Enter Program 9 + 9632 + 3 or power down & up and press 9 then 9999 in 60 seconds
Options 9 + Installer Code + 1 = Answer Download Request (Maybe)
9 + Installer Code + 2 = Future Use
9 + Installer Code + 3 = Enter Installer Programming
9 + Installer Code + 4 = Future Use
9 + Installer Code + 5 = Program User Codes
9 + Installer Code + 6 = Reset to Factory Defaults
9 + Installer Code + 7 = Set Hours until next Communicator Test
9 + Installer Code + 8 = Call Download Computer
9 + Installer Code + 9 = Program RF Sensors
Move to
Location
3-Digit Location + ENTER
Enter Data 1 to 3 digit Value + ENTER to save and ENTER again to move to next
ENTER Key Saves new value in a Location
If no new value is entered in a Location will move to next Location
CLEAR Key If pressed in Location after entering new value erases and reverts to old values
If pressed in Location and no new values entered will exit to top program level
MEDICAL Panic Moves to previous Program Location, ignores changes to current Location
OFF/CANCEL Press and hold to display current programming in Location
Exit Program Press CLEAR twice
Hex Program 10 = A 11 = B 12 = C 13 = D 14 = E 15 = F

System Times
LOC Feature Options
1 Away Exit Delay Time I_60_I 0 to 255 Seconds
2 Stay/Night Exit Delay Time I_60_I 0 to 255 Seconds
3 Entry Delay Time 1 I_30_I 0 to 255 Seconds
4 Entry Delay Time 2 I_40_I 0 to 255 Seconds
5 Fire Alarm Cutoff Time I_6_I 0 to 255 Seconds
6 Other Alarm Cutoff Time I_6_I 0 to 255 Seconds
7 Access Time I_7_I 0 to 255 Seconds
8 Alarm Abort Time I_30_I 0 to 255 Seconds
9 AC Failure Delay I_60_I 0 to 255 Minutes
10 Burglar Audible Lockout I_0_I 0 to 15 Alarms
11 Reserved I_0_I
12 Reserved I_0_I

Keypad Options
LOC Feature Options
13 B (Police) Key/Holdup Alarms I_0_I 0 = No Sounder Output
14 C (Medical) Key Alarms I_1_I 1 = Keypad Sounder Only
15 Burglar Alarms I_2_I 2 = Keypad Sounder + Bell Output

16 Enable Bypassing I_1_I 0 = Disabled
17 Enable Force Arming I_0_I 1 = Enabled
18 Enable Double Press Arming I_0_I
19 Enable Press & Hold Arming I_0_I
20 Report Openings only After Alarms I_0_I
21 Programming At Power-Up I_0_I

Bell/Siren Options
LOC Feature Options
22 Fire Bell Type I_1_I 0 = Steady Tone
23 Burglar Bell Type I_0_I 1 = Temporal Tone
24 Holdup Bell I_0_I
25 Auxiliary Bell I_0_I
26 Bell Test on AWAY Arming I_0_I 0 = Disabled
1 = Enabled

27 Two-Hit Swinger Shunt I_0_I 0 = One Alarm
1 = 2 Alarms

28 RF Exit Time I_0_I 0 = Disabled
1 = Enabled

Keypad Options
LOC Feature Options
29 Pager Key Enable I_0_I 0 = Disabled
1 = Center Panic Key
2 = Right Panic Key

30 Keypad #1 Options I_1_I 0 = Panic Keys Disabled
31 Keypad #2 Options I_1_I 1 = Panic Keys Enabled
32 Keypad #3 Options I_1_I 2 = Panic Keys Disabled/Silent Keypad
33 Keypad #4 Options I_1_I 3 = Panic Keys Enabled/Silent Keypad

Zone Programming
LOC Feature Options
34 Zone 1 Type I_1_I 0 = Not Used/Disabled
37 Zone 2 Type I_3_I 1 = Delay 1
40 Zone 3 Type I_3_I 2 = Delay 2
43 Zone 4 Type I_1_I 3 = Interior Follower
46 Zone 5 Type I_1_I 4 = Instant
49 Zone 6 Type I_1_I 5 = 24 Hour Fire
52 Zone 7 Type I_1_I 6 = 24 Hour Verified Fire (2 trips req)
55 Zone 8 Type I_1_I 7 = 24 Hour Holdup
58 Zone 9 Type I_0_I 8 = 24 Hour Auxiliary
61 Zone 10 Type I_0_I 9 = 24 Hour CO Gas
64 Zone 11 Type I_0_I 10 = Momentary Keyswitch Arm/Disarm
67 Zone 12 Type I_0_I 11 = 24 Hr Critical Condition Monitor (CCM)
70 Zone 13 Type I_0_I
73 Zone 14 Type I_0_I
76 Zone 15 Type I_0_I
79 Zone 16 Type I_0_I

35 Zone 1 Attributes I_15_I 0 = No Bypass/No Report/Arm Away
38 Zone 2 Attributes I_3_I 1 = Bypass/No Report/Arm Away
41 Zone 3 Attributes I_3_I 2 = No Bypass/Reports/Arm Away
44 Zone 4 Attributes I_7_I 3 = Bypass/Reports/Arm Away
47 Zone 5 Attributes I_15_I 4 = No Bypass/No Report/Arm Away & Stay
50 Zone 6 Attributes I_15_I 5 = Bypass/No Report/Arm Away & Stay
53 Zone 7 Attributes I_15_I 6 = No Bypass/Reports/Arm Away & Stay
56 Zone 8 Attributes I_15_I 7 = Bypass/Reports/Arm Away & Stay
59 Zone 9 Attributes I_15_I 8 = No Bypass/No Report/Arm Away & Night
62 Zone 10 Attributes I_15_I 9 = Bypass/No Report/Arm Away & Night
65 Zone 11 Attributes I_15_I 10 = No Bypass/Reports/Arm Away & Night
68 Zone 12 Attributes I_15_I 11 = Bypass/Reports/Arm Away & Night
71 Zone 13 Attributes I_15_I 12 = No Bypass/No Report/Arm Away, Stay & Night
74 Zone 14 Attributes I_15_I 13 = Bypass/No Report/Arm Away, Stay & Night
77 Zone 15 Attributes I_15_I 14 = No Bypass/Reports/Arm Away, Stay & Night
80 Zone 16 Attributes I_15_I 15 = Bypass/Reportable/Arm Away, Stay & Night

36 Zone 1 Supervision I_2_I 0 = Alarm on Open/No Trouble
39 Zone 2 Supervision I_2_I 1 = Alarm on Short/No Trouble
42 Zone 3 Supervision I_2_I 2 = Alarm on Open or Short/No Trouble
45 Zone 4 Supervision I_2_I 3 = Trouble on Open or Short
48 Zone 5 Supervision I_2_I 4 = Alarm on Open/Trouble on Short
51 Zone 6 Supervision I_2_I 5 = Alarm on Short/Trouble on Open
54 Zone 7 Supervision I_2_I 6 = Alarm on Open or Short/Trouble on Open
57 Zone 8 Supervision I_2_I 7 = Wireless Zone
60 Zone 9 Supervision I_7_I 8 = 2=Wire Smoke (Zone 8 Only)
63 Zone 10 Supervision I_7_I
66 Zone 11 Supervision I_7_I
69 Zone 12 Supervision I_7_I
72 Zone 13 Supervision I_7_I
75 Zone 14 Supervision I_7_I
78 Zone 15 Supervision I_7_I
81 Zone 16 Supervision I_7_I

User Code Options
(User Codes must be programmed in User Level only)

LOC Feature Options
82 User 01 Authority Level I_1_I 0 = Disabled
83 User 02 Authority Level I_1_I 1 = Master Code
84 User 03 Authority Level I_1_I 2 = Duress Code
85 User 04 Authority Level I_1_I 3 = Maids Code
86 User 05 Authority Level I_1_I 4 = User On Premise
87 User 06 Authority Level I_1_I
88 User 07 Authority Level I_1_I
89 User 08 Authority Level I_1_I
(User 09 is Installer Code but can’t be programmed here?)

PGM Programming
(On External ZXODM Module)

LOC Feature Options
90 Control Output I_10_I 0 = Not Used
91 ODM Output 01 I_6_I 1 = Fire Alarm Indicator
92 ODM Output 02 I_1_I 2 = Duress until CLEAR Held
93 ODM Output 03 I_7_I 3 = Low Battery (below 11.3volts)
94 ODM Output 04 I_8_I 4 = Fail To Communicate
95 ODM Output 05 I_12_I 5 = Telco Line Fault
96 ODM Output 06 I_14_I 6 = Burglar Alarm Indicator
97 ODM Output 07 I_11_I 7 = Holdup Alarm Indicator
98 ODM Output 08 I_13_I 8 = Auxiliary Alarm Indicator
99 ODM Output 09 I_15_I 9 = Bell Output Trigger
100 ODM Output 10 I_17_I 10 = Alarm Violation
11 = Ready
12 = Armed
13 = Trouble Condition
14 = Chime
15 = Lamp Trigger
16 = RF Annunciator
17 = Access Output
18 = CO Gas Detected

Communicator Options
LOC Feature Options
101 Enable Communicator I_1_I 0 = Disabled
1 = Enabled
2 = Enabled with Audible Phone Monitor
3 = Enabled with Silent Phone Monitor

102 Days Between Communicator Test I_30_I 0 to 255 Days

103 Time Between Calls I_5_I 0 to 255 Seconds

104 CS1 Transmission Format I_1_I 0 = SIA
105 CS2 Transmission Format I_1_I 1 = Contact ID

106 Dialer Type I_2_I 0 = US Rotary
1 = Foreign Rotory
2 = Touchtone
3 = Touchtone with Call Waiting Disabled

107 CS1 Dial Attempts I_8_I 1 to 15 Dial Attempts
108 CS2 Dial Attempts I_8_I 1 to 15 Dial Attempts
109 Pager Dial Attempts I_1_I 1 to 15 Dial Attempts

110 Pager Delay Time I_15_I 0 to 255 Seconds
111 On-Hook Time I_5_I 1 to 15 Seconds
112 Off-Hook Time I_3_I 1 to 15 Seconds

Event Reporting
LOC Feature Options
113 Alarm/Restore Call Direction I_3_I 0 = No Report/Disabled
114 Bypass/Restore Call Direction I_0_I 1 = CS1 Phone Only
115 Open/Close Call Direction I_0_I 2 = CS2 Phone Only
116 Zone Trouble/Restore Call Direction I_0_I 3 = CS1 Phone (CS2 Phone on Fail)
117 System Trouble 1 Call Direction I_1_I 4 = CS2 Phone (CS1 Phone on Fail)
118 System Trouble 2 Call Direction I_0_I 5 = CS1 Phone and CS2 Phone
119 System Events Phone Direction
(Trouble 1 is Low bat, AC Faile etc)
(Trouble 2 is mainly RF Troubles)
(System Events is Download Report)
I_0_I 6 = Pager Only
7 = CS1 Phone and Pager
8 = CS2 Phone and Pager
9 = CS1 Phone (CS2 Phone on Fail) and Pager
10 = CS2 Phone (CS1 Phone on Fail) and Pager
11 = CS1 Phone and CS2 Phone and Pager

Phone Numbers and Accounts
LOC Feature
120-125 Account Number 1 I_ _I_ _I_ _I_ _I_ _I_ _I (up to 6 digits)
Hex Program 10 = A 11 = B 12 = C 13 = D 14 = E 15 = F

126-131 Account Number 2 I_ _I_ _I_ _I_ _I_ _I_ _I (up to 6 digits)

132-151 Receiver 1 Telephone Number (20 Digits)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
(A = 0 in Phone number B (11) = * C (12) = # D or E (14) = 3 Second Pause F (15) = End Phone Number)

152-171 Receiver 2 Telephone Number F’s (Up to 20 Digits)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I

172-191 Pager Telephone Number (20 Digits)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
(Enter 2 or 3 D’s or E’s after pager number to pause enough to send data)

192-211 Reserved (20 Digits)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I

212-227 Pager Header (20 Digits) (Sends before Event)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I