Zones Up to 76 Wireless Zones, 8 Hardwired
AC Tranformer 16.5 volts
Batteries
Main Panel 12 volt rechargeable Gel-Cell
Door/Window 3.6-volt Lithium
Motions 3.6-volt Lithium
Smoke Detector 2 9-volt Alkaline
Downloadable Yes
Panic Buttons
Police, Fire, and Medical
Or by Telephone * 77777 = Fire Panic
* 88888 or
* * * *
= Police Panic
* 99999 = Medical Panic
Arm Away 4 digit code + 3 “Alarm System is ON, Level 3..”
Arm Stay 4 digit code + 2 “Alarm System is ON, Level 2..”
Disarm 4 digit code + 1 “Alarm System is OFF, Level 1..”
System Status Press STATUS
Instant Arm Arm system, press 4 (NO DELAY), panel will say “NO DELAY”
Direct Bypass Enter 4-digit code, press BYPASS + 2-digit zone (01-76)
Force Bypass 1. Open Zone and arm system, keypad will beep rapidly
2. Press BYPASS “Alarm System is ON, Sensor Bypassed”
Door Chimes 4-digit code + 7 “ON” or “OFF”
Phone Test Master Code + 8
Sensor Test Master Code + 9
Activate all doors/windows/motions
Master Code + 1 ends Test
(Wireless motions require no movement for 4 minutes prior to testing)
Adjust Display Hold down 1, 2 3, or 4 keys for desired brightness level
Telephone Access
At Home Pick up Telephone, enter 4-digit User Code
(Press * + Command (example * 4-digit code + 1 disarms system)
If Away 1. Call house, let phone ring once
2. Wait 10 to 40 seconds, call again, system should answer
3. Press * + 4-digit User Code
(Commands are entered by * User Code + Function (* 4-digit code + 1 disarms)
Activate
Download
CODE + STATUS + 8 + 88 + COMMAND + COMMAND
Enable
Download
88 + COMMAND + COMMAND, keypad should say “ON”