Formats Contact ID or 4/2 (Contact ID preferred)
Enter Program 9 + 9632 + 3 or power down & up and press 9 then 9999 in 60 seconds
Options 9 + Installer Code + 1 = Answer Download Request
9 + Installer Code + 2 = Future Use
9 + Installer Code + 3 = Enter Installer Programming
9 + Installer Code + 4 = Future Use
9 + Installer Code + 5 = Program User Codes
9 + Installer Code + 6 = Reset to Factory Defaults
9 + Installer Code + 7 = Set Hours until next Communicator Test
9 + Installer Code + 8 = Call Download Computer
9 + Installer Code + 9 = Program RF Sensors
Move to
Location
3-Digit Location + ENTER
Enter Data 1 to 3 digit Value + ENTER to save and ENTER again to move to next
(To program phone use 1 ENTER ENTER 8 ENTER ENTER 0 ENTER ENTER etc)
ENTER Key Saves new value in a Location
If no new value is entered in a Location will move to next Location
CLEAR Key If pressed in Location after entering new value erases and reverts to old values
If pressed in Location and no new values entered will exit to top program level
MEDICAL Panic Moves to previous Program Location
OFF/CANCEL Press and hold to display current programming in Location
Exit Program Press CLEAR twice
Hex Program 10 = A, 11 = B, 12 = C, 13 = D, 14 = E, 15 = F

AREA 1
LOC FEATURE DEFAULT OPTIONS
1 Away Exit Delay Time I_60_I 0 to 255 Seconds
2 Stay/Night Exit Delay Time I_60_I 0 to 255 Seconds
3 Entry Delay 1 Time I_20_I 0 to 255 Seconds
4 Entry Delay 2 Time I_40_I 0 to 255 Seconds
5 Pre-Alarm Time I_0_I 0 to 255 Seconds

6 B Key (Police) Alarm Output I_2_I 0 = No Sounder Output
7 C Key (Medical) Alarm Output I_1_I 1 = Keypad Sounder Only
2 = Keypad Sounder + Bell Output

8 Closing Bell Ringback I_0_I 0 = Ringback Output
1 = Ringback Output and Keypads
2 = Ringback Output, Bell & Keypads
9 Burglar Audible Lockout I_0_I 0 to 15 Alarms for Area (0 = Disabled)                                                
10 Swinger Shunt I_0_I 0 to 15 Zone Violations (0 = Disabled)
11 Area Attributes (see below) I_09_I (Don’t worry about this section)

First Digit 0 1 2 3 4 5 6 7 8 9 A B C D E F
All Features Below Disabled *
Two Button Arm * * * * * * * *
Double Button Press Arm * * * * * * * *
Open After Alarm * * * * * * * *
Display Bypassed Armed * * * * * * * *

Second Digit 0 1 2 3 4 5 6 7 8 9 A B C D E F
Double Press Panic Keys * * * * * * * *
Bypass * * * * * * * *
Force-Arm * * * * * * * *
Exit Arm * * * * * * * *
3 Second Panic Keys * * * * * * * *

AREA 2
12 Away Exit Delay Time I_60_I 0 to 255 Seconds
13 Stay/Night Exit Delay Time I_60_I 0 to 255 Seconds
14 Entry Delay 1 Time I_20_I 0 to 255 Seconds
15 Entry Delay 2 Time I_40_I 0 to 255 Seconds
16 Pre-Alarm Time I_0_I 0 to 255 Seconds

17 B Key (Police) Alarm Output I_2_I 0 = No Sounder Output
18 C Key (Medical) Alarm Output I_1_I 1 = Keypad Sounder Only
2 = Keypad Sounder + Bell Output
19 Closing Ringback I_0_I
20 Burglar Audible Lockout I_0_I
21 Swinger Shunt I_0_I
22 Area Attributes I_09_I

Loc Keypad Attributes Default
23 Keypad 1 LED I_1C_I
24 I_5_I

25 Keypad 2 LED I_1C_I
26 I_5_I

27 Keypad 3 SSD I_1C_I
28 I_5_I

29 Keypad 4 SSD I_1C_I
30 I_5_I

31 Keypad 5 LCD/VFD I_1C_I
32 I_5_I

33 Keypad 6 LCD/VFD I_1E_I
34 I_5_I
First Digit 0 1 2 3 4 5 6 7 8 9 A B C D E F
All Features Below Disabled *
C (Medical) Key Enabled * * * * * * * *
Silent Exit Time * * * * * * * *
Silent Entry Time * * * * * * * *
Silent Troubles * * * * * * * *

Second Digit 0 1 2 3 4 5 6 7 8 9 A B C D E F
Primary Area 1 * * * *
Primary Area 2 * * * *
Primary Area 1, Secondary Area 2 * * * *
Primary Area 2, Secondary Area 1 * * * *
A Key (Fire) Enabled * * * * * * * *
B Key (Police) Enabled * * * * * * * *

Zone Type Area Expansion
Zone
Burg Zn
Attribute
Zone
Attribute
Loc Default   Loc Default   Loc Default   Loc Default   Loc Default
Zone 01 35 I_1_I 36 I_1_I 37 I_0D_I 38 I_37_I
Zone 02 39 I_1_I 40 I_1_I 41 I_03_I 42 I_37_I
Zone 03 43 I_1_I 44 I_1_I 45 I_03_I 46 I_37_I
Zone 04 47 I_1_I 48 I_1_I 49 I_0C_I 50 I_37_I
Zone 05 51 I_1_I 52 I_1_I 53 I_0C_I 54 I_37_I
Zone 06 55 I_1_I 56 I_1_I 57 I_0C_I 58 I_37_I
Zone 07 59 I_1_I 60 I_1_I 61 I_0C_I 62 I_37_I
Zone 08 63 I_1_I 64 I_1_I 65 I_0C_I 66 I_37_I
Zone 09 67 I_1_I 68 I_1_I 69 I_0C_I 70 I_37_I
Zone 10 71 I_1_I 72 I_1_I 73 I_0C_I 74 I_37_I
Zone 11 75 I_1_I 76 I_1_I 77 I_0C_I 78 I_37_I
Zone 12 79 I_1_I 80 I_1_I 81 I_0C_I 82 I_37_I
Zone 13 83 I_1_I 84 I_0_I 85 I_0_I 86 I_0C_I 87 I_37_I
Zone 14 88 I_1_I 89 I_0_I 90 I_0_I 91 I_0C_I 92 I_37_I
Zone 15 93 I_1_I 94 I_0_I 95 I_0_I 96 I_0C_I 97 I_37_I
Zone 16 98 I_1_I 99 I_0_I 100 I_0_I 101 I_0C_I 102 I_37_I
Zone 17 103 I_1_I 104 I_0_I 105 I_0_I 106 I_0C_I 107 I_37_I
Zone 18 108 I_1_I 109 I_0_I 110 I_0_I 111 I_0C_I 112 I_37_I
Zone 19 113 I_1_I 114 I_0_I 115 I_0_I 116 I_0C_I 117 I_37_I
Zone 20 118 I_1_I 119 I_0_I 120 I_0_I 121 I_0C_I 122 I_37_I
Zone 21 123 I_1_I 124 I_0_I 125 I_0_I 126 I_0C_I 127 I_37_I
Zone 22 128 I_1_I 129 I_0_I 130 I_0_I 131 I_0C_I 132 I_37_I
Zone 23 133 I_1_I 134 I_0_I 135 I_0_I 136 I_0C_I 137 I_37_I
Zone 24 138 I_1_I 139 I_0_I 140 I_0_I 141 I_0C_I 142 I_37_I
Zone 25 143 I_1_I 144 I_0_I 145 I_0_I 146 I_0C_I 147 I_37_I
Zone 26 148 I_1_I 149 I_0_I 150 I_0_I 151 I_0C_I 152 I_37_I
Zone 27 153 I_1_I 154 I_0_I 155 I_0_I 156 I_0C_I 157 I_37_I
Zone 28 158 I_1_I 159 I_0_I 160 I_0_I 161 I_0C_I 162 I_37_I
Zone 29* 163 I_0_I 164 I_63_I
Zone 30** 165 I_2_I 166 I_63_I
* Zone 29 is the 2-Wire Smoke Zone on Expander Module
** Zone 30 is the 2-Wire Smoke Zone on the Control Board

Zone Type Area Expansion
0 = Not Used 0 = Disable 0 = ZXEXP Zone
1 = Burglar 1 = Area 1 1 = RF Gateway 1 Zone
2 = 24 Hr Fire 2 = Area 2 2 = RF Gateway 2 Zone
3 = 24 Hr Holdup 3 = ZEM Zone
4 = 24 Hr Auxiliary
5 = Momentary Keyswitch
  (ARM AWAY/Disarm)
Burg Zn Attribute
1st Digit 2nd Digit
6 = 24 Hr Communicator 0 = Standard Zone   D = Delay 1
7 = 24 Hr Burglar Tamper 1 = Chime Always C = Instant
8 = Universal 3 = Interior/Follower
9 = Universal Logged Zone Attribute
10 = Verified Fire 1st Digit 2nd Digit
11 = Fire Supervisory 1 = No EOL
12 = Listen-In Module Input   3 = EOL

USER CODE SETTINGS
USER CODE AUTHORITY LEVEL   AREA        
User Default Loc Default Loc Default
User 01   I_1_I_2_I_3_I_4_I     167   I_10_I 3 = Arm Only     168   I_1_I 0 = Disabled
User 02 I_0_I_0_I_0_I_0_I 169 I_6_I 6 = Standard 170 I_1_I 1 = Area 1
User 03 I_0_I_0_I_0_I_0_I 171 I_6_I 10 = Master 172 I_1_I 2 = Area 2
User 04 I_0_I_0_I_0_I_0_I 173 I_6_I 13 = Duress 174 I_1_I 3 = Both
User 05 I_0_I_0_I_0_I_0_I 175 I_6_I 176 I_1_I
User 06 I_0_I_0_I_0_I_0_I 177 I_6_I 178 I_1_I
User 07 I_0_I_0_I_0_I_0_I 179 I_6_I 180 I_1_I
User 08 I_0_I_0_I_0_I_0_I 181 I_6_I 182 I_1_I
User 09 I_0_I_0_I_0_I_0_I 183 I_6_I 184 I_1_I
User 10 I_0_I_0_I_0_I_0_I 185 I_6_I 186 I_1_I
User 11 I_0_I_0_I_0_I_0_I 187 I_6_I 188 I_1_I
User 12 I_0_I_0_I_0_I_0_I 189 I_6_I 190 I_1_I
User 13 I_0_I_0_I_0_I_0_I 191 I_6_I 192 I_1_I
User 14 I_0_I_0_I_0_I_0_I 193 I_6_I 194 I_1_I
User 15 I_0_I_0_I_0_I_0_I 195 I_6_I 196 I_1_I
User 16 I_0_I_0_I_0_I_0_I 197 I_6_I 198 I_1_I
User 17 I_0_I_0_I_0_I_0_I 199 I_6_I 200 I_1_I
User 18 I_0_I_0_I_0_I_0_I 201 I_6_I 202 I_1_I
User 19 I_0_I_0_I_0_I_0_I 203 I_6_I 204 I_1_I
User 20 I_0_I_0_I_0_I_0_I 205 I_6_I 206 I_1_I
User 21 I_0_I_0_I_0_I_0_I 207 I_6_I 208 I_1_I
User 22 I_0_I_0_I_0_I_0_I 209 I_6_I 210 I_1_I
User 23 I_0_I_0_I_0_I_0_I 211 I_6_I 212 I_1_I
User 24 I_0_I_0_I_0_I_0_I 213 I_6_I 214 I_1_I
User 25 I_0_I_0_I_0_I_0_I 215 I_6_I 216 I_1_I
User 26 I_0_I_0_I_0_I_0_I 217 I_6_I 218 I_1_I
User 27 I_0_I_0_I_0_I_0_I 219 I_6_I 220 I_1_I
User 28 I_0_I_0_I_0_I_0_I 221 I_6_I 222 I_1_I
User 29 I_0_I_0_I_0_I_0_I 223 I_6_I 224 I_1_I
User 30 I_0_I_0_I_0_I_0_I 225 I_6_I 226 I_1_I
User 31 I_0_I_0_I_0_I_0_I 227 I_6_I 228 I_1_I
User 32 I_0_I_0_I_0_I_0_I 229 I_6_I 230 I_1_I
User 33 I_0_I_0_I_0_I_0_I 231 I_6_I 232 I_1_I
User 34 I_0_I_0_I_0_I_0_I 233 I_6_I 234 I_1_I
User 35 I_0_I_0_I_0_I_0_I 235 I_6_I 236 I_1_I
User 36 I_0_I_0_I_0_I_0_I 237 I_6_I 238 I_1_I
User 37 I_0_I_0_I_0_I_0_I 239 I_6_I 240 I_1_I
User 38 I_0_I_0_I_0_I_0_I 241 I_6_I 242 I_1_I
User 39 I_0_I_0_I_0_I_0_I 243 I_6_I 244 I_1_I
User 40 I_0_I_0_I_0_I_0_I 245 I_6_I 246 I_1_I
User 41 I_0_I_0_I_0_I_0_I 247 I_6_I 248 I_1_I
User 42 I_0_I_0_I_0_I_0_I 249 I_6_I 250 I_1_I
User 43 I_0_I_0_I_0_I_0_I 251 I_6_I 252 I_1_I
User 44 I_0_I_0_I_0_I_0_I 253 I_6_I 254 I_1_I
User 45 I_0_I_0_I_0_I_0_I 255 I_6_I 256 I_1_I
User 46 I_0_I_0_I_0_I_0_I 257 I_6_I 258 I_1_I
User 47 I_0_I_0_I_0_I_0_I 259 I_6_I 260 I_1_I
User 48 I_0_I_0_I_0_I_0_I 261 I_6_I 262 I_1_I
User 49 I_0_I_0_I_0_I_0_I 263 I_6_I 264 I_1_I
User 50 I_0_I_0_I_0_I_0_I 265 I_10_I 266 I_3_I

OUTPUTS DEFAULT
268 Output 01 (see wire diagram) I_1_I (use 28 if trigger for 2-way)
0 = Not Used 19 = Exit Time
1 = Fire Alarm 20 = Entry Time
2 = Fire Supervisory 21 = Pre-Alarm Warning Time
3 = Duress 22 = Annunciation
4 = Low Battery 23 = Auto-Arm Warning
5 = Failed to Comm 24 = Closing Ringback
6 = Telco Line Fault 25 = Trouble
7 = Telco Line Seized 26 = Chime
8 = Ground Start 27 = Universal
9 = Burglar Alarm 28 = Listen-In Module Output
10 = Hold-up Alarm 29 = Lamp Trigger
11 = Auxiliary Alarm 30 = Key 4 Output
12 = Bell Output Trigger 31 = Key 5 Output
13 = Violation 32 = Key 6 Output
14 = Ready 33 = RF Annunciator
15 = Armed AWAY 34 = Access by Keypad
16 = Armed STAY 35 = Quick Access by Keypad
17 = Armed NIGHT 101 –
130
= Zone (1 to 30) Violated
18 = Armed and Exit Time Expired 201 –
230
= Zone (1 to 30) In Alarm or Senior Watch

269 Output 01 area of operation I_1_I (use 3 if 2-way)

1 = Area 1 (for Output Conditions 34 & 35)
2 = Area 2 1 = Control Station 1
3 = Both 2 = Control Station 2
4 = Control Station 3
8 = Control Station 4
16 = Control Station 5
32 = Control Station 6

MISC. sYSTEM FUNCTIONS
310 Fire Cutoff Time I_0_I 0 to 255 Min (0 = No Cutoff)
311 Burglar Cutoff Time I_10_I 0 to 255 Min (0 = No Cutoff)
312 Holdup Cutoff Time I_10_I 0 to 255 Min (0 = No Cutoff)
313 Aux Cutoff Time I_10_I 0 to 255 Min (0 = No Cutoff)
314 Universal Output Time I_0_I 0 to 255 Sec (0 = Toggle ON)
315 Delay Before Dial I_0_I 0 to 255 Sec (0 = No Delay)
316 Fire Delay Before Dial I_0_I 0 to 255 Sec (0 = No Delay)
317 AC Failure Delay I_30_I 0 to 255 Min
318 Senior Watch Time (Delinquency) I_24_I 0 to 42 Hrs
319 System Attributes I_31_I 00 to FF
320 Passcode Attempts I_8_I 1 to 15 Attempts (0 = No Lock)
321 AC Cycles I_0_I 0 = 60Hz, 1 = 50Hz

RECEIVER PHONE PROGRAMMING
322 Enable Communicator I_1_I 0 = No, 1 = Yes
323 Enable Skip Test I_0_I 0 = No, 1 = Yes
324 Power-Up Comm Test I_0_I 0 = No, 1 = Yes
325 Disable Call Waiting I_0_I 0 = No, 1 = Yes
323-327 Comm Test Time of Day (hr:min) 00:00 00:00 to 23:59
328 Days Between Communicator Tests I_0_I 0 to 255 Days (0 = Disable)
329 Time between Calls I_5_I 0 to 255 Seconds

330 T1 Transmission Format I_3_I 0 = Pulsed 20 Baud, Non-Extended
331 T2 Transmission Format I_3_I 1 = Pulsed 20 Baud, Extended
2 = Pulsed 40 Baud Extended
3 = Contact ID
4 = Pager (T2 Phone Only)

332 Dialer Type I_1_I 0 = Pulse, 1 = Tone, 2 = Euro Pulse
333 T1 Dial Attempts I_5_I 1 to 15 Attempts
334 T2 Dial Attempts I_5_I 1 to 15 Attempts
335 On-Hook Time I_5_I 1 to 15 Seconds
336 Off-Hook Time I_3_I 1 to 15 Seconds

337-352 Telephone 1 Number (Up to 16 Digits, Default = FFFFF)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
(A = 0 in Phone number B (11) = * C (12) = # D or E (14) = 3 Second Pause F (15) = End Phone Number)

353-376 Telephone 2 Number (Up to 24 Digits, Default = FFFFF)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I

377-392 RPM (Download) Phone Number (Up to 16 Digits, Default = FFFFF)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I

393-398 Area 1 Account 1 I_ _I_ _I_ _I_ _I_ _I_ _I (000000-FFFFFF)
399-404 Area 1 Account 2 I_ _I_ _I_ _I_ _I_ _I_ _I (000000-FFFFFF)
(Enter A for 0’s)
Hex Program 10 = A 11 = B 12 = C 13 = D 14 = E 15 = F

405-410 Area 2 Account 1 I_ _I_ _I_ _I_ _I_ _I_ _I (000000-FFFFFF)
411-416 Area 2 Account 2 I_ _I_ _I_ _I_ _I_ _I_ _I (000000-FFFFFF)

417 Fire Alarm Call Direction I_3_I 0 = Do Not Report
418 System Events Call Direction I_0_I 1 = Phone 1 Only
419 Burglar Alarm Call Direction I_3_I 2 = Phone 2 Only
420 Hold Up Alarm Call Direction I_3_I 3 = Phone 1 (2 on Failure)
421 Auxiliary Alarm Call Direction I_3_I 4 = Phone 2 (1 on Failure)
422 Critical Condition Call Direction I_3_I 5 = Phone 1 and 2
423 Zone Trouble/Restore Call Direction I_0_I
424 Zone bypass/Restore Call Direction I_0_I
425 Open/Close Call Direction I_0_I
426 Supervision Call Direction I_0_I

AREA 2 Phone Call Directions
427 Burglar Alarm Call Direction I_3_I 2 = Phone 2 Only
428 Hold Up Alarm Call Direction I_3_I 3 = Phone 1 (2 on Failure)
429 Aux Panic Alarm Call Direction I_3_I 4 = Phone 2 (1 on Failure)
430 Critical Condition Call Direction I_3_I 5 = Phone 1 and 2
431 Zone Trouble/Restore Call Direction I_0_I
432 Zone Bypass/Restore Call Direction I_0_I
433 Open/Close Call Direction I_0_I
434 Supervision Call Direction I_0_I

ZONE REPORT CODES
ALARM RESTORE BYPASS TROUBLE
Loc Default     Loc Default     Loc Default     Loc Default
ZONE 01 435 I_31_I 436 I_E3_I 437 I_AB_I 438 I_F3_I
ZONE 02 439 I_32_I 440 I_E3_I 441 I_AB_I 442 I_F3_I
ZONE 03 443 I_33_I 444 I_E3_I 445 I_AB_I 446 I_F3_I
ZONE 04 447 I_34_I 448 I_E3_I 449 I_AB_I 450 I_F3_I
ZONE 05 451 I_35_I 452 I_E3_I 453 I_AB_I 454 I_F3_I
ZONE 06 455 I_36_I 456 I_E3_I 457 I_AB_I 458 I_F3_I
ZONE 07 459 I_37_I 460 I_E3_I 461 I_AB_I 462 I_F3_I
ZONE 08 463 I_38_I 464 I_E3_I 465 I_AB_I 466 I_F3_I
ZONE 09 467 I_39_I 468 I_E3_I 467 I_AB_I 468 I_F3_I
ZONE 10 471 I_3A_I 472 I_E3_I 473 I_AB_I 474 I_F3_I
ZONE 11 475 I_3B_I 476 I_E3_I 477 I_AB_I 478 I_F3_I
ZONE 12 479 I_3C_I 480 I_E3_I 481 I_AB_I 482 I_F3_I
ZONE 13 483 I_3D_I 484 I_E3_I 485 I_AB_I 486 I_F3_I
ZONE 14 487 I_3E_I 488 I_E3_I 489 I_AB_I 490 I_F3_I
ZONE 15 491 I_3F_I 492 I_E3_I 493 I_AB_I 494 I_F3_I
ZONE 16 495 I_61_I 496 I_E6_I 497 I_AB_I 498 I_F6_I
ZONE 17 499 I_62_I 500 I_E6_I 501 I_AB_I 502 I_F6_I
ZONE 18 503 I_63_I 504 I_E6_I 505 I_AB_I 506 I_F6_I
ZONE 19 507 I_64_I 508 I_E6_I 509 I_AB_I 510 I_F6_I
ZONE 20 511 I_65_I 512 I_E6_I 513 I_AB_I 514 I_F6_I
ZONE 21 515 I_66_I 516 I_E6_I 517 I_AB_I 518 I_F6_I
ZONE 22 519 I_67_I 520 I_E6_I 521 I_AB_I 522 I_F6_I
ZONE 23 523 I_68_I 524 I_E6_I 525 I_AB_I 526 I_F6_I
ZONE 24 527 I_69_I 528 I_E6_I 529 I_AB_I 530 I_F6_I
ZONE 25 531 I_6A_I 532 I_E6_I 533 I_AB_I 534 I_F6_I
ZONE 26 535 I_6B_I 536 I_E6_I 537 I_AB_I 538 I_F6_I
ZONE 27 539 I_6C_I 540 I_E6_I 541 I_AB_I 542 I_F6_I
ZONE 28 543 I_6D_I 544 I_E6_I 545 I_AB_I 546 I_F6_I
ZONE 29 547 I_11_I 548 I_E1_I 549 I_AB_I 550 I_F1_I
ZONE 30     551   I_12_I 552   I_E1_I 553   I_AB_I 554   I_F1_I

SYSTEM REPORT CODES
655 A Key (Fire) Report Code I_19_I
656 B Key (Police) Report Code I_29_I
657 C Key (Medical) Report Code I_49_I
658 Duress Report Code I_99_I
659 Keypad Lockout Report Code I_00_I
660 Burg Cancel Report Code I_00_I
661 Quick Arm Report Code I_00_I
662 Auto Arm Report Code I_00_I
663 Auto Arm Failed Report Code I_00_I
664 Keyswitch Close Rep Code I_00_I
665 Keyswitch Open Rep Code I_00_I
666 Download Closing Rep Code I_00_I
667 Download Opening Rep Code I_00_I
668 Closing Extended Code I_00_I
669 Exit Alarm Report Code I_00_I
670 Recent Closing Report Code I_00_I
671 Latchkey Supervisory Code I_00_I
672 User On-Premise Code I_00_I
673 Com Test Not Normal Code I_00_I
674 Comm Test Report Code I_00_I
675 AC Fail Report Code I_FA_I
676 AC Restore Report Code I_00_I
677 Low Battery Report Code I_F9_I
678 Battery Restore Report Code I_00_I
679 Bell Fault Report Code I_00_I
680 Bell Restore Report Code I_00_I
681 Comm Restore Report Code I_00_I
682 Memory Error Report Code I_00_I
683 Local Program Begin Code I_00_I
684 Local Program End Code I_00_I
685 RPM End Report Code I_00_I
686 RPM Denied Report Code I_00_I
687 RPM Abort Report Code I_00_I
688 Missing Keypad Rep Code I_00_I
689 Restore Keypad Rep Code I_00_I
690 RF Jamming Rep Code I_00_I
691 RF Channel Clear Rep Code I_00_I
692 Keyfob Low Battery Rep Code I_00_I

INSTALLER STUFF
759-762 Installer Passcode I_9_I_6_I_3_I_2_I 0000 TO 9999
763 Call 2 Timer (Double Call Timer) I_0_I 0 to 255 seconds
764 Auto Answer Ring Count I_5_I 0 to 15 Rings
765 Enable RPM (Download) I_1_I 0 = No, 1 = Yes
766 Enable Power-Up Programming I_0_I 0 = No, 1 = Yes
767 Lockout Local Programming I_0_I 0 = No, 1 = Yes