Moose ZX 200 / 210 Program

Formats Contact ID or 4/2 (Contact ID preferred)
Enter Program 9 + 9632 + 3 or power down & up and press 9 then 9999 in 60 seconds
Options 9 + Installer Code + 1 = Answer Download Request
9 + Installer Code + 2 = Future Use
9 + Installer Code + 3 = Enter Installer Programming
9 + Installer Code + 4 = Future Use
9 + Installer Code + 5 = Program User Codes
9 + Installer Code + 6 = Reset to Factory Defaults
9 + Installer Code + 7 = Set Hours until next Communicator Test
9 + Installer Code + 8 = Call Download Computer
9 + Installer Code + 9 = Program RF Sensors
Move to
Location
3-Digit Location + ENTER
Enter Data 1 to 3 digit Value + ENTER to save and ENTER again to move to next
ENTER Key Saves new value in a Location
If no new value is entered in a Location will move to next Location
CLEAR Key If pressed in Location after entering new value erases and reverts to old values
If pressed in Location and no new values entered will exit to top program level
MEDICAL Panic Moves to previous Program Location (Also known as C Key)
OFF/CANCEL Press and hold to display current programming in Location
Exit Program Press CLEAR twice

Misc Options
Location Feature Variables
1 Away Exit Delay Time I_60_I 0 to 255 Seconds
2 Stay/Night Exit Delay Time I_60_I 0 to 255 Seconds
3 Entry Delay Time 1 I_30_I 0 to 255 Seconds
4 Entry Delay Time 2 I_40_I 0 to 255 Seconds
5 Fire Alarm Cutoff Time I_6_I 0 to 255 Seconds
6 Other Alarms Cutoff Time I_6_I 0 to 255 Seconds
7 Access Time I_5_I 0 to 255 Seconds
8 Delay Before Dial Timer I_0_I 0 to 255 Seconds
9 Fire Delay Before Dial Timer I_0_I 0 to 255 Seconds
10 AC Failure Delay Timer I_60_I 0 to 255 Seconds

11 Burglar Audible Lockout I_3_I 0 to 15 Alarms
12 Swinger Shutdown I_3_I 0 to 15 Violations
13 Passcode Entry Lockout I_8_I 0 to 15 Attempts

14 Rings Until Answer I_5_I 0 to 15 Rings
15 Second Call Bypass Timer I_60_I 0 to 255 seconds, default = 15

16 Holdup Alarms (B Key) I_0_I 0 = No Sounder Output
17 Auxiliary Alarms (C Key) I_1_I 1 = Keypad Sounder Only
18 Burglar Alarms I_2_I 2 = Keypad Sounder + Bell Output

19 Enable Bypassing I_1_I 0 = No, 1 = Yes
20 Enable Force Arming I_0_I 0 = No, 1 = Yes
21 Enable Two-Button Arming I_0_I 0 = No, 1 = Yes
22 Enable Double-Press Arming I_0_I 0 = No, 1 = Yes
23 Opening Report Only After Alarm I_0_I 0 = No, 1 = Yes
24 Enable Remote Programming I_1_I 0 = No, 1 = Yes
25 Enable Programming At Power-Up I_0_I 0 = No, 1 = Yes
26 Lockout Installer Programming I_0_I 0 = No, 1 = Yes
27 Fire Bell I_1_I 0 = Steady, 1 = Pulsed
28 Burglar Bell I_0_I 0 = Steady, 1 = Pulsed
29 Holdup Bell I_0_I 0 = Steady, 1 = Pulsed
30 Auxiliary Bell I_0_I 0 = Steady, 1 = Pulsed
31 Bell Test On Away Arm I_0_I 0 = No, 1 = Yes
32 Display Bypassed While Armed I_0_I 0 = No, 1 = Yes
33 Two Wire Smoke Enable I_0_I 0 = No, 1 = Yes (Zone 8 only)

34 Keypad 1 Options I_1_I 0 = Panic Keys Disabled
35 Keypad 2 Options I_1_I 1 = Panic Keys Enabled
36 Keypad 3 Options I_1_I 2 = Panic Keys Disabled with
37 Keypad 4 Options I_1_I Silent Entry, Exit & Trouble
3 = Panic Keys Enabled with
Silent Entry, Exit & Trouble

Zone Programming
Location Feature Variables
38 Zone 1 Type I_1_I 0 = Not Used
42 Zone 2 Type I_1_I 1 = Burglar
46 Zone 3 Type I_1_I 2 = 24 Hr Fire
50 Zone 4 Type I_1_I 3 = 24 Hr Holdup
54 Zone 5 Type I_1_I 4 = 24 Hr Auxiliary
58 Zone 6 Type I_1_I 5 = Momentary Keyswitch
62 Zone 7 Type I_1_I 6 = 24 Hr Communicator
66 Zone 8 Type I_1_I 7 = Momentary Smoke Reset

39 Zone 1 Response I_13_I 0 = Instant, Arm AWAY
43 Zone 2 Response I_3_I 1 = Delay 1, Arm AWAY
44 Zone 3 Response I_3_I 2 = Delay 2, Arm AWAY
51 Zone 4 Response I_12_I 3 = Follower, Arm AWAY
55 Zone 5 Response I_12_I 4 = Instant, Arm AWAY & STAY
59 Zone 6 Response I_12_I 5 = Delay 1, Arm AWAY & STAY
63 Zone 7 Response I_12_I 6 = Delay 2, Arm AWAY & STAY
67 Zone 8 Response I_12_I 7 = Follower, Arm AWAY & STAY
8 = Instant, Arm AWAY & NIGHT
9 = Delay 1, Arm AWAY & NIGHT
10 = Delay 2, Arm AWAY & NIGHT
11 = Follower, Arm AWAY & NIGHT
12 = Instant, Arm AWAY, STAY & NIGHT
13 = Delay 1, Arm AWAY, STAY & NIGHT
14 = Delay 2, Arm AWAY, STAY & NIGHT
15 = Follower, Arm AWAY, STAY & NIGHT

40 Zone 1 Option I_1_I 0 = Hardwire Zone, Not Bypassable
44 Zone 2 Option I_1_I 1 = Hardwire Zone, Bypassable
48 Zone 3 Option I_1_I 2 = Wireless Zone, Not Bypassable
52 Zone 4 Option I_1_I 3 = Wireless Zone, Bypassable
56 Zone 5 Option I_1_I 4 = Hardwire Fast Zone, Not Bypassable
60 Zone 6 Option I_1_I 5 = Hardwire Fast Zone, Not Bypassable
64 Zone 7 Option I_1_I
68 Zone 8 Option I_1_I

41 Zone 1 Supervision I_2_I 0 = Alarm on Open, No Trble (EOL Optional)
45 Zone 2 Supervision I_2_I 1 = Alarm on Short, No Trble (EOL Optional
49 Zone 3 Supervision I_2_I 2 = Alarm Open or Short, No Trble (EOL Opt.)
53 Zone 4 Supervision I_2_I 3 = Alarm on Open or Short
57 Zone 5 Supervision I_2_I 4 = Alarm on Open, Trble on Short
61 Zone 6 Supervision I_2_I 5 = Alarm on Short, Trble on Open
65 Zone 7 Supervision I_2_I 6 = Alarm on Open or Short, Trouble on
69 Zone 8 Supervision I_2_I Open Disarmed (Burglar Only)

User Code Options
(User Codes cannot be programmed in Installer Mode)
Location Feature Variables
70 User 1 Authority Level I_1_I 0 = Disabled
71 User 2 Authority Level I_1_I 1 = Master
72 User 3 Authority Level I_1_I 2 = Duress
73 User 4 Authority Level I_1_I 3 = Maid
74 User 5 Authority Level I_1_I 4 = User on Premise (Standard User)            
75 User 6 Authority Level I_1_I 5 = Installer
76 User 7 Authority Level I_1_I
77 User 8 Authority Level I_1_I
78 User 9 Authority Level
(Installer)
I_5_I

Ouput Programming
(Outputs are on optional ZXOUT external Module)
Location Feature Variables
79 Control PGm1 I_10_I 0 = Not Used
80 Output 01 I_6_I 1 = Fire Alarm Indicator
81 Output 02 I_1_I 2 = Duress
82 Output 03 I_7_I 3 = Low Battery
83 Output 04 I_8_I 4 = Failed to Communicate
84 Output 05 I_12_I 5 = Telco Line Fault
85 Output 06 I_14_I 6 = Burglar Alarm Indicator
86 Output 07 I_11_I 7 = Holdup Alarm Indicator
87 Output 08 I_13_I 8 = Auxiliary Alarm Indicator
88 Output 09 I_15_I 9 = Bell Output Trigger
89 Output 10
15 is for X-10, On during Entry/Exit
On for 5 minutes
I_17_I 10 = Violation
11 = Ready
12 = Armed
13 = Trouble
14 = Chime
15 = Lamp Trigger
16 = RF Annunicator
17 = Access Output

Communicator Programming
Location Feature Variables
90 Enable Communicator I_1_I 0 = Disabled
1 = Enabled
2 = Enabled w/Telco Line Monitor
91 Disable Call Waiting I_0_I 0 = No, 1 = Yes
92 Days Between Comm Tests I_1_I 0 to 255 Days
93 Time Between Calls I_5_I 0 to 255 Seconds
94 Telephone 1 Trans. Format I_3_I 0 = Pulsed 20 Baud, Non-Extended
95 Telephone 2 Trans. Format I_3_I 1 = Pulsed 20 Baud, Extended
2 = Pulsed 40 Baud Extended
3 = Contact ID
4 = Pager (Telephone 2 only)

96 Dialer Type I_1_I 0 = Pulse, 1 = Tone, 2 = Euro Pulse
97 Telephone 1 Dial Attempts I_5_I 1 to 15 Attempts
98 Telephone 2 Dial Attemps I_5_I 1 to 15 Attempts
99 ON-Hook Time I_5_I 1 to 15 Seconds
100 OFF-Hook Time I_3_I 1 to 15 Seconds

101 Alarms/Restores Call Routing I_3_I 0 = Do Not report
102 Zone Bypass/Restore Call Routing I_0_I 1 = Phone 1 Only
103 Open/Close Call Routing I_0_I 2 = Phone 2 Only
104 Trouble/Restore Call Routing I_0_I 3 = Phone 1 (2 on Failure)
105 System Maintenance Call Routing I_0_I 4 = Phone 2 (1 on Failure)
5 = Phone 1 and 2

106-121 Telephone Number 1 (16 digits, default = FFFF)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
(A = 0 in Phone number B (11) = * C (12) = # D or E (14) = 3 Second Pause F (15) = End Phone Number)

122-145 Telephone Number 2 (24 digits, default = FFFF)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
(If Pager add 2 or 3 D’s or E’s to allow pausing before sending pager info)

146-161 RPM (Download) Telephone Number (16 digits, default = FFFF)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I

162-165 Telephone 1 Account Number I_ _I_ _I_ _I_ _I
(4 Hex digits 0000 to FFFF, enter A for 0’s)

166-169 Telephone 2 Account Number I_ _I_ _I_ _I_ _I
Hex Program 10 = A 11 = B 12 = C 13 = D 14 = E 15 = F

Report Code Programming
Location Feature Variables
170 Zone 01 Alarm I_3_I 0 (No Report) to F
171 Zone 02 Alarm I_3_I 0 (No Report) to F
172 Zone 03 Alarm I_3_I 0 (No Report) to F
173 Zone 04 Alarm I_3_I 0 (No Report) to F
174 Zone 05 Alarm I_3_I 0 (No Report) to F
175 Zone 06 Alarm I_3_I 0 (No Report) to F
176 Zone 07 Alarm I_3_I 0 (No Report) to F
177 Zone 08 Alarm I_3_I 0 (No Report) to F
178 Zone Restoral Report Code I_0_I 0 (No Report) to F
179 Zone Bypass Report Code I_0_I 0 (No Report) to F
180 Zone Troubles Report Code I_0_I 0 (No Report) to F

181 Exit Alarm Report Code I_0_I 0 (No Report) to F
182 Closing Report Code I_0_I 0 (No Report) to F
183 Opening Report Cod I_0_I 0 (No Report) to F
184 Duress Report Code I_9_I 0 (No Report) to F
185 Cancel Report Code I_0_I 0 (No Report) to F
186 Recent Closings I_0_I 0 (No Report) to F
187 User on Premise I_0_I 0 (No Report) to F

188 Aux Alarm Report Code I_9_I 0 (No Report) to F
189 ‘A’ (Fire) Panic Report Code I_1_I 0 (No Report) to F
190 ‘B’ (Police) Panic Report Code I_2_I 0 (No Report) to F
191 ‘C’ Medical Alarm Report Code I_4_I 0 (No Report) to F

192 All Other Troubles Report Code I_F_I 0 (No Report) to F
193 Fire Test Begin Report Code I_0_I 0 (No Report) to F
194 Keypad Missing Report Code I_0_I 0 (No Report) to F
195 AC Failure Report Code I_A_I 0 (No Report) to F
196 Panel Low Battery Report Code I_9_I 0 (No Report) to F
197 Bell Fault Report Code I_0_I 0 (No Report) to F
198 Memory Error Report Code I_0_I 0 (No Report) to F
199 RF Jamming Report Code I_0_I 0 (No Report) to F
200 RF Keyfob Low Batt Report Code I_0_I 0 (No Report) to F
201 Installer On Premise Report Code I_0_I 0 (No Report) to F
202 Trouble Restore Report Code I_0_I 0 (No Report) to F
203 Fire Test End Report Code I_0_I 0 (No Report) to F
204 Keypad Restore Report Code I_0_I 0 (No Report) to F
205 AC Restore Report Code I_A_I 0 (No Report) to F
207 Bell Restore Report Code I_0_I 0 (No Report) to F
208 Communication Restore I_0_I 0 (No Report) to F
209 RF Channel Clear I_0_I 0 (No Report) to F
210 Installer Off Premise I_0_I 0 (No Report) to F

211 Other Events Report Code I_0_I 0 (No Report) to F
212 Comm Test Failure Report Code I_0_I 0 (No Report) to F
213 Comm Test Report Code I_0_I 0 (No Report) to F
214 RPM Download End Report Code I_0_I 0 (No Report) to F
215 RPM Download Aborted Report Code I_0_I 0 (No Report) to F