MultiFamily NMF 1000 / 8580 Program

Modules PC5132 Wireless Receiver
PC5400 Printer Module
Will not support PC5908/5928 Intercom or PC5580 Escort
Report Format SIA, Contact ID, 4/2, 3/1
Enter Program * 8 0580 (v2.1) or 5555 (v2.3)
Exit Program #
Move to location Enter 3-digit location, some areas may require # to exit
Default Panel 1. Power down then up, if board clicks panel is locked out (replace board)
2. If no clicks jumper from ZN 1 to PGM1, power up, wait 10 seconds
Enable Download * + 6 + Master Code + 5 (Enables for 6 hours)
(System also enables downloading for 1 hour if powered down then up)
Hex Program A = * 1 * B = * 2 * C = * 3 * D = * 4 * E = * 5 * F = * 6 *

[000] Keypad Assignment (must be done at each keypad)
[0] Slot (Valid entries 11 to 18 for Slot 1 to 8)
[1] Function Key 1 Assignment (Default = 03)
[2] Function Key 2 Assignment (Default = 04)
[3] Function Key 3 Assignment (Default = 06)
[4] Function Key 4 Assignment (Default = 14)
[5] Function Key 5 Assignment (Default = 16)
00 Null Key (Not Used) 08 * 1 Bypass Mode 16 * 0 Quick Exit
01 Not Used 09 * 2 Trouble Display 17 * 1 Reactivate Stay/Away’s
02 Not Used 10 * 3 Alarm Memory
03 Stay Arm 11 * 5 User Programming
04 Away Arm 12 * 6 User Functions
05 * 9 No-Entry Arm 13 * 7 1 Utility Output
06 * 4 Chime On/Off 14 * 7 2 Sensor Reset
07 * 6 4 System Test 15 Not Used
If multiple LCD keypads make one slot 8 to enable Zone description programming by downloader
[001] Zone 1-8 Definitions
Default Default
01 I_ _I_ _I Zone 01 05 I_ _I_ _I Zone 05
03 I_ _I_ _I Zone 02 05 I_ _I_ _I Zone 06
03 I_ _I_ _I Zone 03 05 I_ _I_ _I Zone 07
03 I_ _I_ _I Zone 04 05 I_ _I_ _I Zone 08
00 = Null Zone 09 = 24 Hr Supervisory (Links) 18 = 24hr Sprinkler
01 = Delay 1 10 = 24hr Supervisory Buzzer 19 = 24hr Water
02 = Delay 2 11 = 24hr Burglary 20 = 24hr Freeze
03 = Instant 12 = 24hr Holdup 21 = 24hr Latching Tamper
04 = Interior 13 = 24hr Gas 22 = Momentary Keyswitch Arm
05 = Interior Stay/Away 14 = 24hr Heat 23 = Maintained Keyswitch Arm
06 = Delay Stay/Away 15 = 24hr Medical 24 = Links Answer
07 = Delay 24hr Fire 16 = 24hr Panic 25 = Interior Delay
08 = Standard 24hr Fire 17 = 24 hr Emergency 87 = Delay Wireless Fire
88 = Standard Wireless Fire
[002] Zone 9-16 Zone Definitions (PC580 v2.3 only)
Default Default
00 I_ _I_ _I Zone 09 00 I_ _I_ _I Zone 13
00 I_ _I_ _I Zone 10 00 I_ _I_ _I Zone 14
00 I_ _I_ _I Zone 11 00 I_ _I_ _I Zone 15
00 I_ _I_ _I Zone 12 00 I_ _I_ _I Zone 16

[003] Zone 17-24 Definitions (PC580 v2.3 only)
Default Default
00 I_ _I_ _I Zone 17 00 I_ _I_ _I Zone 21
00 I_ _I_ _I Zone 18 00 I_ _I_ _I Zone 22
00 I_ _I_ _I Zone 19 00 I_ _I_ _I Zone 23
00 I_ _I_ _I Zone 20 00 I_ _I_ _I Zone 24

[004] Zone 25-32 Definitions (PC580 v2.3 only)
Default Default
00 I_ _I_ _I Zone 25 00 I_ _I_ _I Zone 29
00 I_ _I_ _I Zone 26 00 I_ _I_ _I Zone 30
00 I_ _I_ _I Zone 27 00 I_ _I_ _I Zone 31
00 I_ _I_ _I Zone 28 00 I_ _I_ _I Zone 32

[005] System Times
Default
030 I_ _I_ _I_ _I Entry Delay 1 Enter 3 digits from [000-255]
045 I_ _I_ _I_ _I Entry Delay 2 Enter 3 digits from [000-255]
120 I_ _I_ _I_ _I Exit Delay Enter 3 digits from [000-255]
006 I_ _I_ _I_ _I Bell Cut-off Enter 3 digits from [000-255]
[006] Installer’s Code
Default
5010 I_ _I_ _I_ _I_ _I

[007] Master Code
Default
1234 I_ _I_ _I_ _I_ _I

[008] Maintenance Code
Default
AAAA I_ _I_ _I_ _I_ _I

[009] PCS5010 PGM Output Programming (PGM 1 & 2)
Default
19 I_ _I_ _I PGM 01
10 I_ _I_ _I PGM 02
Programmable Output Options
00 = Not Used 11 = System Tamper
01 = Burg/Fire Bell Output 12 = TLM and Alarm
02 = For Future Use 13 = Kissoff Output
03 = Sensor Reset (4-wire Smokes *72) 14 = Ground Start Pulse
04 = For Future Use 15 = Remote Operation (DLS-1)
05 = System (Parition) Armed Status 16 = Links 1000 Support (PGM1 only)
06 = Ready To Arm 17 = Away Armed Status
07 = Keypad Buzzer Follow Mode 18 = Stay Armed Status
08 = Courtesy Pulse 19 = [*] [7] [1] Command Output
09 = System Trouble Output 20 = [*] [7] [2] Command Output
10 = Latched System Event/Strobe 21 to 24 For Future Use
[012] Keypad Lockout Options
Default
000 I_0_I_0_I_0_I Number of Invalid Codes Before Lockout
000 I_0_I_0_I_0_I Lockout Duration (in minutes)
[013] First System Option Code
Default Option ON OFF
OFF I_OFF_I 1 Normally Closed Loops End-of-Line Resistors
OFF I_OFF_I 2 Double End-of-Line Resistors Single End-of-Line Resistors
ON I_ON_I 3 Panels shows trouble w/Armed Panel shows Fire Trbl only w/Armed
ON I_ON_I 4 Tamper/Fault do not show open Tampers/Fault show open
OFF I_OFF_I 5 For Future Use For Future Use
OFF I_OFF_I 6 Audible Exit Fault Enabled Audible Exit Fault Disabled
ON I_ON_I 7 Event Buffer follows Swinger Event Buf Logs Events Past swinger
OFF I_OFF_I 8 Temporal Three Fire Signal Enabled Standard Pulsed Fire

[014] Second System Option Code
Default Option ON OFF
OFF I_OFF_I 1 Arm/Disarm Bell Squawk enable Arm/Disarm Bell Squawk disable
OFF I_OFF_I 2 Bell Squawk During Auto Arm No Bell Squawk
ON I_ON_I 3 Bell Squawk On Exit Delay No Bell Squawk
OFF I_OFF_I 4 Bell Squawk On Entry Delay No Bell Squawk
OFF I_OFF_I 5 Bell Squawk On Trouble No Bell Squawk
ON I_???_I 6 Audible Exit Beeps Silent Exit Delay
ON I_ON_I 7 Exit Delay Termination Enabled Exit Del. Termination Disabled
ON I_ON_I 8 Fire Bell is Continuous Fire Bell follows Bell Cut-Off

[015] Third System Option Code
Default Option ON OFF
ON I_ON_I 1 [F] Keys Enabled Fire Keys Disabled
OFF I_ON_I 2 Panic Keys Audible Panic Keys Silent
OFF I_ON_I 3 Quick Exit Enabled Quick Exit Disabled
ON I_ON_I 4 Quick Arming Enabled Function Keys Disabled
OFF I_OFF_I 5 Code Required for Bypassing Code not Required
OFF I_OFF_I 6 Master Code Not Changable Master Code Changable
ON I_ON_I 7 TLM Enabled (Phone Monitor) TLM Disabled
OFF I_ON_I 8 TLM Audible When Armed TLM Trouble Only W/Armed

[016] Fourth System Option Code
Default Option ON OFF
ON I_ON_I 1 AC Trouble Displayed AC Trouble not Displayed
OFF I_OFF_I 2 Trouble Flashes if AC Fails Trouble doesn’t follow AC
OFF I_OFF_I 3 Blank Keypad When Not Used Keypad always Active
OFF I_OFF_I 4 Code Req. to Stop KP Blanking No Code Required
OFF I_OFF_I 5 Keypad Backlight Enabled Keypad Backlighting Disabled
OFF I_OFF_I 6 Power Save Mode Enabled Power Save Mode Disabled
OFF I_OFF_I 7 Bypass Shows while Armed Bypass doesn’t show/Armed
OFF I_OFF_I 8 Keypad Tampers Enabled Keypad Tampers disabled

[017] Fifth System Option Code (Version 2.3 Only)
Default Option ON OFF
ON I_ON_I 1 WLS Keyfob does not use Code WLS Keyfob uses Code
OFF I_OFF_I 2-7 For Future Use
OFF I_OFF_I 8 Bell Squawk Away Arm/Disarm Bell Squawk on all Arm/Disarm

[020] Keypad Zone Assignments (If using Z type keypads)
Default
00 I_ _I_ _I Keypad (Slot 1) Zone Valid entries are 01-08
00 I_ _I_ _I Keypad (Slot 2) Zone
00 I_ _I_ _I Keypad (Slot 3) Zone First assign keypad slot in 000 section 0 (11 to 18)
00 I_ _I_ _I Keypad (Slot 4) Zone (Keypad added as 11 would be Slot 1 here, 18 is Slot 8)
00 I_ _I_ _I Keypad (Slot 5) Zone then add Zone number here in proper slot
00 I_ _I_ _I Keypad (Slot 6) Zone (Ex: Zone 07 to Keypad 12 enter 00 07 00 00 00 00 00 00)
00 I_ _I_ _I Keypad (Slot 7) Zone (Keypad zones over-ride regular hardwire zones)
00 I_ _I_ _I Keypad (Slot 8) Zone (If Panel uses Resistors Keypad zone must too)
(1 keypad zone replaces 1 onboard panel zone)

[030] Fourth System Option Code
Default Option ON OFF
OFF I_OFF_I 1 Zone 1 is Fast Loop Response Zone 1 is Normal Loop Response
OFF I_OFF_I 2 Zone 2 is Fast Loop Response Zone 2 is Normal Loop Response
OFF I_OFF_I 3 Zone 3 is Fast Loop Response Zone 3 is Normal Loop Response
OFF I_OFF_I 4 Zone 4 is Fast Loop Response Zone 4 is Normal Loop Response
OFF I_OFF_I 5 to 8 For Future Use

Zone Attributes

Opt 1 Opt 2 Opt 3 Opt 4 Opt 5 Opt 6 Opt 7 Opt 8
ON Audible Steady Chime Bypass Force Swinger   Tx Delay   Wireless
OFF Silent Pulsed No No No No No No
[101] Zone 1 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I
To
[132] Zone 32 I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I I_ _I

PGM Attributes

Opt 1 Opt 2 Opt 3 Opt 4 Opt 5
ON Output Enabled Not Used True Output   Follows Timer Code Req.
OFF Output Disabled   Not Used Inverted ON/OFF No Code Req.
[141] PGM 1 I_ _I I_ _I I_ _I I_ _I I_ _I
[142] PGM 2 I_ _I I_ _I I_ _I I_ _I I_ _I
[160] Maximum Dialing Attempts to Each Phone Number
Default
008 I_ _I_ _I_ _I Valid entries are 001-255 attempts (Do not enter 000)

[161] Post Dial Wait for Handshake
Default
040 I_ _I_ _I_ _I Valid entries are 001-255 seconds

[164] PGM Output Timer
Default
005 I_ _I_ _I_ _I Valid entries are 001-255 seconds

[202] Zone Assignments 1 to 8 (Toggle 1 to 8 ON to enable, OFF to disable)
Default Option ON OFF
ON I_ON_I 1 Zone 1 is enabled Zone 1 is not enabled
ON I_ON_I 2 Zone 2 is enabled Zone 2 is not enabled
ON I_ON_I 3 Zone 3 is enabled Zone 3 is not enabled
ON I_ON_I 4 Zone 4 is enabled Zone 4 is not enabled
ON I_ON_I 5 Zone 5 is enabled Zone 5 is not enabled
ON I_ON_I 6 Zone 6 is enabled Zone 6 is not enabled
ON I_ON_I 7 Zone 7 is enabled Zone 7 is not enabled
ON I_ON_I 8 Zone 8 is enabled Zone 8 is not enabled

[203] Zone Assignments 9 to 16 (PC580 v2.3 only)
Default Option ON OFF
ON I_ON_I 1 Zone 9 is enabled Zone 1 is not enabled
ON I_ON_I 2 Zone 10 is enabled Zone 2 is not enabled
ON I_ON_I 3 Zone 11 is enabled Zone 3 is not enabled
ON I_ON_I 4 Zone 12 is enabled Zone 4 is not enabled
ON I_ON_I 5 Zone 13 is enabled Zone 5 is not enabled
ON I_ON_I 6 Zone 14 is enabled Zone 6 is not enabled
ON I_ON_I 7 Zone 15 is enabled Zone 7 is not enabled
ON I_ON_I 8 Zone 16 is enabled Zone 8 is not enabled

[204] Zone Assignments 17 to 24 (PC580 v2.3 only)
Default Option ON OFF
ON I_ON_I 1 Zone 17 is enabled Zone 17 is not enabled
ON I_ON_I 2 Zone 18 is enabled Zone 18 is not enabled
ON I_ON_I 3 Zone 19 is enabled Zone 19 is not enabled
ON I_ON_I 4 Zone 20 is enabled Zone 20 is not enabled
ON I_ON_I 5 Zone 21 is enabled Zone 21 is not enabled
ON I_ON_I 6 Zone 22 is enabled Zone 22 is not enabled
ON I_ON_I 7 Zone 23 is enabled Zone 23 is not enabled
ON I_ON_I 8 Zone 24 is enabled Zone 24 is not enabled

[205] Zone Assignments 25 to 32 (PC580 v2.3 only)
Default Option ON OFF
ON I_ON_I 1 Zone 25 is enabled Zone 25 is not enabled
ON I_ON_I 2 Zone 26 is enabled Zone 26 is not enabled
ON I_ON_I 3 Zone 27 is enabled Zone 27 is not enabled
ON I_ON_I 4 Zone 28 is enabled Zone 28 is not enabled
ON I_ON_I 5 Zone 29 is enabled Zone 29 is not enabled
ON I_ON_I 6 Zone 30 is enabled Zone 30 is not enabled
ON I_ON_I 7 Zone 31 is enabled Zone 31 is not enabled
ON I_ON_I 8 Zone 32 is enabled Zone 32 is not enabled

Communicator Programming

[301] First Telephone Number (32 Digits)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
*2 = * *3 = # *4 = Wait for Dial Tone *5=2 Sec Pause *6 End Number
(If adding more than one hex digit Example: *555* gives 3 2-second pauses)

[302] Second Telephone Number
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
Program Pager number + pauses *5555* gives 4 2-second pauses, uses 1st Account #

[303] Third Telephone Number (32 Digits)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I

[310] First/Third Receiver Telephone Account Code (4 Digits)
I_ _I_ _I_ _I_ _I
If SIA enter 0 if any 0 in Account Number
If 4/2 or Contact ID use *1* for any 0 in Account Number
Pager will not send properly if Hex Characters A C D F are in Account Number

[311] Second Receiver Telephone Account Code (4 Digits)
I_ _I_ _I_ _I_ _I

[320] Alarm Report Codes Zone 1 to 8
I_F_I_F_I   Zone 1 Alarm I_F_I_F_I   Zone 5 Alarm
I_F_I_F_I Zone 2 Alarm I_F_I_F_I Zone 6 Alarm
I_F_I_F_I Zone 3 Alarm I_F_I_F_I Zone 7 Alarm
I_F_I_F_I Zone 4 Alarm I_F_I_F_I Zone 8 Alarm

[321] Alarm Report Codes Zone 9 to 16 (PC580 v2.3 only)
I_F_I_F_I Zone 9 Alarm I_F_I_F_I Zone 13 Alarm
I_F_I_F_I Zone 10 Alarm I_F_I_F_I Zone 14 Alarm
I_F_I_F_I Zone 11 Alarm I_F_I_F_I Zone 15 Alarm
I_F_I_F_I Zone 12 Alarm I_F_I_F_I Zone 16 Alarm

[322] Alarm Report Codes Zone 17 to 24 (PC580 v2.3 only)
I_F_I_F_I Zone 17 Alarm I_F_I_F_I Zone 21 Alarm
I_F_I_F_I Zone 18 Alarm I_F_I_F_I Zone 22 Alarm
I_F_I_F_I Zone 19 Alarm I_F_I_F_I Zone 23 Alarm
I_F_I_F_I Zone 20 Alarm I_F_I_F_I Zone 24 Alarm

[323] Alarm Report Codes Zone 25 to 32 (PC580 v2.3 only)
I_F_I_F_I Zone 25 Alarm I_F_I_F_I Zone 29 Alarm
I_F_I_F_I Zone 26 Alarm I_F_I_F_I Zone 30 Alarm
I_F_I_F_I Zone 27 Alarm I_F_I_F_I Zone 31 Alarm
I_F_I_F_I Zone 28 Alarm I_F_I_F_I Zone 32 Alarm

[324] Alarm Restoral Report Codes Zones 1 to 8
I_0_I_0_I Zone 1 Restoral I_0_I_0_I Zone 5 Restoral
I_0_I_0_I Zone 2 Restoral I_0_I_0_I Zone 6 Restoral
I_0_I_0_I Zone 3 Restoral I_0_I_0_I Zone 7 Restoral
I_0_I_0_I Zone 4 Restoral I_0_I_0_I Zone 8 Restoral

[325] Alarm Restoral Report Codes Zone 9 to 16 (PC580 v2.3 only)
I_0_I_0_I Zone 9 Restoral I_0_I_0_I Zone 13 Restoral
I_0_I_0_I Zone 10 Restoral I_0_I_0_I Zone 14 Restoral
I_0_I_0_I Zone 11 Restoral I_0_I_0_I Zone 15 Restoral
I_0_I_0_I Zone 12 Restoral I_0_I_0_I Zone 16 Restoral

[326] Alarm Restoral Report Codes Zone 17 to 24 (PC580 v2.3 only)
I_0_I_0_I Zone 17 Restoral I_0_I_0_I Zone 21 Restoral
I_0_I_0_I Zone 18 Restoral I_0_I_0_I Zone 22 Restoral
I_0_I_0_I Zone 19 Restoral I_0_I_0_I Zone 23 Restoral
I_0_I_0_I Zone 20 Restoral I_0_I_0_I Zone 24 Restoral

[327] Alarm Restoral Report Codes Zone 25 to 32 (PC580 v2.3 only)
I_0_I_0_I Zone 25 Restoral I_0_I_0_I Zone 29 Restoral
I_0_I_0_I Zone 26 Restoral I_0_I_0_I Zone 30 Restoral
I_0_I_0_I Zone 27 Restoral I_0_I_0_I Zone 31 Restoral
I_0_I_0_I Zone 28 Restoral I_0_I_0_I Zone 32 Restoral

[328] Miscellaneous Alarm Reporting Codes
I_F_I_F_I Duress I_F_I_F_I Zone Expander Supervisory Alarm
I_F_I_F_I Opening After Alarm I_F_I_F_I Zone Expander Supervisory Restore
I_F_I_F_I Recent Closing/Exit Alarm     I_F_I_F_I Cross Zone Police Alarm

[329] Priority Alarm and Restoral
I_F_I_F_I Keypad Fire Alarm I_F_I_F_I Keypad Fire Restoral
I_F_I_F_I Keypad Aux Alarm I_F_I_F_I Keypad Aux Restoral
I_F_I_F_I Keypad Panic Alarm I_F_I_F_I Keypad Panic Restoral
I_F_I_F_I For Future Use I_F_I_F_I For Future Use

[330] Tamper Reporting Codes, Zones 1-8
I_F_I_F_I Zone 01 Tamper I_F_I_F_I Zone 05 Tamper
I_F_I_F_I Zone 02 Tamper I_F_I_F_I Zone 06 Tamper
I_F_I_F_I Zone 03 Tamper I_F_I_F_I Zone 07 Tamper
I_F_I_F_I Zone 04 Tamper I_F_I_F_I Zone 08 Tamper

[331] Tamper Report Codes Zone 9 to 16 (PC580 v2.3 only)
I_F_I_F_I Zone 09 Tamper I_F_I_F_I Zone 13 Tamper
I_F_I_F_I Zone 10 Tamper I_F_I_F_I Zone 14 Tamper
I_F_I_F_I Zone 11 Tamper I_F_I_F_I Zone 15 Tamper
I_F_I_F_I Zone 12 Tamper I_F_I_F_I Zone 16 Tamper

[332] Tamper Report Codes Zone 17 to 24 (PC580 v2.3 only)
I_F_I_F_I Zone 17 Tamper I_F_I_F_I Zone 21 Tamper
I_F_I_F_I Zone 18 Tamper I_F_I_F_I Zone 22 Tamper
I_F_I_F_I Zone 19 Tamper I_F_I_F_I Zone 23 Tamper
I_F_I_F_I Zone 20 Tamper I_F_I_F_I Zone 24 Tamper

[333] Tamper Report Codes Zone 25 to 32 (PC580 v2.3 only)
I_F_I_F_I Zone 25 Tamper I_F_I_F_I Zone 29 Tamper
I_F_I_F_I Zone 26 Tamper I_F_I_F_I Zone 30 Tamper
I_F_I_F_I Zone 27 Tamper I_F_I_F_I Zone 31 Tamper
I_F_I_F_I Zone 28 Tamper I_F_I_F_I Zone 32 Tamper

[334] Tamper Restoral Reporting Codes, Zones 1-8
I_F_I_F_I Zone 01 Tamper Restoral I_F_I_F_I Zone 05 Tamper Restoral
I_F_I_F_I Zone 02 Tamper Restoral I_F_I_F_I Zone 06 Tamper Restoral
I_F_I_F_I Zone 03 Tamper Restoral I_F_I_F_I Zone 07 Tamper Restoral
I_F_I_F_I Zone 04 Tamper Restoral I_F_I_F_I Zone 08 Tamper Restoral

[335] Tamper Restoral Report Codes Zone 9 to 16 (PC580 v2.3 only)
I_F_I_F_I Zone 09 Tamper Restoral I_F_I_F_I Zone 13 Tamper Restoral
I_F_I_F_I Zone 10 Tamper Restoral I_F_I_F_I Zone 14 Tamper Restoral
I_F_I_F_I Zone 11 Tamper Restoral I_F_I_F_I Zone 15 Tamper Restoral
I_F_I_F_I Zone 12 Tamper Restoral I_F_I_F_I Zone 16 Tamper Restoral

[336] Tamper Restoral Report Codes Zone 17 to 24 (PC580 v2.3 only)
I_F_I_F_I Zone 17 Tamper Restoral I_F_I_F_I Zone 21 Tamper Restoral
I_F_I_F_I Zone 18 Tamper Restoral I_F_I_F_I Zone 22 Tamper Restoral
I_F_I_F_I Zone 19 Tamper Restoral I_F_I_F_I Zone 23 Tamper Restoral
I_F_I_F_I Zone 20 Tamper Restoral I_F_I_F_I Zone 24 Tamper Restoral

[337] Tamper Restoral Report Codes Zone 25 to 32 (PC580 v2.3 only)
I_F_I_F_I Zone 25 Tamper Restoral I_F_I_F_I Zone 29 Tamper Restoral
I_F_I_F_I Zone 26 Tamper Restoral I_F_I_F_I Zone 30 Tamper Restoral
I_F_I_F_I Zone 27 Tamper Restoral I_F_I_F_I Zone 31 Tamper Restoral
I_F_I_F_I Zone 28 Tamper Restoral I_F_I_F_I Zone 32 Tamper Restoral

[338] Miscellaneous Tamper Reporting Codes
I_F_I_F_I General System Tamper
I_F_I_F_I General System Tamper Restoral
I_F_I_F_I Keypad Lockout

[339] Closing (Arming) Reporting Codes, Access Codes 1-8
I_0_I_0_I User Code 01 I_0_I_0_I User Code 05
I_0_I_0_I User Code 02 I_0_I_0_I User Code 06
I_0_I_0_I User Code 03 I_0_I_0_I User Code 07
I_0_I_0_I User Code 04 I_0_I_0_I User Code 08

[340] Closing (Arming) Reporting Codes, Access Codes 9-16
I_0_I_0_I User Code 09 I_0_I_0_I User Code 13
I_0_I_0_I User Code 10 I_0_I_0_I User Code 14
I_0_I_0_I User Code 11 I_0_I_0_I User Code 15
I_0_I_0_I User Code 12 I_0_I_0_I User Code 16

[341] Closing (Arming) Reporting Codes, Access Codes 17-24
I_0_I_0_I User Code 17 I_0_I_0_I User Code 21
I_0_I_0_I User Code 18 I_0_I_0_I User Code 22
I_0_I_0_I User Code 19 I_0_I_0_I User Code 23
I_0_I_0_I User Code 20 I_0_I_0_I User Code 24

[342] Closing (Arming) Reporting Codes, Access Codes 25-32
I_0_I_0_I User Code 25 I_0_I_0_I User Code 29
I_0_I_0_I User Code 26 I_0_I_0_I User Code 30
I_0_I_0_I User Code 27 I_0_I_0_I User Code 31
I_0_I_0_I User Code 28 I_0_I_0_I User Code 32

[343] Miscellaneous Closing (Arming) Reporting Codes
I_0_I_0_I Duress User 33 I_0_I_0_I Master Code 42
I_0_I_0_I Duress User 34 I_0_I_0_I Partial Closing
I_0_I_0_I Master Code 40 I_0_I_0_I Special Closing
I_0_I_0_I Master Code 41

[344] Opening (Disarming) Reporting Codes, Access Codes 1-8
I_0_I_0_I User Code 01 I_0_I_0_I User Code 05
I_0_I_0_I User Code 02 I_0_I_0_I User Code 06
I_0_I_0_I User Code 03 I_0_I_0_I User Code 07
I_0_I_0_I User Code 04 I_0_I_0_I User Code 08

[345] Opening (Disarming) Reporting Codes, Access Codes 9-16
I_0_I_0_I User Code 09 I_0_I_0_I User Code 13
I_0_I_0_I User Code 10 I_0_I_0_I User Code 14
I_0_I_0_I User Code 11 I_0_I_0_I User Code 15
I_0_I_0_I User Code 12 I_0_I_0_I User Code 16

[346] Opening (Disarming) Reporting Codes, Access Codes 17-24
I_0_I_0_I User Code 17 I_0_I_0_I User Code 21
I_0_I_0_I User Code 18 I_0_I_0_I User Code 22
I_0_I_0_I User Code 19 I_0_I_0_I User Code 23
I_0_I_0_I User Code 20 I_0_I_0_I User Code 24

[347] Opening (Disarming) Reporting Codes, Access Codes 25-32
I_0_I_0_I Duress User 33 I_0_I_0_I Master Code 42
I_0_I_0_I Duress User 34 I_0_I_0_I Partial Closing
I_0_I_0_I Master Code 40 I_0_I_0_I Special Closing
I_0_I_0_I Master Code 41

[348] Miscellaneous Opening (Disarming) Reporting Codes
I_0_I_0_I Duress User 33 I_0_I_0_I Master Code 42
I_0_I_0_I Duress User 34 I_0_I_0_I Auto Arm Cancellation
I_0_I_0_I Master Code 40 I_0_I_0_I Special Opening
I_0_I_0_I Master Code 41

[349] Maintenance Alarm Reporting Codes
I_F_I_F_I Battery Trouble I_F_I_F_I Auxiliary Power Supply Trouble
I_F_I_F_I AC Failure Trouble I_F_I_F_I TLM Trouble (via LINKS)
I_F_I_F_I Bell Circuit Trouble I_F_I_F_I For Future Use
I_F_I_F_I Fire Trouble Alarm I_F_I_F_I General System Supervisory

[350] Maintenance Restoral Reporting Codes
I_0_I_0_I Battery Restore I_0_I_0_I Auxiliary Power Supply Restore
I_0_I_0_I AC Failure Restoral I_0_I_0_I TLM Restoral
I_0_I_0_I Bell Circuit Restoral I_0_I_0_I For Future Use
I_0_I_0_I Fire Trouble Restore I_0_I_0_I General System Supervisory Restore

[351] Miscellaneous Maintenance Reporting Codes
I_0_I_0_I Phone Number 1 Failure to Communicate Restore
I_0_I_0_I Phone Number 2 Failure to Communicate Restore
I_0_I_0_I Event Buffer is 75% Full Since Last Upload
I_0_I_0_I DLS Lead IN
I_0_I_0_I DLS Lead OUT
I_0_I_0_I General Zone Fault Alarm
I_0_I_0_I General Zone Fault Restore
I_0_I_0_I Delinquency Code

[352] Test Transmission Reporting Codes
I_F_I_F_I Periodic Test I_F_I_F_I LINKS 1000 Test Transmission Code
I_F_I_F_I System Test

[353] Wireless Maintenance Reporting Codes
I_0_I_0_I General Zone Low Batt I_0_I_0_I General Zone Low Bat Rest

[360] Communicator Format Options (Third telephone number follows format of First)
Default
02 I_0_I_4_I 1st Phone Number
01 = 4/2 20 BPS 1400 HZ 04 = SIA FSK
02 = 4/2 20 BPS 2300 HZ 05 = Pager
03 = DTMF CONTACT ID
02 I_0_I_5_I 2nd Phone Number
[361] Alarms and Restorals Call Directions
Default Option ON OFF
ON I_ON_I 1 1st Telephone Number Disabled
OFF I_OFF_I 2 2nd Telephone Number Disabled
OFF I_OFF_I 3 1st Telphone Number (LINKS) Disabled
OFF I_OFF_I 4 2nd Telephone Number (LINKS) Disabled
OFF I_OFF_I 5 to 8 for Future Use

[363] Tampers and Restorals Call Directions
Default Option ON OFF
ON I_ON_I 1 1st Telephone Number Disabled
OFF I_OFF_I 2 2nd Telephone Number Disabled
OFF I_OFF_I 3 1st Telphone Number (LINKS) Disabled
OFF I_OFF_I 4 2nd Telephone Number (LINKS) Disabled
OFF I_OFF_I 5 to 8 for Future Use

[365] Openings and Closings Call Directions
Default Option ON OFF
ON I_OFF_I 1 1st Telephone Number Disabled
OFF I_OFF_I 2 2nd Telephone Number Disabled
OFF I_OFF_I 3 1st Telphone Number (LINKS) Disabled
OFF I_OFF_I 4 2nd Telephone Number (LINKS) Disabled
OFF I_OFF_I 5 to 8 for Future Use

[367] System Maintenance Alarms and Restorals Call Directions
Default Option ON OFF
ON I_ON_I 1 1st Telephone Number Disabled
OFF I_OFF_I 2 2nd Telephone Number Disabled
OFF I_OFF_I 3 1st Telphone Number (LINKS) Disabled
OFF I_OFF_I 4 2nd Telephone Number (LINKS) Disabled
OFF I_OFF_I 5 to 8 for Future Use

[368] System Test Transmissions Call Directions
Default Option ON OFF
ON I_ON_I 1 1st Telephone Number Disabled
OFF I_OFF_I 2 2nd Telephone Number Disabled
OFF I_OFF_I 3 1st Telphone Number (LINKS) Disabled
OFF I_OFF_I 4 2nd Telephone Number (LINKS) Disabled
OFF I_OFF_I 5 to 8 for Future Use

[370] Communication Variables
Default
003 I_ _I_ _I_ _I Swinger Shutdwn (Alarms&Rest) (001-014 Trans, 000=disabled)
003 I_ _I_ _I_ _I Swinger Shutdwn (Tampers&Rest) (001-014 Trans, 000=disabled)
003 I_ _I_ _I_ _I Swinger Shutdwn (Maint&Rest) (001-014 Trans, 000=disabled)
000 I_ _I_ _I_ _I Communication Delay (001-255 seconds)
030 I_ _I_ _I_ _I AC Failure Communication Delay (001-255 minutes)
030 I_ _I_ _I_ _I TLM Trouble Delay Land Line (Number of valid checks required – 000-255 x 10s)
030 I_ _I_ _I_ _I TLM Trouble Delay Links (Number of valid checks required – 000-255 x 10s)
030 I_ _I_ _I_ _I Test Transmission Cycle (001-255 days; 000 to disable)
007 I_ _I_ _I_ _I Zone Low Battery Transmission Delay (000-255 days)
030 I_ _I_ _I_ _I Delinquency Transmission Cycle (000-255 days)

[371] Test Transmission Time of Day
Default
9999 I_ _I_ _I_ _I_ _I Valid entries are 0000 to 2359
[380] First Communicator Option Code
Default Option ON OFF
ON I_ON_I 1 Communications Enabled Disabled
OFF I_ON_I 2 Restorals on Bell Time-Out Restorals Follow Zones
OFF I_OFF_I 3 Pulse Dialing DTMF Dialing
ON I_ON_I 4 Switch to Pulse after 5th Attempt DTMF for All Attempts
OFF I_OFF_I 5 3rd Phone Number Enabled Disabled
OFF I_OFF_I 6 Alternate Dial 1st & 3rd Call 1st Number, Backup to 2nd
OFF I_OFF_I 7 Call Links as well as Land Line Links is Backup to Land Line
OFF I_OFF_I 8 Delinquency Follows Activity (Hrs) Delinquency Follows Arming (Days)

[381] Second Communicator Option Code
Default Option ON OFF
OFF I_OFF_I 1 Open after Alarm KP Ringback Enable Disabled
OFF I_OFF_I 2 Open After Bell Ringback Enable Disabled
OFF I_OFF_I 3 SIA sends Programmed Report Codes SIA sends Automatic Report Codes
OFF I_OFF_I 4 Closing Confirmation Enabled Disabled
ON I_ON_I 5 For Future Use
OFF I_OFF_I 6 For Future Use
ON I_OFF_I 7 Contact ID sends Programmed Reports Contact ID sends Automatic Reports
OFF I_OFF_I 8 For Future Use

[390] Links Preamble First Telephone Number
Default
FFFF I_ _I_ _I_ _I_ _I

[391] Links Preamble Second Telephone Number
Default
FFFF I_ _I_ _I_ _I_ _I

[392] Links Preamble Third Telephone Number
Default
FFFF I_ _I_ _I_ _I_ _I

[393] Links Special Function Preamble
Default
FFFF I_ _I_ _I_ _I_ _I

Download Programming

[401] First Downloading Option Code
Default Option ON OFF
OFF I_ON_I 1 Downloading Enabled Disabled
ON I_ON_I 2 User Can Enable DLS Window Disabled
OFF I_OFF_I 3 Call Back Enabled Disabled
OFF I_ON_I 4 User Initiated Call-Up Enabled Disabled
OFF I_OFF_I 5 to 8 For Future Use

[402] Downloading Telephone Number (32 Digits
I_L_I_E_I_A_I_V_I_E_I_ _I_B_I_L_I_A_I_N_I_K_I_ _I_ _I_ _I_ _I_ _I_ _I_ _I

[403] Downloading Access Code
Default
0580 I_0_I_5_I_8_I_0_I

[404] Panel Identification Code
Default
0580 I_0_I_5_I_8_I_0_I

[405] Answer Machine Double Call Timer
Default
060 I_0_I_3_I_0_I

[406] Number of Rings to Answer On
Default
000 I_0_I_1_I_0_I

[490] Links Preamble Download Phone Number
Default
FFFF I_F_I_F_I_F_I_F_I

[499] + Installer Code + [499] Initiate PC-Link (Local Downloading)

[701] First International Options Code (v2.3 only)
Default Option ON OFF
OFF I_ _I 1 to 4 For Future Use
OFF I_ _I 5 6-Digit User Access Codes 4-Digit User Access Codes
OFF I_ _I 6 Busy Tone Detection Enabled Disabled
OFF I_ _I 7 to 8 For Future Use
Module Programming

[801] PC5400 Printer Module CLICK HERE FOR PC5400 PROGRAMMING

[803] PC2150/2250 Long Range Radio or Skyroute CLICK HERE FOR SKYROUTE PROGRAMMING

[804] PC5132 Wireless Receiver CLICK HERE FOR PC5132 PROGRAMMING

PC5132 v3.x and below use 900Mhz sensors PC5132 v4.x and above use 433Mhz sensors

Special Installer Functions

[981] Installer Buzzer Walk Test Mode Begin/End

[902] Module Supervision Enable/Reset

[903] View Module Supervision Field

[904] Wireless Module Placement Test
Select the module / transmitter (Zones 01-32).
Press # to Cancel.
Placement Led Keypad Alpha Keypad Bell / Buzzer

Good Light 1 ON Steady GOOD 1 Beep / Squawk
Fair Light 2 ON Steady FAIR 2 Beeps / Squawks
Bad Light 3 ON Steady BAD 3 Beeps / Squawks
[990] Installer Lockout Enable

[991] Installer Lockout Disable

[993] Restore Links Long Range Radio Programming 993 + Installer Code + 993

[996] Restore PC5132 Factory Default Programming 996 + Installer Code + 996

[997] Restore PC5400 Factory Default Programming 997 + Installer Code + 997

[999] Restore Factory Default Programming 999 + Installer Code + 999

LCD Keypad Programming