Linear 21st Sentry CP90 Basics

Zones 3 Hardwire Zones, 61 Wireless = 64 total Zones
Frequency 303.875 Mhz
AC Transformer 16-Volt plugged into wall somewhere in house
Batteries
Main Panel 12-volt 4.5 or 7 amp
Doors/Windows 2 3-volt Lithium Hearing-Aid type DL or CR 2032
Panics 2 3-volt Lithium Hearing-Aid type DL or CR 1620
Smoke Detectors 2 9-volts Alkaline
Glassbreaks 1 or 2 9-volt Alkaline
Panic Buttons Police, Fire and Medical, press for 3 seconds to activate
Downloadable NO
Arm Stay 3 + User Code
Arm Away 4 + User Code
Arm Night 5 + User Code (Doors Delay/Motions are bypassed)
Arm Instant 6 + User Code (Instant Doors, Motions Bypassed)
Quick Arm Hold Arming Level key (3, 4, 5 or 6)
Disarm 0 + User Code
System Status Press to show Arming Level,
Sensor Status Hold for 1 second for status of sensors
Alarm Memory key + 96 (Last 9 alarms scroll across display)
Clear Display key + 97
Reset Smoke key + 99
Manual Bypass 1. Arm system to desired level
2. Press + Zone (01 to 64)
Force Bypass 1. Arm system with Zone open (Keypad will give protest beeps)
2. Hold 2 seconds (System will arm with open zones bypassed)
Door Chime Press 2 + User Code
Battery Test key + 98
Sensor Test 8 + User Code (Keypad sounds one loud beep if sensor is opened)
(Wireless motions require no movement for 4 minutes prior to testing)
Set Time + 80 + 2-digit Minutes (00-59)
+ 81 + 2-digit Hours (Military Time 01 to 23)
+ 82 + 2-digit Date (01-31)
+ 83 + 2-digit Month (01-12 01=January, 12=Decenber)
+ 84 + 2-digit Year (98 = 1998)
+ 85 + 2-digit Day of week (01-07 01=Sunday, 07=Saturday)
Display Adjust Hold * key and press 0 (Bright) to 7 (DIM)