Moose Z911 Trouble
POWER | ON | Normal |
OFF | No AC Power | |
Flashing | Backup battery low | |
READY | ON | Zones closed, Ready to Arm |
OFF | One or more Zones are open (see Status Command) | |
Slow Flash | One or more Zones are Bypassed | |
Fast Flash | Burg Zone open and at least 1 zone is bypassed | |
ARMED | ON | System is Armed |
OFF | System is Disarmed | |
Flashing | System had an Alarm | |
INTERIOR | ON | Interior Zones are Enabled |
OFF | Interior Zones are Disabled | |
ON Flashing | System has Failed to Communicate | |
OFF Flashing | Panic B (Fire) was activated | |
DELAY | ON | Entry Delay on exterior Zones normal |
OFF | Entry Delay on exterior Zones OFF | |
ON Flashing | Internal System failure | |
OFF Flashing | Panic C (Medical) was activated | |
Fire Light | ON | Panic A (Fire) was activated |
OFF | Normal | |
Flashing | Panic A (Fire) or a supervisory zone is in Trouble | |
All Lights | Scrolling | Keypad wire broken or internal trouble |
Flashing | System in Program Mode | |
1st 7 Lights | Flashing | Program Mode entered and system is in Download Mode |
Reset Smoke |
7 + User Code + * (If this does NOT reset smoke set for service, smoke is bad) |
|
Sensor Test | 8 + User Code, open door/windows, keypad beeps, press * to end |