Moose Z1100E Program

Click HERE for Binary Programming
Move to
Location
3 digits + #,   * = Saves Data # Moves to next Location
Enter Program (Locations 034 to 410)
1. Press Program Button on main panel
2. At keypad press 9 + Program Code (9 8 7 6 5)
or
1. Power down with black switch on bottom left of panel
2. Power up while holding Program Button on main panel
Move to
Location
Enter location + #
Enter Data Enter 1 to 3 digits in location + * to save + # to move to next location
Exit Program Press *

1# Master Code I_2_I_4_I_5_I_ _I_ _I 1. Enter location 001 to 008 then #
2# User 2 Code I_ _I_ _I_ _I_ _I_ _I 2. Enter 1 to 5 digit code without * or #                        
3# User 3 Code I_ _I_ _I_ _I_ _I_ _I 3. System will give long tone and exit
4# User 4 Code I_ _I_ _I_ _I_ _I_ _I
5# User 5 Code I_ _I_ _I_ _I_ _I_ _I
6# User 6 Code I_ _I_ _I_ _I_ _I_ _I
7# User 7 Code I_ _I_ _I_ _I_ _I_ _I
8# User 8 Code I_ _I_ _I_ _I_ _I_ _I
9# User 9 Code I_ _I_ _I_ _I_ _I_ _I
10# User 10 Code I_ _I_ _I_ _I_ _I_ _I
11# User 11 Code I_ _I_ _I_ _I_ _I_ _I
12# User 12 Code I_ _I_ _I_ _I_ _I_ _I
13# User 13 Code I_ _I_ _I_ _I_ _I_ _I
14# User 14 Code I_ _I_ _I_ _I_ _I_ _I
15# User 15 Code I_ _I_ _I_ _I_ _I_ _I
16# User 16 Code I_ _I_ _I_ _I_ _I_ _I
17# User 17 Code I_ _I_ _I_ _I_ _I_ _I (Usually Hostage Code)
18# User Program Authorization Code I_9_I_8_I_7_I_6_I_5_I (Master User Program Code)
19# Usage Count Code 6 I_255_I

20# Time Until Next Com Test I_0_I

21# Clear Alarm Memory (No Value Required)

22# Delete User Codes 01 to 17 (Example: 22 #+ 15 will delete User Code 15)

23# Entry 1 Time I_30_I (1 to 255 Seconds)
24# Entry 2 Time I_45_I (1 to 255 Seconds)
25# Exit Time I_61_I (1 to 255 Seconds)
(Even Times give Exit Beeps, Odd Times do not)

26# Access Time I_5_I (1 to 255 Seconds)
27# Delay Burg Output I_0_I (1 to 255 Seconds)
28# Burg Cutoff Time I_6_I (0 to 255 Minutes, 255 = No Timeout)

29# Fire Panic Cutoff Time I_255_I (0 to 255 Minutes, 255 = No Timeout)
30# Police Panic Cutoff Time I_6_I (0 to 255 Minutes, 255 = No Timeout)
31# Medical Panic Cutoff Time I_6_I (0 to 255 Minutes, 255 = No Timeout)

32# Time between Communicator Test I_7_I

33# Begin Upload Data (No Value Required, enables Download)

34# Configuration User Code 1 I_3*#_I (3 = Normal User Code)
35# Configuration User Code 2 I_3*#_I
36# Configuration User Code 3 I_3*#_I
37# Configuration User Code 4 I_3*#_I
38# Configuration User Code 5 I_3*#_I
39# Configuration User Code 6 I_3*#_I
40# Configuration User Code 7 I_3*#_I
41# Configuration User Code 8 I_3*#_I
42# Configuration User Code 9 I_3*#_I
43# Configuration User Code 10 I_3*#_I
44# Configuration User Code 11 I_3*#_I
45# Configuration User Code 12 I_3*#_I
46# Configuration User Code 13 I_3*#_I
47# Configuration User Code 14 I_3*#_I
48# Configuration User Code 15 I_3*#_I
49# Configuration User Code 16 I_3*#_I
50# Configuration User Code 17 I_9*#_I (9 = Hostage Code)

Lights may begin flashing at end of this section, press 51 # to continue

51# Zone 1 Configuration I_64*#_I Common Zone Configurations
52# Zone 2 Configuration I_72*#_I 64 = Delay
53# Zone 3 Configuration I_81*#_I 65 = Instant
54# Zone 4 Configuration I_65*#_I 66 = Fire
55# Zone 5 Configuration I_65*#_I 72 = Delay #2
56# Zone 6 Configuration I_65*#_I 81 = Interior Motion
57# Zone 7 Configuration I_65*#_I 02 = Medical Panic
58# Zone 8 Configuration I_65*#_I 03 = Audible Panic (Section 276 = 0)
03 = Silent Panic (Section 276 = 1)

(Zones 9 to 16 only used if Z234 Zone Expander is enabled (mounted on top of Main Panel)
59# Zone 9 Configuration I_65*#_I Common Zone Configurations
60# Zone 10 Configuration I_65*#_I 64 = Delay
61# Zone 11 Configuration I_65*#_I 65 = Instant
62# Zone 12 Configuration I_65*#_I 66 = Fire
63# Zone 13 Configuration I_65*#_I 72 = Delay #2
64# Zone 14 Configuration I_65*#_I 81 = Interior Motion
65# Zone 15 Configuration I_65*#_I 02 = Medical Panic
66# Zone 16 Configuration I_65*#_I 03 = Audible Panic (Section 276 = 0)
03 = Silent Panic (Section 276 = 1)

67# Communicator Delay/Enable I_1*#_I (1 to 255 Seconds, 0 = Disabled)
68# Dial Attempts Phone 1 I_8*#_I (1 to 15 Attempts)
69# Dial Attempts Phone 2 I_0*#_I (1 to 15 Attempts)

70# For Future Use I_#_I (Press # to Bypass)
71# For Future Use I_#_I (Press # to Bypass)

72# Communicator On-Hook Time I_3*#_I (1 to 255 Seconds)
73# Time between Dial Attempts (Sec) I_10*#_I (1 to 255 Seconds)
74# Abort Communicator on Disarming I_0*#_I (0 = No, 1 = Yes)
75# Disable Dialer Test on Power-Up I_0*#_I (0 = No, 1 = Yes)
76# Exception Open/Close Restore I_0*#_I (0 = No, 1 = Yes)

77# 1st Digit of Account Number I_?*#_I (Program 10 if 0 is in Account)
78# 2nd Digit of Account Number I_?*#_I (A = 10 B = 11 C = 12)
79# 3rd Digit of Account Number I_?*#_I (D = 13 E = 14 F = 15)
80# 4th Digit of Account Number I_?*#_I

81# Transmission Format I_2*#_I
0 = Autobaud (Auto selects handshake from Receiver)
1 = 1400 Hz Handshake, 1900 Hz Data 10 Baud (Osborne, Radionics, Silent Knight)
2 = 2300 Hz Handshake, 1800 Hz Data 20 Baud (DCI, FBII, Franklin, Sescoa)
3 = 1400 or 2300 Hz Handshake, 1800 Hz Data 40 Baud (Radionics Superfast)
4 = 1400 Hz Handshake, 1900 Hz Data, 15 Baud (Silent Knight Fast Format)
5 = 1400 Hz or 2300 Hz Handshake (Radionics BFSK)
6 = Sescoa Model 3000 Slow Format
7 = Sescoa Model 3000 Fast Format

82# Single Round Format I_0*#_I (0 = No, 1 = Yes)
83# 4/2 Format Enable I_1*#_I (0 = No, 1 = Yes)
84# Extended Standard I_0*#_I (0 = No, 1 = Yes)
85# Extended Single Line I_0*#_I (0 = No, 1 = Yes)
86# Parity Checksum I_0*#_I (0 = No, 1 = Yes)
87# Touchtone Dialing I_1*#_I (0 = No, 1 = Yes)

88# Zone 1 1st Digit Report Code I_3*#_I (Sends 31, 2nd digit is in 312)
89# Zone 2 1st Digit Report Code I_3*#_I (Sends 32, 2nd digit is in 313)
90# Zone 3 1st Digit Report Code I_3*#_I (Sends 33, 2nd digit is in 314)
91# Zone 4 1st Digit Report Code I_3*#_I (Sends 34, 2nd digit is in 315)
92# Zone 5 1st Digit Report Code I_3*#_I (Sends 35, 2nd digit is in 316)
93# Zone 6 1st Digit Report Code I_3*#_I (Sends 36, 2nd digit is in 317)
94# Zone 7 1st Digit Report Code I_3*#_I (Sends 37, 2nd digit is in 318)
95# Zone 8 1st Digit Report Code I_3*#_I (Sends 38, 2nd digit is in 319)
96# Zone 9 1st Digit Report Code I_3*#_I (Sends 39, 2nd digit is in 320)
97# Zone 10 1st Digit Report Code I_4*#_I (Sends 41, 2nd digit is in 321)
98# Zone 11 1st Digit Report Code I_4*#_I (Sends 42, 2nd digit is in 322)
99# Zone 12 1st Digit Report Code I_4*#_I (Sends 43, 2nd digit is in 323)
100# Zone 13 1st Digit Report Code I_4*#_I (Sends 44, 2nd digit is in 324)
101# Zone 14 1st Digit Report Code I_4*#_I (Sends 45, 2nd digit is in 325)
102# Zone 15 1st Digit Report Code I_4*#_I (Sends 46, 2nd digit is in 326)
103# Zone 16 1st Digit Report Code I_4*#_I (Sends 47, 2nd digit is in 327)

104# Keypad Fire 1st Digit Report Code I_2*#_I (Sends 23, 2nd digit is in 380)
105# Keypad Police 1st Digit Report Code I_2*#_I (Sends 21, 2nd digit is in 381)
106# Keypad Medical 1st Digit Report Code I_2*#_I (Sends 26, 2nd digit is in 382)
107# Duress 1st Digit Report Code I_2*#_I (Sends 22, 2nd digit is in 310)

108# Open 1st Digit Report Code I_0*#_I (Disabled, 2nd digit is in 294 to 310)
109# Close 1st Digit Report Code I_0*#_I (Disabled, 2nd digit is in 294 to 310)
110# Bypass 1st Digit Report Code I_0*#_I (Disabled, 2nd digit is in 344 to 359)
111# Cancel 1st Digit Report Code I_0*#_I (Do not use, wierd way of sending)
112# Zone Restore 1st Digit Report Code I_0*#_I (Disabled, 2nd digit is in 328 to 343)
113# Supervisory 1st Digit Report Code I_7*#_I (Sends 76, 2nd digit is in 360 to 375)
114# Low Bat 1st Digit Report Code I_7*#_I (Sends 78, 2nd digit is in 377)
115# Bat Restore 1st Digit Report Code I_0*#_I (Disabled, 2nd digit is in 377)
116# AC Fail 1st Digit Report Code I_7*#_I (Sends 79, 2nd digit is in 376)
117# AC Restore 1st Digit Report Code I_0*#_I (Disabled, 2nd digit is in 376)
118# Memory Error Report Code I_0*#_I (Disabled, 2nd digit is in 378)
119# Auto Test Report Code I_14*#_I (Disabled, 2nd digit is in 379)

120# Telephone 1 Digit 1 I_1*#_I 11 = *
121# Telephone 1 Digit 2 I_8*#_I 12 = #
122# Telephone 1 Digit 3 I_ _I 13 = 3 Second Pause
123# Telephone 1 Digit 4 I_ _I 14 = Wait for Dial Tone
124# Telephone 1 Digit 5 I_ _I 15 = End Phone Number
125# Telephone 1 Digit 6 I_ _I
126# Telephone 1 Digit 7 I_ _I Use 0 for 0 in Phone Number
127# Telephone 1 Digit 8 I_ _I
128# Telephone 1 Digit 9 I_ _I
129# Telephone 1 Digit 10 I_ _I
130# Telephone 1 Digit 11 I_ _I
131# Telephone 1 Digit 12 I_15*#_I
132# Telephone 1 Digit 13 I_15*#_I
133# Telephone 1 Digit 14 I_15*#_I
134# Telephone 1 Digit 15 I_15*#_I
135# Telephone 1 Digit 16 I_15*#_I
136# Telephone 1 Digit 17 I_15*#_I
137# Telephone 1 Digit 18 I_15*#_I
138# Telephone 1 Digit 19 I_15*#_I
139# Telephone 1 Digit 20 I_15*#_I
140# Telephone 1 Digit 21 I_15*#_I
141# Telephone 1 Digit 22 I_15*#_I
142# Telephone 1 Digit 23 I_15*#_I
143# Telephone 1 Digit 24 I_15*#_I
144# Telephone 1 Digit 25 I_15*#_I
145# Telephone 1 Digit 26 I_15*#_I

146# Audio Listen-In Telephone 1 I_0*#_I (0 = No, 1 = Yes)

147# Exits to Program Entry Mode (No Value Required)
(Keypad Lights may flash, enter next location then #)

148# Copy Telephone 1 Info to Telephone 2 (No Value Required)
149# Copy Telephone Phone Number 1 to 2 (No Value Required)
(Press 148# and 149# as quck way to get rid of programming in Phone 2)

150# to 219# Second Phone & Reporting Do Not Program

220# Rings before Panel Answers I_12*#_I

221# to 246# Download Telephone Number Leave Blank

247# Z234 Eight Zone Expander Enable I_0*#_I (0 = No, 1 = Yes)

248# Two Digit Arming I_0*#_I (0 = No, 1 = Yes)
249# Enable Force Arming I_0*#_I (0 = No, 1 = Yes)
250# Permanent Force Arming I_0*#_I (0 = No, 1 = Yes)

251# Delay Burg Rest Until Cutoff I_0*#_I (0 = No, 1 = Yes)
252# Swinger Shutdown I_3*#_I (1 to 15 alarms)
253# Pulsing Burg Siren Output I_0*#_I (0 = No, 1 = Yes)
254# Pulsing Fire Output I_0*#_I (0 = No, 1 = Yes)
255# Burg Loop Audible Lockout I_0*#_I (0 = No, 1 = Yes)
256# Keyswitch Mode Change I_0*#_I (0 = No, 1 = Yes)
257# Supervisory/Day Alert Latch I_0*#_I (0 = No, 1 = Yes)
258# Automatic Interior/Motions Off I_0*#_I (0 = No, 1 = Home Away)
259# Entry Delay Off If Interior Off I_0*#_I (0 = No, 1 = Yes)
260# Extend BA Loop Stabilization I_0*#_I (0 = No, 1 = Yes)
261# Siren Test on Arming I_0*#_I (0 = No, 1 = Yes)
262# Slave Mode Operation I_0*#_I (0 = No, 1 = Yes)
263# Reset Test Timer on Kissoff I_0*#_I (0 = No, 1 = Yes)
264# Interior Default on Disarm I_0*#_I (0 = No, 1 = Motions back to Normal)

265# Comand Keys 4 and 5 work if Armed I_0*#_I (0 = No, 1 = Yes)
(Bypassing of Motions and Instant Doors even if System is Armed)

266# Disable Fire Panic Key I_0*#_I (0 = No, 1 = Yes)
267# Disable Police Panic Key I_0*#_I (0 = No, 1 = Yes)
268# Disable Medical Panic Key I_0*#_I (0 = No, 1 = Yes)
269# Diable Keypad Bypassing I_0*#_I (0 = No, 1 = Yes)
270# Diable Key 4 Interior Function I_0*#_I (0 = No, 1 = Yes)
271# Disable Key 5 Instant Function I_0*#_I (0 = No, 1 = Yes)
272# Disable Key 6 Chime Function I_0*#_I (0 = No, 1 = Yes)
273# Disable Key 7 Reset Function I_0*#_I (0 = No, 1 = Yes)
274# Disable Key 8 Walk Test Function I_0*#_I (0 = No, 1 = Yes)

275# Silent Keypad on Burg Alarm I_0*#_I (0 = No, 1 = Yes)
276# Silent Alarm/No Keypad LED Police Panic I_0*#_I (0 = No, 1 = Yes if Commercial)
277# Start Entry Delay on KP Entries I_0*#_I (0 = No, 1 = Yes)

278# Zone 1 Supervisory Type I_0*#_I (0 = Open, 1 = Short)
279# Zone 2 Supervisory Type I_0*#_I (0 = Open, 1 = Short)
280# Zone 3 Supervisory Type I_0*#_I (0 = Open, 1 = Short)
281# Zone 4 Supervisory Type I_0*#_I (0 = Open, 1 = Short)
282# Zone 5 Supervisory Type I_0*#_I (0 = Open, 1 = Short)
283# Zone 6 Supervisory Type I_0*#_I (0 = Open, 1 = Short)
284# Zone 7 Supervisory Type I_0*#_I (0 = Open, 1 = Short)
285# Zone 8 Supervisory Type I_0*#_I (0 = Open, 1 = Short)
286# Zone 9 Supervisory Type I_0*#_I (0 = Open, 1 = Short)
287# Zone 10 Supervisory Type I_0*#_I (0 = Open, 1 = Short)
288# Zone 11 Supervisory Type I_0*#_I (0 = Open, 1 = Short)
289# Zone 12 Supervisory Type I_0*#_I (0 = Open, 1 = Short)
290# Zone 13 Supervisory Type I_0*#_I (0 = Open, 1 = Short)
291# Zone 14 Supervisory Type I_0*#_I (0 = Open, 1 = Short)
292# Zone 15 Supervisory Type I_0*#_I (0 = Open, 1 = Short)
293# Zone 16 Supervisory Type I_0*#_I (0 = Open, 1 = Short)

294# Extended Reporting User 1 I_0*#_I (1st digit is in 108, 109, 110)
295# Extended Reporting User 2 I_0*#_I
296# Extended Reporting User 3 I_0*#_I
297# Extended Reporting User 4 I_0*#_I
298# Extended Reporting User 5 I_0*#_I
299# Extended Reporting User 6 I_0*#_I
300# Extended Reporting User 7 I_0*#_I
301# Extended Reporting User 8 I_0*#_I
302# Extended Reporting User 9 I_0*#_I
303# Extended Reporting User 10 I_0*#_I
304# Extended Reporting User 11 I_0*#_I
305# Extended Reporting User 12 I_0*#_I
306# Extended Reporting User 13 I_0*#_I
307# Extended Reporting User 14 I_0*#_I
308# Extended Reporting User 15 I_0*#_I
309# Extended Reporting User 16 I_0*#_I
310# Extended Reporting User 17 I_2*#_I (Duress)(Sends 22, 1st digit is in 107)
311# Keyswitch Reporting I_0*#_I (Disabled)

312# Zone 1 2nd Digit Alarm Report Code I_1*#_I (Sends 31, 1st digit is in 088)
313# Zone 2 2nd Digit Alarm Report Code I_2*#_I (Sends 32, 1st digit is in 089)
314# Zone 3 2nd Digit Alarm Report Code I_3*#_I (Sends 33, 1st digit is in 090)
315# Zone 4 2nd Digit Alarm Report Code I_4*#_I (Sends 34, 1st digit is in 091)
316# Zone 5 2nd Digit Alarm Report Code I_5*#_I (Sends 35, 1st digit is in 092)
317# Zone 6 2nd Digit Alarm Report Code I_6*#_I (Sends 36, 1st digit is in 093)
318# Zone 7 2nd Digit Alarm Report Code I_7*#_I (Sends 37, 1st digit is in 094)
319# Zone 8 2nd Digit Alarm Report Code I_8*#_I (Sends 38, 1st digit is in 095)
(If using Smoke on Zones 16 enter 1 for a report code of 16, 2nd digit is in 319)
320# Zone 9 2nd Digit Alarm Report Code I_9*#_I (Sends 39, 1st digit is in 096)
321# Zone 10 2nd Digit Alarm Report Code I_1*#_I (Sends 41, 1st digit is in 097)
322# Zone 11 2nd Digit Alarm Report Code I_2*#_I (Sends 42, 1st digit is in 098)
323# Zone 12 2nd Digit Alarm Report Code I_3*#_I (Sends 43, 1st digit is in 099)
324# Zone 13 2nd Digit Alarm Report Code I_4*#_I (Sends 44, 1st digit is in 100)
325# Zone 14 2nd Digit Alarm Report Code I_5*#_I (Sends 45, 1st digit is in 101)
326# Zone 15 2nd Digit Alarm Report Code I_6*#_I (Sends 46, 1st digit is in 102)
327# Zone 16 2nd Digit Alarm Report Code I_7*#_I (Sends 47, 1st digit is in 103)
(If using Smoke on Zones 16 enter 1 for a report code of 16, 2nd digit is in 327)

328# Zone 1 2nd Digit Restore Report I_0*#_I (Disabled, 1st digit is in 112)
329# Zone 2 2nd Digit Restore Report I_0*#_I
330# Zone 3 2nd Digit Restore Report I_0*#_I
331# Zone 4 2nd Digit Restore Report I_0*#_I
332# Zone 5 2nd Digit Restore Report I_0*#_I
333# Zone 6 2nd Digit Restore Report I_0*#_I
334# Zone 7 2nd Digit Restore Report I_0*#_I
335# Zone 8 2nd Digit Restore Report I_0*#_I
336# Zone 9 2nd Digit Restore Report I_0*#_I
337# Zone 10 2nd Digit Restore Report I_0*#_I
338# Zone 11 2nd Digit Restore Report I_0*#_I
339# Zone 12 2nd Digit Restore Report I_0*#_I
340# Zone 13 2nd Digit Restore Report I_0*#_I
341# Zone 14 2nd Digit Restore Report I_0*#_I
342# Zone 15 2nd Digit Restore Report I_0*#_I
343# Zone 16 2nd Digit Restore Report I_0*#_I

344# Zone 1 2nd Digit Bypass Report I_0*#_I (1st digit is in 110)
345# Zone 2 2nd Digit Bypass Report I_0*#_I
346# Zone 3 2nd Digit Bypass Report I_0*#_I
347# Zone 4 2nd Digit Bypass Report I_0*#_I
348# Zone 5 2nd Digit Bypass Report I_0*#_I
349# Zone 6 2nd Digit Bypass Report I_0*#_I
350# Zone 7 2nd Digit Bypass Report I_0*#_I
351# Zone 8 2nd Digit Bypass Report I_0*#_I
352# Zone 9 2nd Digit Bypass Report I_0*#_I
353# Zone 10 2nd Digit Bypass Report I_0*#_I
354# Zone 11 2nd Digit Bypass Report I_0*#_I
355# Zone 12 2nd Digit Bypass Report I_0*#_I
356# Zone 13 2nd Digit Bypass Report I_0*#_I
357# Zone 14 2nd Digit Bypass Report I_0*#_I
358# Zone 15 2nd Digit Bypass Report I_0*#_I
359# Zone 16 2nd Digit Bypass Report I_0*#_I

360# Zone 1 Supervisory Report Code I_0*#_I (1st digit is in 113)
361# Zone 2 Supervisory Report Code I_0*#_I
362# Zone 3 Supervisory Report Code I_0*#_I
363# Zone 4 Supervisory Report Code I_0*#_I
364# Zone 5 Supervisory Report Code I_0*#_I
365# Zone 6 Supervisory Report Code I_0*#_I
366# Zone 7 Supervisory Report Code I_0*#_I
367# Zone 8 Supervisory Report Code I_0*#_I (If Smoke on Zone 8 enter 6)
368# Zone 9 Supervisory Report Code I_0*#_I
369# Zone 10 Supervisory Report Code I_0*#_I
370# Zone 11 Supervisory Report Code I_0*#_I
371# Zone 12 Supervisory Report Code I_0*#_I
372# Zone 13 Supervisory Report Code I_0*#_I
373# Zone 14 Supervisory Report Code I_0*#_I
374# Zone 15 Supervisory Report Code I_0*#_I
375# Zone 16 Supervisory Report Code I_0*#_I (If Smoke on Zone 16 enter 6)

376# Extended AC Report Code I_9*#_I (Sends 79, 1st digit is in 116)
377# Extended Battery Report Code I_8*#_I (Sends 78, 1st digit is in 114)
378# Extended Memory Error Report Code I_0*#_I (Disabled, 1st digit is in 118)
379# Entended Test Code I_10*#_I (Disabled, 1st digit is in 119)
380# Extended KP Fire Panic Code I_3*#_I (Sends 23, 1st digit is in 104)
381# Extended KP Police Panic Code I_1*#_I (Sends 21, 1st digit is in 105)
382# Extended KP Medical Panic Code I_6*#_I (Sends 26, 1st digit is in 106)
383# Extended Missing KP Report Code I_0*#_I (Disabled)

304# to 401# Exits to Program Mode

402# Fast Loop Response Time x40 ms I_2*#_I (0 to 255)
403# Slow Loop Response Time I_2*#_I (0 to 255)

404# Exits to Programming Entry Mode

405# Default Panel to Factory I_0*#_I (0 = Normal, 1 = Default Panel)

406# Lockout User 1 to 8 Programming I_0*#_I (0 to 255)
407# Lockout User 9 to 16 Programming I_0*#_I (0 to 255)
408# Lockout User 17 to 24 Programming I_0*#_I (0 to 255)
409# Lockout User 25 to 32 Programming I_0*#_I (0 to 255)

410# Installer Program Code I_9_I_8_I_7_I_6_I_5_I
(Enter 98765, not 9*#, 8*# etc)

Press * to Exit Programming