GE / ITI / UC Simon 3 Trouble

Panel will begin beeping with any trouble, press SYSTEM STATUS to find trouble
AC Power Failure Either AC transformer bad or plug-in not working
System Battery Failure Panel battery low, if replacing on Simon 1 see “Battery Test”
Sensor Failure Zone has failed to communicate with Keypad for 12 hours
Sensor Low Battery Sensor Battery Low
Fail To Communicate System can’t send signal to Monitronics
Option 50 Detected RF Interference (Section 50 RF Jam Feature is Enabled)
Module 1 or 2 Failure v2.2 Simons must have 47k ohm resistors across hardwire Zones
Set Clock 1. Open Keypad Cover and enter Master Code using RED Number Keys
3. Press CLOCK SET button
4. Set hours by pressing HOURS then + or – until correct
5. Set minutes by pressing MINUTES then + or – until correct
6. Press DONE when complete
7. Close Keypad Cover
Sensor Test 1. Open Keypad Cover and enter Master Code using RED Number Keys
2. Press TEST button once then press DONE (Leave cover open)
3. Keypad will say a list of all sensors that need tested
4. Open Door or Window, move by motion and it will be removed from list
5. When all sensors are tested keypad says “Sensor test complete press DONE”
6. Press DONE and close cover
Battery Reset 1. Open Keypad Cover and enter Master Code using RED Number Keys
2. Press TEST button once then press DONE
3. Close cover and press SYSTEM STATUS to see if low battery is gone
Phone Test
1. Open Keypad Cover and enter Master Code using RED Number Keys
2. Press TEST button twice
3. Keypad says “Phone test is On”
If Phone test is good keypad says “Phone test ok” In 2 minutes
If Test is bad keypad says “Phone Communication Failure” in 10 minutes