Area 2 1130
|
←
←
|
1 = Ambush
2 = Keypad Panic
4 = Keypad Fire Panic
8 = Keypad Auxiliary Panic
|
Burg Alarm Output |
|
1 = Keypad Tamper
2 = Fail to Open
4 = Fail to Close
8 = Keyfob Low Battery
|
→
→
|
I_0_I_4_I
Area 1 1121
I_0_I_4_I
Area 2 1131
|
←
←
|
1 = Ambush
2 = Keypad Panic
4 = Keypad Fire Panic
8 = Keypad Auxiliary Panic
|
Fire Output |
|
1 = Keypad Tamper
2 = Fail to Open
4 = Fail to Close
8 = Keyfob Low Battery
|
→
→
|
I_0_I_4_I
Area 1 1122
I_0_I_4_I
Area 2 1132
|
←
←
|
1 = Ambush
2 = Keypad Panic
4 = Keypad Fire Panic
8 = Keypad Auxiliary Panic
|
Reset Relay |
|
1 = Keypad Tamper
2 = Fail to Open
4 = Fail to Close
8 = Keyfob Low Battery
|
→
→
|
I_0_I_4_I
Area 1 1123
I_0_I_4_I
Area 2 1133
|
←
←
|
1 = Ambush
2 = Keypad Panic
4 = Keypad Fire Panic
8 = Keypad Auxiliary Panic
|
Auxiliary Relay |
|
1 = Keypad Tamper
2 = Fail to Open
4 = Fail to Close
8 = Keyfob Low Battery
|
→
→
|
I_0_I_4_I
Area 1 1124
I_0_I_4_I
Area 2 1134
|
←
←
|
1 = Ambush
2 = Keypad Panic
4 = Keypad Fire Panic
8 = Keypad Auxiliary Panic
|
Report Event Telco 1 |
|
1 = Keypad Tamper
2 = Fail to Open
4 = Fail to Close
8 = Keyfob Low Battery
|
→
→
|
I_0_I_4_I
Area 1 1125
I_0_I_4_I
Area 2 1135
|
←
←
|
1 = Ambush
2 = Keypad Panic
4 = Keypad Fire Panic
8 = Keypad Auxiliary Panic
|
Report Event Telco 3 |
|
1 = Keypad Tamper
2 = Fail to Open
4 = Fail to Close
8 = Keyfob Low Battery
|
→
→
|
I_0_I_4_I
Area 1 1127
I_0_I_4_I
Area 2 1137
|
←
←
|
1 = Ambush
2 = Keypad Panic
4 = Keypad Fire Panic
8 = Keypad Auxiliary Panic
|
|
|
CS Area & System Reporting Options |
|
Reserved |
→ |
I_0_I_0_I
2415
|
← |
1 = Disable Fire Reset Area 1
2 = Disable Fire Reset Area 2
4 = Reserved
8 = Reserved
|
Reserved |
→ |
I_0_I_0_I
2416
|
← |
1 = Enable Day Zone Watch Area 1
2 = Enable Day Zone Watch Area 2
4 = Reserved
8 = Reserved
|
1 = Enable Report PC Preset
2 = Ans Mach P/U w/o Line Seizure
4 = Disable Auto Unbypass on Disarm
8 = Bypass Faulted Zones
|
→ |
I_0_I_0_I
2417
|
← |
1 = Open Report only after Alarm Report
2 = Close Report on Cond Closing
4 = Inc Sel./Grp Byp in Cond Close Status
8 = Status Report
|
1 = Access Cont on Aux Out
2 = Enable Burg Out on Entry
4 = Enable Managers Mode
8 = Start Exit Delay after Ringback
|
→ |
I_0_I_0_I
2418
|
← |
1 = Auto Bell Test on Arming
2 = Auto Reset after Burg Out Timeout
4 = Supress Bypass Reminder if Armed
8 = Reserved
|
1 = Disable Func. Download
2 = Disable Callback Download
4 = Disable Ans Mach Download
8 = Disable Auto Reset on Day Zn
|
→ |
I_0_I_0_I
2419
|
← |
1 = Interior 1 Normally Bypassed
2 = Enable Exit Delay Restart
4 = Reset Day Zn with Arm/Disarm only
8 = Enable Local Alarm on 1st “AND” trip
|
1 = Disable Keypad Instant
2 = Enable Line Fault Test
4 = Disable AC Fail Detection
8 = Telco Fail only when Armed
|
→ |
I_0_I_0_I
2420
|
← |
1 = Disable Sys Trouble Audible at Keypad
2 = Chime on E4 Lug
4 = Disable Code Req for Func. Mode lvl 1
8 = Disable Code req for Easy Bypass
|
1 = Don’t clear Aux Relay
2 = Telco Answering Serv Over-Ride
4 = Disable Auto Status
8 = Veri-Phone Zones Trip Fire Out
|
→ |
I_0_I_0_I
2421
|
← |
1 = Auto Interior Bypass
2 = Veriphone Zones Trip Aux Relay
4 = Veriphone Zones Priority over Alarms
8 = Output Chirp on Keyfob Arm/Disarm
|
1 = Disable Area Entry Relays
2 = Disable E/E Tone at Keypad
4 = Enable Burg Out for Keyfob Chirp
8 = Enab Burg Out on Telco Fault if Armed
|
→ |
I_0_I_0_I
2422
|
← |
1 = Fire Output Cadence
2 = Wireless Smoke Low Bat Resound
4 = Supervised Alarm Output
8 = Enable Smoke Detector Dirty Trouble
|
1 = Reserved
2 = Reserved
4 = Reserved
8 = Disable Auto Dial Tone Detection
|
→ |
I_0_I_0_I
4084
|
← |
Reserved, must be BLANK (0)
|
|
|
Global System Event/Trouble |
|
Burglary Alarm Output |
|
1 = Low Battery
2 = AC Failure
4 = EZM Tamper
8 = Sensor Watch
|
→ |
I_0_I_0_I
1082
|
← |
1 = Test Timer
2 = Alarm Supervision
4 = Comm Bus 1
8 = Memory Failure
|
Pulsed Burg Output |
|
1 = Low Battery
2 = AC Failure
4 = EZM Tamper
8 = Bell Supervision
|
→ |
I_0_I_0_I
1083
|
← |
1 = Test Timer
2 = Alarm Supervision
4 = Comm Bus 1
8 = Memory Failure
|
Fire Output |
|
1 = Low Battery
2 = AC Failure
4 = EZM Tamper
8 = Bell Supervision
|
→ |
I_0_I_0_I
1084
|
← |
1 = Test Timer
2 = Alarm Supervision
4 = Comm Bus 1
8 = Memory Failure
|
Reset Relay |
|
1 = Low Battery
2 = AC Failure
4 = EZM Tamper
8 = Bell Supervision
|
→ |
I_0_I_0_I
1085
|
← |
1 = Test Timer
2 = Alarm Supervision
4 = Comm Bus 1
8 = Memory Failure
|
Auxiliary Relay |
|
1 = Low Battery
2 = AC Failure
4 = EZM Tamper
8 = Bell Supervision
|
→ |
I_0_I_0_I
1086
|
← |
1 = Test Timer
2 = Alarm Supervision
4 = Comm Bus 1
8 = Memory Failure
|
Report Event Telco 1 |
|
1 = Low Battery
2 = AC Failure
4 = EZM Tamper
8 = Bell Supervision
|
→ |
I_0_I_0_I
1087
|
← |
1 = Test Timer
2 = Alarm Supervision
4 = Comm Bus 1
8 = Memory Failure
|
Report Restore Telco 1 |
|
1 = Low Battery
2 = AC Failure
4 = EZM Tamper
8 = Bell Supervision
|
→ |
I_0_I_0_I
1088
|
← |
1 = Test Timer
2 = Alarm Supervision
4 = Comm Bus 1
8 = Memory Failure
|
Report Event Telco 3 |
|
1 = Low Battery
2 = AC Failure
4 = EZM Tamper
8 = Bell Supervision
|
→ |
I_0_I_0_I
1091
|
← |
1 = Test Timer
2 = Alarm Supervision
4 = Comm Bus 1
8 = Memory Failure
|
Report Restore Telco 3 |
|
1 = Low Battery
2 = AC Failure
4 = EZM Tamper
8 = Bell Supervision
|
→ |
I_0_I_0_I
1092
|
← |
1 = Test Timer
2 = Alarm Supervision
4 = Comm Bus 1
8 = Memory Failure
|
|
|
User Reporting Options |
|
|
 |
User Opening Telco 1 |
I_0_I_0_I
1030
|
I_0_I_0_I
1031
|
I_0_I_0_I
1032
|
I_0_I_0_I
1033
|
User Closing Telco 1 |
I_0_I_0_I
1043
|
I_0_I_0_I
1044
|
I_0_I_0_I
1045
|
I_0_I_0_I
1046
|
User Opening Telco 3 |
I_0_I_0_I
1056
|
I_0_I_0_I
1057
|
I_0_I_0_I
1058
|
I_0_I_0_I
1059
|
User Closing Telco 3 |
I_0_I_0_I
1069
|
I_0_I_0_I
1070
|
I_0_I_0_I
1071
|
I_0_I_0_I
1072
|
|
|
|
 |
User Opening Telco 1 |
I_0_I_0_I
1042
|
User Opening Telco 3 |
I_0_I_0_I
1068
|
User Closing Telco 1 |
I_0_I_0_I
1055
|
User Closing Telco 3 |
I_0_I_0_I
1081
|
|
|
Area Arming Options |
|
Priority Arming Area 1 |
I_0_I_0_I
2650
|
Left Digit must be 0 (Blank)
Right Digit 0 = Disabled 2 = Enabled
|
Priority Arming Area 2 |
I_0_I_0_I
2651
|
|
|
RF Receiver & Supervisory Timer Options |
|
Number RF Receivers |
I_0_I_0_I
3776
|
Digit 1 |
= |
must be Blank |
Digit 2 |
= |
1 for 1 RF Receiver
2 for 2 RF Receivers
|
|
|