Moose Z1100E Basics
We cannot do downloads for any Moose panels! | |||||||
Zones | 8 Hardwire, 16 with Zone Expander | ||||||
Battery | 12 volt rechargeable Gel-Cell inside main panel | ||||||
AC Transformer | 18 Volt 35 AH | ||||||
Wireless | No | ||||||
Downloadable | No | ||||||
Panic Buttons |
|
||||||
Keypad has flip-up cover, open shows fuctions of keys, closed shows system status | |||||||
Arm | Press 1 + User Code (Ready To Arm light must be ON) | ||||||
Arm Stay |
1. 4 + User Code (Interior light turns OFF) 2. Arm system with 1 + User Code |
||||||
Instant Doors | 5 + User Code (Instant light turns ON) | ||||||
Disarm | 1 + User Code (Armed light turns OFF) | ||||||
Silence Alarm | 1 + User Code (Armed light turns OFF) | ||||||
Reset Alarm | Press * to stop flashing and wrong User Codes | ||||||
Check Zones |
2 + User Code (Open zones show for 8 seconds) (For 16 zone system press 2 again to show zones 9 to 16) |
||||||
Alarm Memory | 3 + User Code, (Last alarm will show) | ||||||
Bypass Zones | # + zone (01 to 16) (Ready to Arm starts flashing) | ||||||
Remove Bypass | # + 9 (Ready to Arm stops flashing | ||||||
Door Chimes | 6 + User Code (Motions may beep too) | ||||||
Reset Smoke |
7 + User Code + * (If this does NOT reset smoke set for service, smoke is bad) |
||||||
Sensor Test | 8 + User Code, open door/windows, keypad beeps, press * to end | ||||||
******LCD Keypad Commands******![]() Keypad has 3 main keys below display, each works with what word is displayed above |
|||||||
Arm | Press button below LEAVE + User Code (Display must show READY) | ||||||
Disarm | Press button below DISARM/OFF + User Code | ||||||
Arm Home | Press button below STAY + User Code | ||||||
Check Status |
1. Press MENU (blue triangle key) until display reads ZONE STATUS 2. Press key below ZONE STATUS display, system will show open zones |
||||||
Reset Display | Press * | ||||||
Alarm Memory |
1. Press MENU (blue triangle) until display shows ALARM HISTORY 2. Press key below ALARM HISTORY display to show previous alarms |
||||||
Zone Bypass |
1. Press MENU (blue triangle) until display shows BYPASS 2. Press key below BYPASS display and enter zones to bypass |
||||||
Remove Bypass | # + 9 | ||||||
Instant Doors |
1. Press MENU (blue triangle) until display shows DELAY 2. Press key below to toggle DELAY & INSTANT |
||||||
Door Chimes | 6 + User Code (Motions may beep too) | ||||||
Reset Smoke |
7 + User Code + * (If this does NOT reset smoke set for service, smoke is bad) |
||||||
Sensor Test | 8 + User Code, open door/window, keypad will beep, to exit press * | ||||||
Display Adjust |
|
||||||
Set Clock |
1. Press MENU (blue triangle) until display shows SET CLOCK 2. Use 3 keys below to move left/right within display + disired number keys 3. To change AM to PM move cursor under and press any key 4. Press * to exit |