Clear Memory |
POLICE + POLICE + CANCEL + CANCEL |
Add Keyfob |
ACTIVITY LEVEL + ACTIVITY LEVEL + Keyfob (1 to 4) |
Delete Keyfob |
TEST + TEST + Keyfob (1 to 4) |
Learn Sensor |
ACTIVITY LEVEL + Sensor Group (00 to 29) + Sensor Number (01 to 17)
CLICK HERE for Complete List
|
Delete Sensor |
TEST + Sensor Number |
Exit Sensor Program |
STATUS (it will say “Invalid, Try Again”) |
Account Number |
FIRE + FIRE + ACTIVITY LEVEL + Last 5 digits of Account
(If not using J or B account numbers enter 0 + Last 4 of Account)
|
House Code |
FIRE + FIRE + House Code (001 to 254) |
Primary Phone |
FIRE + FIRE + TEST + Receiver Number |
Delete Phone |
FIRE + FIRE + TEST + 1 |
Format |
STATUS + CANCEL + CANCEL + (00, 01 or 03)
00 = ITI
01 = 4/2 2300Hz
03 = 4/2 1400Hz
|
|
Siren Timeout |
CANCEL + CANCEL + (02 to 15) |
Add Upper Sensor |
TEST + Sensor (79 to 98 except 86 to 88, 92 to 97) |
Delete Upper Sensor |
ACTIVITY LEVEL + Upper Sensor (79 to 98 except 86 to 88, 92 to 97) |
Upper Sensors |
79 |
No Activity Report (Customer hasn’t moved within a given time) |
80 |
Touchpad Fire Panic |
81 |
Touchpad Police Panic |
82 |
Touchpad Auxiliary Panic |
83 |
Manual Phone Test (Level 8) |
84 |
Opening Report |
85 |
Closing Report |
89 |
RF Touchpad Low Battery/Supervision Trouble |
90 |
AC Failure |
91 |
Panel Shutdown (Reports if on Battery only) or Low Panel Battery |
92 |
CPU Tamper |
93 |
Auto Phone Test |
94 |
Wireless Receiver Failure |
95 |
CPU Back in Service (AC Power is restored) |
96 |
Fail To Communicate |
98 |
Auto Event Buffer (Reports when 12 new events occur) |
|
Day Timeout |
STATUS + FIRE + FIRE + Time (02 to 24) |
Night Timeout |
STATUS + STATUS + Time (02 to 24) |
Pill Reminder 1 |
STATUS + POLICE + POLICE + 1 + 0000 to 2400 (time in hours) |
Pill Reminder 2 |
STATUS + POLICE + POLICE + 2 + 0000 to 2400 (time in hours) |
Pill Reminder 3 |
STATUS + POLICE + POLICE + 3 + 0000 to 2400 (time in hours) |
Pill Reminder 4 |
STATUS + POLICE + POLICE + 4 + 0000 to 2400 (time in hours) |
Set Feature |
CANCEL + CANCEL + ACTIVITY LEVEL + (20 to 24, 27, 30, 34 or 35) |
F20* |
ON = Interrogator Module Enabled |
OFF = Disabled |
F21 |
ON = Battery power only |
OFF = AC Power |
F22 |
ON = Tone Dialing |
OFF = Pulse Dialing |
F23 |
ON = Open/Closing Reporting Enabled |
OFF = Disabled except in Event Buffer |
F24 |
ON = Hardwire Zone Input Normally Open |
OFF = Normally Closed |
F25 |
Not Used |
F26 |
Not Used |
F27* |
ON = Panel Sounds disabled |
OFF = Panel Sounds enabled |
F30 |
ON = Low Bat reports Immediately, |
OFF = Reports according to STIME |
F32** |
ON = Wireless Fixed Panics not supervised in Away |
OFF = Fixed Panics supervised always |
F34 |
ON = External Output for Strobe |
OFF = Output for Siren |
F35 |
ON = System only switchable between DAY & NIGHT |
OFF = System Normal |
F43 |
ON = Demo Kit Enabled |
OFF = Disabled |
F44 |
ON = Exterior Siren Constant (not pulsed) |
OFF = Exterior Siren Pulsed |
F45 |
ON = Zone 1 set for Keyswitch Arming |
OFF = Zone 1 Normal |
F46 |
ON = Automatic Daylight Savings time correction |
OFF = No correction |
F47 |
ON = UL Fire Trouble Beeps restart 4 hours |
OFF = Beeps restart after 10 hours |
|
* = Must be ON if using Interrorgator Module
** = Version 5.1 and later
|
|