Linear DF-16 SSD Defiant Panel Program

1704 Dialer can only programmed with P-9 Programmer (See bottom of this page)
Formats Radionics HEX, Sescoa Standard, Sescoa Superspeed
Enter Program User Code + LEARN (1 Gong, 5 Beeps)
Exit Program Press OFF for 3 seconds
Compatible
Wireless
DF-10 Wireless Keypad (Linear DVS2400 Sensors likely won’t work)
DF-31 Door/Window
DF-41 & DF-42 Keyfobs
DF-54 Motion Detector
DF-71 Smoke Detector
Add Sensor
1. Enter Zone (01 to 16), Zone light turns ON
2. Activate Sensor (press AUTO on keyfob)

1 Bing = Learned OK
Long Buzz = Another sensor already learned in that zone
Delete Sensor Enter Zone (01 to 16) then TEST (1 Bing, Zone Light turns OFF)
Interior Zones User Code + LEARN (1 Gong 5 Beeps)
Enter Zone Number + HOME + 7 + AWAY (1 Bing)
(Instant or Delay Zones selected by jumper under Transmitter)
Default System Hold LEARN button while plugging in AC Transformer
Defaulting the system doesn’t default the dialer
(Learn Master Code again with * + New Code (1 to 5 digits) + OFF)

To Program below enter Location + HOME, enter New Value + AWAY
LOC Description Possible Values Default
20 Entry Delay 1 to 255 seconds 45
21 Exit Delay 1 to 255 seconds 30
30 Burglary Siren Time 1 to 30 minutes 5
31 Emergency Siren Time 1 to 30 minutes 5
32 Fire Siren Time 1 to 30 minutes 30
40 Automation Output Time 1 to 2500 seconds 0
50 Remote Keyfob Arming Level 2 = HOME Mode
3 = AWAY Mode
3
51 Remote Control Disarming Level 0 = OFF Mode
1 = CHIME Mode
0
60 Auto Bypass of Open Zones 0 = OFF
1 = ON
1
61 Auto Reactivation of Bypassed Zones 0 = OFF
1 = ON
0
62 Quick Arming Enable 0 = OFF
1 = ON
1
63 Emergency Panic Audible/Silent 0 = Audible
1 = Silent
0
64 Burglar Alarm Audible/Silent 0 = Audible
1 = Silent
0
65 Exit Delay Beeps 0 = OFF
1 = ON
1
66 Entry Delay Beeps 0 = OFF
1 = ON
1
67 Test Sensor Light
(Reminds to test every 2 weeks)
0 = OFF
1 = ON
0
68 Automation Output Polarity 0 = Voltage w/OFF
1 = Voltage when ON
1
69 Automation Output during E/E Delays 0 = NO
1 = YES
0
70 Automation Output when Armed 0 = NO
1 = YES
0
71 Automation Output Flashes in Alarm 0 = NO
1 = YES
0
72 Automation Flashes During & after Alarm 0 = NO
1 = YES
0
73 Remote Arm/Disarm Chirp 0 = NO
1 = YES
1
74 Automation Bing Tone 0 = NO
1 = YES
1
98 Secondary User Code 1 to 5 Digits ????
99 Master User Code 1 to 5 Digits ????