AREA 1 |
LOC |
FEATURE |
DEFAULT |
OPTIONS |
1 |
Away Exit Delay Time |
I_60_I |
0 to 255 Seconds |
2 |
Stay/Night Exit Delay Time |
I_60_I |
0 to 255 Seconds |
3 |
Entry Delay 1 Time |
I_20_I |
0 to 255 Seconds |
4 |
Entry Delay 2 Time |
I_40_I |
0 to 255 Seconds |
5 |
Pre-Alarm Time |
I_0_I |
0 to 255 Seconds
|
6 |
B Key (Police) Alarm Output |
I_2_I |
0 = No Sounder Output |
7 |
C Key (Medical) Alarm Output |
I_1_I |
1 = Keypad Sounder Only
2 = Keypad Sounder + Bell Output
|
8 |
Closing Bell Ringback |
I_0_I |
0 = Ringback Output
1 = Ringback Output and Keypads
2 = Ringback Output, Bell & Keypads
|
9 |
Burglar Audible Lockout |
I_0_I |
0 to 15 Alarms for Area (0 = Disabled) |
10 |
Swinger Shunt |
I_0_I |
0 to 15 Zone Violations (0 = Disabled) |
11 |
Area Attributes (see below) |
I_09_I |
(Don’t worry about this section)
|
First Digit |
0 |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
A |
B |
C |
D |
E |
F |
All Features Below Disabled |
* |
Two Button Arm |
|
* |
|
* |
|
* |
|
* |
|
* |
|
* |
|
* |
|
* |
Double Button Press Arm |
|
|
* |
* |
|
|
* |
* |
|
|
* |
* |
|
|
* |
* |
Open After Alarm |
|
|
|
|
* |
* |
* |
* |
|
|
|
|
* |
* |
* |
* |
Display Bypassed Armed |
|
|
|
|
|
|
|
|
* |
* |
* |
* |
* |
* |
* |
*
|
Second Digit |
0 |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
A |
B |
C |
D |
E |
F |
Double Press Panic Keys |
* |
* |
* |
* |
* |
* |
* |
* |
Bypass |
|
* |
|
* |
|
* |
|
* |
|
* |
|
* |
|
* |
|
* |
Force-Arm |
|
|
* |
* |
|
|
* |
* |
|
|
* |
* |
|
|
* |
* |
Exit Arm |
|
|
|
|
* |
* |
* |
* |
|
|
|
|
* |
* |
* |
* |
3 Second Panic Keys |
|
|
|
|
|
|
|
|
* |
* |
* |
* |
* |
* |
* |
* |
|
AREA 2 |
12 |
Away Exit Delay Time |
I_60_I |
0 to 255 Seconds |
13 |
Stay/Night Exit Delay Time |
I_60_I |
0 to 255 Seconds |
14 |
Entry Delay 1 Time |
I_20_I |
0 to 255 Seconds |
15 |
Entry Delay 2 Time |
I_40_I |
0 to 255 Seconds |
16 |
Pre-Alarm Time |
I_0_I |
0 to 255 Seconds
|
17 |
B Key (Police) Alarm Output |
I_2_I |
0 = No Sounder Output |
18 |
C Key (Medical) Alarm Output |
I_1_I |
1 = Keypad Sounder Only
2 = Keypad Sounder + Bell Output
|
19 |
Closing Ringback |
I_0_I |
20 |
Burglar Audible Lockout |
I_0_I |
21 |
Swinger Shunt |
I_0_I |
22 |
Area Attributes |
I_09_I
|
Loc |
Keypad Attributes |
Default |
23 |
Keypad 1 LED |
I_1C_I |
24 |
|
I_5_I
|
25 |
Keypad 2 LED |
I_1C_I |
26 |
|
I_5_I
|
27 |
Keypad 3 SSD |
I_1C_I |
28 |
|
I_5_I
|
29 |
Keypad 4 SSD |
I_1C_I |
30 |
|
I_5_I
|
31 |
Keypad 5 LCD/VFD |
I_1C_I |
32 |
|
I_5_I
|
33 |
Keypad 6 LCD/VFD |
I_1E_I |
34 |
|
I_5_I |
First Digit |
0 |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
A |
B |
C |
D |
E |
F |
All Features Below Disabled |
* |
C (Medical) Key Enabled |
|
* |
|
* |
|
* |
|
* |
|
* |
|
* |
|
* |
|
* |
Silent Exit Time |
|
|
* |
* |
|
|
* |
* |
|
|
* |
* |
|
|
* |
* |
Silent Entry Time |
|
|
|
|
* |
* |
* |
* |
|
|
|
|
* |
* |
* |
* |
Silent Troubles |
|
|
|
|
|
|
|
|
* |
* |
* |
* |
* |
* |
* |
*
|
Second Digit |
0 |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
A |
B |
C |
D |
E |
F |
Primary Area 1 |
* |
|
|
|
* |
|
|
|
* |
|
|
|
* |
Primary Area 2 |
|
* |
|
|
|
* |
|
|
|
* |
|
|
|
* |
Primary Area 1, Secondary Area 2 |
|
|
* |
|
|
|
* |
|
|
|
* |
|
|
|
* |
Primary Area 2, Secondary Area 1 |
|
|
|
* |
|
|
|
* |
|
|
|
* |
|
|
|
* |
A Key (Fire) Enabled |
|
|
|
|
* |
* |
* |
* |
|
|
|
|
* |
* |
* |
* |
B Key (Police) Enabled |
|
|
|
|
|
|
|
|
* |
* |
* |
* |
* |
* |
* |
* |
|
|
Zone Type |
Area |
Expansion
Zone
|
Burg Zn
Attribute
|
Zone
Attribute
|
|
Loc |
Default |
Loc |
Default |
Loc |
Default |
Loc |
Default |
Loc |
Default |
Zone 01 |
35 |
I_1_I |
36 |
I_1_I |
|
|
37 |
I_0D_I |
38 |
I_37_I |
Zone 02 |
39 |
I_1_I |
40 |
I_1_I |
|
|
41 |
I_03_I |
42 |
I_37_I |
Zone 03 |
43 |
I_1_I |
44 |
I_1_I |
|
|
45 |
I_03_I |
46 |
I_37_I |
Zone 04 |
47 |
I_1_I |
48 |
I_1_I |
|
|
49 |
I_0C_I |
50 |
I_37_I |
Zone 05 |
51 |
I_1_I |
52 |
I_1_I |
|
|
53 |
I_0C_I |
54 |
I_37_I |
Zone 06 |
55 |
I_1_I |
56 |
I_1_I |
|
|
57 |
I_0C_I |
58 |
I_37_I |
Zone 07 |
59 |
I_1_I |
60 |
I_1_I |
|
|
61 |
I_0C_I |
62 |
I_37_I |
Zone 08 |
63 |
I_1_I |
64 |
I_1_I |
|
|
65 |
I_0C_I |
66 |
I_37_I |
Zone 09 |
67 |
I_1_I |
68 |
I_1_I |
|
|
69 |
I_0C_I |
70 |
I_37_I |
Zone 10 |
71 |
I_1_I |
72 |
I_1_I |
|
|
73 |
I_0C_I |
74 |
I_37_I |
Zone 11 |
75 |
I_1_I |
76 |
I_1_I |
|
|
77 |
I_0C_I |
78 |
I_37_I |
Zone 12 |
79 |
I_1_I |
80 |
I_1_I |
|
|
81 |
I_0C_I |
82 |
I_37_I |
Zone 13 |
83 |
I_1_I |
84 |
I_0_I |
85 |
I_0_I |
86 |
I_0C_I |
87 |
I_37_I |
Zone 14 |
88 |
I_1_I |
89 |
I_0_I |
90 |
I_0_I |
91 |
I_0C_I |
92 |
I_37_I |
Zone 15 |
93 |
I_1_I |
94 |
I_0_I |
95 |
I_0_I |
96 |
I_0C_I |
97 |
I_37_I |
Zone 16 |
98 |
I_1_I |
99 |
I_0_I |
100 |
I_0_I |
101 |
I_0C_I |
102 |
I_37_I |
Zone 17 |
103 |
I_1_I |
104 |
I_0_I |
105 |
I_0_I |
106 |
I_0C_I |
107 |
I_37_I |
Zone 18 |
108 |
I_1_I |
109 |
I_0_I |
110 |
I_0_I |
111 |
I_0C_I |
112 |
I_37_I |
Zone 19 |
113 |
I_1_I |
114 |
I_0_I |
115 |
I_0_I |
116 |
I_0C_I |
117 |
I_37_I |
Zone 20 |
118 |
I_1_I |
119 |
I_0_I |
120 |
I_0_I |
121 |
I_0C_I |
122 |
I_37_I |
Zone 21 |
123 |
I_1_I |
124 |
I_0_I |
125 |
I_0_I |
126 |
I_0C_I |
127 |
I_37_I |
Zone 22 |
128 |
I_1_I |
129 |
I_0_I |
130 |
I_0_I |
131 |
I_0C_I |
132 |
I_37_I |
Zone 23 |
133 |
I_1_I |
134 |
I_0_I |
135 |
I_0_I |
136 |
I_0C_I |
137 |
I_37_I |
Zone 24 |
138 |
I_1_I |
139 |
I_0_I |
140 |
I_0_I |
141 |
I_0C_I |
142 |
I_37_I |
Zone 25 |
143 |
I_1_I |
144 |
I_0_I |
145 |
I_0_I |
146 |
I_0C_I |
147 |
I_37_I |
Zone 26 |
148 |
I_1_I |
149 |
I_0_I |
150 |
I_0_I |
151 |
I_0C_I |
152 |
I_37_I |
Zone 27 |
153 |
I_1_I |
154 |
I_0_I |
155 |
I_0_I |
156 |
I_0C_I |
157 |
I_37_I |
Zone 28 |
158 |
I_1_I |
159 |
I_0_I |
160 |
I_0_I |
161 |
I_0C_I |
162 |
I_37_I |
Zone 29* |
163 |
I_0_I |
|
|
|
|
|
|
164 |
I_63_I |
Zone 30** |
165 |
I_2_I |
|
|
|
|
|
|
166 |
I_63_I |
* Zone 29 is the 2-Wire Smoke Zone on Expander Module
** Zone 30 is the 2-Wire Smoke Zone on the Control Board
|
|
Zone Type |
Area |
Expansion |
0 |
= Not Used |
0 |
= Disable |
0 |
= ZXEXP Zone |
1 |
= Burglar |
1 |
= Area 1 |
1 |
= RF Gateway 1 Zone |
2 |
= 24 Hr Fire |
2 |
= Area 2 |
2 |
= RF Gateway 2 Zone |
3 |
= 24 Hr Holdup |
|
|
3 |
= ZEM Zone |
4 |
= 24 Hr Auxiliary |
5 |
= Momentary Keyswitch
(ARM AWAY/Disarm)
|
Burg Zn Attribute |
|
|
1st Digit |
2nd Digit |
6 |
= 24 Hr Communicator |
0 |
= Standard Zone |
D |
= Delay 1 |
7 |
= 24 Hr Burglar Tamper |
1 |
= Chime Always |
C |
= Instant |
8 |
= Universal |
|
|
3 |
= Interior/Follower |
9 |
= Universal Logged |
Zone Attribute |
10 |
= Verified Fire |
1st Digit |
2nd Digit |
11 |
= Fire Supervisory |
1 |
= No EOL |
12 |
= Listen-In Module Input |
3 |
= EOL |
|
USER CODE SETTINGS |
|
USER CODE |
AUTHORITY LEVEL |
AREA |
User |
Default |
Loc |
Default |
|
Loc |
Default |
User 01 |
I_1_I_2_I_3_I_4_I |
167 |
I_10_I |
3 = Arm Only |
168 |
I_1_I |
0 = Disabled |
User 02 |
I_0_I_0_I_0_I_0_I |
169 |
I_6_I |
6 = Standard |
170 |
I_1_I |
1 = Area 1 |
User 03 |
I_0_I_0_I_0_I_0_I |
171 |
I_6_I |
10 = Master |
172 |
I_1_I |
2 = Area 2 |
User 04 |
I_0_I_0_I_0_I_0_I |
173 |
I_6_I |
13 = Duress |
174 |
I_1_I |
3 = Both |
User 05 |
I_0_I_0_I_0_I_0_I |
175 |
I_6_I |
|
176 |
I_1_I |
User 06 |
I_0_I_0_I_0_I_0_I |
177 |
I_6_I |
|
178 |
I_1_I |
User 07 |
I_0_I_0_I_0_I_0_I |
179 |
I_6_I |
|
180 |
I_1_I |
User 08 |
I_0_I_0_I_0_I_0_I |
181 |
I_6_I |
|
182 |
I_1_I |
User 09 |
I_0_I_0_I_0_I_0_I |
183 |
I_6_I |
|
184 |
I_1_I |
User 10 |
I_0_I_0_I_0_I_0_I |
185 |
I_6_I |
|
186 |
I_1_I |
User 11 |
I_0_I_0_I_0_I_0_I |
187 |
I_6_I |
|
188 |
I_1_I |
User 12 |
I_0_I_0_I_0_I_0_I |
189 |
I_6_I |
|
190 |
I_1_I |
User 13 |
I_0_I_0_I_0_I_0_I |
191 |
I_6_I |
|
192 |
I_1_I |
User 14 |
I_0_I_0_I_0_I_0_I |
193 |
I_6_I |
|
194 |
I_1_I |
User 15 |
I_0_I_0_I_0_I_0_I |
195 |
I_6_I |
|
196 |
I_1_I |
User 16 |
I_0_I_0_I_0_I_0_I |
197 |
I_6_I |
|
198 |
I_1_I |
User 17 |
I_0_I_0_I_0_I_0_I |
199 |
I_6_I |
|
200 |
I_1_I |
User 18 |
I_0_I_0_I_0_I_0_I |
201 |
I_6_I |
|
202 |
I_1_I |
User 19 |
I_0_I_0_I_0_I_0_I |
203 |
I_6_I |
|
204 |
I_1_I |
User 20 |
I_0_I_0_I_0_I_0_I |
205 |
I_6_I |
|
206 |
I_1_I |
User 21 |
I_0_I_0_I_0_I_0_I |
207 |
I_6_I |
|
208 |
I_1_I |
User 22 |
I_0_I_0_I_0_I_0_I |
209 |
I_6_I |
|
210 |
I_1_I |
User 23 |
I_0_I_0_I_0_I_0_I |
211 |
I_6_I |
|
212 |
I_1_I |
User 24 |
I_0_I_0_I_0_I_0_I |
213 |
I_6_I |
|
214 |
I_1_I |
User 25 |
I_0_I_0_I_0_I_0_I |
215 |
I_6_I |
|
216 |
I_1_I |
User 26 |
I_0_I_0_I_0_I_0_I |
217 |
I_6_I |
|
218 |
I_1_I |
User 27 |
I_0_I_0_I_0_I_0_I |
219 |
I_6_I |
|
220 |
I_1_I |
User 28 |
I_0_I_0_I_0_I_0_I |
221 |
I_6_I |
|
222 |
I_1_I |
User 29 |
I_0_I_0_I_0_I_0_I |
223 |
I_6_I |
|
224 |
I_1_I |
User 30 |
I_0_I_0_I_0_I_0_I |
225 |
I_6_I |
|
226 |
I_1_I |
User 31 |
I_0_I_0_I_0_I_0_I |
227 |
I_6_I |
|
228 |
I_1_I |
User 32 |
I_0_I_0_I_0_I_0_I |
229 |
I_6_I |
|
230 |
I_1_I |
User 33 |
I_0_I_0_I_0_I_0_I |
231 |
I_6_I |
|
232 |
I_1_I |
User 34 |
I_0_I_0_I_0_I_0_I |
233 |
I_6_I |
|
234 |
I_1_I |
User 35 |
I_0_I_0_I_0_I_0_I |
235 |
I_6_I |
|
236 |
I_1_I |
User 36 |
I_0_I_0_I_0_I_0_I |
237 |
I_6_I |
|
238 |
I_1_I |
User 37 |
I_0_I_0_I_0_I_0_I |
239 |
I_6_I |
|
240 |
I_1_I |
User 38 |
I_0_I_0_I_0_I_0_I |
241 |
I_6_I |
|
242 |
I_1_I |
User 39 |
I_0_I_0_I_0_I_0_I |
243 |
I_6_I |
|
244 |
I_1_I |
User 40 |
I_0_I_0_I_0_I_0_I |
245 |
I_6_I |
|
246 |
I_1_I |
User 41 |
I_0_I_0_I_0_I_0_I |
247 |
I_6_I |
|
248 |
I_1_I |
User 42 |
I_0_I_0_I_0_I_0_I |
249 |
I_6_I |
|
250 |
I_1_I |
User 43 |
I_0_I_0_I_0_I_0_I |
251 |
I_6_I |
|
252 |
I_1_I |
User 44 |
I_0_I_0_I_0_I_0_I |
253 |
I_6_I |
|
254 |
I_1_I |
User 45 |
I_0_I_0_I_0_I_0_I |
255 |
I_6_I |
|
256 |
I_1_I |
User 46 |
I_0_I_0_I_0_I_0_I |
257 |
I_6_I |
|
258 |
I_1_I |
User 47 |
I_0_I_0_I_0_I_0_I |
259 |
I_6_I |
|
260 |
I_1_I |
User 48 |
I_0_I_0_I_0_I_0_I |
261 |
I_6_I |
|
262 |
I_1_I |
User 49 |
I_0_I_0_I_0_I_0_I |
263 |
I_6_I |
|
264 |
I_1_I |
User 50 |
I_0_I_0_I_0_I_0_I |
265 |
I_10_I |
|
266 |
I_3_I |
|
OUTPUTS DEFAULT |
268 |
Output 01 (see wire diagram) |
I_1_I |
(use 28 if trigger for 2-way) |
|
0 |
= Not Used |
19 |
= Exit Time |
1 |
= Fire Alarm |
20 |
= Entry Time |
2 |
= Fire Supervisory |
21 |
= Pre-Alarm Warning Time |
3 |
= Duress |
22 |
= Annunciation |
4 |
= Low Battery |
23 |
= Auto-Arm Warning |
5 |
= Failed to Comm |
24 |
= Closing Ringback |
6 |
= Telco Line Fault |
25 |
= Trouble |
7 |
= Telco Line Seized |
26 |
= Chime |
8 |
= Ground Start |
27 |
= Universal |
9 |
= Burglar Alarm |
28 |
= Listen-In Module Output |
10 |
= Hold-up Alarm |
29 |
= Lamp Trigger |
11 |
= Auxiliary Alarm |
30 |
= Key 4 Output |
12 |
= Bell Output Trigger |
31 |
= Key 5 Output |
13 |
= Violation |
32 |
= Key 6 Output |
14 |
= Ready |
33 |
= RF Annunciator |
15 |
= Armed AWAY |
34 |
= Access by Keypad |
16 |
= Armed STAY |
35 |
= Quick Access by Keypad |
17 |
= Armed NIGHT |
101 –
130
|
= Zone (1 to 30) Violated |
18 |
= Armed and Exit Time Expired |
201 –
230
|
= Zone (1 to 30) In Alarm or Senior Watch |
|
269 |
Output 01 area of operation |
I_1_I |
(use 3 if 2-way)
1 |
= Area 1 |
(for Output Conditions 34 & 35) |
2 |
= Area 2 |
1 |
= Control Station 1 |
3 |
= Both |
2 |
= Control Station 2 |
|
4 |
= Control Station 3 |
|
8 |
= Control Station 4 |
|
16 |
= Control Station 5 |
|
32 |
= Control Station 6 |
|
MISC. sYSTEM FUNCTIONS |
310 |
Fire Cutoff Time |
I_0_I |
0 to 255 Min (0 = No Cutoff) |
311 |
Burglar Cutoff Time |
I_10_I |
0 to 255 Min (0 = No Cutoff) |
312 |
Holdup Cutoff Time |
I_10_I |
0 to 255 Min (0 = No Cutoff) |
313 |
Aux Cutoff Time |
I_10_I |
0 to 255 Min (0 = No Cutoff) |
314 |
Universal Output Time |
I_0_I |
0 to 255 Sec (0 = Toggle ON) |
315 |
Delay Before Dial |
I_0_I |
0 to 255 Sec (0 = No Delay) |
316 |
Fire Delay Before Dial |
I_0_I |
0 to 255 Sec (0 = No Delay) |
317 |
AC Failure Delay |
I_30_I |
0 to 255 Min |
318 |
Senior Watch Time (Delinquency) |
I_24_I |
0 to 42 Hrs |
319 |
System Attributes |
I_31_I |
00 to FF |
320 |
Passcode Attempts |
I_8_I |
1 to 15 Attempts (0 = No Lock) |
321 |
AC Cycles |
I_0_I |
0 = 60Hz, 1 = 50Hz
|
RECEIVER PHONE PROGRAMMING |
322 |
Enable Communicator |
I_1_I |
0 = No, 1 = Yes |
323 |
Enable Skip Test |
I_0_I |
0 = No, 1 = Yes |
324 |
Power-Up Comm Test |
I_0_I |
0 = No, 1 = Yes |
325 |
Disable Call Waiting |
I_0_I |
0 = No, 1 = Yes |
323-327 |
Comm Test Time of Day (hr:min) |
00:00 |
00:00 to 23:59 |
328 |
Days Between Communicator Tests |
I_0_I |
0 to 255 Days (0 = Disable) |
329 |
Time between Calls |
I_5_I |
0 to 255 Seconds
|
330 |
T1 Transmission Format |
I_3_I |
0 = Pulsed 20 Baud, Non-Extended |
331 |
T2 Transmission Format |
I_3_I |
1 = Pulsed 20 Baud, Extended
2 = Pulsed 40 Baud Extended
3 = Contact ID
4 = Pager (T2 Phone Only)
|
332 |
Dialer Type |
I_1_I |
0 = Pulse, 1 = Tone, 2 = Euro Pulse |
333 |
T1 Dial Attempts |
I_5_I |
1 to 15 Attempts |
334 |
T2 Dial Attempts |
I_5_I |
1 to 15 Attempts |
335 |
On-Hook Time |
I_5_I |
1 to 15 Seconds |
336 |
Off-Hook Time |
I_3_I |
1 to 15 Seconds
|
337-352 |
Telephone 1 Number (Up to 16 Digits, Default = FFFFF)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
(A = 0 in Phone number B (11) = * C (12) = # D or E (14) = 3 Second Pause F (15) = End Phone Number)
|
353-376 |
Telephone 2 Number (Up to 24 Digits, Default = FFFFF)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
|
377-392 |
RPM (Download) Phone Number (Up to 16 Digits, Default = FFFFF)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
|
393-398 |
Area 1 Account 1 |
I_ _I_ _I_ _I_ _I_ _I_ _I (000000-FFFFFF) |
399-404 |
Area 1 Account 2 |
I_ _I_ _I_ _I_ _I_ _I_ _I (000000-FFFFFF)
(Enter A for 0’s)
|
|
Hex Program 10 = A 11 = B 12 = C 13 = D 14 = E 15 = F
|
405-410 |
Area 2 Account 1 |
I_ _I_ _I_ _I_ _I_ _I_ _I (000000-FFFFFF) |
411-416 |
Area 2 Account 2 |
I_ _I_ _I_ _I_ _I_ _I_ _I (000000-FFFFFF)
|
417 |
Fire Alarm Call Direction |
I_3_I |
0 = Do Not Report |
418 |
System Events Call Direction |
I_0_I |
1 = Phone 1 Only |
419 |
Burglar Alarm Call Direction |
I_3_I |
2 = Phone 2 Only |
420 |
Hold Up Alarm Call Direction |
I_3_I |
3 = Phone 1 (2 on Failure) |
421 |
Auxiliary Alarm Call Direction |
I_3_I |
4 = Phone 2 (1 on Failure) |
422 |
Critical Condition Call Direction |
I_3_I |
5 = Phone 1 and 2 |
423 |
Zone Trouble/Restore Call Direction |
I_0_I |
424 |
Zone bypass/Restore Call Direction |
I_0_I |
425 |
Open/Close Call Direction |
I_0_I |
426 |
Supervision Call Direction |
I_0_I
|
AREA 2 Phone Call Directions |
427 |
Burglar Alarm Call Direction |
I_3_I |
2 = Phone 2 Only |
428 |
Hold Up Alarm Call Direction |
I_3_I |
3 = Phone 1 (2 on Failure) |
429 |
Aux Panic Alarm Call Direction |
I_3_I |
4 = Phone 2 (1 on Failure) |
430 |
Critical Condition Call Direction |
I_3_I |
5 = Phone 1 and 2 |
431 |
Zone Trouble/Restore Call Direction |
I_0_I |
432 |
Zone Bypass/Restore Call Direction |
I_0_I |
433 |
Open/Close Call Direction |
I_0_I |
434 |
Supervision Call Direction |
I_0_I
|
ZONE REPORT CODES |
|
ALARM |
RESTORE |
BYPASS |
TROUBLE |
|
Loc |
Default |
Loc |
Default |
Loc |
Default |
Loc |
Default |
ZONE 01 |
435 |
I_31_I |
436 |
I_E3_I |
437 |
I_AB_I |
438 |
I_F3_I |
ZONE 02 |
439 |
I_32_I |
440 |
I_E3_I |
441 |
I_AB_I |
442 |
I_F3_I |
ZONE 03 |
443 |
I_33_I |
444 |
I_E3_I |
445 |
I_AB_I |
446 |
I_F3_I |
ZONE 04 |
447 |
I_34_I |
448 |
I_E3_I |
449 |
I_AB_I |
450 |
I_F3_I |
ZONE 05 |
451 |
I_35_I |
452 |
I_E3_I |
453 |
I_AB_I |
454 |
I_F3_I |
ZONE 06 |
455 |
I_36_I |
456 |
I_E3_I |
457 |
I_AB_I |
458 |
I_F3_I |
ZONE 07 |
459 |
I_37_I |
460 |
I_E3_I |
461 |
I_AB_I |
462 |
I_F3_I |
ZONE 08 |
463 |
I_38_I |
464 |
I_E3_I |
465 |
I_AB_I |
466 |
I_F3_I |
ZONE 09 |
467 |
I_39_I |
468 |
I_E3_I |
467 |
I_AB_I |
468 |
I_F3_I |
ZONE 10 |
471 |
I_3A_I |
472 |
I_E3_I |
473 |
I_AB_I |
474 |
I_F3_I |
ZONE 11 |
475 |
I_3B_I |
476 |
I_E3_I |
477 |
I_AB_I |
478 |
I_F3_I |
ZONE 12 |
479 |
I_3C_I |
480 |
I_E3_I |
481 |
I_AB_I |
482 |
I_F3_I |
ZONE 13 |
483 |
I_3D_I |
484 |
I_E3_I |
485 |
I_AB_I |
486 |
I_F3_I |
ZONE 14 |
487 |
I_3E_I |
488 |
I_E3_I |
489 |
I_AB_I |
490 |
I_F3_I |
ZONE 15 |
491 |
I_3F_I |
492 |
I_E3_I |
493 |
I_AB_I |
494 |
I_F3_I |
ZONE 16 |
495 |
I_61_I |
496 |
I_E6_I |
497 |
I_AB_I |
498 |
I_F6_I |
ZONE 17 |
499 |
I_62_I |
500 |
I_E6_I |
501 |
I_AB_I |
502 |
I_F6_I |
ZONE 18 |
503 |
I_63_I |
504 |
I_E6_I |
505 |
I_AB_I |
506 |
I_F6_I |
ZONE 19 |
507 |
I_64_I |
508 |
I_E6_I |
509 |
I_AB_I |
510 |
I_F6_I |
ZONE 20 |
511 |
I_65_I |
512 |
I_E6_I |
513 |
I_AB_I |
514 |
I_F6_I |
ZONE 21 |
515 |
I_66_I |
516 |
I_E6_I |
517 |
I_AB_I |
518 |
I_F6_I |
ZONE 22 |
519 |
I_67_I |
520 |
I_E6_I |
521 |
I_AB_I |
522 |
I_F6_I |
ZONE 23 |
523 |
I_68_I |
524 |
I_E6_I |
525 |
I_AB_I |
526 |
I_F6_I |
ZONE 24 |
527 |
I_69_I |
528 |
I_E6_I |
529 |
I_AB_I |
530 |
I_F6_I |
ZONE 25 |
531 |
I_6A_I |
532 |
I_E6_I |
533 |
I_AB_I |
534 |
I_F6_I |
ZONE 26 |
535 |
I_6B_I |
536 |
I_E6_I |
537 |
I_AB_I |
538 |
I_F6_I |
ZONE 27 |
539 |
I_6C_I |
540 |
I_E6_I |
541 |
I_AB_I |
542 |
I_F6_I |
ZONE 28 |
543 |
I_6D_I |
544 |
I_E6_I |
545 |
I_AB_I |
546 |
I_F6_I |
ZONE 29 |
547 |
I_11_I |
548 |
I_E1_I |
549 |
I_AB_I |
550 |
I_F1_I |
ZONE 30 |
551 |
I_12_I |
552 |
I_E1_I |
553 |
I_AB_I |
554 |
I_F1_I |
|
SYSTEM REPORT CODES |
655 |
A Key (Fire) Report Code |
I_19_I |
656 |
B Key (Police) Report Code |
I_29_I |
657 |
C Key (Medical) Report Code |
I_49_I |
658 |
Duress Report Code |
I_99_I |
659 |
Keypad Lockout Report Code |
I_00_I |
660 |
Burg Cancel Report Code |
I_00_I |
661 |
Quick Arm Report Code |
I_00_I |
662 |
Auto Arm Report Code |
I_00_I |
663 |
Auto Arm Failed Report Code |
I_00_I |
664 |
Keyswitch Close Rep Code |
I_00_I |
665 |
Keyswitch Open Rep Code |
I_00_I |
666 |
Download Closing Rep Code |
I_00_I |
667 |
Download Opening Rep Code |
I_00_I |
668 |
Closing Extended Code |
I_00_I |
669 |
Exit Alarm Report Code |
I_00_I |
670 |
Recent Closing Report Code |
I_00_I |
671 |
Latchkey Supervisory Code |
I_00_I |
672 |
User On-Premise Code |
I_00_I |
673 |
Com Test Not Normal Code |
I_00_I |
674 |
Comm Test Report Code |
I_00_I |
675 |
AC Fail Report Code |
I_FA_I |
676 |
AC Restore Report Code |
I_00_I |
677 |
Low Battery Report Code |
I_F9_I |
678 |
Battery Restore Report Code |
I_00_I |
679 |
Bell Fault Report Code |
I_00_I |
680 |
Bell Restore Report Code |
I_00_I |
681 |
Comm Restore Report Code |
I_00_I |
682 |
Memory Error Report Code |
I_00_I |
683 |
Local Program Begin Code |
I_00_I |
684 |
Local Program End Code |
I_00_I |
685 |
RPM End Report Code |
I_00_I |
686 |
RPM Denied Report Code |
I_00_I |
687 |
RPM Abort Report Code |
I_00_I |
688 |
Missing Keypad Rep Code |
I_00_I |
689 |
Restore Keypad Rep Code |
I_00_I |
690 |
RF Jamming Rep Code |
I_00_I |
691 |
RF Channel Clear Rep Code |
I_00_I |
692 |
Keyfob Low Battery Rep Code |
I_00_I
|
INSTALLER STUFF |
759-762 |
Installer Passcode |
I_9_I_6_I_3_I_2_I 0000 TO 9999 |
763 |
Call 2 Timer (Double Call Timer) |
I_0_I |
0 to 255 seconds |
764 |
Auto Answer Ring Count |
I_5_I |
0 to 15 Rings |
765 |
Enable RPM (Download) |
I_1_I |
0 = No, 1 = Yes |
766 |
Enable Power-Up Programming |
I_0_I |
0 = No, 1 = Yes |
767 |
Lockout Local Programming |
I_0_I |
0 = No, 1 = Yes |