Moose Z1100E Basics

We cannot do downloads for any Moose panels!
Zones 8 Hardwire, 16 with Zone Expander
Battery 12 volt rechargeable Gel-Cell inside main panel
AC Transformer 18 Volt 35 AH
Wireless No
Downloadable No
Panic Buttons
Fire Panic “A” 1 and 7
Police Panic “B” * and # or 1 and 3
Medical Panic “C” 3 and 9
Keypad has flip-up cover, open shows fuctions of keys, closed shows system status
Arm Press 1 + User Code (Ready To Arm light must be ON)
Arm Stay 1. 4 + User Code (Interior light turns OFF)
2. Arm system with 1 + User Code
Instant Doors 5 + User Code (Instant light turns ON)
Disarm 1 + User Code (Armed light turns OFF)
Silence Alarm 1 + User Code (Armed light turns OFF)
Reset Alarm Press * to stop flashing and wrong User Codes
Check Zones 2 + User Code (Open zones show for 8 seconds)
(For 16 zone system press 2 again to show zones 9 to 16)
Alarm Memory 3 + User Code, (Last alarm will show)
Bypass Zones # + zone (01 to 16) (Ready to Arm starts flashing)
Remove Bypass # + 9 (Ready to Arm stops flashing
Door Chimes 6 + User Code (Motions may beep too)
Reset Smoke 7 + User Code + *
(If this does NOT reset smoke set for service, smoke is bad)
Sensor Test 8 + User Code, open door/windows, keypad beeps, press * to end
******LCD Keypad Commands******

Keypad has 3 main keys below display, each works with what word is displayed above
Arm Press button below LEAVE + User Code (Display must show READY)
Disarm Press button below DISARM/OFF + User Code
Arm Home Press button below STAY + User Code
Check Status 1. Press MENU (blue triangle key) until display reads ZONE STATUS
2. Press key below ZONE STATUS display, system will show open zones
Reset Display Press *
Alarm Memory 1. Press MENU (blue triangle) until display shows ALARM HISTORY
2. Press key below ALARM HISTORY display to show previous alarms
Zone Bypass 1. Press MENU (blue triangle) until display shows BYPASS
2. Press key below BYPASS display and enter zones to bypass
Remove Bypass # + 9
Instant Doors 1. Press MENU (blue triangle) until display shows DELAY
2. Press key below to toggle DELAY & INSTANT
Door Chimes 6 + User Code (Motions may beep too)
Reset Smoke 7 + User Code + *
(If this does NOT reset smoke set for service, smoke is bad)
Sensor Test 8 + User Code, open door/window, keypad will beep, to exit press *
Display Adjust
1. Press MENU until display shows
VIEWING ANGLE, ADJUST LAMP, ADJUST BEEPS
2. Press key below function to program, * to exit
Set Clock 1. Press MENU (blue triangle) until display shows SET CLOCK
2. Use 3 keys below to move left/right within display + disired number keys
3. To change AM to PM move cursor under and press any key
4. Press * to exit