*20 |
Master Code |
I_4_I_1_I_1_I_0_I |
*21 |
Quick Arm Enable |
I_1_I |
0 = No
1 = Yes
|
*22 |
Keyswitch Enable |
I_0_I |
0 = No
1 = Yes
|
*23 |
Force Bypass Enable |
I_0_I |
0 = No
1 = Yes
|
*27 |
Audible Exit Warning
(not on older FA-110C’s)
|
I_1_I |
0 = No
1 = Yes
|
*28 |
Confirmation of Arming Ding |
I_0_I |
0 = No
1 = Yes
|
*29 |
Fire Sounder No Timeout |
I_1_I |
0 = No
1 = Yes
|
*30 |
Alarm Bell Timeout |
I_2_I |
1 = 4 minutes
2 = 8 minutes
3 = 12 minutes
4 = 16 minutes
|
*31 |
Zone 1 Definition |
I_?_I |
0 = Zone Disabled
1 = Entry/Exit
2 = Not Used
3 = Instant/Perimeter
4 = Interior/PIR
5 = Trouble by Day
6 = 24 hr Silent (Holdup)
7 = 24 hr Audible (Police Panic)
8 = 24 hr Auxiliary (Medical)
9 = Fire without Timeout (Smokes)
#10 = Interior with Delay
|
*32 |
Zone 2 Definition |
I_?_I |
*33 |
Zone 3 Definition |
I_?_I |
*34 |
Zone 4 Definition |
I_?_I |
*35 |
Zone 5 Definition
(Hardwire Smokes this zone)
|
I_?_I |
*36 |
Zone 6 Definition |
I_?_I |
*37 |
Zone 7 Definition
(Panic * & #)
|
I_7_I |
*38 |
Entry Delay |
I_2_I |
Exit Delay = Entry + 15 seconds
1 = 20 seconds
2 = 30 seconds
3 = 45 seconds
4 = 60 seconds
5 = 90 seconds
|
*39 |
Zone 3 Response to open |
I_0_I |
0 = 400ms
1 = 10ms
|
*40 |
PABX Access Code |
I_ _I_ _I_ _I_ _I |
(If 9 is needed to dial add here) |
*41 |
Primary Phone
(12 digits)
|
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
End Phone with * # + 11 = * # + 12 = # # + 13 = 2.5 second pause
|
*42 |
Secondary Phone |
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
Pager only available on VERY new 4110-DL’s,
pager will not work if Account starts with 0
|
*43 |
Subscriber Account |
I_ _I_ _I_ _I_ _I
Hex A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15
|
*44 |
Report Format |
I_7_I |
0 = 3/1, 4/1 Ademco L/S Standard
1 = 3/1, 4/1 Radionics Standard
2 = 4/2 Ademco L/S Standard
3 = 4/2 Radionics Standard
6 = 4/2 Ademco Express
7 = Contact ID
8 = 3/1, 4/1 Ademco L/S Expanded
9 = 3/1, 4/1 Radionics Expanded
|
*45 |
Phone System Select |
I_3_I |
0 = Pulse Dial
1 = DTMF Dial
2 = Pulse Dial, CS on Watts Line
3 = DTMF Dial, CS on Watts Line
|
*46 |
Sescoa/Radionics Select |
I_0_I |
0 = Radionics
1 = Sescoa
|
*47 |
15 Sec Burg Dial Delay |
I_0_I |
0 = No
1 = Yes
|
*48 |
Periodic Test Message |
I_0_I |
0 = None
1 = 24 Hours
2=Weekly
|
*49 |
Split/Dual Reporting |
I_0_I |
|
To Primary Phone |
To Secondary Phone |
0 = All Reports |
Backup Only |
1 = Alarms, Restore, Cancel |
All Other Reports |
2 = All Reports except Open/Close, Test |
Open/Close, Test |
3 = Alarms, Restore, Cancel |
All Reports |
4 = All Reports except Open/Close, Test |
All Reports |
5 = All Reports (Dual Reporting) |
All Reports |
|
*50 |
Keypad Medical/Fire |
1 & * |
I_1_I |
(Silent, sends 95) |
|
3 & # |
I_1_I |
(Audible, sends 96) |
(This section may not be available on older models, display will show EE)
|
*51 |
Zone 1 Report Code |
I_1_I_0_I |
*52 |
Zone 2 Report Code |
I_1_I_0_I |
*53 |
Zone 3 Report Code |
I_1_I_0_I |
*54 |
Zone 4 Report Code |
I_1_I_0_I |
*55 |
Zone 5 Report Code |
I_1_I_0_I |
*56 |
Zone 6 Report Code |
I_1_I_0_I |
*57 |
Zone 7 Police Panic Report Code |
I_1_I_0_I |
*58 |
Zone 8 Duress Report Code |
I_1_I_0_I |
*59 |
Zone 9 Tamper Report Code |
I_0_I_0_I |
*60 |
Trouble Report Code |
I_1_I_0_I |
(Fire Trouble) |
*61 |
Bypass Report Code |
I_0_I_0_I |
*62 |
AC Loss Report Code |
I_1_I_0_I |
*63 |
Low Bat Report Code |
I_1_I_0_I |
*64 |
Test Report Code |
I_0_I_0_I |
*65 |
Open Report Code |
I_0_I |
*66 |
Close Report Code |
I_0_I |
*68 |
Cancel Report Code |
I_1_I_0_I |
*69 |
Group Restores Trouble/Bypass |
I_0_I |
*70 |
Alarm Restore Code |
I_0_I |
*71 |
Trouble Restore Code |
I_0_I_0_I |
*72 |
Bypass Restore Code |
I_0_I_0_I |
*73 |
AC Restore Code |
I_0_I_0_I |
*74 |
Low Bat Rest Code |
I_0_I_0_I |
*93 |
Reports Per Armed Period |
I_0_I |
0 = 10 Reports
1 = Unlimited
|
*94 |
Download Phone Number |
I_1_I_8_I_0_I_0_I_6_I_8_I_2_I_1_I_6_I_9_I_0_I_ _I |
*95 |
Ring Count |
I_# 15_I |
0 to #15 (#15 = Answer Machine) |
*96 |
Reinitialize Download |
(No Value needed, keypad will just beep) |
*97 |
Default Panel |
(No Value needed, keypad will beep and default panel) |
*98 |
Exits Program Mode |
(Will not allow re-entry with Installer Code + 8 + 0 + 0) |
*99 |
Exits Program Mode |
(Will allow re-entry with Code + 8 + 0 + 0)
|