GE / ITI / UC SX IV Trouble


This is the display screen on main control box.
If trouble can’t be corrected power down by turning power switch OFF (See wiring Diagram)
DO NOT POWER SYSTEM DOWN WITH AC AND BATTERY OR PROGRAMMING WILL ERASE!
POWER OFF AC Power Failure
SUPERVISORY ON Sensor Failure, zone will show on Control Panel
ALARM light ON Alarm Memory, zone will show on Control Panel
BYPASS light ON Sensor Bypassed, zone will show on Control Panel
Sensor Test 4-digit Code + 9 4-digit Code + 0 (CANCEL/DISARM) to end
Signals 01 = CPU too Close (Another SX-4B is interferring)
77 = Low Battery in Wireless Keypad
80 = Fire Panic
81 = Police Panic
82 = Medical Panic
83 = Phone Test
84 = Opening Report
85 = Closing Report
86 = Duress Code
87 = Force Armed
90 = AC Failure
91 = CPU Low Battery
93 = Test Signal
95 = AC Power Restored
96 = Fail to Communicate
97 = Dialer Checksum Error (Loss of CPU Memory)