DO NOT CHANGE BATTERIES IN SENSORS OR SENSOR PROGRAMMING WILL ERASE |
DO NOT POWER SYSTEM DOWN OR PANEL PROGRAM WILL ERASE (see diagram at bottom of page)
|
Trouble and Event signals that are sent to us |
|
90 AC Failure |
(Check breakers and transformer) |
91 Low Panel Battery |
(Battery may be found only at local branch) |
92 CPU Tamper |
(Make sure cover is closed on Main panel) |
94 Receiver Failure |
(Internal trouble, set for service) |
94 Invalid Sensor |
(Incorrect sensor programming, set for service) |
95 CPU Back in Service |
(AC Power came back on, everythings okay) |
96 Fail To Communicate |
(Try sending a signal) |
97 Missing Phone Line |
C5 Memory Lost |
(Set for service) |
|
Reset |
4-digit Code + 0 (CANCEL/DISARM), keypad will sound 1 long beep
|
Sensor Test |
1. |
Press Master Code + 9 |
2. |
Main panel display will begin scrolling all sensor numbers |
3. |
Open Doors/Windows/walk past motion, press TEST on Smoke Det. |
4. |
Siren will sound for 1 second indicating sensor is good |
5. |
Main Panel will remove tested sensor from display
(A bad sensor will not beep at keypad or be removed from display)
|
6. |
When all sensors are tested Main Panel should have no sensors showing |
7. |
Enter 4-digit Code + 0 (CANCEL/DISARM) to end |
|