GE / ITI / UC Simon Program

Report Format ITI
Panel Version Power down then back up, panel will say “Hello System (Version Number) is OK”
Enter Program Open keypad cover and press 4321 using Red Number Keys
If 6-digit User Codes are enabled use 654321
If 5-digit User Codes are enabled use 54321
If 3-digit User Codes are enabled use 321
Exit Program Close Cover
Default Panel Hold CANCEL, CLOCK SET and MINUTES + while powering up
Add Sensor
1. Press ADD under START MENU
2. Press SENSOR/REMOTE until you hear correct Voice Description
(Press OPTION if North, South, East and West is needed)
3. Press DONE, enter 2-digit Group<
01 = Police Panic
Common Sensor Groups —> 10 = Entry Exit
13 = Instant
CLICK HERE for Complete List 17 = Interior Follower (Motions)
20 = Delayed Interior Follower
26 = Fire
4. Learn Sensor by the following

Door Sensor Open Sensor cover, push button (Older Sensor just open cover)
Glassbreaks Tap glass 3 or 4 inches from sensor or make a lot of noise
Motions Move past motion (Motions have 5 minutes movement lockout)
Heat Sensor Rub hands together until warm, place on sensor for 30 seconds
Shock Sensor Tap glass twice, wait 30 seconds then try again
Smoke Press and hold test button on Smoke until Panel sounds beeps
(some require just removing from mounting base)
Keyfobs Hold LOCK and UNLOCK buttons for 3 seconds
Touchpads Press and hold 2 EMERGENCY buttons for 3 seconds
5. Keypad should say “Sensor ?? programmed OK”
Hardwire
Zones
Zones on Panel require 4.7k resistor, not needed if connected to Wireless sensors
Hardwire Zones on Panel or Wireless Sensors MAY have to be open to learn
Zone
Assignments
A learned Sensor is automatically added to next available Zone Number
to assign different Zone enter 2-digit Zone Number AFTER entering Group Number
If learning Hardwire Contact on Wireless Sensor learn with Hardwire Contact OPEN
Delete Sensor Press DELETE + SENSOR/REMOTE until you hear item to delete then DONE
Enable
Function
1. Press ADD button (under START MENU)
2. Press OPTION button (Under MAIN MENU) + 2-Digit Program Location
3 Press DONE (May have to enter digits for Phone Numbers, Accounts etc)
Disable
Function
1. Press DELETE button (under START MENU)
2. Press OPTION button (Under MAIN MENU) + 2-Digit Program Location
3 Press DONE, “Keypad should say “Option ?? Deleted”

If you are not allow into certain locations your not using the Installer Code
* = areas Customer can access
LOC Description Value Variables
01* Panel Beeps I_ON_I
ON = Panel Beeps Enabled
OFF = Panel Beeps Disabled
02* Panel Voice I_ON_I
ON = Panel Voice Enabled
OFF = Panel Voice Disabled
03* Latchkey Option I_OFF_I OFF = Latchkey Option Disabled
12:00AM to 11:59 PM Latchkey Time
04 Primary Phone Number I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
(Up to 18 Digits, press TEST if Pause is needed)
05 Second Phone Number I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
(Leave Blank)
06 Download Phone Number I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I_ _I
(Leave Blank)
07 Account Number I_ _I_ _I_ _I_ _I_ _I
(0 at beginning if 4-Digit Account, DELETE resets to 00000)
08 Phone Lock I_OFF_I
ON = Communicator Locations Locked out
OFF = Defaulting resets Communicator Locations
09 Download Access Code I_1_I_2_I_3_I_4_I_5_I
10 Entry Delay I_030_I 005 to 120 seconds
11 Exit Delay I_060_I 005 to 120 seconds
12 Phone Mod 1 I_0_I 0 = All signals ITI Format
1 = All signals 4/2 Format
2 = Alarms ITI Format
3 = Alarms 4/2 Format
13 Phone Mod 2 I_6_I 0 = All signals ITI Format
1 = All signals 4/2 Format
2 = Alarms ITI Format
3 = Alarms 4/2 Format
4 = Non-Alarms ITI Format
5 = Non-Alarms 4/2 Format
6 = Phone 1 Failure ITI Format
7 = Phone 1 Failure 4/2 Format
8 = All but Alarms to Pager
9 = All Reports to Pager
14 DTMF Dialing I_ON_I
ON = Tone Dialing
OFF = Pulse Dialing
15 No Activity Timer I_OFF_I OFF = Activity Timer Disabled
02 to 24 hour Activity Timer
16 Auto Phone Test I_OFF_I OFF = Auto Phone Test Disabled
001 to 254 days between Phone Test
17 Dialer Delay I_OFF_I OFF = No Dialer Delay
001 to 120 = 001 to 120 second delay
18 Alarm Cancel I_002_I OFF = No Cancels
001 to 255 minute Cancel window
19 Sensor Supervisory Time I_12_I 02 to 24 hours
20 Manual Phone Test I_ON_I
ON = Manual Phone Test Enabled
OFF = Manual Phone Test Disabled
21 Opening Reporting I_OFF_I
ON = Opening Reporting Enabled
OFF = Opening Reporting Disabled
22 Closing Reporting I_OFF_I
ON = Closing Reporting Enabled
OFF = Closing Reporting Disabled
23 Force Arm Reporting I_OFF_I
ON = Force Arm Reporting Enabled
OFF = Force Arm Reporting Disabled
24 AC Power Fail Reporting I_OFF_I
ON = 15 minute AC Fail Reporting
OFF = AC Fail Reporting Disabled
25 CPU Low Battery Reporting I_ON_I
ON = Low Battery Reporting Enabled
OFF = Low Battery Reporting Disabled
26 Fail to Communicate I_ON_I
ON = Trouble Indication Enabled
OFF = Trouble Indication Disabled
27 Ring/Hang/Ring I_1_I
OFF = Downloading Disabled
1 = 1 Ring/Hang/Ring or 10 Rings before Answer
2 = 2 Ring/Hang/Rings or 10 Rings before Answer
3 = 3 Ring/Hang/Rings or 10 Rings before answer
4 = 10 Rings before Downloader answer
29 Panel Siren Enabled I_ON_I
ON = Internal Siren Enabled
OFF = Internal Siren Disabled
30 Panic Button Enabled I_ON_I
ON = Enable Panic Button
OFF = Disable Panic Button
31 Day of Week (Event Buffer) I_ _I 0 = Sunday
1 = Monday
2 = Tuesday
3 = Wednesday
4 = Thursday
5 = Friday
6 = Saturday
32 300 Baud Communications I_ON_I
ON = 300 Baud Communications
OFF = 110 Baud Communications
Simon Reports
01 Zone 01
to
17 Zone 17
18 Police Panic Button
79 Alarm Activity Sensor
83 Phone Test
84 Opening Report
85 Closing User (Always User 6)
87 Force Arm
90 AC Power Failure & Restore
91 Low CPU Battery Failure & Restore
93 Automatic Phone Test
99   Latchkey (Panel hasn’t been disarmed before predetermined time)

X-10 Stuff
ITI Simon “Peacekeeper” by Protect America and “Simon Basic” will NOT do X-10, all other Simon’s will
Troubleshooting 1. X-10 module on wrong “leg” of AC wiring and can’t communicate with Panel
2. Wrong House Code or Unit ID
Garage Opener
(* on Keyfob)
(Requires X-10 Universal Module) CLICK HERE for Universal Module

1. Open Cover and enter Master Code
2. Press ADD then LIGHT CONTROL to assign House Code A to F (usually leave at A) + DONE
(This must match Universal Module dials connected to garage door)
3. Press ADD then LIGHT CONTROL then UNIT# until correct Unit ID sounds
(Must match X-10 Universal Module dials as well)
4. Press SENSORS until correct sensor is heard (Keyfob)
6. Press DONE to save and close cover
(Universal Module switches must be set for Momentary and Relay Only)
Program Lights (Requires Lamp Module) CLICK HERE for Lamp Module

1. Open Cover and enter Master Code
2. Press ADD then press LIGHT CONTROL to assign House Code (A to F) then DONE
(This must match Lamp Module dials connected to Light)
3. Press ADD then LIGHT CONTROL then UNIT# to assign Unit Number
(This must match Lamp Module dials as well)
Unit 1 to 8 most common, controlled by LIGHTS TIME or SENSOR ACTIVATED
Unit 9 to 16 are activated by All On or All Off commands (Keyfobs etc)
Unit 10 Flashes Lamps to Arming Level (1 Flash = Disarm, 2 = Stay, 3 = Away)
4. Press SENSORS to pick sensor that will activate Lamp Module then DONE
5. Close cover
Lights Entry/Exit
Activated
(Requires Lamp Module) CLICK HERE for Lamp Module

1. Open Simon Cover, enter Master Code
2. Press ADD then LIGHT CONTROL to assign House Code (A to F) then DONE
3. Press ADD + LIGHT CONTROL + UNIT# to assign Unit Number
4. Press ENTRY/EXIT DELAY
5. Close Cover
6. Set dials on Lamp Module to House Code (Letter Dial) and Unit# (Number Dial)
(Lights turn ON for 4 minutes during Entry and Exit Delay)
Lights Time
Activated
(Requires Lamp Module) CLICK HERE for Lamp Module

1. Open Simon Cover, enter Master Code
2. Press ADD then LIGHT CONTROL to assign House Code (A to F) then DONE
3. Press ADD + LIGHT CONTROL + UNIT# to assign Unit Number
4. Press TIME and select Start time with HOURS and MINUTES then DONE
5. Press HOURS and MINUTES to set End time then DONE
6. Close cover
7. Set dials on Lamp Module to House Code (Letter Dial) and Unit# (Number Dial)
(Activate by pressing LIGHTS TIME ACTIVATED button)
PowerHorn
Siren Setup
(Requires PowerHorn Module) CLICK HERE for PowerHorn Siren

1. Open Simon Cover, enter Master Code
2. Press ADD then LIGHT CONTROL to assign House Code (A to F) then DONE
3. Close Cover
4. Set Letter Dial on PowerHorn 1 Letter higher (if Simon is set at A then use B)
5. Set Unit Number Dial on PowerHorn (1 to 15) for Siren sounds only
or Unit Number 9 for Siren, Arming, Status and Trouble Beeps