Napco P1632 Program

System can be programmed by “Easy Menu” (Click below) or “Advanced” (use below program sheet)
GEM-RP3DGTL Standard Keypad Addressing/Quick Programming

GEM-RP2ASe2 Fixed English Keypad Addressing/Quick Programming

GEM-RP1CAe2 Alpha Keypad Addressing/Quick Programming

Programming of system can only be done by Keypad Address 1
Enter Program 1. 456789 + FUNCTION
2. Press INSTANT until “Activate Program Y/N” or “TURNON PROG Y/N”
3. Press INTERIOR to enter “Easy Menu” Programming
4. or press RESET to enter “Advanced” Programming (see below)
Go to Location 1. Enter 4-digit location (Current value displays)
2. FUNCTION toggles 4-digit location and 2-digit data
3. Enter new data (New value displays)
0 Blanks out a location
4. Press ON/OFF to save (Cursor moves back to 4-digit Location)
5. Press * + INTERIOR for next location or enter new 4-digit location
Exit Program Press RESET twice
Hex Program * + 0 = 0
* + 1 = B
* + 2 = C
* + 3 = D
* + 4 = E
* + 5 = F
Default Dealer
Programming
Address 1197 + ON/OFF (Defaults data and system status only)
(Saves Zone Descriptions & Schedules)
Default Panel Address 1198 + ON/OFF (Defaults everything)

System Times     (0 = BLANK)

Exit Delay I_3_I_C_I
0000

Common Times
BLANK BLANK = 0 seconds
BLANK F = 15 seconds
1 E = 30 seconds
2 D = 45 seconds
5 *0 = 90 seconds
7 8 = 120 seconds
3 C = 60 seconds
Entry Delay 1 I_1_I_E_I
0001

Entry Delay 2 I_1_I_E_I
0002

PGM2 Output
Timeout (sec)
  I_0_I_0_I  
0710
PGM2 Access
Control Timeout
  I_0_I_0_I  
0711

Alarm Output
Timeout (sec)
I_1_I_0_I
0712
Pulse Alarm
Output Timeout
I_1_I_0_I
0713

PGM1 Output
Timeout (sec)
I_1_I_0_I
0714
Abort Delay
(sec)
I_0_I_0_I
0715

Sensor Watch
Time (Hrs)
I_0_I_0_I
1059
Report Cancel
Window (sec)
I_0_I_0_I
1179

Chime Time
Time (x1/4 sec)
I_0_I_2_I
0716
AC Fail Report
Delay (min)
I_3_I_7_I
0717

(3 7 = 60 minutes)

Zone Expansion

EZM Group 1
  (Zones 9 to 12)  
I_0_I_?_I
0737
EZM Group 2
(Zones 13 to 16)
  I_0_I_?_I  
0738
EZM Group 3
  (Zones 17 to 20)  
I_0_I_?_I
0739
EZM Group 4
(Zones 21 to 24)
I_0_I_?_I
0740
EZM Group 5
(Zones 25 to 28)
I_0_I_?_I
0741
EZM Group 6
(Zones 29 to 32)
I_0_I_?_I
0742
(Enable if using EZM Module or Keypad Zones)

BLANK = No EZM present
1 = 4-Zone EZM
an 8-Zone EZM counts as 2 EZM Groups

Central Station Information

CS Receiver Phone 1     (20 digits)     (0 = BLANK and must be 1st digit)

  I_0_I_?_I  
0172
  I_0_I_?_I  
0173
  I_0_I_?_I  
0174
  I_0_I_?_I  
0175
  I_0_I_?_I  
0176
  I_0_I_?_I  
0177
  I_0_I_?_I  
0178
  I_0_I_?_I  
0179
  I_0_I_?_I  
0180
  I_0_I_?_I  
0181
  I_0_I_?_I  
0182
  I_0_I_?_I  
0183
  I_0_I_?_I  
0184
  I_0_I_?_I  
0185
  I_0_I_?_I  
0186
  I_0_I_?_I  
0187
  I_0_I_?_I  
0188
  I_0_I_?_I  
0189
  I_0_I_?_I  
0190
  I_0_I_?_I  
0191
CS Receiver Phone 2     (20 digits)     (0 = BLANK)

  I_0_I_?_I  
0194
  I_0_I_?_I  
0195
  I_0_I_?_I  
0196
  I_0_I_?_I  
0197
  I_0_I_?_I  
0198
  I_0_I_?_I  
0199
  I_0_I_?_I  
0200
  I_0_I_?_I  
0201
  I_0_I_?_I  
0202
  I_0_I_?_I  
0203
  I_0_I_?_I  
0204
  I_0_I_?_I  
0205
  I_0_I_?_I  
0206
  I_0_I_?_I  
0207
  I_0_I_?_I  
0208
  I_0_I_?_I  
0209
  I_0_I_?_I  
0210
  I_0_I_?_I  
0211
  I_0_I_?_I  
0212
  I_0_I_?_I  
0213
CS Receiver Phone 3     (20 digits)     (0 = BLANK)

  I_0_I_?_I  
0216
  I_0_I_?_I  
0217
  I_0_I_?_I  
0218
  I_0_I_?_I  
0219
  I_0_I_?_I  
0220
  I_0_I_?_I  
0221
  I_0_I_?_I  
0222
  I_0_I_?_I  
0223
  I_0_I_?_I  
0224
  I_0_I_?_I  
0225
  I_0_I_?_I  
0226
  I_0_I_?_I  
0227
  I_0_I_?_I  
0228
  I_0_I_?_I  
0229
  I_0_I_?_I  
0230
  I_0_I_?_I  
0231
  I_0_I_?_I  
0232
  I_0_I_?_I  
0233
  I_0_I_?_I  
0234
  I_0_I_?_I  
0235
CS Telco 1 Opening/Closing Account Number (Use only if sending Opening/Closings, 0 = BLANK)

  I_0_I_?_I  
0259
  I_0_I_?_I  
0260
  I_0_I_?_I  
0261
  I_0_I_?_I  
0262
CS Telco 1 Event Account Number (Use this for Account Number, 0 = BLANK)

  I_0_I_?_I  
0267
  I_0_I_?_I  
0268
  I_0_I_?_I  
0269
  I_0_I_?_I  
0270
CS Telco 1 System Event Account Number (Use this for Account Number, 0 = BLANK)

  I_0_I_?_I  
0275
  I_0_I_?_I  
0276
  I_0_I_?_I  
0277
  I_0_I_?_I  
0278
CS Telco 2 Opening/Closing Account Number     (0 = BLANK)

  I_0_I_?_I  
0279
  I_0_I_?_I  
0280
  I_0_I_?_I  
0281
  I_0_I_?_I  
0282
CS Telco 2 Event Account Number     (0 = BLANK)

  I_0_I_?_I  
0287
  I_0_I_?_I  
0288
  I_0_I_?_I  
0289
  I_0_I_?_I  
0290
CS Telco 2 System Event Account Number     (0 = BLANK)

  I_0_I_?_I  
0295
  I_0_I_?_I  
0296
  I_0_I_?_I  
0297
  I_0_I_?_I  
0298
CS Telco 3 Opening/Closing Account Number     (0 = BLANK)

  I_0_I_?_I  
0299
  I_0_I_?_I  
0300
  I_0_I_?_I  
0301
  I_0_I_?_I  
0302
CS Telco 3 Event Account Number     (0 = BLANK)

  I_0_I_?_I  
0307
  I_0_I_?_I  
0308
  I_0_I_?_I  
0309
  I_0_I_?_I  
0310
CS Telco 3 System Event Account Number     (0 = BLANK)

  I_0_I_?_I  
0315
  I_0_I_?_I  
0316
  I_0_I_?_I  
0317
  I_0_I_?_I  
0318
CS Receiver 1 Format I_0_I_C_I
0170
BLANK = Ademco/Silent Knight Slow (Default)
2 = Radionics Fast
3 = Silent Knight Fast
4 = Radionics, DCI, Franklin Slow
5 = Universal High Speed 4/2
B = SIA
C = Ademco Point ID (Contact ID)
E = Pager
(Use SIA or Contact ID, do NOT use 4/2)
CS Receiver 2 Format I_0_I_C_I
0192
CS Receiver 3 Format I_0_I_C_I
0214
Global Ambush Code I_9_I_9_I
1054
Communicator Options
      1 = Cancel Test if Report
2 = Disable Wait for Silence
4 = Disable Wait for Handshake
08 = Disable Dial Tone Detect
I_0_I_4_I
0394
1 = Backup Report to Telco 2
2 = TouchTone Dialing Only
4 = TouchTone w/Rotary Backup
8 = Reserved

CS Receiver 1 Options
1 = Sumcheck
2 = 3/1 with Extended Restores
4 = Reserved
8 = Reserved
I_0_I_0_I
0171
1 = 1400Hz Handshake
2 = 2300Hz Handshake
4 = Enable Zone Number w/Pulse Alarms
8 = Single Digit Only

CS Receiver 2 Options
1 = Sumcheck
2 = 3/1 with Extended Restores
4 = Reserved
8 = Reserved
I_0_I_0_I
0193
1 = 1400Hz Handshake
2 = 2300Hz Handshake
4 = Enable Zone Number w/Pulse Alarms
8 = Single Digit Only

CS Receiver 3 Options
1 = Sumcheck
2 = 3/1 with Extended Restores
4 = Reserved
8 = Reserved
I_0_I_0_I
0215
1 = 1400Hz Handshake
2 = 2300Hz Handshake
4 = Enable Zone Number w/Pulse Alarms
8 = Single Digit Only

Downloading Options

Rings Before Answer I_0_I_9_I
1183
Left Digit must be Blank
Right Digit = 1 to 15 (F) Rings before answer
Callback Phone Number     (20 digits)     (0 = BLANK)
I_ _I_ _I
0236
I_ _I_ _I
0237
I_ _I_ _I
0238
I_ _I_ _I
0239
I_ _I_ _I
0240
I_ _I_ _I
0241
I_ _I_ _I
0242
I_ _I_ _I
0243
I_ _I_ _I
0244
I_ _I_ _I
0245
I_ _I_ _I
0246
I_ _I_ _I
0247
I_ _I_ _I
0248
I_ _I_ _I
0249
I_ _I_ _I
0250
I_ _I_ _I
0251
I_ _I_ _I
0252
I_ _I_ _I
0253
I_ _I_ _I
0254
I_ _I_ _I
0255

Report Codes

Alarm, Restore, Trouble I_1_I_1_I
0319
RF Receiver Trouble I_0_I_0_I
0334
Trouble I_1_I_1_I
0320
Memory Failure I_1_I_1_I
0335
Trouble Restore I_1_I_1_I
0321
Panel Low Battery I_1_I_1_I
0336
Xmitter Low Battery I_0_I_0_I
0322
Panel AC Failure I_1_I_1_I
0337
Xmitter Supervision I_0_I_0_I
0323
EZM Expander Tamper I_1_I_1_I
0338
Xmitter Tamper I_1_I_1_I
0324
Alarm Output Supervision I_1_I_1_I
0339
For Future Use I_0_I_0_I
0325
Ambush/Duress I_1_I_1_I
0340
Opening I_0_I_0_I
0326
Police Panic I_1_I_1_I
0341
Closing I_0_I_0_I
0327
Fire Panic I_1_I_1_I
0342
Opening After Alarm I_1_I_1_I
0328
Auxiliary (General) Panic I_1_I_1_I
0343
Conditional Close I_1_I_1_I
0329
Tamper I_1_I_1_I
0344
Cancel I_1_I_1_I
0330
Fail to Open I_0_I_0_I
0345
Test Timer I_1_I_1_I
0332
Fail to Close I_0_I_0_I
0346
Telco Failure I_0_I_1_I
0333
Keyfob Low Battery I_0_I_0_I
0347

Zone 1
I_3_I_0_I
0358
Zone 2
I_3_I_0_I
0359
Zone 3
I_3_I_0_I
0360
Zone 4
I_3_I_0_I
0361
Zone 5
I_3_I_0_I
0362
Zone 6
I_3_I_0_I
0363
Zone 7
I_3_I_0_I
0364
Zone 8
I_3_I_0_I
0365
Zone 9
I_3_I_0_I
0366
Zone 10
I_3_I_0_I
0367
Zone 11
I_3_I_0_I
0368
Zone 12
I_3_I_0_I
0369
Zone 13
I_3_I_0_I
0370
Zone 14
I_3_I_0_I
0371
Zone 15
I_3_I_0_I
0372
Zone 16
I_3_I_0_I
0373
Contact ID or SIA Codes (enter below for 1st digit, 2nd digit doesn’t matter, blank with 0)

1 = Fire 7 = Gas Alarm
2 = Panic (Audible) 8 = Heat Alarm
3 = Burglary 0 = Auxiliary Alarm
4 = Hold Up (Silent) B = 24 Hour Auxiliary Alarm
Zone 17
I_3_I_0_I
0358
Zone 18
I_3_I_0_I
0359
Zone 19
I_3_I_0_I
0360
Zone 20
I_3_I_0_I
0361
Zone 21
I_3_I_0_I
0362
Zone 22
I_3_I_0_I
0363
Zone 23
I_3_I_0_I
0364
Zone 24
I_3_I_0_I
0365
Zone 25
I_3_I_0_I
0366
Zone 26
I_3_I_0_I
0367
Zone 27
I_3_I_0_I
0368
Zone 28
I_3_I_0_I
0369
Zone 29
I_3_I_0_I
0370
Zone 30
I_3_I_0_I
0371
Zone 31
I_3_I_0_I
0372
Zone 32
I_3_I_0_I
0373

Zone Options

50ms Loop Response
(Zone 1 to 8 Only)
I_0_I_0_I
0490
Priority Zone I_0_I_0_I
0491
I_0_I_0_I
0546
I_0_I_0_I
0601
I_0_I_0_I
0656
Priority with Bypass I_0_I_0_I
0492
I_0_I_0_I
0547
I_0_I_0_I
0602
I_0_I_0_I
0657
Auto-Bypass I_0_I_0_I
0493
I_0_I_0_I
0548
I_0_I_0_I
0603
I_0_I_0_I
0658
Selective Bypass I_0_I_0_I
0494
I_0_I_0_I
0549
I_0_I_0_I
0604
I_0_I_0_I
0659
Keyswitch Arming I_0_I_0_I
0495
I_0_I_0_I
0550
I_0_I_0_I
0605
I_0_I_0_I
0660
Auto-Bypass Re-Entry I_0_I_0_I
0496
I_0_I_0_I
0551
I_0_I_0_I
0606
I_0_I_0_I
0661
Pre-Alarm Warning I_0_I_0_I
0497
I_0_I_0_I
0552
I_0_I_0_I
0607
I_0_I_0_I
0662
Never Arm I_0_I_0_I
0498
I_0_I_0_I
0553
I_0_I_0_I
0608
I_0_I_0_I
0663
24-Hour Zone
(Fire & Panics)
I_0_I_0_I
0499
I_0_I_0_I
0554
I_0_I_0_I
0609
I_0_I_0_I
0664
Alarm Output I_0_I_0_I
0500
I_0_I_0_I
0555
I_0_I_0_I
0610
I_0_I_0_I
0665
Pulsed Alarm Output I_0_I_0_I
0501
I_0_I_0_I
0556
I_0_I_0_I
0611
I_0_I_0_I
0666
PGM1 Output I_0_I_0_I
0502
I_0_I_0_I
0557
I_0_I_0_I
0612
I_0_I_0_I
0667
PGM2 Output I_0_I_0_I
0503
I_0_I_0_I
0558
I_0_I_0_I
0613
I_0_I_0_I
0668
Entry/Exit 1 I_0_I_0_I
0504
I_0_I_0_I
0559
I_0_I_0_I
0614
I_0_I_0_I
0669
Entry/Exit 2 I_0_I_0_I
0505
I_0_I_0_I
0560
I_0_I_0_I
0615
I_0_I_0_I
0670
Entry/Exit Follower I_0_I_0_I
0506
I_0_I_0_I
0561
I_0_I_0_I
0616
I_0_I_0_I
0671
Auto Reset I_0_I_0_I
0507
I_0_I_0_I
0562
I_0_I_0_I
0617
I_0_I_0_I
0672
Swinger Shutdown I_0_I_0_I
0508
I_0_I_0_I
0563
I_0_I_0_I
0618
I_0_I_0_I
0673
Chime I_0_I_0_I
0509
I_0_I_0_I
0564
I_0_I_0_I
0619
I_0_I_0_I
0674
Abort Delay I_0_I_0_I
0510
I_0_I_0_I
0565
I_0_I_0_I
0620
I_0_I_0_I
0675
Power-Up Delay I_0_I_0_I
0511
I_0_I_0_I
0566
I_0_I_0_I
0621
I_0_I_0_I
0676
Day Zone Open I_0_I_0_I
0512
I_0_I_0_I
0567
I_0_I_0_I
0622
I_0_I_0_I
0677
Day Zone Short I_0_I_0_I
0513
I_0_I_0_I
0568
I_0_I_0_I
0623
I_0_I_0_I
0678
Alarm on Day Zone I_0_I_0_I
0514
I_0_I_0_I
0569
I_0_I_0_I
0624
I_0_I_0_I
0679
Alarm Telco 1 I_0_I_0_I
0515
I_0_I_0_I
0570
I_0_I_0_I
0625
I_0_I_0_I
0680
Alarm Restore Telco 1 I_0_I_0_I
0516
I_0_I_0_I
0571
I_0_I_0_I
0626
I_0_I_0_I
0681
Trouble Telco 1 I_0_I_0_I
0517
I_0_I_0_I
0572
I_0_I_0_I
0627
I_0_I_0_I
0682
Trouble Restore 1 I_0_I_0_I
0518
I_0_I_0_I
0573
I_0_I_0_I
0628
I_0_I_0_I
0683
Alarm Telco 3 I_0_I_0_I
0519
I_0_I_0_I
0574
I_0_I_0_I
0629
I_0_I_0_I
0684
Alarm Restore Telco 3 I_0_I_0_I
0520
I_0_I_0_I
0575
I_0_I_0_I
0630
I_0_I_0_I
0685
Trouble Telco 3 I_0_I_0_I
0521
I_0_I_0_I
0576
I_0_I_0_I
0631
I_0_I_0_I
0686
Trouble Rest Telco 3 I_0_I_0_I
0522
I_0_I_0_I
0577
I_0_I_0_I
>
0632
I_0_I_0_I
0687
No EOL Resistor I_0_I_0_I
0523
I_0_I_0_I
0578
I_0_I_0_I
0633
I_0_I_0_I
0688
Trouble on Open I_0_I_0_I
0524
I_0_I_0_I
0579
I_0_I_0_I
0634
I_0_I_0_I
0689
Trouble on Short I_0_I_0_I
0525
I_0_I_0_I
0580
I_0_I_0_I
0635
I_0_I_0_I
0690
Zone Area 1 I_0_I_0_I
0526
I_0_I_0_I
0581
I_0_I_0_I
0636
I_0_I_0_I
0691
Zone Area 2 I_0_I_0_I
0527
I_0_I_0_I
0582
I_0_I_0_I
0637
I_0_I_0_I
0692
Reserved Future Use I_0_I_0_I
0528
I_0_I_0_I
0583
I_0_I_0_I
0638
I_0_I_0_I
0693
Keypad Sound on Alarm I_0_I_0_I
0529
I_0_I_0_I
0584
I_0_I_0_I
0639
I_0_I_0_I
0694
2-Wire Smoke Detector
(Zone 7 & 8 Only)
I_?_I_0_I
0530
I_0_I_0_I
0585
Fire Zone I_0_I_0_I
0531
I_0_I_0_I
0586
I_0_I_0_I
0641
I_0_I_0_I
0696
Fire Alarm Verification I_0_I_0_I
0532
I_0_I_0_I
0587
I_0_I_0_I
0642
I_0_I_0_I
0697
Reserved Future Use I_0_I_0_I
0533
I_0_I_0_I
0588
Zone ANDing Group 1 I_0_I_0_I
0534
I_0_I_0_I
0589
I_0_I_0_I
0644
I_0_I_0_I
0699
Zone ANDing Group 2 I_0_I_0_I
0535
I_0_I_0_I
0590
I_0_I_0_I
0645
I_0_I_0_I
0700
Zone ANDing Group 3 I_0_I_0_I
0536
I_0_I_0_I
0591
I_0_I_0_I
0646
I_0_I_0_I
0701
Zone ANDing Group 4 I_0_I_0_I
0537
I_0_I_0_I
0592
I_0_I_0_I
0647
I_0_I_0_I
0702
Sensor Watch I_0_I_0_I
0538
I_0_I_0_I
0593
I_0_I_0_I
0648
I_0_I_0_I
0703
Reserved Future Use I_0_I_0_I
0539
I_0_I_0_I
0594
I_0_I_0_I
0649
I_0_I_0_I
0704
Chime 2 I_0_I_0_I
0540
I_0_I_0_I
0595
I_0_I_0_I
0650
I_0_I_0_I
0705

CS Area & System Reporting Options

1 = Reserved
2 = Autoarm if not closed at window
4 = Disable Time/Date at Keypad
8 = Disable Zone Fault Scrolling
I_0_I_0_I
0718
1 = Opening only after Alarm
2 = Closing only w/Conditional Close
4 = Include Sel/Grp Bypass
8 = Status Report

1 = Access Control on PGM2
2 = Maintained Keyswitch Arming
4 = Reserved
8 = Disable Keypad Instant Mode
I_0_I_0_I
0719
1 = Auto Bell Test at Arming
2 = Reset after Burg Output Timeout
4 = Supress Byp Reminder w/Armed
8 = Reserved

1 = Disable Keypad Download
2 = Disable Callback Download
4 = PGM2 Output Chirp on Keyfob Arming
8 = Change Pulse Output to Cadence
I_0_I_D_I
0720
1 = Reserved
2 = Enable Global Ambush Code
4 = Reset Day Zone with Arm/Disarm
8 = Enable Residential Fire

1 = Line Fault Test w/Armed
2 = Enable Line Fault Test
4 = Inhibit Trouble Audible at Keypad
8 = Reserved
I_0_I_0_I
0721
1 = Reserved
2 = Wireless Trouble Activates Telco 1
4 = Wireless Trouble Activates Telco 3
8 = Enable Alarm Output on Telco
Fail only when Armed

1 = Don’t Clear PGM2 on
Arm/Disarm
2 = 2nd Ring Download
4 = Reserved
8 = Reserved Smoke Low Battery

I_0_I_0_I
0722
1 = Reserved
2 = Veriphone Zones Trip PGM2
4 = Veriphone Zns over Priority Alarm
8 = Resound on Wireless Smoke
1 = Reserved
2 = Disable Auto Cancel on Disarm
4 = Disable System Trbl Aud Timeout
8 = Reserved
I_0_I_1_I
1060
1 = Enable Set Time/Date Message
2 = Enable Cancel Report to Telco 3
4 = Disable ON/OFF as EZ-Exit
8 = Enable GEM-PRINT Module


Global System Event/Trouble

Alarm Output
    1 = Low Battery
2 = AC Failure
4 = EZM Tamper
8 = Bell Supervision
I_0_I_0_I
0460
1 = Test Timer
2 = Telco Failure
4 = RF Receiver Trouble
8 = Memory Failure

Pulsed Alarm Output
1 = Low Battery
2 = AC Failure
4 = EZM Tamper
8 = Bell Supervision
I_0_I_0_I
0461
1 = Test Timer
2 = Telco Failure
4 = RF Receiver Trouble
8 = Memory Failure

PGM1 Output
1 = Low Battery
2 = AC Failure
4 = EZM Tamper
8 = Bell Supervision
I_0_I_0_I
0462
1 = Test Timer
2 = Telco Failure
4 = RF Receiver Trouble
8 = Memory Failure

PGM2 Output
1 = Low Battery
2 = AC Failure
4 = EZM Tamper
8 = Bell Supervision
I_0_I_0_I
0463
1 = Test Timer
2 = Telco Failure
4 = RF Receiver Trouble
8 = Memory Failure

Report Event Telco 1
1 = Low Battery
2 = AC Failure
4 = EZM Tamper
8 = Bell Supervision
I_0_I_0_I
0464
1 = Test Timer
2 = Telco Failure
4 = RF Receiver Trouble
8 = Memory Failure

Report Restore Telco 1
1 = Low Battery
2 = AC Failure
4 = EZM Tamper
8 = Bell Supervision
I_0_I_0_I
0465
1 = Test Timer
2 = Telco Failure
4 = RF Receiver Trouble
8 = Memory Failure

Report Event Telco 3
1 = Low Battery
2 = AC Failure
4 = EZM Tamper
8 = Bell Supervision
I_0_I_0_I
0468
1 = Test Timer
2 = Telco Failure
4 = RF Receiver Trouble
8 = Memory Failure

Report Restore Telco 3
1 = Low Battery
2 = AC Failure
4 = EZM Tamper
8 = Bell Supervision
I_0_I_0_I
0469
1 = Test Timer
2 = Telco Failure
4 = RF Receiver Trouble
8 = Memory Failure


Area 1 System Event/Trouble

Pulsed Alarm Output
1 = Keypad Tamper
2 = Fail to Open
4 = Fail to Close
8 = Keyfob Low Battery
I_0_I_4_I
0470
1 = Ambush
2 = Keypad Panic
4 = Keypad Fire Panic
8 = Keypad Auxiliary Panic

Alarm Output
1 = Keypad Tamper
2 = Fail to Open
4 = Fail to Close
8 = Keyfob Low Battery
I_0_I_4_I
0471
1 = Ambush
2 = Keypad Panic
4 = Keypad Fire Panic
8 = Keypad Auxiliary Panic

PGM1 Output
1 = Keypad Tamper
2 = Fail to Open
4 = Fail to Close
8 = Keyfob Low Battery
I_0_I_4_I
0472
1 = Ambush
2 = Keypad Panic
4 = Keypad Fire Panic
8 = Keypad Auxiliary Panic

PGM2 Output
1 = Keypad Tamper
2 = Fail to Open
4 = Fail to Close
8 = Keyfob Low Battery
I_0_I_4_I
0474
1 = Ambush
2 = Keypad Panic
4 = Keypad Fire Panic
8 = Keypad Auxiliary Panic

Report Event Telco 1
1 = Keypad Tamper
2 = Fail to Open
4 = Fail to Close
8 = Keyfob Low Battery
I_0_I_F_I
0475
1 = Ambush
2 = Keypad Panic
4 = Keypad Fire Panic
8 = Keypad Auxiliary Panic

Report Event Telco 3
1 = Keypad Tamper
2 = Fail to Open
4 = Fail to Close
8 = Keyfob Low Battery
I_0_I_0_I
0477
1 = Ambush
2 = Keypad Panic
4 = Keypad Fire Panic
8 = Keypad Auxiliary Panic


Area 2 System Event/Trouble

Pulsed Alarm Output
1 = Keypad Tamper
2 = Fail to Open
4 = Fail to Close
8 = Keyfob Low Battery
I_0_I_4_I
0478
1 = Ambush
2 = Keypad Panic
4 = Keypad Fire Panic
8 = Keypad Auxiliary Panic

Alarm Output
1 = Keypad Tamper
2 = Fail to Open
4 = Fail to Close
8 = Keyfob Low Battery
I_0_I_4_I
0479
1 = Ambush
2 = Keypad Panic
4 = Keypad Fire Panic
8 = Keypad Auxiliary Panic

PGM1 Output
1 = Keypad Tamper
2 = Fail to Open
4 = Fail to Close
8 = Keyfob Low Battery
I_0_I_4_I
0480
1 = Ambush
2 = Keypad Panic
4 = Keypad Fire Panic
8 = Keypad Auxiliary Panic

PGM2 Output
1 = Keypad Tamper
2 = Fail to Open
4 = Fail to Close
8 = Keyfob Low Battery
I_0_I_4_I
0482
1 = Ambush
2 = Keypad Panic
4 = Keypad Fire Panic
8 = Keypad Auxiliary Panic

Report Event Telco 1
1 = Keypad Tamper
2 = Fail to Open
4 = Fail to Close
8 = Keyfob Low Battery
I_0_I_F_I
0483
1 = Ambush
2 = Keypad Panic
4 = Keypad Fire Panic
8 = Keypad Auxiliary Panic

Report Event Telco 3
1 = Keypad Tamper
2 = Fail to Open
4 = Fail to Close
8 = Keyfob Low Battery
I_0_I_0_I
0485
1 = Ambush
2 = Keypad Panic
4 = Keypad Fire Panic
8 = Keypad Auxiliary Panic


Keypad Options     (0 = BLANK)

Keypad 1 Type I_0_I_1_I
0723
Left Digit Right Digit
BLANK = Burg Keypad BLANK = Keypad Disabled
2 = Wizard (Remote module) 1 = Area 1 (Partition 1)
2 = Area 2 (Partition 2)
Keypad 2 Type I_0_I_?_I
0724
Keypad 3 Type I_0_I_?_I
0725
Keypad 4 Type I_0_I_?_I
0726
Keypad 5 Type I_0_I_?_I
0727
Keypad 6 Type I_0_I_?_I
0728
Keypad 7 Type I_0_I_?_I
0729
Keypad 1 1 = Enable Ambush
2 = Easy Arming (Quick Arm)
4 = Panel Access (User Program)
8 = Reserved
I_7_I_7_I
0730
1 = Keypad Fire Enable
2 = Keypad Medical Enable
4 = Keypad Panic Enable
8 = Reserved

Keypad 2 1 = Enable Ambush
2 = Easy Arming (Quick Arm)
4 = Panel Access (User Program)
8 = Reserved
I_7_I_7_I
0731
1 = Keypad Fire Enable
2 = Keypad Medical Enable
4 = Keypad Panic Enable
8 = Reserved

Keypad 3 1 = Enable Ambush
2 = Easy Arming (Quick Arm)
4 = Panel Access (User Program)
8 = Reserved
I_7_I_7_I
0732
1 = Keypad Fire Enable
2 = Keypad Medical Enable
4 = Keypad Panic Enable
8 = Reserved

Keypad 4 1 = Enable Ambush
2 = Easy Arming (Quick Arm)
4 = Panel Access (User Program)
8 = Reserved
I_7_I_7_I
0733
1 = Keypad Fire Enable
2 = Keypad Medical Enable
4 = Keypad Panic Enable
8 = Reserved

Keypad 5 1 = Enable Ambush
2 = Easy Arming (Quick Arm)
4 = Panel Access (User Program)
8 = Reserved
I_7_I_7_I
0734
1 = Keypad Fire Enable
2 = Keypad Medical Enable
4 = Keypad Panic Enable
8 = Reserved

Keypad 6 1 = Enable Ambush
2 = Easy Arming (Quick Arm)
4 = Panel Access (User Program)
8 = Reserved
I_7_I_7_I
0735
1 = Keypad Fire Enable
2 = Keypad Medical Enable
4 = Keypad Panic Enable
8 = Reserved

Keypad 7 1 = Enable Ambush
2 = Easy Arming (Quick Arm)
4 = Panel Access (User Program)
8 = Reserved
I_7_I_7_I
0736
1 = Keypad Fire Enable
2 = Keypad Medical Enable
4 = Keypad Panic Enable
8 = Reserved


User Reporting Options

User Opening Telco 1 I_0_I_0_I
0440
I_0_I_0_I
0441
I_0_I_0_I
0442
I_0_I_0_I
0443
User Closing Telco 1 I_0_I_0_I
0445
I_0_I_0_I
0446
I_0_I_0_I
0447
I_0_I_0_I
0448
User Opening Telco 3 I_0_I_0_I
0450
I_0_I_0_I
0451
I_0_I_0_I
0452
I_0_I_0_I
0453
User Closing Telco 3 I_0_I_0_I
0455
I_0_I_0_I
0456
I_0_I_0_I
0457
I_0_I_0_I
0458
User Opening Telco 1 I_0_I_0_I
0444
Disable Opening
Reports
I_1_I_0_I
0391
Left Digit
1 = Area 1   2 = Area 2

Right Digit
0 = Disabled (Not Used)
User Closing Telco 1   I_0_I_0_I  
0449
Disable Closing
Reports
  I_1_I_0_I  
0392
User Opening Telco 3 I_0_I_0_I
0454
User Closing Telco 3 I_0_I_0_I
0459

Area Arming Options

Priority Arming Area 1   I_0_I_0_I  
0743
Left Digit: Must be 0 (Blank)
Right Digit: 0 = Disabled, 2 = Enabled
Priority Arming Area 2 I_0_I_0_I
0744
Left Digit: Must be 0 (Blank)
Right Digit: 0 = Disabled, 1 = Enabled

RF Receiver & Supervisory Timer Options

Number RF Receivers   I_0_I_0_I  
1180
Digit 1 = Must be Blank
Digit 2 = 1 for 1 RF Receiver
2 for 2 RF Receivers