GE / ITI / UC Life Guard Program

Remove HELP Panic cover to expose programming keys
Enter Program
From Panel – Power system down, lower battery tray, power up system
From Keyfob – Lower battery tray, enter 4321 from keyfob
Exit Program Raise battery tray and tighten screws
Answer Download Press TEST for 3 seconds

Clear Memory POLICE + POLICE + CANCEL + CANCEL
Add Keyfob ACTIVITY LEVEL + ACTIVITY LEVEL + Keyfob (1 to 4)
Delete Keyfob TEST + TEST + Keyfob (1 to 4)
Learn Sensor ACTIVITY LEVEL + Sensor Group (00 to 29) + Sensor Number (01 to 17)
CLICK HERE for Complete List
Delete Sensor TEST + Sensor Number
Exit Sensor Program STATUS (it will say “Invalid, Try Again”)
Account Number FIRE + FIRE + ACTIVITY LEVEL + Last 5 digits of Account
(If not using J or B account numbers enter 0 + Last 4 of Account)
House Code FIRE + FIRE + House Code (001 to 254)
Primary Phone FIRE + FIRE + TEST + Receiver Number
Delete Phone FIRE + FIRE + TEST + 1
Format STATUS + CANCEL + CANCEL + (00, 01 or 03)

00 = ITI
01 = 4/2 2300Hz
03 = 4/2 1400Hz
Siren Timeout CANCEL + CANCEL + (02 to 15)
Add Upper Sensor TEST + Sensor (79 to 98 except 86 to 88, 92 to 97)
Delete Upper Sensor ACTIVITY LEVEL + Upper Sensor (79 to 98 except 86 to 88, 92 to 97)
Upper Sensors
79 No Activity Report (Customer hasn’t moved within a given time)
80 Touchpad Fire Panic
81 Touchpad Police Panic
82 Touchpad Auxiliary Panic
83 Manual Phone Test (Level 8)
84 Opening Report
85 Closing Report
89 RF Touchpad Low Battery/Supervision Trouble
90 AC Failure
91 Panel Shutdown (Reports if on Battery only) or Low Panel Battery
92 CPU Tamper
93 Auto Phone Test
94 Wireless Receiver Failure
95 CPU Back in Service (AC Power is restored)
96 Fail To Communicate
98     Auto Event Buffer (Reports when 12 new events occur)
Day Timeout STATUS + FIRE + FIRE + Time (02 to 24)
Night Timeout STATUS + STATUS + Time (02 to 24)
Pill Reminder 1 STATUS + POLICE + POLICE + 1 + 0000 to 2400 (time in hours)
Pill Reminder 2 STATUS + POLICE + POLICE + 2 + 0000 to 2400 (time in hours)
Pill Reminder 3 STATUS + POLICE + POLICE + 3 + 0000 to 2400 (time in hours)
Pill Reminder 4 STATUS + POLICE + POLICE + 4 + 0000 to 2400 (time in hours)
Set Feature CANCEL + CANCEL + ACTIVITY LEVEL + (20 to 24, 27, 30, 34 or 35)
F20* ON = Interrogator Module Enabled OFF = Disabled
F21 ON = Battery power only OFF = AC Power
F22 ON = Tone Dialing OFF = Pulse Dialing
F23 ON = Open/Closing Reporting Enabled OFF = Disabled except in Event Buffer
F24 ON = Hardwire Zone Input Normally Open OFF = Normally Closed
F25 Not Used
F26 Not Used
F27* ON = Panel Sounds disabled OFF = Panel Sounds enabled
F30 ON = Low Bat reports Immediately, OFF = Reports according to STIME
F32** ON = Wireless Fixed Panics not supervised in Away OFF = Fixed Panics supervised always
F34 ON = External Output for Strobe OFF = Output for Siren
F35 ON = System only switchable between DAY & NIGHT OFF = System Normal
F43 ON = Demo Kit Enabled OFF = Disabled
F44 ON = Exterior Siren Constant (not pulsed) OFF = Exterior Siren Pulsed
F45 ON = Zone 1 set for Keyswitch Arming OFF = Zone 1 Normal
F46 ON = Automatic Daylight Savings time correction OFF = No correction
F47 ON = UL Fire Trouble Beeps restart 4 hours OFF = Beeps restart after 10 hours
* = Must be ON if using Interrorgator Module
** = Version 5.1 and later