Guardsman 5000M Trouble

BAT /
OPEN Light
OFF
FLASHING
Normal
Wireless Zone Low Battery (Zone will also turn ON)
INT Light OFF
ON
Normal
Motion Sensor Alarm
EXTERIOR Light OFF
ON
Normal
Alarm from Door/Window Alarm
DISARM Light OFF
ON
System Armed in Home or Away mode
System Disarmed (Duhh)
ARM Light OFF
ON
FLASHING
System is Disarmed
System Armed in Away mode
System Armed in Home mode
HELP Light OFF
ON
Normal
Panic Keys (1 & 3) were Activated
FIRE Light OFF
ON
Normal
Fire Alarm occured or is occuring
ALERT Light OFF
ON
Normal
System is calling Monitronics
Test Mode 1. Enter 4-Digit Code + */TEST (Disarm Light will Blink)
2. Open all Sensors, keypad will beep
3. Press #/OFF Button to Exit
Phone Test 1. Enter User Code + */TEST Button
2. Press 1 + */TEST Button (System should call and go 2-way)
3. Press 2 + */TEST Button
4. Press OFF key to end test and CLR to reset System
Sensor Setup (Requires Keyfob)
1. All sensors must have matching Dip Switch House settings
2. Set Zone by 4-pin Dip Switch on sensor
3. Enter Master Code then press TEST
4. Press 9 + TEST
5. Press ARM on Keyfob 2 seconds, Panel beeps to accept new House Code
6. Enter Master Code + OFF to exit
Note: Setting sensor as Zone 1 automatically makes it an E/E Zone