Zone List – = Cut, | = Not Cut |
Sensor |
Sensor Type |
Tooth/Comb |
|
|
4 |
5 |
6 |
7 |
8 |
9 |
(- = Open | = Closed) |
01 |
System Conflict (with another SX-Vb) |
– |
– |
– |
– |
– |
| |
02 |
Unsupervised Audible Police Panic |
– |
– |
– |
– |
| |
– |
03 |
Unsupervised Audible Police Panic |
– |
– |
– |
– |
| |
| |
04 |
Unsupervised Silent Police Panic |
– |
– |
– |
| |
– |
– |
05 |
Unsupervised Silent Police Panic |
– |
– |
– |
| |
– |
| |
06 |
Supervised Audible Police Panic |
– |
– |
– |
| |
| |
– |
07 |
Supervised Silent Police Panic |
– |
– |
– |
| |
| |
| |
10 |
Unsupervised Audible Medical Panic |
– |
– |
| |
– |
– |
– |
11 |
Unsupervised Audible Medical Panic |
– |
– |
| |
– |
– |
| |
12 |
Supervised Audible Environmental |
– |
– |
| |
– |
| |
– |
13 |
Supervised Audible Environmental |
– |
– |
| |
– |
| |
| |
14 |
Supervised Audible Environmental |
– |
– |
| |
| |
– |
– |
15 |
Supervised Audible Environmental |
– |
– |
| |
| |
– |
| |
16 |
Supervised Audible Environmental |
– |
– |
| |
| |
| |
– |
17 |
Supervised Audible Environmental |
– |
– |
| |
| |
| |
| |
20 |
Fire Emergency |
– |
| |
– |
– |
– |
– |
21 |
Fire Emergency |
– |
| |
– |
– |
– |
– |
23 |
Fire Emergency |
– |
| |
– |
– |
| |
| |
24 |
Fire Emergency |
– |
| |
– |
| |
– |
– |
25 |
Fire Emergency |
– |
| |
– |
| |
– |
| |
26 |
Fire Emergency |
– |
| |
– |
| |
| |
– |
27 |
Fire Emergency |
– |
| |
– |
| |
| |
| |
30 |
Special Intrusion (Safes, Gun Cabinets) |
– |
| |
| |
– |
– |
– |
31 |
Special Intrusion (Safes, Gun Cabinets) |
– |
| |
| |
– |
– |
| |
32 |
Special Intrusion (Safes, Gun Cabinets) |
– |
| |
| |
– |
| |
– |
33 |
Special Intrusion (Safes, Gun Cabinets) |
– |
| |
| |
– |
| |
| |
34 |
Delay Doors |
– |
| |
| |
| |
– |
– |
35 |
Delay Doors |
– |
| |
| |
| |
– |
| |
36 |
Delay Doors |
– |
| |
| |
| |
| |
– |
37 |
Delay Doors |
– |
| |
| |
| |
| |
| |
40 |
Instant Doors |
| |
– |
– |
– |
– |
– |
41 |
Instant Doors |
| |
– |
– |
– |
– |
| |
42 |
Instant Doors |
| |
– |
– |
– |
| |
– |
43 |
Instant Doors |
| |
– |
– |
– |
| |
| |
44 |
Instant Doors |
| |
– |
– |
| |
– |
– |
45 |
Instant Doors |
| |
– |
– |
| |
– |
| |
46 |
Instant Doors |
| |
– |
– |
| |
| |
– |
47 |
Instant Doors |
| |
– |
– |
| |
| |
| |
50 |
Instant Doors |
| |
– |
| |
– |
– |
– |
51 |
Instant Doors |
| |
– |
| |
– |
– |
| |
52 |
Instant Doors |
| |
– |
| |
– |
| |
– |
53 |
Instant Doors |
| |
– |
| |
– |
| |
| |
54 |
Instant Doors |
| |
– |
| |
| |
– |
– |
55 |
Instant Doors |
| |
– |
| |
| |
– |
| |
56 |
Instant Doors |
| |
– |
| |
| |
| |
– |
57 |
Instant Doors |
| |
– |
| |
| |
| |
| |
60 |
Interior Motions |
| |
| |
– |
– |
– |
– |
61 |
Interior Motions |
| |
| |
– |
– |
– |
| |
62 |
Interior Motions |
| |
| |
– |
– |
| |
– |
63 |
Interior Motions |
| |
| |
– |
– |
| |
| |
64 |
Interior Momentary Mats, Sound Sensors |
| |
| |
– |
| |
– |
– |
65 |
Interior Momentary Mats, Sound Sensors |
| |
| |
– |
| |
– |
| |
66 |
Delayed Interior Momentary |
| |
| |
– |
| |
| |
– |
67 |
Delayed Interior Momentary
(Motion trips like an Entry Door)
|
| |
| |
– |
| |
| |
| |
70 |
Interior Doors (Active in Levels 4 – 7) |
| |
| |
| |
– |
– |
– |
71 |
Interior Doors (Active in Levels 4 – 7) |
| |
| |
| |
– |
– |
| |
72 |
Interior Doors (Active in Levels 4 – 7)
(Motion trips like an Entry Door)
|
| |
| |
| |
– |
| |
– |
73 |
Interior Doors (Active in Levels 4 – 5) |
| |
| |
| |
– |
| |
| |
74 |
Interior Doors (Active in Levels 4 – 5) |
| |
| |
| |
| |
– |
– |
75 |
Delayed Interior Zones |
| |
| |
| |
| |
– |
| |
76 |
Delayed Interior Zones |
| |
| |
| |
| |
| |
– |