Misc Options |
Location |
Feature |
|
Variables |
1 |
Away Exit Delay Time |
I_60_I |
0 to 255 Seconds |
2 |
Stay/Night Exit Delay Time |
I_60_I |
0 to 255 Seconds |
3 |
Entry Delay Time 1 |
I_30_I |
0 to 255 Seconds |
4 |
Entry Delay Time 2 |
I_40_I |
0 to 255 Seconds |
5 |
Fire Alarm Cutoff Time |
I_6_I |
0 to 255 Seconds |
6 |
Other Alarms Cutoff Time |
I_6_I |
0 to 255 Seconds |
7 |
Access Time |
I_5_I |
0 to 255 Seconds |
8 |
Delay Before Dial Timer |
I_0_I |
0 to 255 Seconds |
9 |
Fire Delay Before Dial Timer |
I_0_I |
0 to 255 Seconds |
10 |
AC Failure Delay Timer |
I_60_I |
0 to 255 Seconds
|
11 |
Burglar Audible Lockout |
I_3_I |
0 to 15 Alarms |
12 |
Swinger Shutdown |
I_3_I |
0 to 15 Violations |
13 |
Passcode Entry Lockout |
I_8_I |
0 to 15 Attempts
|
14 |
Rings Until Answer |
I_5_I |
0 to 15 Rings |
15 |
Second Call Bypass Timer |
I_60_I |
0 to 255 seconds, default = 15
|
16 |
Holdup Alarms (B Key) |
I_0_I |
0 = No Sounder Output |
17 |
Auxiliary Alarms (C Key) |
I_1_I |
1 = Keypad Sounder Only |
18 |
Burglar Alarms |
I_2_I |
2 = Keypad Sounder + Bell Output
|
19 |
Enable Bypassing |
I_1_I |
0 = No, 1 = Yes |
20 |
Enable Force Arming |
I_0_I |
0 = No, 1 = Yes |
21 |
Enable Two-Button Arming |
I_0_I |
0 = No, 1 = Yes |
22 |
Enable Double-Press Arming |
I_0_I |
0 = No, 1 = Yes |
23 |
Opening Report Only After Alarm |
I_0_I |
0 = No, 1 = Yes |
24 |
Enable Remote Programming |
I_1_I |
0 = No, 1 = Yes |
25 |
Enable Programming At Power-Up |
I_0_I |
0 = No, 1 = Yes |
26 |
Lockout Installer Programming |
I_0_I |
0 = No, 1 = Yes |
27 |
Fire Bell |
I_1_I |
0 = Steady, 1 = Pulsed |
28 |
Burglar Bell |
I_0_I |
0 = Steady, 1 = Pulsed |
29 |
Holdup Bell |
I_0_I |
0 = Steady, 1 = Pulsed |
30 |
Auxiliary Bell |
I_0_I |
0 = Steady, 1 = Pulsed |
31 |
Bell Test On Away Arm |
I_0_I |
0 = No, 1 = Yes |
32 |
Display Bypassed While Armed |
I_0_I |
0 = No, 1 = Yes |
33 |
Two Wire Smoke Enable |
I_0_I |
0 = No, 1 = Yes (Zone 8 only)
|
34 |
Keypad 1 Options |
I_1_I |
0 = Panic Keys Disabled |
35 |
Keypad 2 Options |
I_1_I |
1 = Panic Keys Enabled |
36 |
Keypad 3 Options |
I_1_I |
2 = Panic Keys Disabled with |
37 |
Keypad 4 Options |
I_1_I |
Silent Entry, Exit & Trouble
3 = Panic Keys Enabled with
Silent Entry, Exit & Trouble
|
Zone Programming |
Location |
Feature |
|
Variables |
38 |
Zone 1 Type |
I_1_I |
0 = Not Used |
42 |
Zone 2 Type |
I_1_I |
1 = Burglar |
46 |
Zone 3 Type |
I_1_I |
2 = 24 Hr Fire |
50 |
Zone 4 Type |
I_1_I |
3 = 24 Hr Holdup |
54 |
Zone 5 Type |
I_1_I |
4 = 24 Hr Auxiliary |
58 |
Zone 6 Type |
I_1_I |
5 = Momentary Keyswitch |
62 |
Zone 7 Type |
I_1_I |
6 = 24 Hr Communicator |
66 |
Zone 8 Type |
I_1_I |
7 = Momentary Smoke Reset
|
39 |
Zone 1 Response |
I_13_I |
0 = Instant, Arm AWAY |
43 |
Zone 2 Response |
I_3_I |
1 = Delay 1, Arm AWAY |
44 |
Zone 3 Response |
I_3_I |
2 = Delay 2, Arm AWAY |
51 |
Zone 4 Response |
I_12_I |
3 = Follower, Arm AWAY |
55 |
Zone 5 Response |
I_12_I |
4 = Instant, Arm AWAY & STAY |
59 |
Zone 6 Response |
I_12_I |
5 = Delay 1, Arm AWAY & STAY |
63 |
Zone 7 Response |
I_12_I |
6 = Delay 2, Arm AWAY & STAY |
67 |
Zone 8 Response |
I_12_I |
7 = Follower, Arm AWAY & STAY
8 = Instant, Arm AWAY & NIGHT
9 = Delay 1, Arm AWAY & NIGHT
10 = Delay 2, Arm AWAY & NIGHT
11 = Follower, Arm AWAY & NIGHT
12 = Instant, Arm AWAY, STAY & NIGHT
13 = Delay 1, Arm AWAY, STAY & NIGHT
14 = Delay 2, Arm AWAY, STAY & NIGHT
15 = Follower, Arm AWAY, STAY & NIGHT
|
40 |
Zone 1 Option |
I_1_I |
0 = Hardwire Zone, Not Bypassable |
44 |
Zone 2 Option |
I_1_I |
1 = Hardwire Zone, Bypassable |
48 |
Zone 3 Option |
I_1_I |
2 = Wireless Zone, Not Bypassable |
52 |
Zone 4 Option |
I_1_I |
3 = Wireless Zone, Bypassable |
56 |
Zone 5 Option |
I_1_I |
4 = Hardwire Fast Zone, Not Bypassable |
60 |
Zone 6 Option |
I_1_I |
5 = Hardwire Fast Zone, Not Bypassable |
64 |
Zone 7 Option |
I_1_I |
68 |
Zone 8 Option |
I_1_I
|
41 |
Zone 1 Supervision |
I_2_I |
0 = Alarm on Open, No Trble (EOL Optional) |
45 |
Zone 2 Supervision |
I_2_I |
1 = Alarm on Short, No Trble (EOL Optional |
49 |
Zone 3 Supervision |
I_2_I |
2 = Alarm Open or Short, No Trble (EOL Opt.) |
53 |
Zone 4 Supervision |
I_2_I |
3 = Alarm on Open or Short |
57 |
Zone 5 Supervision |
I_2_I |
4 = Alarm on Open, Trble on Short |
61 |
Zone 6 Supervision |
I_2_I |
5 = Alarm on Short, Trble on Open |
65 |
Zone 7 Supervision |
I_2_I |
6 = Alarm on Open or Short, Trouble on |
69 |
Zone 8 Supervision |
I_2_I |
Open Disarmed (Burglar Only)
|
User Code Options
(User Codes cannot be programmed in Installer Mode)
|
Location |
Feature |
|
Variables |
70 |
User 1 Authority Level |
I_1_I |
0 = Disabled |
71 |
User 2 Authority Level |
I_1_I |
1 = Master |
72 |
User 3 Authority Level |
I_1_I |
2 = Duress |
73 |
User 4 Authority Level |
I_1_I |
3 = Maid |
74 |
User 5 Authority Level |
I_1_I |
4 = User on Premise (Standard User) |
75 |
User 6 Authority Level |
I_1_I |
5 = Installer |
76 |
User 7 Authority Level |
I_1_I |
77 |
User 8 Authority Level |
I_1_I |
78 |
User 9 Authority Level
(Installer)
|
I_5_I
|
Ouput Programming
(Outputs are on optional ZXOUT external Module)
|
Location |
Feature |
|
Variables |
79 |
Control PGm1 |
I_10_I |
0 = Not Used |
80 |
Output 01 |
I_6_I |
1 = Fire Alarm Indicator |
81 |
Output 02 |
I_1_I |
2 = Duress |
82 |
Output 03 |
I_7_I |
3 = Low Battery |
83 |
Output 04 |
I_8_I |
4 = Failed to Communicate |
84 |
Output 05 |
I_12_I |
5 = Telco Line Fault |
85 |
Output 06 |
I_14_I |
6 = Burglar Alarm Indicator |
86 |
Output 07 |
I_11_I |
7 = Holdup Alarm Indicator |
87 |
Output 08 |
I_13_I |
8 = Auxiliary Alarm Indicator |
88 |
Output 09 |
I_15_I |
9 = Bell Output Trigger |
89 |
Output 10
15 is for X-10, On during Entry/Exit
On for 5 minutes
|
I_17_I |
10 = Violation
11 = Ready
12 = Armed
13 = Trouble
14 = Chime
15 = Lamp Trigger
16 = RF Annunicator
17 = Access Output
|
Communicator Programming |
Location |
Feature |
|
Variables |
90 |
Enable Communicator |
I_1_I |
0 = Disabled
1 = Enabled
2 = Enabled w/Telco Line Monitor
|
91 |
Disable Call Waiting |
I_0_I |
0 = No, 1 = Yes |
92 |
Days Between Comm Tests |
I_1_I |
0 to 255 Days |
93 |
Time Between Calls |
I_5_I |
0 to 255 Seconds |
94 |
Telephone 1 Trans. Format |
I_3_I |
0 = Pulsed 20 Baud, Non-Extended |
95 |
Telephone 2 Trans. Format |
I_3_I |
1 = Pulsed 20 Baud, Extended
2 = Pulsed 40 Baud Extended
3 = Contact ID
4 = Pager (Telephone 2 only)
|
96 |
Dialer Type |
I_1_I |
0 = Pulse, 1 = Tone, 2 = Euro Pulse |
97 |
Telephone 1 Dial Attempts |
I_5_I |
1 to 15 Attempts |
98 |
Telephone 2 Dial Attemps |
I_5_I |
1 to 15 Attempts |
99 |
ON-Hook Time |
I_5_I |
1 to 15 Seconds |
100 |
OFF-Hook Time |
I_3_I |
1 to 15 Seconds
|
101 |
Alarms/Restores Call Routing |
I_3_I |
0 = Do Not report |
102 |
Zone Bypass/Restore Call Routing |
I_0_I |
1 = Phone 1 Only |
103 |
Open/Close Call Routing |
I_0_I |
2 = Phone 2 Only |
104 |
Trouble/Restore Call Routing |
I_0_I |
3 = Phone 1 (2 on Failure) |
105 |
System Maintenance Call Routing |
I_0_I |
4 = Phone 2 (1 on Failure)
5 = Phone 1 and 2
|
106-121 |
Telephone Number 1 (16 digits, default = FFFF)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
(A = 0 in Phone number B (11) = * C (12) = # D or E (14) = 3 Second Pause F (15) = End Phone Number)
|
122-145 |
Telephone Number 2 (24 digits, default = FFFF)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
(If Pager add 2 or 3 D’s or E’s to allow pausing before sending pager info)
|
146-161 |
RPM (Download) Telephone Number (16 digits, default = FFFF)
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
|
162-165 |
Telephone 1 Account Number |
I_ _I_ _I_ _I_ _I
(4 Hex digits 0000 to FFFF, enter A for 0’s)
|
166-169 |
Telephone 2 Account Number |
I_ _I_ _I_ _I_ _I
Hex Program 10 = A 11 = B 12 = C 13 = D 14 = E 15 = F
|
Report Code Programming |
Location |
Feature |
|
Variables |
170 |
Zone 01 Alarm |
I_3_I |
0 (No Report) to F |
171 |
Zone 02 Alarm |
I_3_I |
0 (No Report) to F |
172 |
Zone 03 Alarm |
I_3_I |
0 (No Report) to F |
173 |
Zone 04 Alarm |
I_3_I |
0 (No Report) to F |
174 |
Zone 05 Alarm |
I_3_I |
0 (No Report) to F |
175 |
Zone 06 Alarm |
I_3_I |
0 (No Report) to F |
176 |
Zone 07 Alarm |
I_3_I |
0 (No Report) to F |
177 |
Zone 08 Alarm |
I_3_I |
0 (No Report) to F |
178 |
Zone Restoral Report Code |
I_0_I |
0 (No Report) to F |
179 |
Zone Bypass Report Code |
I_0_I |
0 (No Report) to F |
180 |
Zone Troubles Report Code |
I_0_I |
0 (No Report) to F
|
181 |
Exit Alarm Report Code |
I_0_I |
0 (No Report) to F |
182 |
Closing Report Code |
I_0_I |
0 (No Report) to F |
183 |
Opening Report Cod |
I_0_I |
0 (No Report) to F |
184 |
Duress Report Code |
I_9_I |
0 (No Report) to F |
185 |
Cancel Report Code |
I_0_I |
0 (No Report) to F |
186 |
Recent Closings |
I_0_I |
0 (No Report) to F |
187 |
User on Premise |
I_0_I |
0 (No Report) to F
|
188 |
Aux Alarm Report Code |
I_9_I |
0 (No Report) to F |
189 |
‘A’ (Fire) Panic Report Code |
I_1_I |
0 (No Report) to F |
190 |
‘B’ (Police) Panic Report Code |
I_2_I |
0 (No Report) to F |
191 |
‘C’ Medical Alarm Report Code |
I_4_I |
0 (No Report) to F
|
192 |
All Other Troubles Report Code |
I_F_I |
0 (No Report) to F |
193 |
Fire Test Begin Report Code |
I_0_I |
0 (No Report) to F |
194 |
Keypad Missing Report Code |
I_0_I |
0 (No Report) to F |
195 |
AC Failure Report Code |
I_A_I |
0 (No Report) to F |
196 |
Panel Low Battery Report Code |
I_9_I |
0 (No Report) to F |
197 |
Bell Fault Report Code |
I_0_I |
0 (No Report) to F |
198 |
Memory Error Report Code |
I_0_I |
0 (No Report) to F |
199 |
RF Jamming Report Code |
I_0_I |
0 (No Report) to F |
200 |
RF Keyfob Low Batt Report Code |
I_0_I |
0 (No Report) to F |
201 |
Installer On Premise Report Code |
I_0_I |
0 (No Report) to F |
202 |
Trouble Restore Report Code |
I_0_I |
0 (No Report) to F |
203 |
Fire Test End Report Code |
I_0_I |
0 (No Report) to F |
204 |
Keypad Restore Report Code |
I_0_I |
0 (No Report) to F |
205 |
AC Restore Report Code |
I_A_I |
0 (No Report) to F |
207 |
Bell Restore Report Code |
I_0_I |
0 (No Report) to F |
208 |
Communication Restore |
I_0_I |
0 (No Report) to F |
209 |
RF Channel Clear |
I_0_I |
0 (No Report) to F |
210 |
Installer Off Premise |
I_0_I |
0 (No Report) to F
|
211 |
Other Events Report Code |
I_0_I |
0 (No Report) to F |
212 |
Comm Test Failure Report Code |
I_0_I |
0 (No Report) to F |
213 |
Comm Test Report Code |
I_0_I |
0 (No Report) to F |
214 |
RPM Download End Report Code |
I_0_I |
0 (No Report) to F |
215 |
RPM Download Aborted Report Code |
I_0_I |
0 (No Report) to F |