USER LEVEL PROGRAMMING |
1# |
Master Code |
I_1_I_2_I_4_I_5_I |
1. Enter location 1 to 6 then #
2. Enter new code without * or #
3. System will give long tone and exit
|
2# |
User 2 Code |
I_ _I_ _I_ _I_ _I |
3# |
User 3 Code |
I_ _I_ _I_ _I_ _I |
4# |
User 4 Code |
I_ _I_ _I_ _I_ _I |
5# |
User 5 Code |
I_ _I_ _I_ _I_ _I |
6# |
User 6 Code |
I_ _I_ _I_ _I_ _I |
(Usually Hostage Code) > |
Below locations require entering location then # + Value then # > |
7# |
Usage Count Code 6 |
I_255*#_I |
(1 to 255 uses, 255 = Unlimited) |
8# |
Time Until Next Com Test |
I_0*#_I |
(no need to program) |
9# |
Clear Alarm Memory |
(No value required) |
10# |
Delete User Codes 1 to 6 |
(Press 2 – 6 + # to delete) |
11# |
Entry Delay 1 Time |
I_30*#_I |
(1 to 255 seconds) |
12# |
Entry Delay 2 Time |
I_45*#_I |
(1 to 255 seconds) |
13# |
Exit Delay Time |
I_61*#_I |
(1 to 255 seconds) |
|
(Even numbers in Exit Delay give exit beeps, odd numbers do not) > |
14# |
Access Output Time |
I_5*#_I |
(1 to 255 seconds, 0 = Switch with Code) |
15# |
Delay Burg Output |
I_0*#_I |
(0 to 255 seconds) |
16# |
Burg Cutoff Time |
I_6*#_I |
(1 to 255 minutes, 255 = Unlimited) |
17# |
Aux A (Fire) Panic Cutoff Time |
I_6*#_I |
(1 to 255 minutes, 255 = Unlimited) |
18# |
Aux B (Police) Panic Cutoff Time |
I_6*#_I |
(1 to 255 minutes, 255 = Unlimited) |
19# |
Aux C (Medical) Panic Cutoff Time |
I_6*#_I |
(1 to 255 minutes, 255 = Unlimited) |
20# |
Time between Communicator Test |
I_1*#_I |
(0 = Test every 12 Hours, 1 = 7 Days) |
21# |
to 32# Exits to Programming Entry Mode |
33# |
Begin Upload Data |
(Sends to Download Computer) > |
INSTALLER LEVEL PROGRAMMING > |
34# |
Configuration User Code 1 |
I_3*#_I |
(3 = Standard user Code) |
35# |
Configuration User Code 2 |
I_3*#_I |
36# |
Configuration User Code 3 |
I_3*#_I |
37# |
Configuration User Code 4 |
I_3*#_I |
38# |
Configuration User Code 5 |
I_3*#_I |
39# |
Configuration User Code 6 |
I_9*#_I |
(9 = Duress Code) > |
|
Lights will all begin flashing, press 41 # to continue > |
41# |
Zone 1 Configuration |
I_64*#_I |
64 = Delay 1 |
42# |
Zone 2 Configuration |
I_72*#_I |
65 = Instant |
43# |
Zone 3 Configuration |
I_81*#_I |
66 = Fire |
44# |
Zone 4 Configuration |
I_65*#_I |
03 = Remote Panic |
45# |
Zone 5 Configuration |
I_65*#_I |
72 = Delay #2 |
46# |
Zone 6 Configuration |
I_65*#_I |
81 = Interior Motion |
> |
47# |
Communicator Delay/Enable |
I_1*#_I |
(1 to 255 seconds, 0 = Dialer Disabled) |
48# |
Dial Attempts Phone 1 |
I_8*#_I |
(1 to 15 attempts) |
49# |
Dial Attempts Phone 2 |
I_8*#_I |
(1 to 15 attempts) |
50# |
Dual Reporting of Alarms |
I_0*#_I |
(1 = Yes, 0 = No) |
51# |
Dual Reporting of Non-Alarms |
I_0*#_I |
(1 = Yes, 0 = No) |
52# |
Communicator On-Hook Time |
I_3*#_I |
(1 to 15 seconds) |
53# |
Time between Dial Attempts |
I_10*#_I |
(1 to 255 seconds) |
54# |
Abort Communicator on Disarming |
I_0*#_I |
(1 = Yes, 0 = No) |
55# |
Disable Dialer Test on Power-Up |
I_0*#_I |
(1 = Yes, 0 = No) |
56# |
Exception Open/Close Restore |
I_0*#_I |
(1 = Yes, 0 = No) > |
57# |
1st Digit of Account Number |
I_?*#_I |
(Program 10 if Account contains a 0) |
58# |
2nd Digit of Account Number |
I_?*#_I |
A = 10, B = 11, C = 12, D = 13, E = 14, F = 15 |
59# |
3rd Digit of Account Number |
I_?*#_I |
60# |
4th Digit of Account Number |
I_?*#_I > |
61# |
Transmission Format |
I_2*#_I
0 = Autobaud, Format selected based on receiver handshake
1 = 1400Hz Handshake, 1900Hz Data, 10 Baud
2 = 2300Hz Handshake, 1800Hz Data, 20 Baud
3 = 1400 or 2300Hz Handshake, 1800Hz Data, 40 Baud
4 = 1400Hz Handshake, 1900Hz Data, 15 Baud
5 = Radionics BFSK (1400 or 2300Hz Handshake)
6 = Sescoa Model 3000, Slow Format
7 = Sescoa Model 3000, Fast Format >
|
62# |
Single Round Format |
I_0*#_I |
(1 = Yes, 0 = No) |
63# |
4/2 Format Enable |
I_1*#_I |
(1 = Yes, 0 = No) |
64# |
Extended Standard |
I_0*#_I |
(1 = Yes, 0 = No) |
65# |
Extended Single Line |
I_0*#_I |
(1 = Yes, 0 = No) |
66# |
Parity Checksum |
I_0*#_I |
(1 = Yes, 0 = No) |
67# |
Touchtone Dialing |
I_1*#_I |
(1 = Yes, 0 = No) > |
68# |
Zone 1 1st Digit Report Code |
I_3*#_I |
(Second digit is at 216, sends 31) |
69# |
Zone 2 1st Digit Report Code |
I_3*#_I |
(Second digit is at 217, sends 32) |
70# |
Zone 3 1st Digit Report Code |
I_3*#_I |
(Second digit is at 218, sends 33) |
71# |
Zone 4 1st Digit Report Code |
I_3*#_I |
(Second digit is at 219, sends 34) |
72# |
Zone 5 1st Digit Report Code |
I_3*#_I |
(Second digit is at 220, sends 35) |
73# |
Zone 6 1st Digit Report Code |
I_3*#_I |
(Second digit is at 221, sends 36) > |
74# |
KP Fire 1st Digit Report Code |
I_2*#_I |
(Second digit is at 244, sends 23) |
75# |
KP Police 1st Digit Report Code |
I_2*#_I |
(Second digit is at 245, sends 21) |
76# |
KP Medical 1st Digit Report Code |
I_2*#_I |
(Second digit is at 246, sends 26) > |
77# |
Duress 1st Digit Report Code |
I_2*#_I |
(Second digit is in 214, sends 22) |
78# |
Open 1st Digit Report Code |
I_0*#_I |
(Second digit is at 209) |
79# |
Close 1st Digit Report Code |
I_0*#_I |
(Second digit is at 209) |
80# |
Bypass 1st Digit Report Code |
I_0*#_I |
(Second digit is at 228 to 233) |
81# |
Cancel 1st Digit Report Code |
I_0*#_I |
(Do not program, it doesn’t work like you think) |
82# |
Zone Restore 1st Digit Report Code |
I_0*#_I |
(Second digit is at 222) |
83# |
Supervisory 1st Digit Report Code |
I_7*#_I |
(Second digit is at 234 to 239) |
84# |
Low Bat 1st Digit Report Code |
I_0*#_I |
(Second digit is at 241) |
85# |
Bat Restore 1st Digit Report Code |
I_0*#_I |
(second digit is at 241) |
86# |
AC Fail 1st Digit Report Code |
I_7*#_I |
(second digit is at 240) |
87# |
AC Restore 1st Digit Report Code |
I_0*#_I |
(second digit is at 240, if needed use E) |
88# |
Memory Error Report Code |
I_0*#_I |
(second digit is at 242) |
89# |
Auto Test Report Code |
I_0*#_I |
(second digit is at 243) > |
90# |
to 105# Telephone 1 (16 digits) (Program each Digit + * + # + next digit etc)
I |
_1*#_ |
I |
_8*#_ |
I |
_?*#_ |
I |
_?*#_ |
I |
_?*#_ |
I |
_?*#_ |
I |
_?*#_ |
I |
_?*#_ |
I |
_?*#_ |
I |
_?*#_ |
I |
_?*#_ |
I |
_?*#_ |
I |
_?*#_ |
I |
_?*#_ |
I |
_?*#_ |
I |
_?*#_ |
I |
|
90 |
|
91 |
|
92 |
|
93 |
|
94 |
|
95 |
|
96 |
|
97 |
|
98 |
|
99 |
|
100 |
|
101 |
|
102 |
|
103 |
|
104 |
|
105 |
|
11 = *
12 = #
13 = 3 Second Pause
14 = Wait for Dial Tone
15 = End Phone Number >
|
106# |
Audio Listen-In Phone 1 |
I_0*#_I |
(1 = Yes, 0 = No) |
108# |
Copy Telephone 1 Account to Telephone 2 (This is a quick way to over-write 2nd phone info) |
109# |
Copy Telephone 1 Phone to Telephone 2 (This is a quick way to over-write 2nd phone info) |
110# |
to 159# Second Phone Number & Reporting (Not Used) |
160# |
Number of Rings before Answer |
I_10*#_I |
(1 to 15 Rings, 0 Disables) |
161# |
to 176# Download Number (Leave Blank)
I |
_ _ |
I |
_ _ |
I |
_ _ |
I |
_ _ |
I |
_ _ |
I |
_ _ |
I |
_ _ |
I |
_ _ |
I |
_ _ |
I |
_ _ |
I |
_ _ |
I |
_ _ |
I |
_ _ |
I |
_ _ |
I |
_ _ |
I |
_ _ |
I |
|
161 |
|
162 |
|
163 |
|
164 |
|
165 |
|
166 |
|
167 |
|
168 |
|
169 |
|
170 |
|
171 |
|
172 |
|
173 |
|
174 |
|
175 |
|
176 |
|
|
177# |
Two Digit Arming |
I_0*#_I |
(1 = Yes, 0 = No) |
178# |
Enable Force Arming |
I_0*#_I |
(1 = Yes, 0 = No) |
179# |
Permanent Force Arming |
I_0*#_I |
(1 = Yes, 0 = No) |
180# |
Delay Burg Restorals Until Cutoff |
I_0*#_I |
(1 = Yes, 0 = No) |
181# |
Alarm Reports Until Lockout |
I_3*#_I |
(1 to 15 Alarms before Lockout) |
182# |
Pulsing Burg Siren Output |
I_0*#_I |
(1 = Yes, 0 = No) |
183# |
Pulsing Fire Output |
I_0*#_I |
(1 = Yes, 0 = No) |
184# |
Burg Loop Audible Lockout |
I_0*#_I |
(1 = Yes, 0 = No) |
185# |
Keyswitch Mode Change |
I_0*#_I |
(1 = Yes, 0 = No) |
186# |
Supervisory/Day Alert Latch |
I_0*#_I |
(1 = Yes, 0 = No) |
187# |
Automatic Interior Off |
I_0*#_I |
(1 = Motion in Home/Away Mode, 0 = No) |
188# |
Extend BA Loop Stabilization |
I_0*#_I |
(1 = Yes, 0 = No) |
189# |
Disable Interior Follower |
I_0*#_I |
(1 = Yes, 0 = No) |
190# |
Interior On/Off if Armed |
I_0*#_I |
(1 = Bypass (4) key active if armed, 0 = No) |
191# |
Delay Off When Interior Off |
I_0*#_I |
(1 = Yes, 0 = No) |
192# |
Siren Test on Arming |
I_0*#_I |
(1 = Yes, 0 = No) |
193# |
Reset Test Timer on Kissoff |
I_0*#_I |
(1 = Yes, 0 = No) |
194# |
Interior Default Upon Disarm |
I_0*#_I |
(1 = Yes, 0 = No) > |
195# |
Disable Keypad Bypassing |
I_0*#_I |
(1 = Yes, 0 = No) |
196# |
Disable Key 4 Interior Bypass |
I_0*#_I |
(1 = Yes, 0 = No) |
197# |
Disable Key 6 Chime |
I_0*#_I |
(1 = Yes, 0 = No) |
198# |
Disable Key 7 Reset |
I_0*#_I |
(1 = Yes, 0 = No) |
199# |
Disable Key 8 Walk Test |
I_0*#_I |
(1 = Yes, 0 = No) |
200# |
Silent Keypad on Burg |
I_0*#_I |
(1 = Yes, 0 = No) |
201# |
Silent Keypad for Police Panic |
I_0*#_I |
(1 = Yes, 0 = No) |
202# |
Start Entry Delay on KP Entries |
I_0*#_I |
(1 = Yes, 0 = No) > |
203# |
Zone 1 Trouble on Open or Short |
I_0*#_I |
(1 = Yes, 0 = No) |
204# |
Zone 2 Trouble on Open or Short |
I_0*#_I |
(1 = Yes, 0 = No) |
205# |
Zone 3 Trouble on Open or Short |
I_0*#_I |
(1 = Yes, 0 = No) |
206# |
Zone 4 Trouble on Open or Short |
I_0*#_I |
(1 = Yes, 0 = No) |
207# |
Zone 5 Trouble on Open or Short |
I_0*#_I |
(1 = Yes, 0 = No) |
208# |
Zone 6 Trouble on Open or Short |
I_0*#_I |
(1 = Yes, 0 = No) > |
209# |
Extended Reporting User 1 |
I_0*#_I |
210# |
Extended Reporting User 2 |
I_0*#_I |
211# |
Extended Reporting User 3 |
I_0*#_I |
212# |
Extended Reporting User 4 |
I_0*#_I |
213# |
Extended Reporting User 5 |
I_0*#_I |
214# |
Extended Reporting User 6 |
I_2*#_I |
(2nd Digit of Hostage Code) |
215# |
Extended Keyswitch Report Code |
I_0*#_I > |
216# |
Zone 1 2nd Digit Alarm Report Code |
I_1*#_I |
(first digit is at 068, sends 31) |
217# |
Zone 2 2nd Digit Alarm Report Code |
I_2*#_I |
(first digit is at 069, sends 32) |
218# |
Zone 3 2nd Digit Alarm Report Code |
I_3*#_I |
(first digit is at 070, sends 33) |
219# |
Zone 4 2nd Digit Alarm Report Code |
I_4*#_I |
(first digit is at 071, sends 34) |
220# |
Zone 5 2nd Digit Alarm Report Code |
I_5*#_I |
(first digit is at 072, sends 35) |
221# |
Zone 6 2nd Digit Alarm Report Code |
I_6*#_I |
(first digit is at 073, sends 36) > |
222# |
Zone 1 2nd Digit Restore Report |
I_0*#_I |
(first digit is at 082) |
223# |
Zone 2 2nd Digit Restore Report |
I_0*#_I |
224# |
Zone 3 2nd Digit Restore Report |
I_0*#_I |
225# |
Zone 4 2nd Digit Restore Report |
I_0*#_I |
226# |
Zone 5 2nd Digit Restore Report |
I_0*#_I |
227# |
Zone 6 2nd Digit Restore Report |
I_0*#_I > |
228# |
Zone 1 2nd Digit Bypass Report |
I_0*#_I |
(Program these as 0) |
229# |
Zone 2 2nd Digit Bypass Report |
I_0*#_I |
230# |
Zone 3 2nd Digit Bypass Report |
I_0*#_I |
231# |
Zone 4 2nd Digit Bypass Report |
I_0*#_I |
232# |
Zone 5 2nd Digit Bypass Report |
I_0*#_I |
233# |
Zone 6 2nd Digit Bypass Report |
I_0*#_I > |
234# |
Zone 1 Supervisory Report Code |
I_0*#_I |
(first digit is at 083) |
235# |
Zone 2 Supervisory Report Code |
I_0*#_I |
236# |
Zone 3 Supervisory Report Code |
I_0*#_I |
237# |
Zone 4 Supervisory Report Code |
I_0*#_I |
238# |
Zone 5 Supervisory Report Code |
I_0*#_I |
239# |
Zone 6 Supervisory Report Code |
I_0*#_I |
(Use 6 if Smoke Detector on Zone 6) > |
240# |
Extended AC Report Code |
I_9*#_I |
(first digit is at 086, sends 79) |
241# |
Extended Battery Report Code |
I_0*#_I |
(first digit is at 084) |
242# |
Extended Memory Error Report Code |
I_0*#_I |
(first digit is at 088) |
243# |
Entended Test Code |
I_0*#_I |
(first digit is at 089) > |
244# |
Extended KP Fire Panic Code |
I_3*#_I |
(first digit is at 074, sends 23) |
|
(If Z700 this is 2nd digit of whatever panic you program it as (see section 261)) |
245# |
Extended KP Police Panic Code |
I_1*#_I |
(first digit is at 075, sends 21) |
246# |
Extended KP Medical Panic Code |
I_6*#_I |
(first digit is at 076, sends 26) |
247# |
Extended Missing KP Report Code |
I_0*#_I > |
248# |
Eliminate Burg EOL Resistors |
I_0*#_I |
(1 = No EOL Resistors, 0 = EOL Resistors) > |
249# |
Exits to Programming Entry Mode |
250# |
Default Master Code (No Value Required, Keypad beeps) > |
251# |
Fast Loop Response Time |
I_2*#_I |
(80ms) |
252# |
Slow Loop Response Time |
I_6*#_I |
(320ms) |
|
0 |
= 40 ms |
1 |
= 40 ms |
2 |
= 80 ms |
3 |
= 120 ms |
4 |
= 160 ms |
5 |
= 200 ms |
6 |
= 320 ms |
7 |
= 480 ms |
8 |
= 600ms |
9 |
= 800 ms |
10 |
= 1 sec |
11 |
= 2 sec |
12 |
= 4 sec |
13 |
= 6 sec |
14 |
= 8 sec |
15 |
= 10 sec |
|
253# |
Exits to Programming Entry Mode |
254# |
Default Panel to Factory |
I_0*#_I |
(0 = Normal, 1 = Defaults)
(Enter 1 + * + * will default and exit programming) >
|
255# |
Installer Code |
I_9_I_6_I_3_I_2_I_1_I
(Enter as 96321, not as 9*#, 8*# etc) >
|
256# |
Assignable Output Definition |
I_1_I |
(+12 Volt Output Terminal 3)
0 = Alarm Condition by Panic Keys
1 = Switched Power Reset using 7 Key (Smoke Reset)
2 = Activation of Access Output
3 = Supervisory/Trouble Conditions
4 = Entrance Pre-Alarms and Chime >
|
257# |
Burg Activates Assignable Output |
I_1*#_I |
(1 = + 12 Volts Activation, 0 = No) |
258# |
Aux A (Fire) Activates Output |
I_1*#_I |
(1 = + 12 Volts Activation, 0 = No) |
259# |
Aux B (Police) Activates Output |
I_1*#_I |
(1 = + 12 Volts Activation, 0 = No) |
260# |
Aux C (Medical) Activates Output |
I_1*#_I |
(1 = + 12 Volts Activation, 0 = No) > |
261# |
Disable Keypad Fire Panic |
I_0*#_I |
(1 = Yes, 0 = No) |
|
(If Z700 program 0 here to disable Panic or 1 = Burg Alarm, 2 = Fire, 3 = Police, 4 = Medical)
|
262# |
Disable Keypad Police Panic |
I_0*#_I |
(1 = Yes, 0 = No) |
263# |
Disable Keypad Medical Panic |
I_0*#_I |
(1 = Yes, 0 = No) > |
264# |
Reseved for Future |
Use (Do not Program) |
265# |
Tone Test Generation |
(Factory Use Only) |
266# |
Factory ID |
(Factory Use Only) > |
267# |
Telephone 1 Download Complete |
I_0*#_I |
(Report Disabled) |
268# |
Telephone 2 Download Complete |
I_0*#_I |
(Report Disabled) |
269# |
Extended Download Complete |
I_0*#_I |
(Report Disabled) |
270# |
Pulse Dialing 66/33 Make/Break Ratio |
I_0*#_I |
(Leave Alone) |
271# |
KP Panic 3 sec Hold or Press Twice |
I_1*#_I |
(0 = Press Twice, 1 = 3 Second Hold) |