System Times |
LOC |
Feature |
|
Options |
1 |
Away Exit Delay Time |
I_60_I |
0 to 255 Seconds |
2 |
Stay/Night Exit Delay Time |
I_60_I |
0 to 255 Seconds |
3 |
Entry Delay Time 1 |
I_30_I |
0 to 255 Seconds |
4 |
Entry Delay Time 2 |
I_40_I |
0 to 255 Seconds |
5 |
Fire Alarm Cutoff Time |
I_6_I |
0 to 255 Seconds |
6 |
Other Alarm Cutoff Time |
I_6_I |
0 to 255 Seconds |
7 |
Access Time |
I_7_I |
0 to 255 Seconds |
8 |
Alarm Abort Time |
I_30_I |
0 to 255 Seconds |
9 |
AC Failure Delay |
I_60_I |
0 to 255 Minutes |
10 |
Burglar Audible Lockout |
I_0_I |
0 to 15 Alarms |
11 |
Reserved |
I_0_I |
12 |
Reserved |
I_0_I
|
Keypad Options |
LOC |
Feature |
|
Options |
13 |
B (Police) Key/Holdup Alarms |
I_0_I |
0 = No Sounder Output |
14 |
C (Medical) Key Alarms |
I_1_I |
1 = Keypad Sounder Only |
15 |
Burglar Alarms |
I_2_I |
2 = Keypad Sounder + Bell Output
|
16 |
Enable Bypassing |
I_1_I |
0 = Disabled |
17 |
Enable Force Arming |
I_0_I |
1 = Enabled |
18 |
Enable Double Press Arming |
I_0_I |
19 |
Enable Press & Hold Arming |
I_0_I |
20 |
Report Openings only After Alarms |
I_0_I |
21 |
Programming At Power-Up |
I_0_I
|
Bell/Siren Options |
LOC |
Feature |
|
Options |
22 |
Fire Bell Type |
I_1_I |
0 = Steady Tone |
23 |
Burglar Bell Type |
I_0_I |
1 = Temporal Tone |
24 |
Holdup Bell |
I_0_I |
25 |
Auxiliary Bell |
I_0_I |
26 |
Bell Test on AWAY Arming |
I_0_I |
0 = Disabled
1 = Enabled
|
27 |
Two-Hit Swinger Shunt |
I_0_I |
0 = One Alarm
1 = 2 Alarms
|
28 |
RF Exit Time |
I_0_I |
0 = Disabled
1 = Enabled
|
Keypad Options |
LOC |
Feature |
|
Options |
29 |
Pager Key Enable |
I_0_I |
0 = Disabled
1 = Center Panic Key
2 = Right Panic Key
|
30 |
Keypad #1 Options |
I_1_I |
0 = Panic Keys Disabled |
31 |
Keypad #2 Options |
I_1_I |
1 = Panic Keys Enabled |
32 |
Keypad #3 Options |
I_1_I |
2 = Panic Keys Disabled/Silent Keypad |
33 |
Keypad #4 Options |
I_1_I |
3 = Panic Keys Enabled/Silent Keypad
|
Zone Programming |
LOC |
Feature |
|
Options |
34 |
Zone 1 Type |
I_1_I |
0 = Not Used/Disabled |
37 |
Zone 2 Type |
I_3_I |
1 = Delay 1 |
40 |
Zone 3 Type |
I_3_I |
2 = Delay 2 |
43 |
Zone 4 Type |
I_1_I |
3 = Interior Follower |
46 |
Zone 5 Type |
I_1_I |
4 = Instant |
49 |
Zone 6 Type |
I_1_I |
5 = 24 Hour Fire |
52 |
Zone 7 Type |
I_1_I |
6 = 24 Hour Verified Fire (2 trips req) |
55 |
Zone 8 Type |
I_1_I |
7 = 24 Hour Holdup |
58 |
Zone 9 Type |
I_0_I |
8 = 24 Hour Auxiliary |
61 |
Zone 10 Type |
I_0_I |
9 = 24 Hour CO Gas |
64 |
Zone 11 Type |
I_0_I |
10 = Momentary Keyswitch Arm/Disarm |
67 |
Zone 12 Type |
I_0_I |
11 = 24 Hr Critical Condition Monitor (CCM) |
70 |
Zone 13 Type |
I_0_I |
73 |
Zone 14 Type |
I_0_I |
76 |
Zone 15 Type |
I_0_I |
79 |
Zone 16 Type |
I_0_I
|
35 |
Zone 1 Attributes |
I_15_I |
0 = No Bypass/No Report/Arm Away |
38 |
Zone 2 Attributes |
I_3_I |
1 = Bypass/No Report/Arm Away |
41 |
Zone 3 Attributes |
I_3_I |
2 = No Bypass/Reports/Arm Away |
44 |
Zone 4 Attributes |
I_7_I |
3 = Bypass/Reports/Arm Away |
47 |
Zone 5 Attributes |
I_15_I |
4 = No Bypass/No Report/Arm Away & Stay |
50 |
Zone 6 Attributes |
I_15_I |
5 = Bypass/No Report/Arm Away & Stay |
53 |
Zone 7 Attributes |
I_15_I |
6 = No Bypass/Reports/Arm Away & Stay |
56 |
Zone 8 Attributes |
I_15_I |
7 = Bypass/Reports/Arm Away & Stay |
59 |
Zone 9 Attributes |
I_15_I |
8 = No Bypass/No Report/Arm Away & Night |
62 |
Zone 10 Attributes |
I_15_I |
9 = Bypass/No Report/Arm Away & Night |
65 |
Zone 11 Attributes |
I_15_I |
10 = No Bypass/Reports/Arm Away & Night |
68 |
Zone 12 Attributes |
I_15_I |
11 = Bypass/Reports/Arm Away & Night |
71 |
Zone 13 Attributes |
I_15_I |
12 = No Bypass/No Report/Arm Away, Stay & Night |
74 |
Zone 14 Attributes |
I_15_I |
13 = Bypass/No Report/Arm Away, Stay & Night |
77 |
Zone 15 Attributes |
I_15_I |
14 = No Bypass/Reports/Arm Away, Stay & Night |
80 |
Zone 16 Attributes |
I_15_I |
15 = Bypass/Reportable/Arm Away, Stay & Night
|
36 |
Zone 1 Supervision |
I_2_I |
0 = Alarm on Open/No Trouble |
39 |
Zone 2 Supervision |
I_2_I |
1 = Alarm on Short/No Trouble |
42 |
Zone 3 Supervision |
I_2_I |
2 = Alarm on Open or Short/No Trouble |
45 |
Zone 4 Supervision |
I_2_I |
3 = Trouble on Open or Short |
48 |
Zone 5 Supervision |
I_2_I |
4 = Alarm on Open/Trouble on Short |
51 |
Zone 6 Supervision |
I_2_I |
5 = Alarm on Short/Trouble on Open |
54 |
Zone 7 Supervision |
I_2_I |
6 = Alarm on Open or Short/Trouble on Open |
57 |
Zone 8 Supervision |
I_2_I |
7 = Wireless Zone |
60 |
Zone 9 Supervision |
I_7_I |
8 = 2=Wire Smoke (Zone 8 Only) |
63 |
Zone 10 Supervision |
I_7_I |
66 |
Zone 11 Supervision |
I_7_I |
69 |
Zone 12 Supervision |
I_7_I |
72 |
Zone 13 Supervision |
I_7_I |
75 |
Zone 14 Supervision |
I_7_I |
78 |
Zone 15 Supervision |
I_7_I |
81 |
Zone 16 Supervision |
I_7_I
|
User Code Options
(User Codes must be programmed in User Level only)
|
LOC |
Feature |
|
Options |
82 |
User 01 Authority Level |
I_1_I |
0 = Disabled |
83 |
User 02 Authority Level |
I_1_I |
1 = Master Code |
84 |
User 03 Authority Level |
I_1_I |
2 = Duress Code |
85 |
User 04 Authority Level |
I_1_I |
3 = Maids Code |
86 |
User 05 Authority Level |
I_1_I |
4 = User On Premise |
87 |
User 06 Authority Level |
I_1_I |
88 |
User 07 Authority Level |
I_1_I |
89 |
User 08 Authority Level |
I_1_I |
|
(User 09 is Installer Code but can’t be programmed here?)
|
PGM Programming
(On External ZXODM Module)
|
LOC |
Feature |
|
Options |
90 |
Control Output |
I_10_I |
0 = Not Used |
91 |
ODM Output 01 |
I_6_I |
1 = Fire Alarm Indicator |
92 |
ODM Output 02 |
I_1_I |
2 = Duress until CLEAR Held |
93 |
ODM Output 03 |
I_7_I |
3 = Low Battery (below 11.3volts) |
94 |
ODM Output 04 |
I_8_I |
4 = Fail To Communicate |
95 |
ODM Output 05 |
I_12_I |
5 = Telco Line Fault |
96 |
ODM Output 06 |
I_14_I |
6 = Burglar Alarm Indicator |
97 |
ODM Output 07 |
I_11_I |
7 = Holdup Alarm Indicator |
98 |
ODM Output 08 |
I_13_I |
8 = Auxiliary Alarm Indicator |
99 |
ODM Output 09 |
I_15_I |
9 = Bell Output Trigger |
100 |
ODM Output 10 |
I_17_I |
10 = Alarm Violation
11 = Ready
12 = Armed
13 = Trouble Condition
14 = Chime
15 = Lamp Trigger
16 = RF Annunciator
17 = Access Output
18 = CO Gas Detected
|
Communicator Options |
LOC |
Feature |
|
Options |
101 |
Enable Communicator |
I_1_I |
0 = Disabled
1 = Enabled
2 = Enabled with Audible Phone Monitor
3 = Enabled with Silent Phone Monitor
|
102 |
Days Between Communicator Test |
I_30_I |
0 to 255 Days
|
103 |
Time Between Calls |
I_5_I |
0 to 255 Seconds
|
104 |
CS1 Transmission Format |
I_1_I |
0 = SIA |
105 |
CS2 Transmission Format |
I_1_I |
1 = Contact ID
|
106 |
Dialer Type |
I_2_I |
0 = US Rotary
1 = Foreign Rotory
2 = Touchtone
3 = Touchtone with Call Waiting Disabled
|
107 |
CS1 Dial Attempts |
I_8_I |
1 to 15 Dial Attempts |
108 |
CS2 Dial Attempts |
I_8_I |
1 to 15 Dial Attempts |
109 |
Pager Dial Attempts |
I_1_I |
1 to 15 Dial Attempts
|
110 |
Pager Delay Time |
I_15_I |
0 to 255 Seconds |
111 |
On-Hook Time |
I_5_I |
1 to 15 Seconds |
112 |
Off-Hook Time |
I_3_I |
1 to 15 Seconds
|
Event Reporting |
LOC |
Feature |
|
Options |
113 |
Alarm/Restore Call Direction |
I_3_I |
0 = No Report/Disabled |
114 |
Bypass/Restore Call Direction |
I_0_I |
1 = CS1 Phone Only |
115 |
Open/Close Call Direction |
I_0_I |
2 = CS2 Phone Only |
116 |
Zone Trouble/Restore Call Direction |
I_0_I |
3 = CS1 Phone (CS2 Phone on Fail) |
117 |
System Trouble 1 Call Direction |
I_1_I |
4 = CS2 Phone (CS1 Phone on Fail) |
118 |
System Trouble 2 Call Direction |
I_0_I |
5 = CS1 Phone and CS2 Phone |
119 |
System Events Phone Direction
(Trouble 1 is Low bat, AC Faile etc)
(Trouble 2 is mainly RF Troubles)
(System Events is Download Report)
|
I_0_I |
6 = Pager Only
7 = CS1 Phone and Pager
8 = CS2 Phone and Pager
9 = CS1 Phone (CS2 Phone on Fail) and Pager
10 = CS2 Phone (CS1 Phone on Fail) and Pager
11 = CS1 Phone and CS2 Phone and Pager
|
Phone Numbers and Accounts |
LOC |
Feature |
120-125 |
Account Number 1 |
I_ _I_ _I_ _I_ _I_ _I_ _I (up to 6 digits)
Hex Program 10 = A 11 = B 12 = C 13 = D 14 = E 15 = F
|
126-131 |
Account Number 2 |
I_ _I_ _I_ _I_ _I_ _I_ _I (up to 6 digits)
|
132-151 |
Receiver 1 Telephone Number (20 Digits)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
(A = 0 in Phone number B (11) = * C (12) = # D or E (14) = 3 Second Pause F (15) = End Phone Number)
|
152-171 |
Receiver 2 Telephone Number F’s (Up to 20 Digits)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
|
172-191 |
Pager Telephone Number (20 Digits)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
(Enter 2 or 3 D’s or E’s after pager number to pause enough to send data)
|
192-211 |
Reserved (20 Digits)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
|
212-227 |
Pager Header (20 Digits) (Sends before Event)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
|