Step |
Description |
Value |
01 |
Enter MF Header |
(Just a description of system)
|
02 |
Enable Telephone Communication ( Y/N ) |
Y
|
03 |
Enter Phone 1 |
?????? |
|
Cntrl STA Format for Ph 1 |
Radi Hex (most common) |
|
Sescoa Standard |
(3×1 report, Account number from 000 to 999) |
Sescoa Super Speed |
(4×3 report, Account number from 0000 to 3374) |
Radionics Hex |
(3×1 report, Account number from 000 to FFE (A is not used) |
SEIA |
(Not supported by 1700 Dialer) |
|
|
Enter Account for Ph 1 3-digits |
(4 if using Sescoa Fast)
|
04 |
Enter Phone 2 |
Not Used |
|
Cntrl STA Format for Ph 2 |
Doesn’t Matter |
|
Enter Account for Ph 2 |
Doesn’t Matter
|
05 |
Enter Phone 3A |
Not Used
|
06 |
Enter Phone 3B |
Not Used |
|
Cntrl Sta Format for Ph 3 |
Doesn’t Matter |
|
Enter Account # for Ph 3 |
Doesn’t Matter
|
07 |
Use DTMF Dialing ( Y/N ) |
Y |
|
DTMF Fast Rate Dialing ( Y/N ) |
Y
|
08 |
Is Ground Start Required ( Y/N ) |
N
|
09 |
Enter Number of Call Tries |
10
|
10 |
Enter Sleep Cycles ( 0 – 14 ) |
2
|
11 |
Enter Sleep Time ( Min ) |
4
|
12 |
Enter Anti-Jam Time ( 15 – 255 ) |
30
|
13 |
Enter Loop Restoral Code |
Not Used
|
14 |
Supervisory Reports? ( Y/N ) |
Y
|
15 |
Enter Primary Superv Phone 1 |
1
|
16 |
Enter Secondary Superv Phone |
4
|
17 |
Report To Both Number? ( Y/N ) |
N
|
18 |
Open or Close Reports? ( Y/N ) |
N
|
19 |
Open Signal Polarity + ? ( Y/N ) |
Y
|
20 |
Enter Open (Disarm) Code |
0
|
21 |
Enter Close (Arm) Code |
0
|
22 |
Send Test Code? ( Y/N ) |
N
|
23 |
Enter Test/Cancel Code |
0
|
24 |
Are Battery Rpts Required? ( Y/N ) |
N
|
25 |
Enter Low Battery Code |
0
|
26 |
Enter Battery Restoral? ( Y/N ) |
Y
|
27 |
Enter Battery Restoral Code |
0
|
28 |
Enter Battery Detect Time |
Doesn’t Matter
|
29 |
Is 24Hr Check-In Required? ( Y/N ) |
N
|
30 |
Enter Check-In Code |
0
|
31 |
Enter Loop 1-8 Select |
1 |
|
LO1 – Active Loop? ( Y/N ) |
Y |
|
LO1 – Trigger Polarity +? ( Y/N ) |
Y |
|
LO1 – Eliminate Swingers? ( Y/N ) |
Y |
|
LO1 – Enter E.S. Count ( 1-8 ) |
3 |
|
LO1 – Primary Phone #? ( 1-3 ) |
1 |
|
LO1 – Secondary Phone #? ( 1-3 ) |
4 |
|
LO1 – Report To Both #’s? ( Y/N ) |
N |
|
LO1 – Report Loop Restoral? ( Y/N ) |
N |
|
LO1 – Enter Alarm Code ( 0 – 99 ) |
01 |
|
LO1 – Enter Loop Response |
0 |
|
LO1 – Enter Loop Priority ( 1-7H ) |
7 |
|
LO1 – Audio Loop? ( Y/N ) |
Y if using 2-way |
|
LO1 – Audio Listen Only? ( Y/N ) |
N
|
|
LO2 – Active Loop? ( Y/N ) |
Y |
|
LO2 – Trigger Polarity +? ( Y/N ) |
Y |
|
LO2 – Eliminate Swingers? ( Y/N ) |
Y |
|
LO2 – Enter E.S. Count ( 1-8 ) |
3 |
|
LO2 – Primary Phone #? ( 1-3 ) |
1 |
|
LO2 – Secondary Phone #? ( 1-3 ) |
4 (Why? I don’t know) |
|
LO2 – Report To Both #’s? ( Y/N ) |
N |
|
LO2 – Report Loop Restoral? ( Y/N ) |
N |
|
LO2 – Enter Alarm Code ( 0 – 99 ) |
02 |
|
LO2 – Enter Loop Response |
0 |
|
LO2 – Enter Loop Priority ( 1-7H ) |
6 |
|
LO2 – Audio Loop? ( Y/N ) |
Y if using 2-way |
|
LO2 – Audio Listen Only? ( Y/N ) |
N
|
|
LO3 – Active Loop? ( Y/N ) |
Y |
|
LO3 – Trigger Polarity +? ( Y/N ) |
Y |
|
LO3 – Eliminate Swingers? ( Y/N ) |
Y |
|
LO3 – Enter E.S. Count ( 1-8 ) |
3 |
|
LO3 – Primary Phone #? ( 1-3 ) |
1 |
|
LO3 – Secondary Phone #? ( 1-3 ) |
4 (Why? I don’t know) |
|
LO3 – Report To Both #’s? ( Y/N ) |
N |
|
LO3 – Report Loop Restoral? ( Y/N ) |
N |
|
LO3 – Enter Alarm Code ( 0 – 99 ) |
03 |
|
LO3 – Enter Loop Response |
0 |
|
LO3 – Enter Loop Priority ( 1-7H ) |
5 |
|
LO3 – Audio Loop? ( Y/N ) |
Y if using 2-way |
|
LO3 – Audio Listen Only? ( Y/N ) |
N
|
|
LO4 – Active Loop? ( Y/N ) |
N |
|
LO5 – Active Loop? ( Y/N ) |
N |
|
LO6 – Active Loop? ( Y/N ) |
N |
|
LO7 – Active Loop? ( Y/N ) |
N |
|
LO8 – Active Loop? ( Y/N ) |
N
|
32 |
RCM Direction ( Y/N )
(Remote Control Module)
|
N
|
33 |
Enable Remote Access? ( Y/N ) |
Y
|
34 |
Lock Communicator? ( Y/N ) |
N |