Moose Z800 / Z950 Program

Click HERE for Binary Programming
Move to location Location + # * Saves # Moves to next Location
There are 2 sections of programming, User and Installer sections
Installer Program (Locations 024 to 023)

1. Hold 9 key 3 seconds until keypad beeps
2. Enter Installer Code (9 6 3 2 1) (Keypad should flash)
OR (If Installer Code was changed)
1. Power down then power up
2. Hold 3 and 9 keys for 3 seconds (Keypad should flash)
(Must exit Installer Program then enter User Program to add Codes, change Entry/Exit & Siren times)
User Program (Locations 001 to 033)
1. Hold 9 key 3 seconds until keypad beeps
2. Enter Master Code (Keypad should flash)
Go to Location 1, 2 or 3 digit Location then #
Program Location After each digit entered press * to save then # to move to next location
(To program Account 1224 press 060# to enter location then 1*# 2*# 2*# 4*#
Exit Program Press * twice
Default Panel Enter programming then press 3 3 3 + # + 1 + *

USER LEVEL PROGRAMMING
1# Master Code I_1_I_2_I_4_I_5_I 1. Enter location 1 to 8 then #
2. Enter new code without * or #
3. System will give long tone and exit
2# User 2 Code I_ _I_ _I_ _I_ _I
3# User 3 Code I_ _I_ _I_ _I_ _I
4# User 4 Code I_ _I_ _I_ _I_ _I
5# User 5 Code I_ _I_ _I_ _I_ _I
6# User 6 Code I_ _I_ _I_ _I_ _I
7# User 7 Code I_ _I_ _I_ _I_ _I
8# User 8 Code I_ _I_ _I_ _I_ _I (Usually Hostage Code)

Below locations require entering location then # + Value then #

9# Usage Count Code 6 I_255*#_I (1 to 255 uses, 255 = Unlimited)
10# Time Until Next Communicator Test I_0*#_I (no need to program)
11# Clear Alarm Memory (No Value Required, keypad just beeps)
12# Delete User Codes 1 to 8 (Press 2 to 8 + # to delete)

13# Entry 1 Time I_30*#_I (1 to 255 seconds)
14# Entry 2 Time I_45*#_I (1 to 255 seconds)
15# Exit Time I_60*#_I (Even times give Exit Beeps)
16# Access Time I_5*#_I (1 to 255 seconds)

17# Delay Burg Output I_0*#_I (0 to 255 seconds)
18# Burg Cutoff Time I_6*#_I (1 to 255 minutes, 255 = Unlimited)                                    
19# Aux A (Fire) Panic Cutoff Time I_6*#_I (1 to 255 minutes, 255 = Unlimited)
20# Aux B (Police) Panic Cutoff Time I_6*#_I (1 to 255 minutes, 255 = Unlimited)
21# Aux C (Medical) Panic Cutoff Time I_6*#_I (1 to 255 minutes, 255 = Unlimited)
22# Time between Communicator Test I_1*#_I (0 = 12 Hours, 1 to 7 = 1 to 7 Days)
23# Go Off-Hook and Initiate Download (Answers Downloader Call)


INSTALLER LEVEL PROGRAMMING

24# Configuration User Code 1 I_3*#_I (3 = Standard user Code)
25# Configuration User Code 2 I_3*#_I
26# Configuration User Code 3 I_3*#_I
27# Configuration User Code 4 I_3*#_I
28# Configuration User Code 5 I_3*#_I
29# Configuration User Code 6 I_3*#_I
30# Configuration User Code 7 I_3*#_I
31# Configuration User Code 8 I_9*#_I (9 = Duress Code)

32# Program Output 1 Config I_15*#_I (0 to 255)
33# Program Output 2 Config I 112*#_I (0 to 255)
34# Program Output 3 Config I_0*#_I (0 to 255)
35# Program Output 4 Config I_48*#_I (0 to 255)

36# Pulse Burg Output I_0*#_I (0 = No, 1 = Yes)
37# Pulse Aux A (Fire) Output I_0*#_I (0 = No, 1 = Yes)

38# Lockout by Zone till Disarm (Swinger) I_1*#_I (0 = No, 1 = Yes)
39# Zone Supervision Config I_0*#_I (0 = No, 1 = Yes)
40# Eliminate Burg EOL Resistors I_0*#_I (0 = No, 1 = Yes)

Lights will all begin flashing, press 41 # to continue

41# Zone 1 Configuration (Zone Type) I_64*#_I (Common Zone Types)
42# Zone 2 Configuration (Zone Type) I_72*#_I 64 = Delay 1
43# Zone 3 Configuration (Zone Type) I_81*#_I 65 = Instant
44# Zone 4 Configuration (Zone Type) I_65*#_I 66 = Fire
45# Zone 5 Configuration (Zone Type) I_65*#_I 67 = Remote Panic
46# Zone 6 Configuration (Zone Type) I_65*#_I 72 = Delay 2
47# Zone 7 Configuration (Zone Type) I_65*#_I 81 = Interior Motion
48# Zone 8 Configuration (Zone Type) I_65*#_I

49# Communicator Delay/Enable I_1*#_I (1 to 255 seconds, 0 = Dialer Disabled)
50# Dial Attempts Phone 1 I_8*#_I (1 to 15 attempts)
51# Dial Attempts Phone 2 I_8*#_I (1 to 15 attempts)
52# Telephone On-Hook before Dial I_0*#_I (0 to 15 seconds)
53# Time between Dial Attempts I_10*#_I (0 to 15 seconds)
54# Abort Communicator on Disarming I_0*#_I (0 = No, 1 = Yes)
55# Disable Dialer Test on Power-Up I_0*#_I (0 = No, 1 = Yes)
56# Exception Open/Close Restore I_0*#_I (0 = No, 1 = Yes)
57# Pulse Dial 63/37 Make/Break Ratio I_0*#_I (0 = No, 1 = Yes)
58# 9 Sec Wait for Dial Tone I_0*#_I (0 = No, 1 = Yes)
59# No Dial without Dial Tone I_0*#_I (0 = No, 1 = Yes)

60# 1st Digit of Account Number I_?*#_I (Enter 10 if 0 in Account Number)

A = 10 B = 11 C = 12
D = 13 E = 14 F = 15
61# 2nd Digit of Account Number I_?*#_I
62# 3rd Digit of Account Number I_?*#_I
63# 4th Digit of Account Number I_?*#_I

64# Transmission Format I_2*#_I
0 = Autobaud, Format selected based on receiver handshake
1 = 1400Hz Handshake, 1900Hz Data, 10 Baud
2 = 2300Hz Handshake, 1800Hz Data, 20 Baud
3 = 1400 or 2300Hz Handshake, 1800Hz Data, 40 Baud
4 = 1400Hz Handshake, 1900Hz Data, 15 Baud
5 = Radionics BFSK (1400 or 2300Hz Handshake)
6 = Modem II (Auto Reporting on all but Opening/Closings)
(Enter 1 to enable, 0 to disable in Report Code sections)
7 = Sescoa Model 3000, Fast Format

65# Single Round Format I_0*#_I (0 = No, 1 = Yes)
66# 4/2 Format Enable I_1*#_I (0 = No, 1 = Yes)
67# Extended Standard I_0*#_I (0 = No, 1 = Yes)
68# Extended Single Line I_0*#_I (0 = No, 1 = Yes)
69# Parity Checksum I_0*#_I (0 = No, 1 = Yes)
70# Touchtone Dialing I_1*#_I (0 = No, 1 = Yes)

Zone Reporting
71# Zone 1 Phone Config I_1*#_I (Dial 1st Number Only)
72# Zone 1 1st Digit Report Code I_3*#_I (Sends 31)
73# Zone 1 2nd Digit Report Code I_1*#_I

0 = Do not Dial (No Report)
1 = Dial Telephone 1 Only
1st digit = Telephone Configuration 2 = Dial Telephone 2 Only
3 = Dial Telephone 1, Backup to Telephone 2
4 = Dial Telephone 1 and Telephone 2

74# Zone 2 Phone Config I_1*#_I (Dial 1st Number Only)
75# Zone 2 1st Digit Report Code I_3*#_I (Sends 32)
76# Zone 2 2nd Digit Report Code I_2*#_I

77# Zone 3 Phone Config I_1*#_I (Dial 1st Number Only)
78# Zone 3 1st Digit Report Code I_3*#_I (Sends 33)
79# Zone 3 2nd Digit Report Code I_3*#_I

80# Zone 4 Phone Config I_1*#_I (Dial 1st Number Only)
81# Zone 4 1st Digit Report Code I_3*#_I (Sends 34)
82# Zone 4 2nd Digit Report Code I_4*#_I

83# Zone 5 Phone Config I_1*#_I (Dial 1st Number Only)
84# Zone 5 1st Digit Report Code I_3*#_I (Sends 35)
85# Zone 5 2nd Digit Report Code I_5*#_I

86# Zone 6 Phone Config I_1*#_I (Dial 1st Number Only)
87# Zone 6 1st Digit Report Code I_3*#_I (Sends 36)
88# Zone 6 2nd Digit Report Code I_6*#_I

89# Zone 7 Phone Config I_1*#_I (Dial 1st Number Only)
90# Zone 7 1st Digit Report Code I_3*#_I (Sends 37)
91# Zone 7 2nd Digit Report Code I_7*#_I

92# Zone 8 Phone Config I_1*#_I (Dial 1st Number Only)
93# Zone 8 1st Digit Report Code I_3*#_I (Sends 38)
94# Zone 8 2nd Digit Report Code I_8*#_I

(If Smoke program 16)
95# Zone 1 Shunt Report Code I_0*#_I (No Reporting)
96# Zone 1 2nd Digit Shunt Report Code I_0*#_I
97# Zone 2 Shunt Report Code I_0*#_I
98# Zone 2 2nd Digit Shunt Report Code I_0*#_I
099# Zone 3 Shunt Report Code I_0*#_I
100# Zone 3 2nd Digit Shunt Report Code I_0*#_I
101# Zone 4 Shunt Report Code I_0*#_I
102# Zone 4 2nd Digit Shunt Report Code I_0*#_I
103# Zone 5 Shunt Report Code I_0*#_I
104# Zone 5 2nd Digit Shunt Report Code I_0*#_I
105# Zone 6 Shunt Report Code I_0*#_I
106# Zone 6 2nd Digit Shunt Report Code I_0*#_I
107# Zone 7 Shunt Report Code I_0*#_I
108# Zone 7 2nd Digit Shunt Report Code I_0*#_I
109# Zone 8 Shunt Report Code I_0*#_I
110# Zone 8 2nd Digit Shunt Report Code I_0*#_I

111# Zone 1 Restore Report Code I_0*#_I (No Reporting)
112# Zone 1 2nd Digit Restore Report Code I_0*#_I
113# Zone 2 Restore Report Code I_0*#_I
114# Zone 2 2nd Digit Restore Report Code I_0*#_I
115# Zone 3 Restore Report Code I_0*#_I
116# Zone 3 2nd Digit Restore Report Code I_0*#_I
117# Zone 4 Shunt Restore Code I_0*#_I
118# Zone 4 2nd Digit Restore Report Code I_0*#_I
119# Zone 5 Restore Report Code I_0*#_I
120# Zone 5 2nd Digit Restore Report Code I_0*#_I
121# Zone 6 Restore Report Code I_0*#_I
122# Zone 6 2nd Digit Restore Report Code I_0*#_I
123# Zone 7 Restore Report Code I_0*#_I
124# Zone 7 2nd Digit Restore Report Code I_0*#_I
125# Zone 8 Restore Report Code I_0*#_I
126# Zone 8 2nd Digit Restore Report Code I_0*#_I

Zone Supervisory Reporting
127# Supervisory Phone Config I_0*#_I (No Reporting)
128# Zone 1 Supervisory Code I_0*#_I
129# Zone 1 Extended Supervisory Code I_0*#_I
130# Zone 2 Supervisory Code I_0*#_I Don’t worry about 128 to 143
131# Zone 2 Extended Supervisory Code I_0*#_I if 127 is set to 0 (No Reporting)
132# Zone 3 Supervisory Code I_0*#_I
133# Zone 3 Extended Supervisory Code I_0*#_I
134# Zone 4 Supervisory Code I_0*#_I
135# Zone 4 Extended Supervisory Code I_0*#_I
136# Zone 5 Supervisory Code I_0*#_I
137# Zone 5 Extended Supervisory Code I_0*#_I
138# Zone 6 Supervisory Code I_0*#_I
139# Zone 6 Extended Supervisory Code I_0*#_I
140# Zone 7 Supervisory Code I_0*#_I
141# Zone 7 Extended Supervisory Code I_0*#_I
142# Zone 8 Supervisory Code I_0*#_I (If Smoke on Zn 8 use 7)
143# Zone 8 Extended Supervisory Code I_0*#_I (If Smoke on Zn 8 use 6, sends 76)

Misc. Report Codes
144# Keypad Fire Phone Config I_1*#_I (Dial 1st Number Only)
145# Keypad Fire Report Code I_2*#_I (Sends 23)
146# Keypad Fire 2nd Digit Report Code I_3*#_I
147# Keypad Fire Restore Report Code I_0*#_I (No Reporting)
148# Keypad Fire 2nd Digit Restore Code I_0*#_I

149# Keypad Police Phone Config I_1*#_I (Dial 1st Number Only)
150# Keypad Police Report Code I_2*#_I (Sends 21)
151# Keypad Police 2nd Digit Report Code I_1*#_I
152# Keypad Police Restore Report Code I_0*#_I (No Reporting)
153# Keypad Police 2nd Digit Restore Code I_0*#_I

154# Keypad Aux Phone Config I_1*#_I (Dial 1st Number Only)
155# Keypad Aux Report Code I_2*#_I (Sends 26)
156# Keypad Aux 2nd Digit Report Code I_6*#_I
157# Kypad Aux Restore Report Code I_0*#_I (No Reporting)
158# Kypad Aux 2nd Digit Restore Code I_0*#_I

159# Keypad Duress Phone Config I_1*#_I (Dial 1st Number Only)
160# Keypad Duress Report Code I_2*#_I (Sends 22)
161# Keypad Duress 2nd Digit Report Code I_2*#_I
162# Keypad Duress Restore Report Code I_0*#_I (No Reporting)
163# Keypad Duress 2nd Digit Restore Code I_0*#_I

Opening/Closing Report Codes
164# Opening/Closing Phone Config I_0*#_I (Dial 1st Number Only)
165# User 1 Open Report Code I_0*#_I (No Reporting)
166# User 1 Open Extended Report Code I_0*#_I
167# User 2 Open Report Code I_0*#_I
168# User 2 Open Extended Report Code I_0*#_I
169# User 3 Open Report Code I_0*#_I
170# User 3 Open Extended Report Code I_0*#_I
171# User 4 Open Report Code I_0*#_I
172# User 4 Open Extended Report Code I_0*#_I
173# User 5 Open Report Code I_0*#_I
174# User 5 Open Extended Report Code I_0*#_I
175# User 6 Open Report Code I_0*#_I
176# User 6 Open Extended Report Code I_0*#_I
177# User 7 Open Report Code I_0*#_I
178# User 7 Open Extended Report Code I_0*#_I
179# User 8 Open Report Code I_0*#_I
180# User 8 Open Extended Report Code I_0*#_I

181# Keyswitch Open Report Code I_0*#_I (No Reporting)
182# Keyswitch 2nd Dgt Open Report I_0*#_I

183# User 1 Close Report Code I_0*#_I (No Reporting)
184# User 1 Close Extended Report Code I_0*#_I
185# User 2 Close Report Code I_0*#_I
186# User 2 Close Extended Report Code I_0*#_I
187# User 3 Close Report Code I_0*#_I
188# User 3 Close Extended Report Code I_0*#_I
189# User 4 Close Report Code I_0*#_I
190# User 4 Close Extended Report Code I_0*#_I
191# User 5 Close Report Code I_0*#_I
192# User 5 Close Extended Report Code I_0*#_I
193# User 6 Close Close I_0*#_I
194# User 6 Close Extended Report Code I_0*#_I
195# User 7 Close Report Code I_0*#_I
196# User 7 Close Extended Report Code I_0*#_I
197# User 8 Close Report Code I_0*#_I
198# User 8 Close Extended Report Code I_0*#_I

199# Keyswitch Close Report Code I_0*#_I
200# Keyswitch 2nd Digit Close Report Code I_0*#_I

201# Cancel Phone Config I_0*#_I (No Reporting)
202# Cancel Report Code I_0*#_I
203# Cancel 2nd Digit Report Code I_0*#_I

204# Abort Phone Config I_0*#_I (No Reporting)
205# Abort Report Code I_0*#_I
206# Abort 2nd Digit Report Code I_0*#_I

207# Low Bat Phone Config I_1*#_I (Dial 1st Phone Only)
208# Low Bat Report Code I_7*#_I (Sends 78)
209# Low Bat 2nd Digit Report Code I_8*#_I
210# Low Bat Restore Report Code I_0*#_I
211# Low Bat Rest 2nd Digit Report Code I_0*#_I

212# AC Fail Phone Config I_1*#_I (Dial 1st Phone Only)
213# AC Fail Report Code I_7*#_I (Sends 79)
214# AC Fail 2nd Digit Report Code I_9*#_I
215# AC Fail Restore Report Code I_0*#_I
216# AC Fail Restore 2nd Digit Report Code I_0*#_I

217# Missing KP Phone Config I_0*#_I (No Reporting)
218# Missing KP Report Code I_0*#_I
219# Missing KP 2nd Digit Report Code I_0*#_I

220# Test Phone Config I_0*#_I (No Reporting)
221# Test Report Code I_0*#_I
222# Test 2nd Digit Report Code I_0*#_I

223# Up/Download Complete Phone Config I_0*#_I (No Reporting)
224# Up/Download Complete Report Code I_0*#_I
225# Up/Download 2nd Comp. Digit Code I_0*#_I
226# Up/Download Denied Phone Config I_0*#_I (No Reporting)
227# Up/Download Denied Report Code I_0*#_I
228# Up/Download Denied 2nd Digit Code I_0*#_I

229# to 244# Receiver Telephone 1 Program as 1* # 8* # 0* # 0* # etc

I _1*#_ I _8*#_ I _?*#_ I _?*#_ I _?*#_ I _?*#_ I _?*#_ I _?*#_ I _?*#_ I _?*#_ I _?*#_ I _?*#_ I _?*#_ I _?*#_ I _?*#_ I _?*#_ I
229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244

11 = *
12 = #
13 = 3 Second Pause
14 = Wait for Dial Tone
15 = End Phone Number

245# Reserved for Future Use I_#_I
246# Copy Telephone 1 to Telephone 2 I_#_I
247# Copy Telphone 1 Pgrm to Telephone 2 I_#_I No Value Required
(Press 246# then 247# as quick way of removing old Telephone 2 Programming)
248# to 277# Receiver Telephone 2 (Not Used)
278# Answering Machine Double Call timer I_6*#_I (0 to 15 x10 seconds)
279# Number of Rings before Answering I_12*#_I (0 to 15 rings)
280# to 296# Download Telephone Number

I _ _ I _ _ I _ _ I _ _ I _ _ I _ _ I _ _ I _ _ I _ _ I _ _ I _ _ I _ _ I _ _ I _ _ I _ _ I _ _ I
280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295

296# Reserved for Future Use (Do not Program)
297# Installer Code I_96321_I (Enter 96543#)
298# Restore User Code 1 to Default (No value required, keypad just beeps)
299# Two Digit Arming I_0*#_I (0 = No, 1 = Yes)
300# Enable Force Arming I_0*#_I (0 = No, 1 = Yes)
301# Permanent Force Arming I_0*#_I (0 = No, 1 = Yes)
302# Delay Burg Rest Until Cutoff I_0*#_I (0 = No, 1 = Yes)
303# Alarm Reports Until Lockout (Swinger) I_3*#_I (0 to 15 Alarms)
304# Burg Loop Audible Lockout I_0*#_I (0 = No, 1 = Yes)
305# Keyswitch Mode Change I_0*#_I (0 = No, 1 = Yes)
306# Supervisory/Day Alert Latch I_0*#_I (0 = No, 1 = Yes)
307# Automatic Interior Home/Away Off I_0*#_I (0 = No, 1 = Yes)
308# Extend BA Loop Stabilization I_0*#_I (0 = No, 1 = Yes)
309# Disable Interior Follower I_0*#_I (0 = No, 1 = Yes)
310# Interior On/Off if Armed I_0*#_I (0 = No, 1 = Yes)
311# Delay Off When Interior Off I_0*#_I (0 = No, 1 = Yes)
312# Siren Test on Arming I_0*#_I (0 = No, 1 = Yes)
313# Reset Test Timer on Kissoff I_0*#_I (0 = No, 1 = Yes)
314# Interior Default Upon Disarm I_0*#_I (0 = No, 1 = Yes)
315# Keypad Panic Hold 3 seconds Mode I_0*#_I 0 = Press twice
1 = Hold 3 seconds
Function Key Options

316# Disable Keypad Fire Panic I_0*#_I (0 = No, 1 = Yes)
317# Disable Keypad Police Panic I_0*#_I (0 = No, 1 = Yes)
318# Disable Keypad Medical Panic I_0*#_I (0 = No, 1 = Yes)
319# Disable Keypad Bypassing I_0*#_I (0 = No, 1 = Yes)
320# Disable Keypad 4 (Interior) 5 (Instant) I_0*#_I (0 = No, 1 = Yes)
321# Disable Key 6 (Chime) I_0*#_I (0 = No, 1 = Yes)
322# Disable Key 7 (Reset) I_0*#_I (0 = No, 1 = Yes)
323# Disable Key 8 (Walk Test) I_0*#_I (0 = No, 1 = Yes)
324# Silent Keypad on Burg I_0*#_I (0 = No, 1 = Yes)
325# Silent Keypad Police Panic I_0*#_I 0 = Audible Panic
1 = Silent Panic
326# Start Entry Delay on Keypad Entries I_0*#_I (0 = No, 1 = Yes)

327# Fast Loop Response Time I_2*#_I (80 ms)
328# Slow Loop Response Time I_6*#_I (320 ms)
0 = 40 ms 1 = 40 ms 2 = 80 ms 3 = 120 ms 4 = 160 ms 5 = 200 ms
6 = 320 ms 7 = 480 ms 8 = 600ms 9 = 800 ms 10 = 1 sec 11 = 2 sec
12 = 4 sec 13 = 6 sec 14 = 8 sec 15 = 10 sec

329# Zone Verification Configuration I_0*#_I (0 to 255 thinggies)
330# Zones Permitted to Self Verify I_0*#_I (0 to 255 thinggies)
331# Zone Verification Time Window I_30*#_I (0 to 255 seconds)
332# Reserved for Future Use (Do not Program)
333# Default System to Factory I_0*#_I 0 = No
1 = Yes
334# Reserved for Future Use (Do not Program)
Press * to Exit Programming