GE / ITI / UC Simon XT Program

Information v1.0 = Original

v1.2 = More zone descriptors, added line cut detection, works with Alarm.com 2-way voice
Power Ratings Aux Power: 250 mA at 5.3 to 12.3 to 12.3 VDC unregulated
‘(5.3 if AC failure operating on battery)’
Enable Download 1. Scroll down to ‘System Programming’
2. Press the ‘Enter’ button
3. Enter the ‘Master’ code
4. Press the ‘Enter’ button
5. Display should say ‘Access Codes’
6. Scroll down to ‘Security’
7. Press the ‘Enter’ button
8. Display should say ‘Download Enable – Off’
9. Press the ‘Enter’ button
10. Scroll up one time
11. Press the ‘Enter’ button
12. Press ‘Status’ 4 times to exit user programming

Enter Programming 1. Scroll down to ‘System Programming’
2. Press the ‘Enter’ button
3. Enter the ‘Master’ code
4. Press the ‘Enter’ button
5. Display should say ‘Access Codes’

Access Codes Submenu

Dealer Code

Installer Code
Master Code
User Code 1
User Code 2
User Code 3
User Code 4
User Code 5
User Code 6
User Code 7
User Code 8
Duress Code
Code Length

Default

4321

4321
1234
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
4

Options

3 to 6 digits then OK to save

If Dealer Code is enabled these locations cannot be accessed by Installer Code

Access Code Length
Downloader Code
Phone Lock
Phone 1 and 2 Numbers
Phone 1 and 3 Report Mode
HW1 Output Function

3 to 6 digits then OK to save, DELETE = 4


Security Account Number 00000 0 to FFFFFFFFFF then OK to save (scroll keys = A to F)
Downloader Code 12345 00000 to 99999 the OK to save
Phone Lock OFF ON = Communicator locations locked out
OFF = Disabled

If enabled, the following locations are not reset by defaulting the panel:


Account Number
Dealer Code
Code Length
Phone 1
Phone 2
Phone 1 to 4 Report Mode
Phone Lock
Download Phone Number
Download Access Code

Auto Arm ON ON = 4-minute announcement of open zones before bypass
OFF = 1-time announcement of open zones before bypass

Exit Extend ON ON = Exit delay restarts if use enters during exit delay
OFF = Exit delay does not restart

Secure Arming OFF ON = Access code required to arm (does not affect keyfobs)
OFF = Access code not required to arm

No Arm on Low Battery OFF ON = Enabled
OFF = Disabled

Quick Exit OFF ON = Pressing ‘Disarm’ button if armed allows 2 minute entry/exit
OFF = Disabled

Downloader Enable ON ON = Enabled
OFF = Disabled

Supervisory Protest OFF ON = Protest if no sensor supervision sent in last 15 minutes
OFF = Disabled


Phone #’s Phone #1 (26 digits) |_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|
‘Bypass’ button = Pause
‘Disarm’ button = Delete the number
‘Enter’ = Saves

Phone #2 (26 digits) |_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|
Phone #3 (26 digits) |_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|
Phone #4 (26 digits) |_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|
Download # (26 digits) |_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|

Phone Options Manual Phone Test ON ON = Enabled
OFF = Disabled

Fail to Communicate ON ON = Phone trouble indication enabled
OFF = Disabled (disables siren/trouble beeps, does not disable reporting)

DTMF Dialing ON ON = Tone dialing
OFF = Pulse dialine

300 bps enabled ON ON = 300 baud communications
OFF = 110 baud communications

Ring/Hang/Ring 1 OFF = Downloading disabled
1 = Ring/Hang/Ring or 10 rings before answer
2 = Ring/Hang/Ring/Hang/Ring or 10 rings before answer
3 = Ring/Hang/Ring/Hang/Ring/Hang/Ring or 10 rings before answer
4 = 10 rings before download answer
5 = Ring/Hang/Ring
6 = Ring/Hang/Ring/Hang/Ring
7 = Ring/Hang/Ring/Hang/Ring/Hang/Ring

Dialer delay 30 15 to 45 seconds the OK to save
Call wait code OFF Enter up to 26 digits 0 to 9, * or # then OK to save
‘Bypass’ button = Pause
‘Disarm’ button = Delete number

Sensors Learn Sensor 1. Screen should say ‘Learn Sensor’.
2. Press the ‘Enter’ button.
3. Screen should say ‘Sn 1 Grp 10 Front Door’ and 10 should be flashing.
(If there is not a zone already programmed in zone 1, then it will say Sn 1, but if the first available zone is zone 8,
then it will say Sn 8. It is possible to choose what zone number you want to use by scrolling up and down).
4. 10 will now be flashing, if you want to use 10, press ‘Enter’, if not, then scroll or manually press the numbers you would like,
then press ‘Enter’.
5. If you want it to say ‘Front Door’, press the ‘Enter’ button, otherwise scroll up and down until you find the
correct zone descriptor.
6. Press the ‘Enter’ button.
7. This is important, press the ‘Enter’ button again to save.
8. Now you’ll be on the next zone available, either program the next zone or press the ‘Status’ button 3 times to exit programming.

Delete Sensor 1. Screen should say ‘Delete Sensor’.
2. Press the ‘Enter’ button.
3. Screen should say ‘Sn 1 Grp XX’.
4. If you want to delete zone 1, press the ‘Enter’ button, if you want a different zone, scroll up and down, then press ‘Enter’.
5. The screen should say ‘Deleted’.
6. Press the ‘Enter’ button.
7. Now you’ll be on the next zone, either choose the next zone to delete, or press the ‘Status’ button 3 times to exit programming.

Edit Sensor 1. Screen should say ‘Edit Sensor’.
2. Press the ‘Enter’ button.
3. Screen should say ‘Sn 1 Grp XX’.
4. If you want to edit zone 1, press the ‘Enter’ button, if you want a different zone, scroll up and down, then press ‘Enter’.
5. The group number should be flashing, keep it the same or scroll up and down to change the group, then press the ‘Enter’ button.
6. Now the descriptor will be flashing, keep it the same of scroll up and down to change the descriptor, then press the ‘Enter’ button.
7. Now you’ll be on the next zone, either choose the next zone to edit, or press the ‘Status’ button 3 times to exit programming.


Reporting
&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp
Reporting Options
Opening Reporting OFF ON = Enabled
OFF = Disabled
Closing Reporting OFF ON = Enabled
OFF = Disabled
Force Arm Reporting OFF ON = Enabled
OFF = Disabled
AC Power Failure 060 005 to 254 minutes before reporting
OFF = AC fail reporting disabled
Low CPU Battery ON ON = Low battery reportin genabled
OFF = Disabled
Sensor Alarm Restoral ON 1 = Immediately after sensor is closed
2 = After siren timeout and sensor restores
3 = When disarmed and sensor restores
OFF = Disabled
24 Hour Tamper (sensors) OFF ON = Reports tamper if armed or disarmed
OFF = Reports tamper on if armed
Supervisory/Tamper OFF ON = Supervisory sends as tamper
OFF = Supervisory sends as tamper
No Usage Timer OFF 2 to 254 day no usage timer
OFF = Disabled
Swinger Shutdown OFF ON = 1 alarm per armed period
OFF = Disabled
Program Report OFF ON = Reports if entering or exiting installer programming
OFF = Disabled
Fire Verify OFF ON = 1 minute delay before report or if another smoke trips
OFF = Immediate report
Report Comm Modes
Ph1 Rpt Mode OFF 0 = All SIA format
1 = All Contact ID format
2 = Alarms SIA format
3 = Alarms Contact ID format
4 = Non-Alarms SIA format
5 = Non-Alarms Contact format
6 = Phone failure SIA format
7 = Phone failure Contact ID format
8 = Voice dialer (alarms only)
OFF = Reporting disabled
Ph2 Rpt Mode OFF
Ph3 Rpt Mode OFF
Ph4 Rpt Mode OFF

Timers Latchkey Time OFF DISARM = OFF or enter 12:00AM to 11:59PM
1. Press ‘Enter’ then scroll buttons to edit Hours
2. Press ‘Enter’ then scroll buttons to edit Minutes
3. Press ‘Enter’ then scroll buttons to toggle AM/PM
4. Press ‘Enter’ to save and exit

Entry Delay 30 30 to 240 seconds and ‘Enter’ to save

Exit Delay 60 45 to 240 seconds and ‘Enter’ to save

No Activity Timeout OFF 2 to 24 hours the ‘Enter’
Disabled = Press ‘Disarm’

Auto Phone Test OFF 1 to 254 days between phone tests then ‘Enter’
Disabled = Press ‘Disarm’

Supervisory Time 12:00 12:00AM to 11:59PM
1. Press ‘Enter’ then scroll buttons to edit Hours
2. Press ‘Enter’ then scroll buttons to edit Minutes
3. Press ‘Enter’ then scroll buttons to toggle AM/PM
4. Press ‘Enter’ to save and exit

Alarm Cancel 6 6 to 254 minutes, 255 = always send cancels
Disabled = Press ‘Disarm’

RF Timeout 12 2 to 36 hours
Disabled = Press ‘Disarm’

Fail to Open Time OFF 12:00AM to 11:59PM
Disabled = Press ‘Disarm’

Fail to Close Time OFF 12:00AM to 11:59PM
Disabled = Press ‘Disarm’

Siren Timeout 5 2 to 254 minute siren timeout
Disabled = Press ‘Disarm’

Arming LED Shutdown OFF ON = LED buttons turn off 30 seconds from last key press
OFF = Disabled

Unvacated Premises ON Auto stay/away arming (Auto Arm must also be enabled)
OFF = Disabled

Smoke Supervision OFF Supervisory signal every 4 hours
OFF = Supervisory signal as specified by RF Timeout option


Touchpad Options Keyfob No Delay OFF ON = Keyfob arms to no delay (instant)
OFF = Keyfob arms normally

Panic Alarms OFF ON = Enable Police, Auxiliary and Fire panics
OFF = Disable Police, Auxiliary and Fire panics

OFF ON = Keyfob/Touchpad disarms only during Entry/Exit delay
OFF = Keyfob/Touchpad can disarm anytime


System Options RF Jam Detect OFF ON = Enabled
OFF = Disabled

RF Jam Detect OFF ON = Enabled
OFF = Disabled

Demo Mode OFF ON = Enabled
OFF = Disabled

Turns off Low Battery Supervision
System time setting is not required
Leaves mic open continuously during 2-way session

HWIN1 Function 1 1 = Exterior siren output
2 = Output activated when armed
3 = Output activated when disarmed
4 = Output activated by fail to communicate
5 = Output activated when panel is in alarm
OFF = No output (must be OFF if used as a hardwire zone)

24 Hour Time OFF ON = Panel displays 24-hour clock
OFF = Panel displays 12-hour clock


Siren Options Panel Piezo Beeps ON ON = Enabled
OFF = Disabled

Panel Voice ON ON = Panel voice enabled
OFF = Panel voice disabled (when arming)

Panel Piezo Alarm ON ON = Enabled
OFF = Disabled

Trouble Beeps ON ON = Enabled
OFF = Disabled

Voice Chime ON 1 = Voice chime enabled
2 = “Gong” chime, no voice
3 = “Doorbell” chime, no voice
DELETE = OFF, no voice chime

Status Beep Volume 7 Default = 07 (01 being the lowest, 07 being the highest)

HW Siren Supervision OFF ON = Enable siren supervision (4.7k resistor is required)
OFF = Disabled

Speaker Volume (Voice) 8 8 = default (1 being the lowest, and 8 being the highest)

Silent Police Panic OFF ON = Police Panic Silent
OFF = Police Panic Audible

Alarm Report Verify OFF ON = “Phone Comm is OK” display on successful communication
OFF = No display on successful phone communication


Audio Verify Audio Mode OFF 1 = Instant
2 = Callback
Disabled = Press ‘Disarm’ button

Fire Shutdown OFF ON = Fire siren shutdown during 2-way voice
OFF = Disabled

Panic Talk (Silent) OFF ON = Listen-In only during silent panics
OFF = 2-way voice active on silent panics (sensor types 2 and 3)

VOX RX (Receiver) Gain 6 6 = Default (1 being the lowest, and 10 being the highest)

VOX Mic Gain 24 24 = Default (1 being the lowest, and 10 being the highest)

VOX Gain Range 64 64 = Default (1 being the lowest, and 64 being the highest)

Manual Mic Gain 64 64 = Default (1 being the lowest, and 64 being the highest)


Light Control Set Entry Lights Entry Light
Unit 1:OFF
1. Scroll keys selects X-10 Unit 1 to 8 then ‘Enter’
2. Scroll keys toggle ON/OFF
3. Press ‘Status’ button to exit
(If ON any X-10 using that Unit number turns on during Entry Delay

Sensor Light Sn1 Front Door
X-10 Unit = 1
1. Scroll keys selects Sensor 1 to 40 then ‘Enter’
2. Scroll keys toggle ON/OFF
3. Press ‘Status’ button to exit
(If ON any X-10 using that Unit number turns on during Entry Delay)

Light Schedules Light Schedule 1
– – : – – – – : – –
1. Scroll keys selects schedule 1 to 8 (Unit 1 to 8) then ‘Enter’
2. Enter Start Time Hours (00 to 12) then ‘Enter’
3. Enter Start Time Minutes (00 to 59) then ‘Enter’
4. Scroll keys toggle Start AM/PM then ‘Enter’
5. Enter Stop Time Hours (00 to 12) then ‘Enter’
6. Enter Stop Time Minutes (00 to 59) the ‘Enter’
7. Scroll keys toggle Stop AM/PM then ‘Enter’
8. Press ‘Status’ to exit
(Turns X-10 devices ON/OFF by time, enabled in User Programming)

House Code
&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbspA
1. Press ‘Enter’ to edit Start and Stop times
2. Press ‘Status’ to exit
(Any X-10 device must match this House Code)

Lock Interval Lock Interval
– – : – – – – : – –
1. Press ‘Enter’ to edit Start and Stop times
2. Enter Start Time Hours (00 to 12) then ‘Enter’
3. Enter Start Time Minutes (00 to 59) then ‘Enter’
4. Scroll keys toggle Start AM/PM then ‘Enter’
5. Enter Stop Time Hours (00 to 12) then ‘Enter’
6. Enter Stop Time Minutes (00 to 59) the ‘Enter’
7. Scroll keys toggle Stop AM/PM then ‘Enter’
8. Press ‘Status’ to exit
(Time period which prevents Sensor Activated lights from turning ON)


Interactive Services GSM Module Status

&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbspRadio

&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbspGSM Freq.

&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbspGSM Band Selection

&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbspBattery

&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbspSN

&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbspSIM Card

&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbspVersion

Use 850 MHz Only (Forces module to use 850 MHz frequency)

Use 1900 MHz Only (Forces module to use 1900 MHz frequency)

Use Dual-Band Mode

Use Quad-Band Mode

(Alarm.com module serial number)

(Alarm.com module SIM card number)

(Alarm.com module firmware version)

Z-Wave Setup

&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbspNumber of Z-Wave &nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbspDevices

&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbspAdd Z-Wave Devices

&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbspRemove Z-Wave Device

&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbspZ-Wave Home ID

&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbspAccount Creation

&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbspDealer Logo Update


System Tests Sensor Test 1. Press ‘Enter’ to begin Sensor Test
2. Display will scroll all programmed sensors in system and beep 4 times every minute
3. Activate each sensor
&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbspDoor Sensors – Open Door or Window
&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbspMotion Senor – Remove front cover
&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbspSmoke Detector – Press and hold TEST button
&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp
Keyfobs – Press LOCK and UNLOCK keys at the same &nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsptime for 3 seconds
&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp
Touchpads – Press both Panic Buttons for 3 seconds
4. Display will show sensor and signal strength
&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp6 and above = Good signal strength
&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp&nbsp5 and below = Poor signal strength
5. After all sensors are tested display will show
6. Press ‘Status’ button to exit anytime during the test

Comm Test 1. Press ‘Enter’ to begin Comm Test
2. Display will show ‘Comm Test is On’
3. Panel sends a test signal, in 30 seconds display shows &nbsp&nbsp&nbsp&nbsp’Comm Test OK’
4. If test is not successful within 10 minutes display shows &nbsp&nbsp&nbsp&nbsp’Comm Failure’ and ‘Status’ light will turn on
5. Press ‘Staus’ to stop trouble beeps

System Download 1. Press ‘Enter’ to send download to our server
2. Display will show ‘Download in Progress’
3. Panel returns to normal (Will give no inidication if download is successful)