Linear Dual 824 Program

Formats Contact ID or 4/2 (Contact ID preferred)
Enter Program 1. Enter Master Code + TEST (1 Gong + 5 Beeps)
2. Enter Master Code Again + TEST (1 Gong + 5 Beeps, all active zones light)
Exit Program Press OFF for 3 seconds
Program Location Location + HOME + Enter new Value + AWAY (should hear 1 bing)
(To program 30 second Entry Delay press 25 + HOME + 30 + AWAY)
Delete Location Location + HOME + AWAY (should hear 1 bing)
Compatible
Wireless
DXS-10 Wireless Keypad DXS-81 Bill Trap
DXS-31 Door/Window DXS-91 Glass Break
DXS-54 Motion Detector DXT-21 & DXT-23 Remotes
DXS-71 Smoke Detector DXT-41 & DXT-42 2 Keyfobs
DXS-72 Smoke Detector DXT-61 Remote Panic
Add Sensor Enter sensor number (01 to 24), zone light will flash, activate sensor
(1 “Bing” = Program OK, 2 “Bings” = sensor already programmed in location)
(If learning DX-10 keypad press and hold * and do not program a zone type)
Supervisory
Zone Number + HOME + (16 to 19) + AWAY
Non-Supervised 16 (Panic Buttons/Remote Keypads)
Supervised 17 (Doors, Smokes, Motions etc)
Manual Restoring 18
Auto Restoring 19
By default any wireless sensor added to system is supervised
Delete Sensor 1. Enter sensor to remove (01 to 24), zone light will flash
2. Press TEST, 1 “Bing” will sound and zone light will turn off
Defaulting Panel
(V1.7 and above)
(V1.6 and below) Hold * + TEST while powering up
In programming press 999 + TEST + 999 + TEST wait 10 seconds
Note: After defaulting press * + New 4 to 5 Digit Master Code + OFF

Loc Description Possible Entries
01 Zone 01 Type I_ _I 1 = Home Automation
2 = Emergency
3 = Panic
4 = Fire
5 = Perimeter
6 = Entry/Exit
7 = Interior Motion
8 = Chime (No Alarm)
9 = 2 – Button Arm/Disarm
(Home Automation)
10 = 2 -Button Arm/Disarm
(Use for Keyfob)
11 = Environmental
(Siren only, no Report)
02 Zone 02 Type I_ _I
03 Zone 03 Type I_ _I
04 Zone 04 Type I_ _I
05 Zone 05 Type I_ _I
06 Zone 06 Type I_ _I
07 Zone 07 Type I_ _I
08 Zone 08 Type I_ _I
09 Zone 09 Type I_ _I
10 Zone 10 Type I_ _I
11 Zone 11 Type I_ _I
12 Zone 12 Type I_ _I
13 Zone 13 Type I_ _I
14 Zone 14 Type I_ _I
15 Zone 15 Type I_ _I
16 Zone 16 Type I_ _I
17 Zone 17 Type I_ _I
18 Zone 18 Type I_ _I
19 Zone 19 Type I_ _I
20 Zone 20 Type I_ _I
21 Zone 21 Type I_ _I
22 Zone 22 Type I_ _I
23 Zone 23 Type I_ _I
24 Zone 24 Type I_ _I
25 Entry Delay I_30_I 20 to 255 seconds
26 Exit Delay I_60_I 20 to 255 seconds
30 Burg Siren Time I_5_I 1 to 30 minutes
31 Emergency Siren Time I_5_I 1 to 30 minutes
32 Fire Siren Time I_5_I 1 to 30 minutes
40 Automation Output Time I_5_I 0 to 2500 Seconds
0 = Toggle On/Off
50 Keyfob Arming Mode I_3_I 2 = Home Mode
3 = Away Mode
51 Keyfob Disarming Mode I_0_I 0 = OFF Mode
1=Chime Mode
61 Entry Delay Beeps I_1_I 0 = OFF
1 = ON
62 Exit Delay Beeps I_1_I 0 = OFF
1 = ON
63 Burglary Alarm I_0_I 0 = Audible
1 = Silent
64 Emergency Alarm I_0_I 0 = Audible
1 = Silent
65 Quick Arming I_0_I 0 = OFF
1 = ON
66 Auto Restore I_0_I 0 = OFF
1 = ON
67 Auto Bypass of Open Zones I_0_I 0 = OFF
1 = ON
68 Automation Mode During Alarm
(Enabled by Function 72)
I_0_I 0 = Flash
1 = Steady
69 Automation Bing Tone I_1_I 0 = NO
1 = Yes
70 Remote Arm/Disarm Chirp I_1_I 0 = No Chirps
1 = Chirps
71 Automation Flashes after Alarm I_0_I 0 = Standard
1 = Flashing after Alarm
72 Automation Active during Alarm I_0_I 0 = Standard
1 = Automation Active
73 Automation On while Armed I_0_I 0 = Standard
1 = On while Armed
74 Automation On during Entry/Exit I_0_I 0 = Standard
1 = ON during Entry/Exit
75 Automation Polarity I_1_I 0 = + when OFF
1 = + when ON
76 2-Way Audio
(must have VB2 – VB3 Installed)
I_2_I 0 = None
1 = Listen
2 = 2-Way Manual
3 = 2-way Full Duplex
78 Voice Enabled
(must have VB2 – VB3 Installed)
I_2_I 0 = Voice Response Disabled
1 = Voice Response Enabled
86 Call Routing I_1_I 0 = All to Primary or Secondary
1 = Alarms to Primary or Secondary
others to Supervisory Number
87 Remote Access Password I_9_I_8_I_7_I_6_I_5_I_4_I
88 Account Number I_ _I_ _I_ _I_ _I
(0 to 9 only)
89 Primary Phone Number Up to 20 digits
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I

A at start or middle of number adds 1-second delay
A at end of phone number adds a #
FIRE adds 5 second pause
CHIME adds *

90 Secondary Phone Number Up to 20 digits
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
91 Supervisory Phone Number Up to 20 digits
I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
92 Duress Code I_ _I 1 to 5 digits
93 Secondary User Code 1 I_ _I 1 to 5 digits
94 Secondary User Code 2 I_ _I 1 to 5 digits
95 Secondary User Code 3 I_ _I 1 to 5 digits
96 Secondary User Code 4 I_ _I 1 to 5 digits
97 Secondary User Code 5 I_ _I 1 to 5 digits
98 Page Alert Access Code I_ _I 1 to 5 digits
99 Installer Code I_ _I 1 to 5 digits
100 Remote Programming Lockout
(Downloading Enable)
I_0_I 0 = Unlock (Enabled)
1 = Lock (Disabled)
101 Swinger Shutdown I_0_I 0 = OFF
1 = 5 Alarms until Swinger
103 Dialing Delay I_0_I 0 = No Delay
1 = 15 Second Delay
104 Dialing Method I_0_I 0 = Tone
1 = Pulse
105 Report Format I_1_I 0 = 4/2
1 = Ademco Contact ID
107 Communicator Enabled I_1_I 0 = Disabled
1 = Enabled
108 Report System Trouble I_1_I 0 = NO
1 = Yes
110 Report Force Arming I_0_I 0 = NO
1 = Yes
111 Report Open/Close I_0_I 0 = NO
1 = Yes
2 = Master Code Only
113 Point ID Reporting for 4/2 Format I_1_I 0 = NO
1 = Yes
Below are 4/2 format signals, Contact ID Auto sends, normally leave alone, enter 00 to disable

Default 4/2 Reports
201 General Fire Panic Report Code I_1_I 0 to 99
202 General Emergency Report Code I_2_I 0 to 99
203 General Silent Panic Report Code I_3_I 0 to 99
204 General Burglary Report Code I_4_I 0 to 99
205 General Trouble Report Code I_6_I 0 to 99

210 Sensor 1 Alarm Report Code I_11_I 0 to 99
211 Sensor 2 Alarm Report Code I_12_I 0 to 99
212 Sensor 3 Alarm Report Code I_13_I 0 to 99
213 Sensor 4 Alarm Report Code I_14_I 0 to 99
214 Sensor 5 Alarm Report Code I_15_I 0 to 99
215 Sensor 6 Alarm Report Code I_16_I 0 to 99
216 Sensor 7 Alarm Report Code I_17_I 0 to 99
217 Sensor 8 Alarm Report Code I_18_I 0 to 99
218 Sensor 9 Alarm Report Code I_19_I 0 to 99
219 Sensor 10 Alarm Report Code I_20_I 0 to 99
220 Sensor 11 Alarm Report Code I_21_I 0 to 99
221 Sensor 12 Alarm Report Code I_22_I 0 to 99
222 Sensor 13 Alarm Report Code I_23_I 0 to 99
223 Sensor 14 Alarm Report Code I_24_I 0 to 99
224 Sensor 15 Alarm Report Code I_25_I 0 to 99
225 Sensor 16 Alarm Report Code I_26_I 0 to 99
226 Sensor 17 Alarm Report Code I_27_I 0 to 99
227 Sensor 18 Alarm Report Code I_28_I 0 to 99
228 Sensor 19 Alarm Report Code I_29_I 0 to 99
229 Sensor 20 Alarm Report Code I_30_I 0 to 99
230 Sensor 21 Alarm Report Code I_31_I 0 to 99
231 Sensor 22 Alarm Report Code I_32_I 0 to 99
232 Sensor 23 Alarm Report Code I_33_I 0 to 99
233 Sensor 24 Alarm Report Code I_34_I 0 to 99
234 Sensor 1 Trouble Report Code I_41_I 0 to 99
235 Sensor 2 Trouble Report Code I_42_I 0 to 99
236 Sensor 3 Trouble Report Code I_43_I 0 to 99
237 Sensor 4 Trouble Report Code I_44_I 0 to 99
238 Sensor 5 Trouble Report Code I_45_I 0 to 99
239 Sensor 6 Trouble Report Code I_45_I 0 to 99
240 Sensor 7 Trouble Report Code I_47_I 0 to 99
241 Sensor 8 Trouble Report Code I_48_I 0 to 99
242 Sensor 9 Trouble Report Code I_49_I 0 to 99
243 Sensor 10 Trouble Report Code I_50_I 0 to 99
244 Sensor 11 Trouble Report Code I_51_I 0 to 99
245 Sensor 12 Trouble Report Code I_52_I 0 to 99
246 Sensor 13 Trouble Report Code I_53_I 0 to 99
247 Sensor 14 Trouble Report Code I_54_I 0 to 99
248 Sensor 15 Trouble Report Code I_55_I 0 to 99
249 Sensor 16 Trouble Report Code I_56_I 0 to 99
250 Sensor 17 Trouble Report Code I_57_I 0 to 99
251 Sensor 18 Trouble Report Code I_58_I 0 to 99
252 Sensor 19 Trouble Report Code I_59_I 0 to 99
253 Sensor 20 Trouble Report Code I_60_I 0 to 99
254 Sensor 21 Trouble Report Code I_61_I 0 to 99
255 Sensor 22 Trouble Report Code I_62_I 0 to 99
256 Sensor 23 Trouble Report Code I_63_I 0 to 99
257 Sensor 24 Trouble Report Code I_64_I 0 to 99

258 Force Arming Report Code I_65_I 0 to 99
259 Duress Report code I_66_I 0 to 99
261 KP Fire Report Code I_68_I 0 to 99
262 KP Emergency (Police) Report Code I_69_I 0 to 99
263 System Test/Cancel Report Code I_70_I 0 to 99
264 System Low Bat Restore Code I_71_I 0 to 99
266 System Low Bat Report Code I_73_I 0 to 99

Hardwired loops must be assigned a Zone from 01 to 24

301 Hardwire Zone 1 Assignment I_ _I 01 to 24
302 Hardwire Zone 2 Assignment I_ _I 01 to 24
303 Hardwire Zone 3 Assignment I_ _I 01 to 24
304 Hardwire Zone 4 Assignment I_ _I 01 to 24
305 Hardwire Zone 5 Assignment I_ _I 01 to 24
306 Hardwire Zone 6 Assignment I_ _I 01 to 24
307 Hardwire Zone 7 Assignment I_ _I 01 to 24
308 Hardwire Zone 8 Assignment I_ _I 01 to 24
999 Default System 999 + TEST + 999 + TEST